Part 6 - 19-0168 Firest Reno A100 (Revised).pdf

PDF 459 KB Posted

Attached to
Design Build Fire Station Facility Repair
Solicitation number
N4008520R4032
Issued by

View the file

Other files

File Type Posted
Amnd 0009 20R4032 FINAL.pdf PDF
Amnd 0008 20R4032 FINAL.pdf PDF
Amnd 0007 20R4032 FINAL.pdf PDF
Amnd 0006 20R4032 FINAL.pdf PDF
Amnd 0005 20R4032 FINAL.pdf PDF
Part 5 - 22 00 00.pdf PDF
Part 5 - 27 10 00 CLGS.pdf PDF
Part 5 - 33 71 01.pdf PDF
Part 5 - 33 71 02.pdf PDF
Part 6 - 2600 FIRE STATION 90-6845.pdf PDF
Part 5 - 01 33 10.5 20 DESIGN SUBMITTAL SCHEDULE 021320.pdf PDF
Part 5 - 23 09 23.13.pdf PDF
Part 5 - 26 20 00.pdf PDF
Part 6 - LCH4022_NFA_REQUEST.pdf PDF
Amnd 0004 20R4032 FINAL.pdf PDF
Part 5 - 26 32 13.pdf PDF
Part 5 - 26 51 00.00 22.pdf PDF
Part 5 - Revised Submittal Register.pdf PDF
Part 5 - 23 73 33.pdf PDF
Part 5 - 23 05 93.pdf PDF
Part 5 - 23 35 00.00 10.pdf PDF
Part 5 - 26 36 23.00 20.pdf PDF
HALL UPSTAIRS 3.JPG JPG image
IMG_3915.JPG JPG image
IMG_3916.JPG JPG image
PT RM.JPG JPG image
EXTERIOR 10.JPG JPG image
HALL UPSTAIRS 2.JPG JPG image
360_1679_Stitch_XHC.JPG JPG image
EXTERIOR 11.JPG JPG image
EXTERIOR 8.JPG JPG image
HOSE RM 2.JPG JPG image
WOMENS.JPG JPG image
EXTERIOR.JPG JPG image
GARAGE.JPG JPG image
IMG_3918.JPG JPG image
SLEEP.JPG JPG image
GARAGE 5.JPG JPG image
IMG_3911.JPG JPG image
Amnd 0003 20R4032 FINAL.pdf PDF
EXTERIOR 6.JPG JPG image
EXTERIOR 12.JPG JPG image
GAREG 2.JPG JPG image
EXTERIOR 2.JPG JPG image
IMG_3912.JPG JPG image
SLEEP 7.JPG JPG image
HALL UPSTAIRS.JPG JPG image
IMG_3917.JPG JPG image
SLEEP 5.JPG JPG image
MENS.JPG JPG image
Show 40 more

Latest 50 of 124 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 TYP

CONST. CONTR. NO.

DISCLOSURE OF INFORMATION CONTRACTOR SHALL COMPLY AS FOLLOWS:

A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE

CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS

OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS

CONTRACT OR ANY PROGRAM RELATED TO THIS CON- TRACT OR ANY PROGRAM

RELATED TO THIS CONTRACT, UNLESS:

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL;

OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE

DATE OF RELEASE.

B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO

BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE.

THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER

AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH

SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT

REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR

TO THE CONTRACTING OFFICER.

AutoCAD SHX Text

WALL TYPES

AutoCAD SHX Text No.

AutoCAD SHX Text

ITEM

AutoCAD SHX Text

RATING

AutoCAD SHX Text

HEIGHT

AutoCAD SHX Text

COMMENT

AutoCAD SHX Text

AutoCAD SHX Text

GWB WALL

AutoCAD SHX Text

NOT RATED

AutoCAD SHX Text

FLOOR TO STRUCTURE ABOVE

AutoCAD SHX Text 3 5/8" MTL STUDS @ 16" OC W/ ONE " HIGH IMPACT GWB LAYER EACH SIDE. PROVIDE FIBER GLASS BATT-INSULATION THROUGH 58" HIGH IMPACT GWB LAYER EACH SIDE. PROVIDE FIBER GLASS BATT-INSULATION THROUGH OUT WALL CAVITY

AutoCAD SHX Text

AutoCAD SHX Text

GWB WET AREAS

AutoCAD SHX Text

NOT RATED

AutoCAD SHX Text

FLOOR TO STRUCTURE ABOVE

AutoCAD SHX Text 3 5/8" MTL STUDS @ 16" OC W/ ONE " MOISTURE RESISTANT GWB ON WET SIDE & ONE "HIGH IMPACT GWB LAYER OTHER SIDE58" MOISTURE RESISTANT GWB ON WET SIDE & ONE "HIGH IMPACT GWB LAYER OTHER SIDE58"HIGH IMPACT GWB LAYER OTHER SIDE

AutoCAD SHX Text

AutoCAD SHX Text

GWB FURRED OUT WALL

AutoCAD SHX Text

NOT RATED

AutoCAD SHX Text

SEE SECTION

AutoCAD SHX Text

AutoCAD SHX Text

CONF ROOM & TRAINING RM WALLS

AutoCAD SHX Text

NOT RATED

AutoCAD SHX Text

FLOOR TO STRUCTURE ABOVE

AutoCAD SHX Text 3 5/8" MTL STUDS @ 16" OC W/ ONE " HIGH IMPACT GWB LAYER EACH SIDE & RC-1 CHANNEL AT 16" OC CONF/TRAINING RM 58" HIGH IMPACT GWB LAYER EACH SIDE & RC-1 CHANNEL AT 16" OC CONF/TRAINING RM SIDE. PROVIDE FIBER GLASS BATT-INSULATION THROUGH OUT WALL CAVITY

AutoCAD SHX Text

AutoCAD SHX Text

CMU WALL

AutoCAD SHX Text

RATED

AutoCAD SHX Text

FLOOR TO STRUCTURE ABOVE

AutoCAD SHX Text 8" CMU WALL WITH WIRE MESH REINFORCEMENT EVERY OTHER COURSE. PROVIDE HORIZONTAL RATED SHAFT ASSEMBLY AT MONITOR WINDOWS CONDITIONS. SEE TYP SECTION

AutoCAD SHX Text

AutoCAD SHX Text

CMU WALL

AutoCAD SHX Text

NOT RATED

AutoCAD SHX Text

FLOOR TO STRUCTURE ABOVE

AutoCAD SHX Text

8" CMU WALL WITH WIRE MESH REINFORCEMENT EVERY OTHER COURSE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

NOTE

AutoCAD SHX Text

WATER CLOSET & URINAL WITH PHENOLIC PARTITION

AutoCAD SHX Text

SHOWER WITH PHENOLIC PARTITION

AutoCAD SHX Text

WALL MOUNTED HAND WASH SINK

AutoCAD SHX Text

FLOOR MOUNTED JANITOR CLOSET SINK

AutoCAD SHX Text

ELECTRIC WATER COOLERS

AutoCAD SHX Text

ICEMAKERS (NIC)

AutoCAD SHX Text

REFRIGERATOR (NIC)

AutoCAD SHX Text COPIER (nic)

AutoCAD SHX Text

SHREDDER

AutoCAD SHX Text

FILE CABINET (NIC)

AutoCAD SHX Text

CHAIRS (NIC)

AutoCAD SHX Text

STROLLER (NIC)

AutoCAD SHX Text

FURNITURE (SOFA AND TABLE) (NIC)

AutoCAD SHX Text

SACO LOCKABLE LOCKER (NIC)

AutoCAD SHX Text

DESK/CUBICLE/CHAIR (NIC)

AutoCAD SHX Text

HEADS LOCKABLE LOCKERS (NIC)

AutoCAD SHX Text

CONFERENCE ROOM TABLE AND CHAIRS (NIC)

AutoCAD SHX Text

BASE/WALL CABINET WITH COUNTER MOUNTED SINK

AutoCAD SHX Text NOTES: 1. THE DESIGNER OF RECORD MUST FIELD VERIFY ALL THE CONDITIONS SHOWN. THESE DETAILS AND RECOMMENDATIONS MUST NOT BE CONSIDERED THE FINAL DESIGN. IT IS THE DESIGNER OF RECORD RESPONSIBILITY TO REPRESENT THE SCOPE OF WORK IN THE DESIGNER OF RECORD MUST FIELD VERIFY ALL THE CONDITIONS SHOWN. THESE DETAILS AND RECOMMENDATIONS MUST NOT BE CONSIDERED THE FINAL DESIGN. IT IS THE DESIGNER OF RECORD RESPONSIBILITY TO REPRESENT THE SCOPE OF WORK IN SUFFICIENT DETAILS IN THE DRAWINGS AND TO DESCRIBE IT IN SUFFICIENT DETAIL IN THE SPECIFICATIONS. THE SECTIONS AND DETAILS ARE GENERIC IN NATURE AND NOT THE FINAL CONFIGURATION. THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CALCULATIONS TO DETERMINE APPROPRIATE MATERIALS, LOADS, CODE COMPLIANCE REQUIREMENTS, ETC. 2. THE DESIGNER OF RECORD MUST PRESENT THE PROPOSED SOLUTION(S) DURING THE CDW TO ENSURE THAT IT IS CONSISTENT WITH THE DESIGN INTENT OF THE MCBCL THE DESIGNER OF RECORD MUST PRESENT THE PROPOSED SOLUTION(S) DURING THE CDW TO ENSURE THAT IT IS CONSISTENT WITH THE DESIGN INTENT OF THE MCBCL 3. THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CODE COMPLIANCE ANALYSIS BASED ON OCCUPANCY TO DETERMINE THE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES, REQUIRED EXITS, ETC. ALL THE FLOOR PLAN LAYOUTS MUST BE THE DESIGNER OF RECORD MUST PERFORM THE APPROPRIATE CODE COMPLIANCE ANALYSIS BASED ON OCCUPANCY TO DETERMINE THE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES, REQUIRED EXITS, ETC. ALL THE FLOOR PLAN LAYOUTS MUST BE APPROVED BY THE USER AT THE CDW. THIS APPLIES TO: THE SCOPE OF WORK (SOW) SHOWN WITHIN BLOCKED AREAS ON THE DRAWINGS DEVELOPED FLOOR PLAN LAYOUTS SHOWING FOR EXAMPLE: TOILET FIXTURES, FURNITURE, CABINETS, EXITS, ETC. ARE GENERIC IN NATURE AND NOT THE FINAL CONFIGURATION 4. NOTES SHOWN WITH TYPICAL (TYP) INDICATES CONDITIONS THAT OCCUR MULTIPLE TIMES NOTES SHOWN WITH TYPICAL (TYP) INDICATES CONDITIONS THAT OCCUR MULTIPLE TIMES 5. COMPLETE DEMOLITION OF INTERIOR CONDITIONS INCLUDES: WOOD OR METAL STUDS OR OTHER MATERIALS, GWB, PLASTER, FURRING FRAMING, FLOORING, BASE, CEILING, PLUMBING, HVAC, ELECTRICAL, SPRINKLER SYSTEMS, ETC. COMPLETE DEMOLITION OF INTERIOR CONDITIONS INCLUDES: WOOD OR METAL STUDS OR OTHER MATERIALS, GWB, PLASTER, FURRING FRAMING, FLOORING, BASE, CEILING, PLUMBING, HVAC, ELECTRICAL, SPRINKLER SYSTEMS, ETC. 6. THE BUILDINGS IN THIS PROJECT ARE HISTORICAL STRUCTURES. ALL EXTERIOR NEW EXTERIOR ITEMS MUST MATCH EXISTING DESIGN AESTHETICS. THE DESIGNER OF RECORD MUST SUBMIT DESIGN INTENT TO BE REVIEWED DURING THE CDW-PHASE THE BUILDINGS IN THIS PROJECT ARE HISTORICAL STRUCTURES. ALL EXTERIOR NEW EXTERIOR ITEMS MUST MATCH EXISTING DESIGN AESTHETICS. THE DESIGNER OF RECORD MUST SUBMIT DESIGN INTENT TO BE REVIEWED DURING THE CDW-PHASE 7. THE ASHRAE 90.1 -2016 REQUIREMENTS SHOWN IN SHEET A101 ARE APPLICABLE TO ALL THE BUILDINGS INCLUDED IN THIS PROJECTTHE ASHRAE 90.1 -2016 REQUIREMENTS SHOWN IN SHEET A101 ARE APPLICABLE TO ALL THE BUILDINGS INCLUDED IN THIS PROJECT

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

NOTE

AutoCAD SHX Text

DEMO NOTE

AutoCAD SHX Text

RENO NOTE

AutoCAD SHX Text

RFS

AutoCAD SHX Text

WALL TYPE

AutoCAD SHX Text EXTERIOR BRICK REPAIR WORK FOR ALL BUILDINGS INCLUDED IN THIS PROJECT: 1. REMOVE ANY EFFLORESCENCE WITH SPECIFICALLY FORMULATED PRODUCT FOR USE ON BRICK REMOVE ANY EFFLORESCENCE WITH SPECIFICALLY FORMULATED PRODUCT FOR USE ON BRICK 2. POWER WASH ALL FACADES TO REMOVE MOLD, VEGETATION GROWTH, PAINTED SURFACES, ETC. POWER WASH ALL FACADES TO REMOVE MOLD, VEGETATION GROWTH, PAINTED SURFACES, ETC. 3. REPLACE BROKEN AND HEAVILY DAMAGED AND SPALLED BRICK. LIMITED APPLICATION AREA-BID QUANTITY FOR REPLACE BROKEN AND HEAVILY DAMAGED AND SPALLED BRICK. LIMITED APPLICATION AREA-BID QUANTITY FOR EACH BUILDING AS FOLLOWS: RR1: 100 SF RR4: 100 SF RR8: 100 SF RR20: 10 SF RR22: 10 SF RR24: 10 SF 4. MORTAR JOINT REPAIR INCLUDES, CRACKED OR DETERIORATED MORTAR JOINTS, HAIRLINE CRACKS, LOOSE MORTAR, MORTAR JOINT REPAIR INCLUDES, CRACKED OR DETERIORATED MORTAR JOINTS, HAIRLINE CRACKS, LOOSE MORTAR, INCOMPLETE MORTAR FILLING, ETC. . LIMITED APPLICATION AREA-BID QUANTITY FOR EACH BUILDING RE-POINTING AS FOLLOWS: RR1: 20,000 LF RR4: 20,000 LF RR8: 10,000 LF RR20: 7,000 LF RR22: 7,000 LF RR24: 7,000 LF 5. APPLY TO ALL FACADES WATER REPELLENT PRODUCT THAT PERMIT EVAPORATION AND THE PASSAGE OF WATER APPLY TO ALL FACADES WATER REPELLENT PRODUCT THAT PERMIT EVAPORATION AND THE PASSAGE OF WATER VAPOR, FOR EXAMPLES PRODUCTS CONTAINING SILOXANES AND SILANES 6. THE QUANTITIES SHOWN ABOVE DO NOT INCLUDE THE BRICK RELATED WORK NECESSARY FOR THE REPLACEMENT THE QUANTITIES SHOWN ABOVE DO NOT INCLUDE THE BRICK RELATED WORK NECESSARY FOR THE REPLACEMENT OF LINTELS FOR EXTERIOR OPENINGS

AutoCAD SHX Text EXTERIOR BRICK REPAIR WORK FOR ALL BUILDINGS INCLUDED IN THIS PROJECT: 1. REMOVE ANY EFFLORESCENCE WITH SPECIFICALLY FORMULATED PRODUCT FOR USE ON BRICK REMOVE ANY EFFLORESCENCE WITH SPECIFICALLY FORMULATED PRODUCT FOR USE ON BRICK 2. POWER WASH ALL FACADES TO REMOVE MOLD, VEGETATION GROWTH, PAINTED SURFACES, ETC. POWER WASH ALL FACADES TO REMOVE MOLD, VEGETATION GROWTH, PAINTED SURFACES, ETC. 3. REPLACE BROKEN AND HEAVILY DAMAGED AND SPALLED BRICK. LIMITED APPLICATION AREA-BID QUANTITY FOR REPLACE BROKEN AND HEAVILY DAMAGED AND SPALLED BRICK. LIMITED APPLICATION AREA-BID QUANTITY FOR EACH BUILDING AS FOLLOWS: RR1: 100 SF RR4: 100 SF RR8: 100 SF RR20: 10 SF RR22: 10 SF RR24: 10 SF 4. MORTAR JOINT REPAIR INCLUDES, CRACKED OR DETERIORATED MORTAR JOINTS, HAIRLINE CRACKS, LOOSE MORTAR, MORTAR JOINT REPAIR INCLUDES, CRACKED OR DETERIORATED MORTAR JOINTS, HAIRLINE CRACKS, LOOSE MORTAR, INCOMPLETE MORTAR FILLING, ETC. . LIMITED APPLICATION AREA-BID QUANTITY FOR EACH BUILDING RE-POINTING AS FOLLOWS: RR1: 20,000 LF RR4: 20,000 LF RR8: 10,000 LF RR20: 7,000 LF RR22: 7,000 LF RR24: 7,000 LF 5. APPLY TO ALL FACADES WATER REPELLENT PRODUCT THAT PERMIT EVAPORATION AND THE PASSAGE OF WATER APPLY TO ALL FACADES WATER REPELLENT PRODUCT THAT PERMIT EVAPORATION AND THE PASSAGE OF WATER VAPOR, FOR EXAMPLES PRODUCTS CONTAINING SILOXANES AND SILANES 6. THE QUANTITIES SHOWN ABOVE DO NOT INCLUDE THE BRICK RELATED WORK NECESSARY FOR THE REPLACEMENT THE QUANTITIES SHOWN ABOVE DO NOT INCLUDE THE BRICK RELATED WORK NECESSARY FOR THE REPLACEMENT OF LINTELS FOR EXTERIOR OPENINGS

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text 80091

AutoCAD SHX Text E1

AutoCAD SHX Text

MARINE CORPS BASE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

CAMP LEJEUNE, NORTH CAROLINA

AutoCAD SHX Text

DESIGN DIR.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

CODE IDENT. NO

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SATISFACTORY TO:

AutoCAD SHX Text

APPROVED: PWO OR OICC:

AutoCAD SHX Text

DR.

AutoCAD SHX Text

DES.

AutoCAD SHX Text

CHK.

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NA

AutoCAD SHX Text

NOTED

AutoCAD SHX Text 19-0168

AutoCAD SHX Text

60XXXX

AutoCAD SHX Text

LEGENDS AND NOTES

AutoCAD SHX Text Db LCH4022 & 2600

AutoCAD SHX Text

FIRE STATIONS REPAIRS

AutoCAD SHX Text PWO or OICC

AutoCAD SHX Text

23APR2020

AutoCAD SHX Text

PWO OR OICC

AutoCAD SHX Text

THOMAS BURTON

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text

GUSTAVO DE LUCA

AutoCAD SHX Text A100

AutoCAD SHX Text

FINISH SCHEDULE

AutoCAD SHX Text

MARK

AutoCAD SHX Text

LOCATION

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

BASE

AutoCAD SHX Text

WALLS

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

NOTES

AutoCAD SHX Text A

AutoCAD SHX Text

SLEEP ROOM

AutoCAD SHX Text

CARPET

AutoCAD SHX Text

RESILIENT BASE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

ACOUSTIC TILE

AutoCAD SHX Text B

AutoCAD SHX Text

LAUNDRY, COMM ROOM

AutoCAD SHX Text

LVT

AutoCAD SHX Text

RESILIENT BASE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

ACOUSTIC TILE

AutoCAD SHX Text C

AutoCAD SHX Text

HEADS

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

GWB (PAINTED)

AutoCAD SHX Text CERAMIC TILE HEIGHT: FROM FLOOR TO CEILING. FLOOR MOUNTED LOCKER BENCHES. HPDE TOILET, URINALS, SHOWER PARTITIONS/SCREENS

AutoCAD SHX Text D

AutoCAD SHX Text

MECHANICAL ROOMS

AutoCAD SHX Text

CONCRETE W/ SEALER

AutoCAD SHX Text

NONE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

NONE

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

JANITOR CLOSET

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

CERAMIC TILE

AutoCAD SHX Text

CERAMIC TILE WAINSCOT/GWB (PAINTED)

AutoCAD SHX Text CERAMIC TILE WAINSCOT HEIGHT: 7'-0" TWO WALLS AT MOP SINK; CERAMIC TILE BASE ALL OTHER WALLS

AutoCAD SHX Text F

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

LVT

AutoCAD SHX Text

RESILIENT BASE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

ACOUSTIC TILE

AutoCAD SHX Text

GARAGE BAY

AutoCAD SHX Text

SEALED CONCRETE

AutoCAD SHX Text

NONE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text

LVT

AutoCAD SHX Text

RESILIENT BASE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

ACOUSTIC TILE

AutoCAD SHX Text

ENTRY

AutoCAD SHX Text

LVT

AutoCAD SHX Text

RESILIENT BASE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

ACOUSTIC TILE

AutoCAD SHX Text

PT ROOM

AutoCAD SHX Text

SEE NOTE 9 IN SHEETS A101 AND A102 AND NOTE 11 IN A103 AND A104

AutoCAD SHX Text THE RFP-DOCUMENTS (RFPD), INCLUDING BUT NOT LIMITED TO: THE DRAWINGS, PLANS, DESIGNS, REPORTS, SURVEYS, CALCULATIONS, COMPUTER PRINT-OUTS, ETC. ARE MADE AVAILABLE TO THE CONTRACTOR'S FOR REFERENCE PURPOSES ONLY IN RELATION TO THIS DESIGN-BID PROJECT. THE RFPD ARE THE PROPERTY OF THE GOVERNMENT. THE RFPD ARE PROVIDED "AS IS" WITHOUT ANY GUARANTEE, REPRESENTATION, CONDITION, OR WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, OR STATUTORY. THE GOVERNMENT ASSUMES NO LIABILITY WITH RESPECT TO ANY RELIANCE THE CONTRACTOR(S) PLACE ON THESE RFPD. IF THE CONTRACTOR(S) RELY ON THESE RFPD IN ANY WAY, THE CONTRACTOR(S) ASSUME THE ENTIRE RISK AS TO THE TRUTH, ACCURACY, CURRENCY, OR COMPLETENESS OF THE INFORMATION CONTAINED IN THESE RFPD.

Sheets and Views
A100 Cover

File details come from the government source that posted it. Updated .