J-0200000-15_ELINs.xls
XLS spreadsheet 554 KB Posted
- Solicitation number
- N4008519R9038
About this file
This pre-solicitation notice describes a requirements contract for facility investment services including preventive maintenance, repair, alteration, demolition and minor construction of interior and exterior doors at various Navy installations. Services will include emergency and routine service orders, preventative maintenance of overhead doors, sliding doors, bi-fold doors and hangar doors. The contract will have a one year base period and four one-year options, not exceeding 60 months total. The procurement will use an LPTA source selection evaluating price and technical factors including technical approach, corporate experience, safety, and past performance. Projects submitted for experience must be over $2M annually involving similar door maintenance scope. The RFP will be available on NECO on March 28th with a proposal due date at least 30 days later. The NAICS code is 238290 and it is set aside for small business. Acceptance of purchase cards and FedMall software is required for ordering.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Section_J-0200000_-_Additional_Attachments.zip | ZIP file | |
| RFP_N4008519R9038_OVERHEAD_DOORS.pdf | ||
| N4008519R9038_Presolicitation_Notice_N4008519R9038.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUMMARY
| CLIN 0001 | CLIN 0002 | |
| CLIN 0003 | CLIN 0004 | |
| CLIN 0005 | CLIN 0006 | |
| CLIN 0007 | CLIN 0008 | |
| CLIN 0009 | CLIN 0010 | |
| Total RP | Total NRP | |
| Est. Total |
Recurring-Base Period
| ATTACHMENT J-0200000-15 | |||||
| EXHIBIT LINE ITEM NUMBERS | |||||
| SOLICITATION/CONTRACT N40085-19-R-9038 | |||||
| EXHIBIT A | |||||
| Line Item 0001 Recurring Price - Base Period | |||||
| PROVIDE PRICES FOR FACILITY INVESTMENT - RECURRING PRICE - IN ACCORDANCE WITH SECTION C, SPEC ITEM 3 | |||||
| ELINs A001 through A022 | |||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total |
| A001 | NNSY CIA Spec Item 3 | ||||
| A001AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A001AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A001AC | Routine Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A001AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 173 | EA | ||
| A001AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 6 | EA | ||
| A001AF | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 1 | EA | ||
| A001AG | PM Program, Overhead Metal Doors 1,501-2,000 SF Spec Item 3.2.1 | 1 | EA | ||
| A00AH | PM Program, Overhead Metal Doors 2,001-3,000 SF Spec Item 3.2.1 | 3 | EA | ||
| A001AJ | PM Program, Curtain DoorsSpec Item 3.2.1 | 1 | |||
| A001AK | PM Program, Sliding Doors Spec Item 3.2.2 | 8 | EA | ||
| A001AL | Reserved for Future Use | ||||
| A001AM | Reserved for Future Use | ||||
| A002 | Facility Management 1501000 | ||||
| A002AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NNSY CIA Subtotal | |||||
| A003 | NNSY NON-CIA Spec Item 3 | ||||
| A003AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A003AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A003AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A003AD | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 202 | EA | ||
| A003AE | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 1 | EA | ||
| A003AF | PM Program, Canvas Doors Spec Item 3.2.1 | 2 | EA | ||
| A003AG | PM Program, Sliding Doors Spec Item 3.2.2 | 6 | EA | ||
| A003AH | PM Program, Bi-Fold DoorsSpec Item 3.2.3 | 3 | EA | ||
| A003AJ | Reserved for Future Use | ||||
| A003AK | Reserved for Future Use | ||||
| A004 | Facility Management 1501000 | ||||
| A004AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NNSY NON-CIA Subtotal | |||||
| A005 | NUWC Spec Item 3 | ||||
| A005AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A005AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A005AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A005AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 5 | EA | ||
| A005AE | Reserved for Future Use | ||||
| A005AF | Reserved for Future Use | ||||
| A006 | Facility Management 1501000 | ||||
| A006AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NUWC Subtotal | |||||
| A007 | DECA Spec Item 3 | ||||
| A007AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A007AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A007AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A007AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 10 | EA | ||
| A007AE | Reserved for Future Use | ||||
| A007AF | Reserved for Future Use | ||||
| A008 | Facility Management 1501000 | ||||
| A008AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| DECA Subtotal | |||||
| A009 | NSWCCD Spec Item 3 | ||||
| A009AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A009AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A009AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A009AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 2 | EA | ||
| A009AE | Reserved for Future Use | ||||
| A009AF | Reserved for Future Use | ||||
| A010 | Facility Management 1501000 | ||||
| A010AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NSWCCD Subtotal | |||||
| A011 | SPAWAR Spec Item 3 | ||||
| A011AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A011AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A011AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A011AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 12 | EA | ||
| A011AE | Reserved for Future Use | ||||
| A011AF | Reserved for Future Use | ||||
| A012 | Facility Management 1501000 | ||||
| A012AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| SPAWAR Subtotal | |||||
| A013 | DLA Spec Item 3 | ||||
| A013AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A013AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A013AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A013AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 8 | EA | ||
| A013AE | Reserved for Future Use | ||||
| A013AF | Reserved for Future Use | ||||
| A014 | Facility Management 1501000 | ||||
| A014AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| DLA Subtotal | |||||
| A015 | Little Creek/ Fort Story Spec Item 3 | ||||
| A015AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A015AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A015AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A015AD | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 4 | EA | ||
| A015AE | PM Program, Sliding Metal Hanger Bay Doors Spec Item 3.2.4 | 4 | EA | ||
| A015AF | Reserved for Future Use | ||||
| A015AG | Reserved for Future Use | ||||
| A016 | Facility Management 1501000 | ||||
| A016AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Little Creek/Fort Story Subtotal | |||||
| A017 | Naval Weapons Station(YRKT)/ Cheatham Annex(CAX) Spec Item 3 | ||||
| A017AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A017AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A017AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A017AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 254 | EA | ||
| A017AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 1 | EA | ||
| A017AF | PM Program, Sliding Fire Doors Spec Item 3.2.5 | 14 | EA | ||
| A017AG | Reserved for Future Use | ||||
| A017AH | Reserved for Future Use | ||||
| A018 | Facility Management 1501000 | ||||
| A018AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Naval Weapons Station(YRKT)/Cheatham Annex(CAX) Subtotal | |||||
| A019 | Oceana/Dam Neck Spec Item 3 | ||||
| A019AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A019AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A019AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A019AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 8 | EA | ||
| A019AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 105 | EA | ||
| A019AF | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 32 | EA | ||
| A019AG | PM Program, Overhead Metal Doors 1,501-2,000 SF Spec Item 3.2.1 | 5 | EA | ||
| A019AH | Reserved for Future Use | ||||
| A019AJ | Reserved for Future Use | ||||
| A020 | Facility Management 1501000 | ||||
| A020AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Oceana/Dam Neck Subtotal | |||||
| A021 | Naval Base Norfolk Spec Item 3 | ||||
| A021AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| A021AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| A021AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| A021AD | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 53 | EA | ||
| A021AE | Reserved for Future Use | ||||
| A021AF | Reserved for Future Use | ||||
| A022 | Facility Management 1501000 | ||||
| A022AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Naval Base Norfolk Subtotal | |||||
| TOTAL FFP LINE ITEMS |
SECTION J
EXHIBIT A
PROVIDE PRICES TO MAINTAIN GROUNDS - FIRM FIXED PRICE
IN ACCORDANCE WITH SECTION C, Items 3.1, 3.2, 3.3, and 3.4 ELIN A001 through A0015 Line Item 0001 Base Year - Firm Fixed Price ELIN A001 through A0015
SECTION J
EXHIBIT A
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Barbwire Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Ornamental Steel Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Wood Fence.
PROVIDE A UNIT PRICE FOR THE REMOVAL AND DISPOSAL OF FENCE COMPLETE, FENCE POSTS, BARBWIRE, BARBED TAPE.
IN ACCORDANCE WITH SECTION C, C.10.1.l
ELIN A001EW through A001FI Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence.
Including Fabric, Posts, Gates, Rails, Tension Wire, Barbwire/Barbed Tape.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence Gates including tracks (not posts).
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Ornamental Steel Fence. Including Posts and Gates Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Wood Fence. Including Posts and Gates.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Barbwire Fence. Including Posts and all wire.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Post Cut-off Flush.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Driven Post.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Posts Set in Concrete/Asphalt.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Square Foot to Patch and Refinish Concrete or Asphalt Surface.
Surface Depth to Match Surrounding.
Unit Price Each to Remove and Dispose of or Save and Store (for reuse) Barbwire Single Arm Support.
Unit Price Each to remove and Dispose of or Save and Store (for reuse) Barbwire Double (V) Arm Support.
Lump Sum Price for the recycling of removed materials. Based on a Percentage Added to Removal Item Ordered
SECTION J
EXHIBIT A
Lump Sum Price for the Recycling of Removed Materials. Based on a Percentage Added to Removal Item Ordered, ELIN A001EK to A001EW. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
PROVIDE A UNIT PRICE TO PERFORM EXPEDITED SERVICES.
IN ACCORDANCE WITH SECTION C, C.10.2
ELIN A001FJ
Lump Sum Price for Expedited Maintenance and Repair Services. Based on a Percentage Added to Task Order Total. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
SECTION J
EXHIBIT A
SECTION J
EXHIBIT A
PROVIDE A UNIT PRICE FOR THE RENTAL OF TEMPORARY CHAIN LINK FENCE.
IN ACCORDANCE WITH SECTION C, C.10.3
ELIN A001FK THROUGH A001FP
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
6' Fence Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, 6' Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, 6' Height, Free-Standing Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
Driven Posts With Barbwire, 7' Fence Height Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, With Barbwire, 7' Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, With Barbwire, 7' Height, Free-Standing Line Item 0002 Base Year - Indefinite Quantity Work ELIN A0016 through A0030
PROVIDE UNIT PRICES FOR INDEFINITE QUANTITY WORK
IN ACCORDANCE WITH SECTION C, Item 4 ELIN A0016 through A0030
Non-Recurring-Base Period
| ATTACHMENT J-0200000-15 | ||||||
| EXHIBIT LINE ITEM NUMBERS | ||||||
| SOLICITATION/CONTRACT # N40085-19-R-9038 | ||||||
| EXHIBIT A | ||||||
| Line Item 0002 Non-Recurring Price - Base Period | ||||||
| PROVIDE PRICES FOR FACILITY INVESTMENT - NON-RECURRING QUANTITY - IN ACCORDANCE WITH SECTION C, SPEC ITEM 4 | ||||||
| ELINs A700 through A817 | ||||||
| ELIN | Product Name (120 Characters) | Description Extended | Estimated Quantity | Unit of Issue | Unit Price | Extended Price |
| A700 | Demolition/Removal | Door Frame Metal/ Wood/ single/ double | 122 | EA | ||
| A701 | Demolition/Removal | Personnel Door Including all Hardware | 315 | EA | ||
| A702 | Demolition/Removal | Rolling Steel / Overhead Steel/ ALUM/ Wooden Doors | 88 | EA | ||
| A703 | Demolition/Removal | New Opening in Masonry Walls Including New Lintel Concrete / Steel | 449 | SF | ||
| A704 | Demolition/Removal | New Opening in Concrete Walls Reinforced and Non-Reinforced, Including New Lintel Concrete / Steel | 287 | SF | ||
| A705 | Demolition/Removal | New Opening in Wood/Metal Frame Wall, Including Header and all Sub-Frame Work (thickness 1 framing member + finish on both sides) | 635 | SF | ||
| A706 | Asbestos | Materials Containing Asbestos, Removal and Disposal | 553 | SF | ||
| A707 | Asbestos | Asbestos Sampeling | 43 | EA | ||
| A708 | Lead Based Paint | Materials Containing Lead Based Paint, Removal and Clean Up | 1809 | SF | ||
| A709 | Lead Based Paint | Disposal of Materials Containing Lead Based Paint (Hazardous Waste) | 941 | LB | ||
| A710 | TCLP Testing | TCLP Testing | 25 | EA | ||
| A711 | Reserved for Future Use | |||||
| A712 | Reserved for Future Use | |||||
| A713 | Rolling Steel Service Door | Rolling Steel Door 0 to 256 SF | 10631 | SF | ||
| A714 | Rolling Steel Service Door | Rolling Steel Door 257 SF and above | 7739 | SF | ||
| A715 | Rolling Steel Service Door | Electrical Operator for doors 0 to 256 SF | 60 | EA | ||
| A716 | Rolling Steel Service Door | Electrical Operator for doors 257 SF and above | 23 | EA | ||
| A717 | Rolling Steel Service Door | Additional Control Station, Exterior with Key Locking Device | 27 | EA | ||
| A718 | Rolling Steel Service Door | Exterior Mounting | 14 | EA | ||
| A719 | Rolling Steel Service Door | Rolling Fire Door 1-1/2 / 3 /4 Hour UL label (for masonary walls) chain hoist | 2000 | SF | ||
| A720 | Rolling Steel Service Door | Add on for insulated Rolling Steel Service Door per SF. | 8000 | SF | ||
| A721 | Reserved for Future Use | |||||
| A722 | Reserved for Future Use | |||||
| A723 | OVERHEAD STEEL DOOR | Basic Overhead Steel Door 16 / 20 / 24 ga | 2795 | SF | ||
| A724 | OVERHEAD STEEL DOOR | Add For Insulated Overhead Steel Door 16 / 20 / 24 ga | 1280 | SF | ||
| A725 | OVERHEAD STEEL DOOR | Optional High Lift (All Doors) | 12 | EA | ||
| A726 | OVERHEAD STEEL DOOR | Optional Vertical Lift (All Doors) | 12 | EA | ||
| A727 | OVERHEAD STEEL DOOR | Manual - Chain Operation (All Doors) | 26 | EA | ||
| A728 | OVERHEAD STEEL DOOR | Electrical Operators for Doors 16 \ 20 \ 24ga | 30 | EA | ||
| A729 | OVERHEAD STEEL DOOR | Additional Control station exterior with locking device (All Doors) | 9 | EA | ||
| A730 | OVERHEAD STEEL DOOR | Vision Panels (All Doors) | 255 | SF | ||
| A731 | Reserved for Future Use | |||||
| A732 | Reserved for Future Use | |||||
| A733 | Overhead Aluminum Door | Basic Overhead Aluminum Door .050ga- Interior Mounted - anodized - Std lift Manual Lift Operation and painted | 3222 | SF | ||
| A734 | Overhead Aluminum Door | Optional High Lift | 15 | EA | ||
| A735 | Overhead Aluminum Door | Optional Vertical Lift | 9 | EA | ||
| A736 | Overhead Aluminum Door | Manual - Chain Operation | 20 | EA | ||
| A737 | Overhead Aluminum Door | Electrical Operator ( | 17 | EA | ||
| A738 | Overhead Aluminum Door | Additional control station exterior with locking device | 11 | EA | ||
| A739 | Overhead Aluminum Door | Vision Panels | 833 | SF | ||
| A740 | Overhead Aluminum Door | Add on for insulated Overhead Aluminum Door per SF. | 2000 | SF | ||
| A741 | Reserved for Future Use | |||||
| A742 | Reserved for Future Use | |||||
| A743 | STANDARD FLUSH STEEL DOOR 1-3/4 | 2'8" x 6'8" | 16 | EA | ||
| A744 | STANDARD FLUSH STEEL DOOR 1-3/4 | 3'0" x 6'8" | 87 | EA | ||
| A745 | STANDARD FLUSH STEEL DOOR 1-3/4 | 4'0" x 6'8" | 8 | EA | ||
| A746 | STANDARD FLUSH STEEL DOOR 1-3/4 | 3'0" x 7'0" | 133 | EA | ||
| A747 | Reserved for Future Use | |||||
| A748 | Reserved for Future Use | |||||
| A749 | NON-STANDARD FLUSH DOORS 1-3/4" | Less than 3'0" x 6'8" | 30 | EA | ||
| A750 | NON-STANDARD FLUSH DOORS 1-3/4" | Greater than 3'0" x 6'8" | 42 | EA | ||
| A751 | NON-STANDARD FLUSH DOORS 1-3/4" | Less than 3'0" x 7'0" | 29 | EA | ||
| A752 | NON-STANDARD FLUSH DOORS 1-3/4" | Greater than 3'0" x 7'0" | 13 | EA | ||
| A753 | NON-STANDARD FLUSH DOORS 1-3/4" | Less than 3'0" x 8'0" | 12 | EA | ||
| A754 | NON-STANDARD FLUSH DOORS 1-3/4" | Greater than 3'0" x 8'0" | 13 | EA | ||
| A755 | Reserved for Future Use | |||||
| A756 | Reserved for Future Use | |||||
| A757 | VISION PANELS IN DOORS | Choice Of Vision Panels 10" x 10" | 125 | EA | ||
| A758 | VISION PANELS IN DOORS | Choice Of Vision Panels 5-5/8" x 20" | 35 | EA | ||
| A759 | VISION PANELS IN DOORS | Various Opening Sizes Per Square Foot | 804 | SF | ||
| A760 | Reserved for Future Use | |||||
| A761 | TRANSOMS & SIDE LITES FOR METAL DOORS WITH METAL FRAMES COMPLETE WITH GLAZING AS FOLLOWS: | with Insulated Metal Panel painted to match | 181 | SF | ||
| A762 | TRANSOMS & SIDE LITES FOR METAL DOORS WITH METAL FRAMES COMPLETE WITH GLAZING AS FOLLOWS: | with 1" Insulated Tempered Glass | 186 | SF | ||
| A763 | Reserved for Future Use | |||||
| A764 | LOUVERS INSTALLED IN METAL DOORS | 18-3/4" x 14" | 9 | EA | ||
| A765 | LOUVERS INSTALLED IN METAL DOORS | 24-3/4" x 14" | 6 | EA | ||
| A766 | LOUVERS INSTALLED IN METAL DOORS | 24" x 24" | 29 | EA | ||
| A767 | LOUVERS INSTALLED IN METAL DOORS | Non Standard louver Size | 110 | SF | ||
| A768 | Reserved for Future Use | |||||
| A769 | BASIC HOLLOW METAL FRAMES | Single Door Opening - Welded Type | 40 | EA | ||
| A770 | BASIC HOLLOW METAL FRAMES | Double Door Opening - Welded Type | 30 | EA | ||
| A771 | BASIC HOLLOW METAL FRAMES | Single Door Opening - Knock Down Type | 89 | EA | ||
| A772 | BASIC HOLLOW METAL FRAMES | Double Door Opening - Knock Down Type | 58 | EA | ||
| A773 | BASIC HOLLOW METAL FRAMES | Add on for Fire Rated Doors and Frame 3/4 / 1-1/2 / 3 hours | 67 | EA | ||
| A774 | Reserved for Future Use | |||||
| A775 | FINISH HARDWARE - HINGES | Brass Hinges Mortise Heavy Wt 4-1/2-4-1/2 | 112 | EA | ||
| A776 | FINISH HARDWARE - HINGES | Stainless Steel Hinges Mortise Heavy Wt 4-1/2-4-1/2 | 573 | EA | ||
| A777 | FINISH HARDWARE - HINGES | Brass Hinges Mortise Heavy Wt 5"- 5" | 16 | EA | ||
| A778 | FINISH HARDWARE - HINGES | Stainless Steel Hinges Mortise Heavy Wt 5"- 5" | 46 | EA | ||
| A779 | FINISH HARDWARE - HINGES | Continuous Hinge - Gear Type (Clear Natural Finish) | 250 | LF | ||
| A780 | FINISH HARDWARE - HINGES | Continuous Hinge - Gear Type (Bronze Anodized Finish) | 210 | LF | ||
| A781 | Reserved for Future Use | |||||
| A782 | LOCKS & LATCHES | F75 Passage or closet latch | 131 | EA | ||
| A783 | LOCKS & LATCHES | F82 Entry Lock | 165 | EA | ||
| A784 | LOCKS & LATCHES | F86 Store Room or closet lock | 30 | EA | ||
| A785 | LOCKS & LATCHES | Dead Bolt Lock (single cylinder) | 44 | EA | ||
| A786 | LOCKS & LATCHES | L1000 Mechanical Push Button System with Lever operation and Options | 45 | EA | ||
| A787 | LOCKS & LATCHES | Electrical Cypher Lock with Electrical strike and options | 21 | EA | ||
| A788 | Reserved for Future Use | |||||
| A789 | EXIT DOOR HARDWARE | Rim Type Panic Hardware (exit Device) | 125 | EA | ||
| A790 | EXIT DOOR HARDWARE | Vertical Rod Panic Hardware (exit Device) | 73 | EA | ||
| A791 | EXIT DOOR HARDWARE | Hardware for labeled Fire Doors and Exit Doors (Add) | 50 | EA | ||
| A792 | Reserved for Future Use | |||||
| A793 | MISCELLANEOUS DOOR HARDWARE | Thresholds | 188 | EA | ||
| A794 | MISCELLANEOUS DOOR HARDWARE | Door Bolts | 87 | EA | ||
| A795 | MISCELLANEOUS DOOR HARDWARE | Surface Door Closures | 350 | EA | ||
| A796 | MISCELLANEOUS DOOR HARDWARE | Door Pulls | 61 | EA | ||
| A797 | MISCELLANEOUS DOOR HARDWARE | Push Plates | 47 | EA | ||
| A798 | MISCELLANEOUS DOOR HARDWARE | Bars | 26 | EA | ||
| A799 | MISCELLANEOUS DOOR HARDWARE | Astragals | 93 | EA | ||
| A800 | MISCELLANEOUS DOOR HARDWARE | Weather Stripping | 4219 | LF | ||
| A801 | MISCELLANEOUS DOOR HARDWARE | Door Coordinator | 64 | EA | ||
| A802 | MISCELLANEOUS DOOR HARDWARE | Kick Plates | 114 | EA | ||
| A803 | MISCELLANEOUS DOOR HARDWARE | Mop Plates | 16 | EA | ||
| A804 | MISCELLANEOUS DOOR HARDWARE | Edge Guards | 17 | EA | ||
| A805 | MISCELLANEOUS DOOR HARDWARE | Door Sweep | 181 | EA | ||
| A806 | MISCELLANEOUS DOOR HARDWARE | Door Sweep | 181 | LF | ||
| A807 | MISCELLANEOUS DOOR HARDWARE | Removable Mullion | 8 | EA | ||
| A808 | MISCELLANEOUS DOOR HARDWARE | Fixed Mullion | 10 | EA | ||
| A809 | Reserved for Future Use | |||||
| A810 | MISCELLANEOUS WORK | Painting Existing Door Frame | 2479 | SF | ||
| A811 | MISCELLANEOUS WORK | Install Up to 3/4" Conduit and 4 wires from power panel to electric operated door location (includes breaker for panel and disconnect switch at door) | 1881 | LF | ||
| A812 | MISCELLANEOUS WORK | Lumber for Mounting Frames (Salt Treated) Includes Installation | 251 | BF | ||
| A813 | Reserved for Future Use | |||||
| A814 | Unit Priced Labor Work - MUST BE NEGOTIATED BY KO. | Provide labor to perform all Unit Priced Labor work subject to the Service Contract Act per the scope and delivery schedule specified in the order. | 1300 | HR | ||
| A815 | Unit Priced Labor Work - MUST BE NEGOTIATED BY KO. | Provide labor to perform all Unit Priced Labor work subject to the Davis Bacon Act per the scope and delivery schedule specified in the order. | 1300 | HR | ||
| A816 | Material Costs- MUST BE NEGOTIATED BY KO. | Provide all materials and equipment to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use with ELIN A702. | 1 | NTE | ||
| A817 | Engineering Studies - MUST BE NEGOTIATED BY KO | The Contractor shall provide an engineering study of an existing condition or proposed situation, e.g., installation traffic, land use, alternative site investigation, and AICUZ, as requested by an internal or external customer. Services shall include research of applicable regulations, site investigation, and preparation of a written report indicating background, findings, and recommendation(s), complete with supporting graphics, e.g., sketches and drawings, and a detailed cost estimate of the recommended maintenance, repair or construction work. Necessary copies of a pre-final report shall be provided to the requestor and any impacted customers for review and comment incorporation prior to distribution of the final copy. All services shall be completed within the time specified in the task order. | 80 | HR | ||
| TOTAL INDEFINITE QUANTITY PRICE BASE YEAR |
Recurring-1st Opt Period
| ATTACHMENT J-0200000-15 | |||||
| EXHIBIT LINE ITEM NUMBERS | |||||
| SOLICITATION/CONTRACT N40085-19-R-9038 | |||||
| EXHIBIT B | |||||
| Line Item 0003 Recurring Price - First Opt Period | |||||
| PROVIDE PRICES FOR FACILITY INVESTMENT - RECURRING PRICE - IN ACCORDANCE WITH SECTION C, SPEC ITEM 3 | |||||
| ELINs B001 through B022 | |||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total |
| B001 | NNSY CIA Spec Item 3 | ||||
| B001AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B001AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B001AC | Routine Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B001AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 173 | EA | ||
| B001AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 6 | EA | ||
| B001AF | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 1 | EA | ||
| B001AG | PM Program, Overhead Metal Doors 1,501-2,000 SF Spec Item 3.2.1 | 1 | EA | ||
| B00AH | PM Program, Overhead Metal Doors 2,001-3,000 SF Spec Item 3.2.1 | 3 | EA | ||
| B001AJ | PM Program, Curtain DoorsSpec Item 3.2.1 | 1 | |||
| B001AK | PM Program, Sliding Doors Spec Item 3.2.2 | 8 | EA | ||
| B001AL | Reserved for Future Use | ||||
| B001AM | Reserved for Future Use | ||||
| B002 | Facility Management 1501000 | ||||
| B002AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NNSY CIA Subtotal | |||||
| B003 | NNSY NON-CIA Spec Item 3 | ||||
| B003AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B003AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B003AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B003AD | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 202 | EA | ||
| B003AE | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 1 | EA | ||
| B003AF | PM Program, Canvas Doors Spec Item 3.2.1 | 2 | EA | ||
| B003AG | PM Program, Sliding Doors Spec Item 3.2.2 | 6 | EA | ||
| B003AH | PM Program, Bi-Fold DoorsSpec Item 3.2.3 | 3 | EA | ||
| B003AJ | Reserved for Future Use | ||||
| B003AK | Reserved for Future Use | ||||
| B004 | Facility Management 1501000 | ||||
| B004AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NNSY NON-CIA Subtotal | |||||
| B005 | NUWC Spec Item 3 | ||||
| B005AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B005AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B005AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B005AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 5 | EA | ||
| B005AE | Reserved for Future Use | ||||
| B005AF | Reserved for Future Use | ||||
| B006 | Facility Management 1501000 | ||||
| B006AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NUWC Subtotal | |||||
| B007 | DECA Spec Item 3 | ||||
| B007AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B007AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B007AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B007AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 10 | EA | ||
| B007AE | Reserved for Future Use | ||||
| B007AF | Reserved for Future Use | ||||
| B008 | Facility Management 1501000 | ||||
| B008AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| DECA Subtotal | |||||
| B009 | NSWCCD Spec Item 3 | ||||
| B009AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B009AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B009AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B009AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 2 | EA | ||
| B009AE | Reserved for Future Use | ||||
| B009AF | Reserved for Future Use | ||||
| B010 | Facility Management 1501000 | ||||
| B010AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NSWCCD Subtotal | |||||
| B011 | SPAWAR Spec Item 3 | ||||
| B011AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B011AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B011AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B011AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 12 | EA | ||
| B011AE | Reserved for Future Use | ||||
| B011AF | Reserved for Future Use | ||||
| B012 | Facility Management 1501000 | ||||
| B012AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| SPAWAR Subtotal | |||||
| B013 | DLA Spec Item 3 | ||||
| B013AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B013AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B013AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B013AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 8 | EA | ||
| B013AE | Reserved for Future Use | ||||
| B013AF | Reserved for Future Use | ||||
| B014 | Facility Management 1501000 | ||||
| B014AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| DLA Subtotal | |||||
| B015 | Little Creek/ Fort Story Spec Item 3 | ||||
| B015AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B015AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B015AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B015AD | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 4 | EA | ||
| B015AE | PM Program, Sliding Metal Hanger Bay Doors Spec Item 3.2.4 | 4 | EA | ||
| B015AF | Reserved for Future Use | ||||
| B015AG | Reserved for Future Use | ||||
| B016 | Facility Management 1501000 | ||||
| B016AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Little Creek/Fort Story Subtotal | |||||
| B017 | Naval Weapons Station(YRKT)/ Cheatham Annex(CAX) Spec Item 3 | ||||
| B017AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B017AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B017AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B017AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 254 | EA | ||
| B017AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 1 | EA | ||
| B017AF | PM Program, Sliding Fire Doors Spec Item 3.2.5 | 14 | EA | ||
| B017AG | Reserved for Future Use | ||||
| B017AH | Reserved for Future Use | ||||
| B018 | Facility Management 1501000 | ||||
| B018AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Naval Weapons Station(YRKT)/Cheatham Annex(CAX) Subtotal | |||||
| B019 | Oceana/Dam Neck Spec Item 3 | ||||
| B019AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B019AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B019AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B019AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 8 | EA | ||
| B019AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 105 | EA | ||
| B019AF | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 32 | EA | ||
| B019AG | PM Program, Overhead Metal Doors 1,501-2,000 SF Spec Item 3.2.1 | 5 | EA | ||
| B019AH | Reserved for Future Use | ||||
| B019AJ | Reserved for Future Use | ||||
| B020 | Facility Management 1501000 | ||||
| B020AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Oceana/Dam Neck Subtotal | |||||
| B021 | Naval Base Norfolk Spec Item 3 | ||||
| B021AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| B021AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| B021AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| B021AD | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 53 | EA | ||
| B021AE | Reserved for Future Use | ||||
| B021AF | Reserved for Future Use | ||||
| B022 | Facility Management 1501000 | ||||
| B022AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| Naval Base Norfolk Subtotal | |||||
| TOTAL FFP LINE ITEMS |
SECTION J
EXHIBIT A
PROVIDE PRICES TO MAINTAIN GROUNDS - FIRM FIXED PRICE
IN ACCORDANCE WITH SECTION C, Items 3.1, 3.2, 3.3, and 3.4 ELIN A001 through A0015 Line Item 0001 Base Year - Firm Fixed Price ELIN A001 through A0015
SECTION J
EXHIBIT A
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Barbwire Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Ornamental Steel Fence.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Reconditioning and Maintenance Service for Wood Fence.
PROVIDE A UNIT PRICE FOR THE REMOVAL AND DISPOSAL OF FENCE COMPLETE, FENCE POSTS, BARBWIRE, BARBED TAPE.
IN ACCORDANCE WITH SECTION C, C.10.1.l
ELIN A001EW through A001FI Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence.
Including Fabric, Posts, Gates, Rails, Tension Wire, Barbwire/Barbed Tape.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Chain link Fence Gates including tracks (not posts).
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Ornamental Steel Fence. Including Posts and Gates Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Wood Fence. Including Posts and Gates.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Removal Service for Barbwire Fence. Including Posts and all wire.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Post Cut-off Flush.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Driven Post.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Each to Provide Removal Service for Fence Posts. Including Posts Footing with Braces and Supports as Required.
Posts Set in Concrete/Asphalt.
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Square Foot to Patch and Refinish Concrete or Asphalt Surface.
Surface Depth to Match Surrounding.
Unit Price Each to Remove and Dispose of or Save and Store (for reuse) Barbwire Single Arm Support.
Unit Price Each to remove and Dispose of or Save and Store (for reuse) Barbwire Double (V) Arm Support.
Lump Sum Price for the recycling of removed materials. Based on a Percentage Added to Removal Item Ordered
SECTION J
EXHIBIT A
Lump Sum Price for the Recycling of Removed Materials. Based on a Percentage Added to Removal Item Ordered, ELIN A001EK to A001EW. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
PROVIDE A UNIT PRICE TO PERFORM EXPEDITED SERVICES.
IN ACCORDANCE WITH SECTION C, C.10.2
ELIN A001FJ
Lump Sum Price for Expedited Maintenance and Repair Services. Based on a Percentage Added to Task Order Total. Figured on a Quantity of 1,000. The Quantity Provided is for Establishing the Percentage Rate Only.
SECTION J
EXHIBIT A
SECTION J
EXHIBIT A
PROVIDE A UNIT PRICE FOR THE RENTAL OF TEMPORARY CHAIN LINK FENCE.
IN ACCORDANCE WITH SECTION C, C.10.3
ELIN A001FK THROUGH A001FP
Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
6' Fence Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, 6' Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, 6' Height, Free-Standing Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
Driven Posts With Barbwire, 7' Fence Height Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, With Barbwire, 7' Height Driven Posts Unit Price Per Linear Foot to Provide Red Wood or Cedar Fence Including Dog Ear Fence Boards, Posts, Rails, Braces and all Hardware.
Fence Board Height of 6' Unit Price Per Linear Foot to Provide Temporary Chain link Fence.
12' Panel, With Barbwire, 7' Height, Free-Standing Line Item 0002 Base Year - Indefinite Quantity Work ELIN A0016 through A0030
PROVIDE UNIT PRICES FOR INDEFINITE QUANTITY WORK
IN ACCORDANCE WITH SECTION C, Item 4 ELIN A0016 through A0030
Non-Recurring-1st Opt Period-
| ATTACHMENT J-0200000-15 | ||||||
| EXHIBIT LINE ITEM NUMBERS | ||||||
| SOLICITATION/CONTRACT # N40085-19-R-9038 | ||||||
| EXHIBIT B | ||||||
| Line Item 0004 Non-Recurring Price - First Option Period | ||||||
| PROVIDE PRICES FOR FACILITY INVESTMENT - NON-RECURRING QUANTITY - IN ACCORDANCE WITH SECTION C, SPEC ITEM 4 | ||||||
| ELINs B700 through B817 | ||||||
| ELIN | Product Name (120 Characters) | Description Extended | Estimated Quantity | Unit of Issue | Unit Price | Extended Price |
| B700 | Demolition/Removal | Door Frame Metal/ Wood/ single/ double | 122 | EA | ||
| B701 | Demolition/Removal | Personnel Door Including all Hardware | 315 | EA | ||
| B702 | Demolition/Removal | Rolling Steel / Overhead Steel/ ALUM/ Wooden Doors | 88 | EA | ||
| B703 | Demolition/Removal | New Opening in Masonry Walls Including New Lintel Concrete / Steel | 449 | SF | ||
| B704 | Demolition/Removal | New Opening in Concrete Walls Reinforced and Non-Reinforced, Including New Lintel Concrete / Steel | 287 | SF | ||
| B705 | Demolition/Removal | New Opening in Wood/Metal Frame Wall, Including Header and all Sub-Frame Work (thickness 1 framing member + finish on both sides) | 635 | SF | ||
| B706 | Asbestos | Materials Containing Asbestos, Removal and Disposal | 553 | SF | ||
| B707 | Asbestos | Asbestos Sampeling | 43 | EA | ||
| B708 | Lead Based Paint | Materials Containing Lead Based Paint, Removal and Clean Up | 1809 | SF | ||
| B709 | Lead Based Paint | Disposal of Materials Containing Lead Based Paint (Hazardous Waste) | 941 | LB | ||
| B710 | TCLP Testing | TCLP Testing | 25 | EA | ||
| B711 | Reserved for Future Use | |||||
| B712 | Reserved for Future Use | |||||
| B713 | Rolling Steel Service Door | Rolling Steel Door 0 to 256 SF | 10631 | SF | ||
| B714 | Rolling Steel Service Door | Rolling Steel Door 257 SF and above | 7739 | SF | ||
| B715 | Rolling Steel Service Door | Electrical Operator for doors 0 to 256 SF | 60 | EA | ||
| B716 | Rolling Steel Service Door | Electrical Operator for doors 257 SF and above | 23 | EA | ||
| B717 | Rolling Steel Service Door | Additional Control Station, Exterior with Key Locking Device | 27 | EA | ||
| B718 | Rolling Steel Service Door | Exterior Mounting | 14 | EA | ||
| B719 | Rolling Steel Service Door | Rolling Fire Door 1-1/2 / 3 /4 Hour UL label (for masonary walls) chain hoist | 2000 | SF | ||
| B720 | Rolling Steel Service Door | Add on for insulated Rolling Steel Service Door per SF. | 8000 | SF | ||
| B721 | Reserved for Future Use | |||||
| B722 | Reserved for Future Use | |||||
| B723 | OVERHEAD STEEL DOOR | Basic Overhead Steel Door 16 / 20 / 24 ga | 2795 | SF | ||
| B724 | OVERHEAD STEEL DOOR | Add For Insulated Overhead Steel Door 16 / 20 / 24 ga | 1280 | SF | ||
| B725 | OVERHEAD STEEL DOOR | Optional High Lift (All Doors) | 12 | EA | ||
| B726 | OVERHEAD STEEL DOOR | Optional Vertical Lift (All Doors) | 12 | EA | ||
| B727 | OVERHEAD STEEL DOOR | Manual - Chain Operation (All Doors) | 26 | EA | ||
| B728 | OVERHEAD STEEL DOOR | Electrical Operators for Doors 16 \ 20 \ 24ga | 30 | EA | ||
| B729 | OVERHEAD STEEL DOOR | Additional Control station exterior with locking device (All Doors) | 9 | EA | ||
| B730 | OVERHEAD STEEL DOOR | Vision Panels (All Doors) | 255 | SF | ||
| B731 | Reserved for Future Use | |||||
| B732 | Reserved for Future Use | |||||
| B733 | Overhead Aluminum Door | Basic Overhead Aluminum Door .050ga- Interior Mounted - anodized - Std lift Manual Lift Operation and painted | 3222 | SF | ||
| B734 | Overhead Aluminum Door | Optional High Lift | 15 | EA | ||
| B735 | Overhead Aluminum Door | Optional Vertical Lift | 9 | EA | ||
| B736 | Overhead Aluminum Door | Manual - Chain Operation | 20 | EA | ||
| B737 | Overhead Aluminum Door | Electrical Operator ( | 17 | EA | ||
| B738 | Overhead Aluminum Door | Additional control station exterior with locking device | 11 | EA | ||
| B739 | Overhead Aluminum Door | Vision Panels | 833 | SF | ||
| B740 | Overhead Aluminum Door | Add on for insulated Overhead Aluminum Door per SF. | 2000 | SF | ||
| B741 | Reserved for Future Use | |||||
| B742 | Reserved for Future Use | |||||
| B743 | STANDARD FLUSH STEEL DOOR 1-3/4 | 2'8" x 6'8" | 16 | EA | ||
| B744 | STANDARD FLUSH STEEL DOOR 1-3/4 | 3'0" x 6'8" | 87 | EA | ||
| B745 | STANDARD FLUSH STEEL DOOR 1-3/4 | 4'0" x 6'8" | 8 | EA | ||
| B746 | STANDARD FLUSH STEEL DOOR 1-3/4 | 3'0" x 7'0" | 133 | EA | ||
| B747 | Reserved for Future Use | |||||
| B748 | Reserved for Future Use | |||||
| B749 | NON-STANDARD FLUSH DOORS 1-3/4" | Less than 3'0" x 6'8" | 30 | EA | ||
| B750 | NON-STANDARD FLUSH DOORS 1-3/4" | Greater than 3'0" x 6'8" | 42 | EA | ||
| B751 | NON-STANDARD FLUSH DOORS 1-3/4" | Less than 3'0" x 7'0" | 29 | EA | ||
| B752 | NON-STANDARD FLUSH DOORS 1-3/4" | Greater than 3'0" x 7'0" | 13 | EA | ||
| B753 | NON-STANDARD FLUSH DOORS 1-3/4" | Less than 3'0" x 8'0" | 12 | EA | ||
| B754 | NON-STANDARD FLUSH DOORS 1-3/4" | Greater than 3'0" x 8'0" | 13 | EA | ||
| B755 | Reserved for Future Use | |||||
| B756 | Reserved for Future Use | |||||
| B757 | VISION PANELS IN DOORS | Choice Of Vision Panels 10" x 10" | 125 | EA | ||
| B758 | VISION PANELS IN DOORS | Choice Of Vision Panels 5-5/8" x 20" | 35 | EA | ||
| B759 | VISION PANELS IN DOORS | Various Opening Sizes Per Square Foot | 804 | SF | ||
| B760 | Reserved for Future Use | |||||
| B761 | TRANSOMS & SIDE LITES FOR METAL DOORS WITH METAL FRAMES COMPLETE WITH GLAZING AS FOLLOWS: | with Insulated Metal Panel painted to match | 181 | SF | ||
| B762 | TRANSOMS & SIDE LITES FOR METAL DOORS WITH METAL FRAMES COMPLETE WITH GLAZING AS FOLLOWS: | with 1" Insulated Tempered Glass | 186 | SF | ||
| B763 | Reserved for Future Use | |||||
| B764 | LOUVERS INSTALLED IN METAL DOORS | 18-3/4" x 14" | 9 | EA | ||
| B765 | LOUVERS INSTALLED IN METAL DOORS | 24-3/4" x 14" | 6 | EA | ||
| B766 | LOUVERS INSTALLED IN METAL DOORS | 24" x 24" | 29 | EA | ||
| B767 | LOUVERS INSTALLED IN METAL DOORS | Non Standard louver Size | 110 | SF | ||
| B768 | Reserved for Future Use | |||||
| B769 | BASIC HOLLOW METAL FRAMES | Single Door Opening - Welded Type | 40 | EA | ||
| B770 | BASIC HOLLOW METAL FRAMES | Double Door Opening - Welded Type | 30 | EA | ||
| B771 | BASIC HOLLOW METAL FRAMES | Single Door Opening - Knock Down Type | 89 | EA | ||
| B772 | BASIC HOLLOW METAL FRAMES | Double Door Opening - Knock Down Type | 58 | EA | ||
| B773 | BASIC HOLLOW METAL FRAMES | Add on for Fire Rated Doors and Frame 3/4 / 1-1/2 / 3 hours | 67 | EA | ||
| B774 | Reserved for Future Use | |||||
| B775 | FINISH HARDWARE - HINGES | Brass Hinges Mortise Heavy Wt 4-1/2-4-1/2 | 112 | EA | ||
| B776 | FINISH HARDWARE - HINGES | Stainless Steel Hinges Mortise Heavy Wt 4-1/2-4-1/2 | 573 | EA | ||
| B777 | FINISH HARDWARE - HINGES | Brass Hinges Mortise Heavy Wt 5"- 5" | 16 | EA | ||
| B778 | FINISH HARDWARE - HINGES | Stainless Steel Hinges Mortise Heavy Wt 5"- 5" | 46 | EA | ||
| B779 | FINISH HARDWARE - HINGES | Continuous Hinge - Gear Type (Clear Natural Finish) | 250 | LF | ||
| B780 | FINISH HARDWARE - HINGES | Continuous Hinge - Gear Type (Bronze Anodized Finish) | 210 | LF | ||
| B781 | Reserved for Future Use | |||||
| B782 | LOCKS & LATCHES | F75 Passage or closet latch | 131 | EA | ||
| B783 | LOCKS & LATCHES | F82 Entry Lock | 165 | EA | ||
| B784 | LOCKS & LATCHES | F86 Store Room or closet lock | 30 | EA | ||
| B785 | LOCKS & LATCHES | Dead Bolt Lock (single cylinder) | 44 | EA | ||
| B786 | LOCKS & LATCHES | L1000 Mechanical Push Button System with Lever operation and Options | 45 | EA | ||
| B787 | LOCKS & LATCHES | Electrical Cypher Lock with Electrical strike and options | 21 | EA | ||
| B788 | Reserved for Future Use | |||||
| B789 | EXIT DOOR HARDWARE | Rim Type Panic Hardware (exit Device) | 125 | EA | ||
| B790 | EXIT DOOR HARDWARE | Vertical Rod Panic Hardware (exit Device) | 73 | EA | ||
| B791 | EXIT DOOR HARDWARE | Hardware for labeled Fire Doors and Exit Doors (Add) | 50 | EA | ||
| B792 | Reserved for Future Use | |||||
| B793 | MISCELLANEOUS DOOR HARDWARE | Thresholds | 188 | EA | ||
| B794 | MISCELLANEOUS DOOR HARDWARE | Door Bolts | 87 | EA | ||
| B795 | MISCELLANEOUS DOOR HARDWARE | Surface Door Closures | 350 | EA | ||
| B796 | MISCELLANEOUS DOOR HARDWARE | Door Pulls | 61 | EA | ||
| B797 | MISCELLANEOUS DOOR HARDWARE | Push Plates | 47 | EA | ||
| B798 | MISCELLANEOUS DOOR HARDWARE | Bars | 26 | EA | ||
| B799 | MISCELLANEOUS DOOR HARDWARE | Astragals | 93 | EA | ||
| B800 | MISCELLANEOUS DOOR HARDWARE | Weather Stripping | 4219 | LF | ||
| B801 | MISCELLANEOUS DOOR HARDWARE | Door Coordinator | 64 | EA | ||
| B802 | MISCELLANEOUS DOOR HARDWARE | Kick Plates | 114 | EA | ||
| B803 | MISCELLANEOUS DOOR HARDWARE | Mop Plates | 16 | EA | ||
| B804 | MISCELLANEOUS DOOR HARDWARE | Edge Guards | 17 | EA | ||
| B805 | MISCELLANEOUS DOOR HARDWARE | Door Sweep | 181 | EA | ||
| B806 | MISCELLANEOUS DOOR HARDWARE | Door Sweep | 181 | LF | ||
| B807 | MISCELLANEOUS DOOR HARDWARE | Removable Mullion | 8 | EA | ||
| B808 | MISCELLANEOUS DOOR HARDWARE | Fixed Mullion | 10 | EA | ||
| B809 | Reserved for Future Use | |||||
| B810 | MISCELLANEOUS WORK | Painting Existing Door Frame | 2479 | SF | ||
| B811 | MISCELLANEOUS WORK | Install Up to 3/4" Conduit and 4 wires from power panel to electric operated door location (includes breaker for panel and disconnect switch at door) | 1881 | LF | ||
| B812 | MISCELLANEOUS WORK | Lumber for Mounting Frames (Salt Treated) Includes Installation | 251 | BF | ||
| B813 | Reserved for Future Use | |||||
| B814 | Unit Priced Labor Work - MUST BE NEGOTIATED BY KO. | Provide labor to perform all Unit Priced Labor work subject to the Service Contract Act per the scope and delivery schedule specified in the order. | 1300 | HR | ||
| B815 | Unit Priced Labor Work - MUST BE NEGOTIATED BY KO. | Provide labor to perform all Unit Priced Labor work subject to the Davis Bacon Act per the scope and delivery schedule specified in the order. | 1300 | HR | ||
| B816 | Material Costs- MUST BE NEGOTIATED BY KO. | Provide all materials and equipment to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use with ELIN A702. | 1 | NTE | ||
| B817 | Engineering Studies - MUST BE NEGOTIATED BY KO | The Contractor shall provide an engineering study of an existing condition or proposed situation, e.g., installation traffic, land use, alternative site investigation, and AICUZ, as requested by an internal or external customer. Services shall include research of applicable regulations, site investigation, and preparation of a written report indicating background, findings, and recommendation(s), complete with supporting graphics, e.g., sketches and drawings, and a detailed cost estimate of the recommended maintenance, repair or construction work. Necessary copies of a pre-final report shall be provided to the requestor and any impacted customers for review and comment incorporation prior to distribution of the final copy. All services shall be completed within the time specified in the task order. | 80 | HR | ||
| TOTAL INDEFINITE QUANTITY PRICE BASE YEAR |
Recurring 2nd Opt Period
| ATTACHMENT J-0200000-15 | |||||
| EXHIBIT LINE ITEM NUMBERS | |||||
| SOLICITATION/CONTRACT N40085-19-R-9038 | |||||
| EXHIBIT C | |||||
| Line Item 0005 Recurring Price - Second Opt Period | |||||
| PROVIDE PRICES FOR FACILITY INVESTMENT - RECURRING PRICE - IN ACCORDANCE WITH SECTION C, SPEC ITEM 3 | |||||
| ELINs C001 through C022 | |||||
| ELIN /Sub ELIN | Description | Quantity | Unit of Issue | Unit Price | Total |
| C001 | NNSY CIA Spec Item 3 | ||||
| C001AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| C001AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| C001AC | Routine Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| C001AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 173 | EA | ||
| C001AE | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 6 | EA | ||
| C001AF | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 1 | EA | ||
| C001AG | PM Program, Overhead Metal Doors 1,501-2,000 SF Spec Item 3.2.1 | 1 | EA | ||
| C00AH | PM Program, Overhead Metal Doors 2,001-3,000 SF Spec Item 3.2.1 | 3 | EA | ||
| C001AJ | PM Program, Curtain DoorsSpec Item 3.2.1 | 1 | |||
| C001AK | PM Program, Sliding Doors Spec Item 3.2.2 | 8 | EA | ||
| C001AL | Reserved for Future Use | ||||
| C001AM | Reserved for Future Use | ||||
| C002 | Facility Management 1501000 | ||||
| C002AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NNSY CIA Subtotal | |||||
| C003 | NNSY NON-CIA Spec Item 3 | ||||
| C003AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| C003AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| C003AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| C003AD | PM Program, Overhead Metal Doors 501-1,000 SF Spec Item 3.2.1 | 202 | EA | ||
| C003AE | PM Program, Overhead Metal Doors 1,001-1,500 SF Spec Item 3.2.1 | 1 | EA | ||
| C003AF | PM Program, Canvas Doors Spec Item 3.2.1 | 2 | EA | ||
| C003AG | PM Program, Sliding Doors Spec Item 3.2.2 | 6 | EA | ||
| C003AH | PM Program, Bi-Fold DoorsSpec Item 3.2.3 | 3 | EA | ||
| C003AJ | Reserved for Future Use | ||||
| C003AK | Reserved for Future Use | ||||
| C004 | Facility Management 1501000 | ||||
| C004AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NNSY NON-CIA Subtotal | |||||
| C005 | NUWC Spec Item 3 | ||||
| C005AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| C005AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| C005AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| C005AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 5 | EA | ||
| C005AE | Reserved for Future Use | ||||
| C005AF | Reserved for Future Use | ||||
| C006 | Facility Management 1501000 | ||||
| C006AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NUWC Subtotal | |||||
| C007 | DECA Spec Item 3 | ||||
| C007AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| C007AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| C007AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| C007AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 10 | EA | ||
| C007AE | Reserved for Future Use | ||||
| C007AF | Reserved for Future Use | ||||
| C008 | Facility Management 1501000 | ||||
| C008AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| DECA Subtotal | |||||
| C009 | NSWCCD Spec Item 3 | ||||
| C009AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| C009AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| C009AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| C009AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 2 | EA | ||
| C009AE | Reserved for Future Use | ||||
| C009AF | Reserved for Future Use | ||||
| C010 | Facility Management 1501000 | ||||
| C010AA | Infrastructure Condition Assessment Services (ICAP) | 12 | Month | ||
| NSWCCD Subtotal | |||||
| C011 | SPAWAR Spec Item 3 | ||||
| C011AA | Emergency Service Orders, Spec Item 3.1.1 | 12 | MO | ||
| C011AB | Urgent Service Orders, Spec item 3.1.2 | 12 | MO | ||
| C011AC | Service Service Orders, Spec Item 3.1.3 | 12 | MO | ||
| C011AD | PM Program, Overhead Metal Doors 1-500 SF Spec Item 3.2.1 | 12 | EA | ||
| C011AE | Reserved for Future Use |
This is the start of the file's text. The full file is on GovTribe.