N4008518R8722_Attachment_2_Technical_Info_-_EntryPoint.docx

DOCX document 15 KB Posted

Attached to
Design-Bid-Build (DBB) RM17-1040 Replace NFPC Compound Perimeter Fencing and RM18-0089 Replace NFPC B546 Perimeter Fencing
Solicitation number
N4008518R8722
Issued by

About this file

N4008518R8722_Attachment_2_Technical_Info_-_EntryPoint.docx

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOURCES SOUGHT INFORMATION

Solicitation No.: N4008518R8722 Attachment 2

1. EntryPoint 2-Factor Dual Interface Reader Technical Info. (2 pages Maximum):

The purpose of this amendment is to describe the required security equipment for the NFPC fence projects. Product details can be found in the following attachment:

· Bridgepoint EntryPoint 2-Factor Dual Interface Reader part number 74-01-2003. See attached specification sheet: Bridgepoint EntryPoint 2F Dual Interface Reader-NEW.pdf

The following system characteristics are necessary for compatibility with the existing systems:

· Communicate and operate on an existing Lenel Based system

· Operate on the power and communication parameters noted in specification Section 28 10 05

· Conform to dimensioning as noted on the product cut sheets.

Provide a list of commercially available Dual Interface Readers, manufactured by your organization, meeting the requirements detailed above. Include the following information for each system:

a. Model Number, Catalog Number, Code Number, or equivalent model designation

b. Product Description

c. Manufacturer’s technical data sheets

d. Information necessary to document a minimum 1-year successful field operation performance history for the installed Readers integrated with a Lenel system

1. Experience (3 pages Maximum):

Identify two (2) to three (3) installed systems where you have successfully installed a Dual Interface Reader meeting the above requirements. For each project, provide the customer point of contact including name, phone number, and email, and a narrative description of the product/services provided by your organization. Also provide project title, project location (city/state), procurement contract number, and contract value, if available.

File details come from the government source that posted it.