Condensed1333665__DRAWINGS_20170109.pdf
PDF 24 MB Posted
- Attached to
- CAAA Building 2697 Renovation
- Solicitation number
- N4008518R1621
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment0002.pdf | ||
| 2697_Site_Visit_Roster.pdf | ||
| Amendment0001.pdf | ||
| SB_Subcontracting_Plan.docx | DOCX document | |
| ATTACHMENTS_A,_B.docx | DOCX document | |
| N4008518R1621_Solicitation.pdf | ||
| Additional_Files_Condensed.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL ABBREVIATIONS
HORZ HORIZONTAL
SPA SPACE
SOG SLAB ON GRADE
PROJ PROJECTION
PAF POWER ACTUATED FASTENER
MTL METAL
MEZZ MEZZANINE
MECH MECHANICAL
MANF MANUFACTURER
T/WALL TOP OF WALL
BLDG BUILDING
BOT BOTTOM
B/STL BOTTOM OF STEEL
BRG BEARING
CONT CONTINUOUS
CTRD CENTERED
DWL DOWEL
EXP EXPANSION
FND FOUNDATION
FTG FOOTING
ADDL ADDITIONAL
T/SLAB TOP OF SLAB
ALT ALTERNATE
BM BEAM
BOD BOTTOM OF DECK
BP BASE PLATE
c CAMBER (UPWARD)
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTER LINE
CLR CLEAR COVER
CSJ CONSTRUCTION JOINT
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EL ELEVATION
ELEV ELEVATION
EQUIP EQUIPMENT
EW EACH WAY
FD FLOOR DRAIN
FF FAR FACE
FG FINISH GRADE
FV FIELD VERIFY
GALV GALVANIZED
GC GENERAL CONTRACTOR
GRTG GRATING
DIA DIAMETER
THK THICK
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MIN MINIMUM
NA NOT APPLICABLE
NF NEAR FACE
NTS NOT TO SCALE
OC ON CENTER
OPNG OPENING
PC PIECE
PL PLATE
PSF POUNDS PER SQUARE FOOT
REINF REINFORCEMENT
RTU ROOF TOP UNIT
SEIJ SEALED EDGE ISOLATION JOINT
SEJ SEALED EDGE JOINT
SIM SIMILAR
TP TOP OF PILASTER
T&B TOP AND BOTTOM
TF TOP OF FOOTING
T/STL TOP OF STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/ WITH
WWR WELDED WIRE REINFORCEMENT
AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
CONST CONSTRUCTION
DIM DIMENSION
EQ EQUAL
MAX MAXIMUM
MISC MISCELLANEOUS
REQ'D REQUIRED
WS WATERSTOP
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
PW 7427
1333665
N40083-14-D0016 CR20
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
S
TR
U
C
TU
R A
L G
E N
E R
A L
N O
TE
S
S-001
NOT TO SCALE
BJH MEL RPS
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
PW 7427
1333665
N40083-14-D0016 CR20
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
S
TR
U
C
TU
R A
L S
P E
C
IA
L
IN
S P
E C
TI
O
N S
S-002
BJH MEL RPS
FIRE SUPPRESSION ABBREVIATIONS
FIRE SUPPRESSION SYMBOLSFIRE SUPPRESSION GENERAL NOTES
NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AVG AVERAGE
BFP BACKFLOW PREVENTER
CFM CUBIC FEET PER MINUTE
ELEV ELEVATION
FDC FIRE DEPARTMENT CONNECTION
FHV FIRE HOSE VALVE
FP FIRE PUMP
FPC FIRE PUMP CONTROLLER
FVC FIRE VALVE CABINET
GALS GALLONS
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GV GATE VALVE
JP JOCKEY PUMP
MIN MINIMUM
NP NOT PERMITTED
NC NONCOMBUSTIBLE
OS&Y OUTSIDE SCREW AND YOKE
PSIG POUNDS PER SQUARE INCH GAUGE
SOV SOLENOID VALVE
SQFT SQUARE FEET
TYP TYPICAL
UH UNIT HEATER
VLV VALVE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
THIS SHALL BE A FULLY SPRINKLERED FACILITY DESIGNED IN COMPLIANCE WITH NAVSEA, UFC 3-600-01, NFPA-13, WITH ACCEPTANCE FROM THE NAVFAC FPE. SUBMIT SHOP DRAWINGS TO THE NAVFAC FPE FOR APPROVAL. PRIOR TO THE START OF ANY WORK.
DRAWINGS INDICATE THE DESIGN INTENT. IT IS THE CONTRACTOR'S RESPONSIBILITY UNDER THE SCOPE OF WORK TO COMPLY WITH ALL CODES/STANDARDS SPECIFIED ABOVE TO ACCOMMODATE SPACE CONFIGURATION FOR NEW CONSTRUCTION INCLUSIVE OF, CONTROLS, ACCESSORIES, AND ALL ACCEPTANCE TESTS/APPROVALS FOR A COMPLETE, FULLY COMPLIANT, AND FUNCTIONAL SYSTEM. SUBMIT SHOP DRAWINGS AND HYDRAULIC CALCULATIONS, SPECIFIC PRODUCT DATA, AND DRAWINGS TO INCLUDE, HANGER LOCATIONS, EARTHQUAKE BRACING, SUPPORT STEEL, AND OTHER INSTALLATION DETAILS. SCHEDULE 10 PIPING IS NOT PERMITTED.
REFER TO REFERENCE DOCUMENTS PW7256 IN SPECIFICATION SECTION 21 13 13.0020 FOR DESCRIPTION OF EXISTING CONDITIONS. NOTIFY CONTRACTING OFFICER OF ANY MATERIAL DIFFERENCES IN EXISTING CONDITIONS HAVING A BEARING ON THE PERFORMANCE OF THE
FINISHED WORK BEFORE PERFORMING ANY WORK.
HYDRAULICALLY DESIGN WET PIPE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 / FM GLOBAL AND CONTRACT SPECIFICATION SECTION 21 13 13.0020 REQUIREMENTS. CONDUCT OR ACQUIRE CURRENT WATER FLOW TEST DATA IN ACCORDANCE WITH NFPA 291 AND AS ACCEPTABLE TO THE NAVFAC FPE. PROVIDE HYDRAULIC CALCULATIONS UTILIZING THIS DATA FOR THE SPRINKLER SYSTEM DESIGN. FOR BASIS OF DESIGN, USE THE WATER SUPPLY INFORMATION IN DESIGN DOCUMENTS. NOTIFY THE NAVFAC FPE IF FLOW HAS DEGRADED
SINCE INITIAL BASIS OF DESIGN DATA.
SPRINKLER HEAD LOCATIONS ARE SHOWN FOR COORDINATION. EXACT LOCATIONS AND ARRANGEMENTS OF SPRINKLER HEADS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL DESIGN AND PROVIDE SUPPLEMENTARY STEEL AS REQUIRED FOR THE PROPER SUPPORT OF ALL SPRINKLER PIPING SYSTEMS AND OR FIRE PROTECTION EQUIPMENT. PENETRATIONS AND ANCHORS IN THE
ROOF DECK ARE NOT ACCEPTABLE FOR SUPPORTING FIRE PROTECTION PIPING OR DEVICES.
PROVIDE UPRIGHT SPRINKLERS IN ROOMS WITH NO CEILINGS. UTILIZE UPRIGHT SPRINKLERS WITH WIRE HEAD GUARDS IN AREAS WHERE
SPRINKLERS MAY BE EXPOSED TO MECHANICAL DAMAGE.
PIPING SHALL NOT BE ROUTED IN THE DEDICATED ELECTRICAL SPACE AT OR ABOVE ELECTRICAL SWITCHBOARDS, DISTRIBUTION PANELS, MOTOR CONTROL CENTERS, ETC PER THE NATIONAL ELECTRICAL CODE.
ALL HYDROSTATIC AND ACCEPTANCE TESTING SHALL BE WITNESSED BY THE NAVFAC FPE.
FIRE AND SMOKE STOP ALL PENETRATIONS THROUGH RATED ASSEMBLIES AND SMOKE PARTITIONS. PROVIDE THROUGH-PENETRATION
FIRESTOP SYSTEMS PER UL 1479 AND SPECIFICATION SECTION 07 84 00.
WATER SUPPLY FLOW TEST INFORMATION (PROVIDED FOR REFERENCE ONLY):
ALL PIPING TO BE SCHEDULE 40 BLACK STEEL.
FPE FIRE PROTECTION ENGINEER
NAVFAC NAVAL FACILITIES ENGINEERING COMMAND
NAVSEA NAVAL SEA SYSTEMS COMMAND
s
X
PA
DP
D
AS
FW
FL
CHECK VALVE
FLOW SWITCH
POINT OF CONNECTION
ELECTRIC ALARM BELL
PRESSURE SWITCH
VALVE W/ TAMPER SWITCH
PENDENT ON DROP NIPPLE SPRINKLER HEAD
UPRIGHT ON SPRIG SPRINKLER HEAD
CONCEALED SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
OUTSIDE SCREW AND YOKE VALVE
POST INDICATOR VALVE
PRESSURE INDICATOR
FIRE HYDRANT
FIRE DEPARTMENT CONNECTION
ALARM CHECK
SECTIONAL VALVE
ANGLE VALVE
BUTTERFLY VALVE
DELUGE VALVE
DRY PIPE SYSTEM
PRE-ACTION SYSTEM
HANGER LOCATION
RISER / PIPING DOWN
DOUBLE GATE, DOUBLE CHECK ASSEMBLY
DESCRIPTION
FIRE WATER
AUTOMATIC SPRINKLER
DRAIN LINE
SYMBOL
FIRE LINE
INSPECTOR'S TEST CONNECTION
ORDINARY HAZARD GROUP 1
SPLINKLER SYSTEM AND WATER SUPPLY DESIGN REQUIREMENTS
OCCUPANCY
CLASSIFICATION
SPLINKLER SYSTEM
HOSE STREAM
ALLOWANCE DURATION
OF SUPPLY
MINUTES
COVERAGE AREA PER
SPRINKLER
HEAD
DESIGN DENSITY DESIGN AREA
GPM FT²
GPM/FT² FT²
0.20 ENTIRE AREA 250 60 130
ORDINARY HAZARD GROUP 2OH-2
HAZARD CATEGORY GROUP II
WATER SUPPLY DATA
STATIC
PRESSURE
RESIDUAL
PRESSURE
STATIC/RESIDUAL
HYDRANT
#563
70 PSI 56 PSI
FLOW
HYDRANT
#562
NA 24/26 PSI
FLOW
HYDRANT
#562
NA 1720 GPM
NOTE
HYDRANT FLOW TEST PERFORMED
MARCH 26, 2014 BY HUGHES ASSOCIATES
TEST EFFECTIVE POINT AT HYDRANT 562
REFERENCE C-101 FOR TEST HYDRANT
LOCATIONS
UPRIGHT SPRINKLER WITH WIRE HEAD GUARD
HAZARD CATEGORY 2 (PER FM GLOBAL)HC-2
OH-1
GATE VALVE - CONTROL VALVE
UPRIGHT SPRINKLER
OPEN SPRINKLER HEAD
HAZARD CATEGORY 1 (PER FM GLOBAL)HC-1
FI
R
E P
R O
TE
C
TI
O
N G
E N
E R
A L
N O
TE
S
A N
D A
B B
R E
V
IA
TI
O
N S
FX001
NOT TO SCALE
JF LV MW
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
PEMB PRE-ENGINEERED METAL BUILDING
HC-2
Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
FI
R E
P R
O
TE
C
TI
O N
FL
O
O R
P
LA
N
FX101
1/8" � 1�-0"
JF LV MW
0 8� 16�4�
1/8 " � 1�-0"
24�
FI
R
E P
R O
TE
C
TI
O
N D
E
TA
IL
S
FX501
VARIES
JF LV MW
FLOOR
1" EXTERIOR WALL
SMOOTH BORE 3/4" 45°
ELBOW CORROSION
RESISTANT, PIPE TO
EXTERIOR
FINISHED GRADE OR
PAVEMENT
GLOBE VALVE
FX101
SEALANT
BACKUP MATERIAL
PIPE
ESCUTCHEON AT
EXPOSED LOCATIONS
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
12" MAX
3FT MAX
SUPPORTED FROM STRUCTURE ABOVE.
COORDINATE DESIGN LOAD AND
LOCATIONS WITH PEMB SUPPLIER.
STRUCTURAL CONDITIONS SHOWN ARE NOTIONAL. STRUCTURAL DETAILS TO
BE PROVIDED BY PEMB SUPPLIER. COORDINATE LOADS, POINTS AND MANNER
OF ATTACHMENT WITH PEMB SUPPLIER.
STRUCTURAL CONDITIONS SHOWN ARE NOTIONAL. STRUCTURAL DETAILS TO
BE PROVIDED BY PEMB SUPPLIER. COORDINATE LOADS, POINTS AND MANNER
OF ATTACHMENT WITH PEMB SUPPLIER.
FLASH AND SEAL WALL PLATE
AS REQUIRED
2 1/2" x 2 1/2" x 4" FDC
CHECK VALVE
GALVANIZED PIPING WITH EXTERIOR
WALL PLATE. FLASH AND SEAL WALL
PLATE
INSPECTOR TEST WITH OUTLETS SIZED IN
ACCORDANCE WITH NFPA 13, 7.2.3
PIPE STAND WITH
PIPE SADDLE
FLOOR FLANGE
BOLTED TO FLOOR
BALL DRIP PIPED
TO EXTERIOR
INSPECTOR
TEST CONNECTION
WITH SIGNAGE
SPLASH BOX AS NEEDED FOR
UNPAVED SURFACES
FIRE ALARM SYSTEM GENERAL NOTES
SYMBOLS AND GENERAL NOTES
FIRE ALARM SYMBOLS FIRE ALARM MATRIX
FIRE ALARM DETAILS
FI
R
E A
LA
R
M S
Y M
B O
LS
, A
B B
R E
V
IA
TI
O
N S
, G E
N E
R A
L N
O
TE
S , A
N D
S C
H E
D U
LE
FA001
NOT TO SCALE
JF LV MW
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
FI
R
E A
LA
R
M
FI
R E
A
LA
R M
P
LA
N
FA101
1/8" � 1�-0"
JF LV MW
0 8� 16�4�
1/8 " � 1�-0"
24�
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
CEILING EXHAUST GRILLE/REGISTER
EQUIPMENT ABBREVIATIONS
MECHANICAL ABBREVIATIONS
SYMBOL
DOUBLE LINE
AD
DESCRIPTION
PIPING SYMBOLS
VALVE AND BLIND FLANGE
PIPE HEADER WITH BLIND FLANGE
CHILLED WATER SUPPLYCHWSDESCRIPTION
ACCESS DOOR
DUCTWORK SYMBOLS
SINGLE LINE
AD
L
UC
CAPPED PIPE/OUTLET
PLUGGED PIPE/OUTLET
FLEXIBLE PIPE CONNECTOR
WELD CAP
FE
12"
24x10
FLEXIBLE HOSE (SCREWED ENDS)
FLEXIBLE HOSE (FLANGED ENDS)
STRAINER WITH BLOWDOWN VALVE
EXPANSION JOINT AND ALIGNMENT GUIDES
CONCENTRIC REDUCER
ECCENTRIC REDUCER
UNION
ANCHOR
STRAINER
THERMOMETER
STEAM TRAP
STRAP-ON SENSOR
PRESSURE-TEMPERATURE TEST PLUG
AUTOMATIC AIR VENT
FLOW CONTROL VALVE
PRESSURE GAUGE WITH COCK
FLOW SWITCH
FLOW ELEMENT
FLOW METER
AAV
PLUGGED TEE
TEST COCK
SIGHT GLASS
PLUG VALVE
ET
RG
RL
RS
CR
SS
FOV
GLS
GLR
8" 12x12
18x12
8"
8"
12x12
D
R
T
S
M
S
SPMS
MCD
VD
M
TRIPLE DUTY VALVE
VACUUM RELIEF OR SAFETY VALVE
MOTOR OPERATED CONTROL VALVE
PRESSURE REDUCING VALVE
PRESSURE RELIEF OR SAFETY VALVE
3-WAY CONTROL VALVE
CALIBRATED BALANCING VALVE
ANGLE VALVE
SOLENOID VALVE
BUTTERFLY VALVE
BALL VALVE
ELECTRIC HEAT TRACE
SECTIONAL VALVE (SEE SPECS)
FLUID FLOW DIRECTION
DIRECTION OF PITCH (DOWN)
DOMESTIC COLD WATER
THROTTLING VALVE (SEE SPECS)
REFRIGERANT LIQUID
REFRIGERANT SUCTION
GLOBE VALVE
CHECK VALVE
GATE VALVE
CONDENSATE RETURN
STEAM SUPPLY
FUEL OIL VENT
GLYCOL RETURN
REFRIGERANT GAS
GLYCOL SUPPLY
CWS
CWR
HWS
HWR
CD
FD/SD
FC
SD
FD
CR
V
D
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
HOT WATER SUPPLY
HOT WATER RETURN
CONDENSATE RETURN
CONDENSATE DRAIN PIPE
VENT
DRAIN
MISCELLANEOUS SYMBOLS
PUMP (FOR WATER FLOW DIAGRAM ONLY)
PIPE TURNING DOWN
PIPE BRANCH BOTTOM CONNECTION
PIPE BRANCH TOP CONNECTION
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
REDUCED PRESSURE ZONE
DOOR LOUVER
DOOR UNDERCUT
DUCT TEE WITH SPLITTER DAMPER
SIDEWALL SUPPLY GRILLE/REGISTER
CEILING RETURN GRILLE/REGISTER
SIDEWALL RETURN/EXHAUST
GRILLE/REGISTER
AIR FLOW IN DIRECTION OF ARROW
RECTANGULAR DUCT, SIZE IN INCHES,
FIRST DIMENSION IS SIDE SHOWN
(NET CLEAR INSIDE DIMENSION)
CONICAL LATERAL BRANCH TAKE-OFFS
ROUND DUCT, DIAMETER IN INCHES,
(NET CLEAR INSIDE DIMENSION)
45 BRANCH TAKE-OFFS
CEILING SUPPLY DIFFUSERS
o
L
8"
DUCT SECTION - EXHAUST AIR
DUCT, INCLINED DROP
DUCT, INCLINED RISE
FLEXIBLE DUCT - ROUND
DUCT TRANSITION
DUCT TRANSITION
(SQUARE OR RECTANGULAR
TO ROUND)
DUCT SECTION - RETURN, OUTSIDE,
OR RELIEF AIR
12x12
18x12
STATIC PRESSURE MEASURING STATION
CONTROL DAMPER
FLEXIBLE CONNECTION
VOLUME DAMPER, MANUAL
MOTORIZED DAMPER
DUCT SECTION - SUPPLY AIR
DUCT ELBOW WITH TURNING VANES
COMBINATION FIRE/SMOKE DAMPER
SMOKE DAMPER
FIRE DAMPER
D
R
CD
FD/SD
SD
FD
UC
24x10
12"
12x12
SPMS
M
VD
M
FC
BDD BDD
PIPE TURNING UP
CHILLED WATER RETURNCHWR
MAKE-UP WATERMU
CEILING SUPPLY DIFFUSERS (ROUND)
BACKFLOW PREVENTER
GENERAL NOTES
INSTRUMENT SYMBOLS
(ALL ITEMS SHOWN NOT NECESSARILY USED)
CONTROLS & INSTRUMENTATION TAGS
(ALL ITEMS SHOWN NOT NECESSARILY USED)
AIRFLOW DIAGRAM SYMBOLS
(ALL ITEMS SHOWN NOT NECESSARILY USED)
ELECTRIC
HEATING COIL
MPS MEDIUM PRESSURE STEAM
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
G E
N E
R A
L N
O
TE
S S
Y M
B O
LS
A
N D
A B
B R
E V
IA
TI
O N
S
M-001
BK HO WS
M P S
CR CR CR CR CR
M P S M P S M P S
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
FI
R
S T
FL
O
O R
D E
M O
LI
TI
O N
P
LA
N
MD-101
1/8" = 1'-0"
BK HO WS
0 8' 16'4'
1/8 " = 1'-0"
24'
M P S
T H
T H
T M P S M P S M P S M P S
M P S
CR CR CR CR CR
CR
T
L P S
C R
R S R L
R S R L
M P S M P S M P S
R L
R L
R L
R L
R S
R S
R S
R S
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
FI
R
S T
FL
O
O R
P
LA
N
M-101
1/8" = 1'-0"
BK HO WS
0 8' 16'4'
M P
C
T
L P S
MPS
M P
SM
P S
LPS
L P
SL
P S
L P S
L P S
L P S
CR
C R
C R
R S R S
R L R L
RG
R S
R S
R L
R L
R G
UH
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
E
N
LA
R G
E D
M E
C H
A N
IC
A
L P
LA
N
M-301
1/4" = 1'-0"
BK HO WS
0 4' 8'2'
1/4 " = 1'-0"
12'
M
M
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
S E
C
TI
O N
S
M-401
1/4" = 1'-0"
BK HO WS
1. REFER TO M-0.01 FOR GENERAL NOTES, SYMBOLS, AND
ABBREVIATIONS.
2. CONTRACTOR TO PROVIDE SEVEN (7) DAYS NOTICE PRIOR
TO UTILITY ALL OUTAGES.
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
D E
TA
IL
S
M-501
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
D E
TA
IL
S
M-502
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
D E
TA
IL
S
M-503
ELECTRIC UNIT HEATER SCHEDULE
DX AIR HANDLING UNIT SCHEDULE
MINI SPLIT SYSTEM HEAT PUMP SCHEDULE
STEAM COIL SCHEDULE
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
CONDENSING UNIT SCHEDULE
M E
C H
A N
IC
A
L S
C H
E D
U
LE
S
M-601
NOT TO SCALE
BK HO WS
STEAM-TO-STEAM HUMIDIFIER SCHEDULE
HVAC DESIGN CRITERIA
DIFFUSER REGISTER AND GRILLE SCHEDULE
Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
LOUVER SCHEDULE
M E
C H
A N
IC
A
L S
C H
E D
U
LE
S
M-602
NOT TO SCALE
BK HO WS
FAN SCHEDULE
GRAVITY VENT SCHEDULE
CONDENSATE PUMP SCHEDULE
STEAM TRAP SCHEDULE
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
C O
N
TR
O
LS
M-701
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
C O
N
TR
O
LS
M-702
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
M
E C
H A
N
IC
A L
C O
N
TR
O
LS
M-703
A
Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
P
LU
M
B
IN
G G
E N
E R
A L
N O
TE
S
S Y
M B
O
LS
A N
D A
B B
R E
V
IA
TI
O
N S
P-001
CP CP WS
MEA
LABORATORY
MEA
DOCK
MEA
OVEN ROOM
MEA
LABORATORY
MEA
LABORATORY
MEA
OFFICE
MEA
STORAGE
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
P
LU
M
B
IN
G
FI
R S
T
FL
O O
R D
E M
O
LI
TI
O
N P
LA
N
PD-101
NOT TO SCALE
CP CP WS
0 8' 16'4'
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
P
LU
M
B
IN
G
FI
R S
T
FL
O O
R P
LA
N
P-101
NOT TO SCALE
CP CP WS
PLUMBING FIXTURE SCHEDULE
FLOOR DRAIN/SINK SCHEDULE
WATER HEATER SCHEDULE
WATER SOFTENER SCHEDULE
0 8' 16'4'
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
P
LU
M
B
IN
G D
E
TA
IL
S
P-501
NOT TO SCALE
CP CP WS
F.S.
BRINE TANK
114 112" 212"
SIDE VIEW
8" SHIELD
12" INSERT
8" SHIELD
12" INSERT
8" SHIELD
12" INSERT
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
P
LU
M
B
IN
G D
E
TA
IL
S
P-502
CP CP WS
J
J
E
LE
C
TR
IC
A
L S
Y M
B O
LS
, A
B B
R E
V
IA
TI
O
N S
A N
D G
E N
E R
A L
N O
TE
S
E-001
NOT TO SCALE
SCM SCM LAM
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
E
LE
C
TR
IC
A
L
LI
G H
TI
N
G P
LA
N
E-102
1/8" � 1'-0"
SCM SCM LAM
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
0 8' 16'4'
1/8 " � 1'-0"
LE
C
TR
IC
A
L P
H O
TO
G
R A
P H
S
E-500
NOT TO SCALE
SCM SCM LAM
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
LE
C
TR
IC
A
L P
O W
E R
A N
D L
IG
H
TI
N
G D
E M
O
LI
TI
O
N P
LA
N
ED-101
1/8" � 1'-0"
SCM SCM LAM
S Y
M
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y
A
B
C
D
1 2 3 4 5
1 2 3 4
A
B
C
D
REDUCED PRINT - USE GRAPHIC SCALES
IF SHEET IS LESS THAN 22" X 34"THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
D E
S C
R
IP
TI
O
N D
A
TE
DES DRW REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DES DRW CHK
501 NORTH BROADWAY
ST. LOUIS, MISSOURI 63102
TEL 314-335-4000 FAX 314-335-5012
N A
V
FA
C M
ID
A
TL
A
N
TI
C N
O R
TH
E
A S
T
B U
IL
D
IN
G
R
E N
O V
A
TI
O N
IS
S
U E
F O
R C
O N
S
TR
U C
TI
O
N
JA
N
U A
R Y
0 8' 16'4'
1/8 " � 1'-0"
File details come from the government source that posted it.