This document contains responses to vendor questions regarding solicitation number N4008421T0018 for the procurement of two pumper trucks for USAG-J, Camp Zama. The solicitation seeks quotes for commercial items to supply two pumper trucks per the specifications in Attachment 1. The Navy responded to vendor questions by clarifying specifications around front axle weight distribution, cab construction details, tank filler openings, and turret monitor requirements. The specification for item 55 was revised to require a manual turret monitor rather than a remote type.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Subj: REQUEST FOR QUOTATION NO. N4008421T0018/ PROCUREMENT OF TWO
(2) PUMPER TRUCKS for USAG-J, CAMP ZAMA
Combined Synopsis/Solicitation N4008421T0018 Amendment 0005
Date: 16 August 2021
a. The purpose of this Amendment 0004 is to provide the Government response to Offeror’s inquiry.
36 8/6/2021 11.The persentage of GVW at front axle is not less than 25 percent, nor more than 35 perccent for 4x2.
-->The persentage of GVW at front axle is not less than 25 percent, nor more than 40 perccent for 4x2.
Can you consider accepting front maximum weight distribution from 25% to 40%?
Please see the revised specification, REVISED 5_N4008421T0018_Attachment 1_SPECS Pumper Trucks for Camp Zama.
37 8/6/2021 There was no answer to the following question, so I will ask it again.
39. Cab Construction There are no openings in the ceiling of the inside cab that can be inspected.If you want to check inside the cab ceiling, you will need to remove the inside plastic cover. Please accept it.
This is acceptable
38 8/6/2021
59. TANK FILLER OPENING
This is a follow-up question of Q26. In the answer, it said to suggest a reference photo.
Please find attached a photo of the manhole. Is this acceptable?
This is acceptable
39 8/6/2021 About the ceiling shape of the vehicle.
We understood that the ceiling of the body is open, not covered by an aluminum plate. Please refer to the attached photo. Is this acceptable?
This is acceptable
40 8/11/2021 Item55 TURET MONITOR, the specification was changed to manual type from remote type.
However, we are considering offering remote type as original.
The remote type is that we provided to Torii station the other day. So it has used by Navy before.
Please consider changing specification of Turet monitor to "Remote type or Manual type".
Due to frequent mechanical issues with remote type monitors, manual type is preferred. Remote type is NOT acceptable.
b. The specification for the item# 55 TURRET MONITOR has been revised. Please see the revised specs “REVISED 5_N4008421T0018_Attachment 1_SPECS Pumper Trucks for Camp Zama
c. All other terms and conditions remain the same.