Attachment_E_Table_1_Fuel_Storage_Tanks.docx
DOCX document 29 KB Posted
- Solicitation number
- N4008026R1002
About this file
This is an attachment containing a specialized experience qualification table for fuel storage tanks and spills work relevant to the Multimedia Environmental Compliance Services solicitation. The table lists ten project categories that demonstrate required specialized experience for contractors bidding on this Naval Facilities Engineering Systems Command contract.
The specialized experience categories encompass the full lifecycle of fuel storage tank management and environmental compliance. Required experience includes tank repairs and maintenance on a minimum of 20 fuel storage tanks (both underground and aboveground), tank and oil/water separator cleaning, testing on at least 20 fuel storage tank systems, and compliance inspections on both aboveground and underground storage tanks, including Maryland Triennial Third-Party UST inspections. Additional specialized experience requirements cover tank integrity testing (interior and exterior), ultrasonic thickness testing, microbiologically influenced corrosion sampling and analysis, product compatibility evaluation, and aging tank system compliance assessment. The table also identifies experience requirements for new fuel tank system design and installation (10,000-50,000 gallon capacity), underground storage tank removal and closure procedures, and site investigation work. Environmental remediation experience must include LUST site remediation and closure documentation, POL spill site investigation and remediation, and closure documentation. Finally, contractors must demonstrate experience developing Spill Contingency Plans per OPNAVINST 5090 requirements, SPCC Plans, Facility Response Plans, and Tank Management Plans.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N4008026R1002_PPIs_Amendment0003.pdf | ||
| N4008026R1002_0003.pdf | ||
| Attachment_G_Table_3_Waste_Materials_2.10.26.docx | DOCX document | |
| N4008026R1002_PPIs_Amendment 0002.pdf | ||
| N4008026R1002_0002.pdf | ||
| Attachment_D_Project_Info_Form.docx | DOCX document | |
| Attachment_C_Price_Template.xlsx | XLSX spreadsheet | |
| N4008026R1002 0001.pdf | ||
| N4008026R1002.pdf | ||
| Attachment_A_PIEE_Vendor_Registration_Instructions.pdf | ||
| Attachment_H_PPQ_Form.docx | DOCX document | |
| Attachment_F_Table_2_Air_Quality.docx | DOCX document | |
| Attachment_B_PPI_Log_N4008026R1002.xlsx | XLSX spreadsheet | |
| Attachment_G_Table_3_Waste_Materials.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment E Table 1 Fuel Storage Tanks/Spills
| Specialized Experience |
| Project Number |
| 1 |
| 2 |
| 3 |
| 4 |
| 5 |
| 6 |
| 7 |
| 8 |
| 9 |
| 10 |
Tank repairs/maintenance on at least 20 fuel storage tanks (both UST and AST)
Tank and oil/water separator cleaning
Tank testing on at least 20 fuel storage tank systems
Tank compliance inspections on ASTs
Tanks compliance inspections on USTs
Maryland Triennial Third-Party UST inspections
Tank integrity testing, interior and exterior
Tank ultrasonic thickness testing
MIC sampling and analysis
Tank system product compatibility evaluation
Aging tank system compliance evaluation and recommendation report
New fuel tank system design and installation (10,000 - 50,000 gal)
UST removal
UST in-situ closure
UST site investigation
LUST site remediation and closure documentation
POL spill site investigation, remediation & closure
Spill Contingency Plan Development (OPNAVINST 5090 requirement)
SPCC Plan development
Facility Response Plan development
Tank Management Plan development
File details come from the government source that posted it. Updated .