This document is a detailed foundation design sheet (Sheet S-302) for a Naval Air Station Patuxent River project, specifically the Aircraft Development and Maintenance Facility (Building 646). The sheet provides comprehensive footing schedules with two configurations: one without tension ties and another with tension ties. The footing types range from 5'x5' to 14'x14', with varying depths between 1'6" and 2'6", and include specific reinforcement requirements using different sizes of rebar (from #6 to #10). The design includes detailed technical specifications for spread footings, such as granular fill, compacted subgrade, non-shrink grout specifications, and isolation joint details. The drawing is part of the FY2024 Military Construction (MILCON) Project P691, prepared by NAVFAC and professionally certified by a licensed engineer in Maryland, with the document marked as Controlled Unclassified Information.

View the file

Other files

File Type Posted
N4008025R9500-0041.pdf PDF
N4008025R9500-0038.pdf PDF
N4008025R9500-0037.pdf PDF
N4008025R9500-0036.pdf PDF
N4008025R9500-0034.pdf PDF
N4008025R9500-0030.pdf PDF
N4008025R9500-0029.pdf PDF
N4008025R9500-0028.pdf PDF
N4008025R9500-0026.pdf PDF
N4008025R9500-0025.pdf PDF
N4008025R9500-0023.pdf PDF
N4008025R9500-0022.pdf PDF
N4008025R9500-0021.pdf PDF
N4008025R9500-0020.pdf PDF
AMENDMENT 0017 SF30 CONTINUATION PAGE.pdf PDF
AMENDMENT 0016 SF30 CONTINUATION PAGE.pdf PDF
N4008025R9500-0016.pdf PDF
N4008025R9500-0014.pdf PDF
ATT O Signage Guidelines from IAP.pdf PDF
N4008025R9500-0013.pdf PDF
N4008025R9500-0012.pdf PDF
Revision to SheetAE601.pdf PDF
Revision to Spec 23 05 93.pdf PDF
Revision to Spec 09 65 00.pdf PDF
Revision to Spec 27 41 00.pdf PDF
ATT_C___Construction_and_Design_Experience_Project_Data_Sheet.docx DOCX document
Revision to Spec 32 12 15.13.pdf PDF
N4008025R9500-0009.pdf PDF
ATT A - PIEE Vendor Registration Instructions.pdf PDF
Revision to Spec 32 12 16.16.pdf PDF
ATT_B___PPI_Log.xlsx XLSX spreadsheet
ATT_G___Small_Business_Participation_Commitment_Document.docx DOCX document
Revision to Spec 32 13 14.13.pdf PDF
N4008025R9500-0008.pdf PDF
Revision to Sheet S-101A and S-101D.pdf PDF
Revision to Spec 41 22 13.15.pdf PDF
Revision to Spec 33 40 00.pdf PDF
Revision to Spec 03 30 00.pdf PDF
Revision to Spec 31 62 51.pdf PDF
Revision to Sheet S-111A and S-111C.pdf PDF
N4008025R9500-0007.pdf PDF
P691 Final Geotechnical Report.pdf PDF
N4008025R9500-0006.pdf PDF
ATT H P-691 PRICE PROPOSAL FORM (REV04102025)).docx DOCX document
N4008025R9500-0005.pdf PDF
ATT D Past Performance (REVISED 04022025).doc DOC document
ATT L N4008025JA009_Redacted.pdf PDF
ATT K SECNAV 5512 Access Form.pdf PDF
ATT H P-691 PRICE PROPOSAL FORM.pdf PDF
N4008025R9500 - 0001.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOOTING SCHEDULE WITHOUT TENSION TIES

FOOTING

TYPE

DEPTHLENGTH x WIDTH REINFORCEMENT

2'-6"10'-0" x 10'-0"

2'-0"9'-0" x 9'-0"

2'-0"7'-0" x 7'-0"

2'-0"6'-0" x 6'-0"

F10x10

F9x9

F7x7

F6x6

2'-6"13'-0" x 13'-0"F13x13

2'-0"8'-0" x 8'-0"F8x8

1'-6"5'-0" x 5'-0" (6) #6, E.W., T&BF5x5

(7) #7, E.W., T&B

(8) #7, E.W., T&B

(9) #7, E.W., T&B

(10) #7, E.W., T&B

(11) #8, E.W., T&B

(14) #8, E.W., T&B

2'-6"12'-0" x 12'-0"F12x12 (13) #8, E.W., T&B

2'-6"14'-0" x 14'-0"F14x14 (15) #8, E.W., T&B

NOTES

ONLY AT COLUMNS W/9.5 & W/10

2'-6"8'-0" x 12'-0"F8x12 #8@12", E.W., T&B

R

3 3

/2

/2

4'-0" 2'-0" 2'-0" 4'-0"

12'-0"

U.2

3 3

/2

/2

3'-0" 2'-0" 2'-0" 3'-0"

10'-0"

F10x24 F12x24

4'-0" (MASS CONCRETE)THICKNESS

REINFORCEMENT

FOOTING F18x30

5'-0" (MASS CONCRETE)

K

R

D

3'-0" 4'-0" 4'-0" 3'-0"

14'-0"

R

3'-0" 3'-0" 3'-0" 3'-0"

12'-0"

F10x12 F14x14 F10x13

3'-0" 4'-0" (MASS CONCRETE)

3'-0" 2'-0" 2'-0" 3'-0"

10'-0"

THICKNESS

FOOTING

4'-0" (MASS CONCRETE)

FOOTING SCHEDULE WITH TENSION TIES

3'-0"

D

(11) #8, T&B (LONG DIRECTION)

(25) #8, T&B (SHORT DIRECTION)

(13) #8, T&B (LONG DIRECTION)

(25) #8, T&B (SHORT DIRECTION)

(22) #10, T&B (LONG DIRECTION)

(36) #10, T&B (SHORT DIRECTION)

REINFORCEMENT (15) #8, E.W., T&B

/2

/2

18'-0"

6'-0" 3'-0" 3'-0" 6'-0"

NOTE: ONLY AT COLUMNS D/5, D/7, R/5 & R/7,

NOT AT COLUMNS W/9.5 & W/10

B

3'-2"

DA.2

B

3'-2"

LEGEND HIGH-STRENGTH TENSION ROD AND EMBEDDED

PLATE, SEE DETAIL AND DETAIL/DETAIL C1 S-301 /DETAIL C3 S-301

(11) #8, T&B (LONG DIRECTION)

(13) #8, T&B (SHORT DIRECTION)

(11) #8, T&B (LONG DIRECTION)

(14) #8, T&B (SHORT DIRECTION)

REQ'D CAPACITY PER

TENSION ANCHOR (ASD)

REQ'D CAPACITY PER

TENSION ANCHOR (ASD)

80 K 30 K 30 K

30 K 30 K30 K

2 2 2

SEE SCHEDULE

FLOOR SLAB

C L R

1/2" PJF

COLUMN, SEE PLAN

3" CLR. (TYP.)

SEE SCHEDULE

FOR FOOTING

REINFORCEMENT

SPREAD

FOOTING,

SEE PLAN

SEPARATE POUR

AROUND COLUMN

GRANULAR FILL

COMPACTED

SUBGRADE

1 1/2"± NON-SHRINK GROUT,

UNLESS NOTED OTHERWISE

C L

R

T/ EXIST. SLAB

SEE PLAN

T/ FOOTING

SEE PLAN

FOR ISOLATION JOINT

SEE DETAIL C1/S-502

FOR ISOLATION JOINT

SEE DETAIL C1/S-502

SEE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G T

O N

W A

S H

IN

G

T O

N N

A V

Y Y

A R

D

D .C

AS NOTED

3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092

W A

S H

IN

G

T O

N D

C C

O R

E

N A

V A

L A

IR

S

T A

T

IO

N P

A T

U X

E N

T R

IV

E

R S

T . M

A R

Y 'S

C O

U N

T Y

, M D

F Y

M

IL

C O

N P

1737036

Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 50631 Expiration Date: February 26, 2025

CONTROLLED UNCLASSIFIED INFORMATION

C O

N T

R O

L L E

D U

N C

L A

S S

IF

IE

D I

N F

O R

M A

T

IO

N

CONTROLLED UNCLASSIFIED INFORMATION

C O

N T

R O

L L E

D U

N C

L A

S S

IF

IE

D I

N F

O R

M A

T

IO

N

APPROVED BY ELAINE DORRANS

VIA SAT-TO FORM SIGNATURE

12/13/2024

CHRISTINE RUTKOWSKI, PE

PRODUCTION DIRECTOR

TC

PM/CN

SS

DM

/1

/2

:0

:5

P

M

C U s e rs

\h a n s e lm a n m

\D o c u m e n ts \B

L D

G -P

-1

-S m a rk h a n s e lm a n

.r v t

S-302

F O

U N

D A

TI

O

N D

E

TA

IL

S

WPH

13155940

MWH MWH

A

IR

C R

A F

T D

E V

E

LO

P M

E N

T A

N D

M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

S -3

100% FINAL SUBMITTAL

N.T.SB1

TYPICAL SPREAD FOOTING

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

. C

LA

R

IF

IC

A

T

IO

N

R E

F E

R T

O P

P I #

/1

1/

M

W H

R

E V

. C

LA

R

IF

IC

A

T

IO

N

R E

F E

R T

O P

P I #

/1

1/

M

W H

R

E V

. C

LA

R

IF

IC

A

T

IO

N

R E

F E

R T

O P

P I #

/1

1/

M

W H

Sheets
S-302 - FOUNDATION DETAILS

File details come from the government source that posted it. Updated .