Revision to Sheet S-101A and S-101D.pdf

PDF 422 KB Posted

Attached to
Multiple Award Construction Contract (MACC) - Large Scale Military Projects
Solicitation number
N4008025R9500
Issued by

About this file

The documents are foundation plan drawings (Sheets S-101A and S-101D) for the 646 Aircraft Development and Maintenance Facility at Naval Air Station Patuxent River in St. Mary's County, Maryland. The plans detail structural foundation specifications for Areas A and D, including multiple slab-on-grade configurations with varying thicknesses (5", 6", 8", and 14"), reinforcement requirements, and specialized features like an Ignitable Liquid Drainage Floor Assembly (ILDFA). Key technical details include:

Structural elements include HSS (hollow structural section) columns of different sizes, CMU (concrete masonry unit) walls in 8" and 12" thicknesses, and steel framing members such as W-series and F-series sections. The foundation plans specify precise elevation references, granular base requirements (95% compaction of crushed aggregate), vapor retarders, reinforcement placement, and joint sealing specifications. Specialized areas like hangar door rail drainage, trench drains, and a ramp between elevation levels are also detailed, indicating a complex technical design for a military aviation infrastructure project.

View the file

Other files

File Type Posted
N4008025R9500-0041.pdf PDF
N4008025R9500-0040.pdf PDF
ATT H P-691 PRICE PROPOSAL FORM (REVISED 04202026).pdf PDF
N4008025R9500-0039.pdf PDF
N4008025R9500-0038.pdf PDF
N4008025R9500-0037.pdf PDF
N4008025R9500-0036.pdf PDF
N4008025R9500-0035.pdf PDF
N4008025R9500-0034.pdf PDF
N4008025R9500-0033.pdf PDF
N4008025R9500-0032.pdf PDF
N4008025R9500-0031.pdf PDF
N4008025R9500-0030.pdf PDF
N4008025R9500-0029.pdf PDF
N4008025R9500-0028.pdf PDF
N4008025R9500-0027.pdf PDF
N4008025R9500-0026.pdf PDF
N4008025R9500-0025.pdf PDF
N4008025R9500-0024.pdf PDF
N4008025R9500-0023.pdf PDF
N4008025R9500-0022.pdf PDF
N4008025R9500-0021.pdf PDF
N4008025R9500-0020.pdf PDF
N4008025R9500-0019.pdf PDF
AMENDMENT 0017 SF30 CONTINUATION PAGE.pdf PDF
N4008025R9500-0018.pdf PDF
N4008025R9500-0017.pdf PDF
N4008025R9500-0016.pdf PDF
AMENDMENT 0016 SF30 CONTINUATION PAGE.pdf PDF
ATT H P-691 PRICE PROPOSAL FORM (REV05132025).pdf PDF
N4008025R9500-0015.pdf PDF
ATT H P-691 PRICE PROPOSAL FORM (REV05092025).pdf PDF
N4008025R9500-0014.pdf PDF
ATT O Signage Guidelines from IAP.pdf PDF
N4008025R9500-0013.pdf PDF
N4008025R9500-0011.pdf PDF
N4008025R9500-0012.pdf PDF
Revision to Spec 08 44 00.pdf PDF
Revision to Sheet AE415.pdf PDF
Revision to Spec 23 05 93.pdf PDF
Revision to Spec 27 41 00.pdf PDF
Revision to Spec 09 65 00.pdf PDF
Revision to Sheet AE617.pdf PDF
Revision to SheetAE601.pdf PDF
N4008025R9500-0010.pdf PDF
Revision to Spec 31 05 19.13.pdf PDF
ATT_E___Small_Business_Subcontracting_Plan.docx DOCX document
ATT_D___Past_Performance_Questionnaire.docx DOCX document
Revision to Spec 32 12 15.13.pdf PDF
ATT A - PIEE Vendor Registration Instructions.pdf PDF
Show 40 more

Latest 50 of 85 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A.2 B D E F GCA.4

A

S

-1 B

M A

T C

H L

IN

E

S E

E

HSS8x8x5/8

HSS8x8x5/8

HSS6x6

HSS8x8 HSS6x6

HSS6x6 W14x74 W14x74HSS6x6

W27x146 W27x146 W27x146

6" SLAB-ON-GRADE,

SEE NOTE 5

5" SLAB-ON-GRADE,

SEE NOTE 4

8" SLAB-ON-GRADE,

SEE NOTE 6

MATCHLINE,

SEE /A1 S-101D

6" SLAB-ON-GRADE,

SEE NOTE 5

8 3/8" 5 5/8"

5" SLAB6" SLAB

S L A

B

S L A

B

S L A

B

S L A

B

S L A

B

S L A

B

14" SLAB-ON-GRADE,

SEE NOTE 7

C1

S-304

C1

S-304

C1

S-304

C1

S-304

S L O

P E

22'-2" 23'-10"

1'-2" 2'-0"

31'-0" 26'-10" 39'-4"

ILDFA FLOOR,

SEE NOTE 11

B1

S-305

B1

S-305

10'-10" 11'-4"

S-221

B2

S-221

B3

S-201

A1

S-201

C1

S-222

C1

1'-8" 36'-0" 1'-8"

3'-5" 3'-5"

5'-0"3'-10"

E

.O .S

B1

S-304

B1

S-304

2'-6"

12" CMU WALL

12" CMU WALL

C1

S-305

C1

S-305

C3

S-305

C3

S-305

9.6

F7x7

97'-9"

F6x6

97'-9"

HSS8x8x5/8

HSS8x8

F7x7

97'-9"

HSS8x8

F7x7

97'-9"

HSS8x8

F7x7

97'-9"

HSS6x6

F5x5

97'-9"

HSS6x6

F6x6

97'-9"

HSS6x6

F6x6

97'-9"

HSS6x6

F6x6

97'-9"

SLOPESLOPE

FLOOR DRAIN

HSS6x6x1/2

F6x6

97'-9"

HSS6x6

F6x6

97'-9"

F12x12 F8x12

F8x12

7'-0" 7'-0"

97'-0"

97'-0"

97'-0"

F8x12

97'-0"

97'-9"

F8x8

4'-5" 4'-5"

97'-9"

F10x10

S-351

A2

S-351

A1

(2) PARKING STOPS,

6'-0" LONG EACH, SEE

DETAIL

/DETAIL A2 S-304

S L A

B

S L A

B

6" SLAB8" SLAB

15'-6"

1 1/2" DEPRESSED SLAB

FOR SHOWER PAN, SEE

ARCH. DWGS. FOR SIZE

AND LOCATION

6" SLAB8" SLAB

T/ SLAB

ELEV. = 100'-0"

S-221

A3

97'-0"

F14x14

1. SEE SHEETS S-001, S-002, AND S-003 FOR GENERAL

STRUCTURAL NOTES AND ABBREVIATION KEY.

2. REFERENCE FLOOR ELEVATION OF 100'-0" CORRESPONDS

TO USGS ELEVATION OF 47.0' SEE CIVIL DRAWINGS.

3. ALL SLAB-ON-GRADE FLOOR SLABS MUST HAVE 15 mil

VAPOR RETARDER PLACED BETWEEN THE SLAB AND

GRANULAR BASE.

4. FLOOR SLAB: 5" SLAB-ON-GRADE, REINFORCED WITH

6x6-W2.9xW2.9 WWR, PLACED 2" FROM TOP OF SLAB.

6" GRANULAR BASE. FILL CONTROL AND CONSTRUCTION

JOINTS WITH URETHANE SEALANT.

5. FLOOR SLAB: 6" SLAB-ON-GRADE, REINFORCED WITH

6x6-W2.9xW2.9 WWR, PLACED 2" FROM TOP OF SLAB.

6" GRANULAR BASE. FILL CONTROL AND CONSTRUCTION

JOINTS WITH SEMI-RIGID SEALANT.

6. FLOOR SLAB: 8" SLAB-ON-GRADE, REINFORCED WITH

#4@12" O.C., BOTH WAYS, POSITIONED AT MID-DEPTH OF

SLAB. 6" GRANULAR BASE. FILL CONTROL AND

CONSTRUCTION JOINTS WITH SEMI-RIGID SEALANT.

7. HANGAR FLOOR SLAB: 14" SLAB-ON-GRADE, REINFORCED

WITH #5@12" O.C., BOTH WAYS, POSITION 5 1/2" CLEAR

FROM TOP OF SLAB. 6" GRANULAR BASE. FILL CONTROL

AND CONSTRUCTION JOINTS WITH URETHANE SEALANT.

8. GRANULAR BASE MUST BE FREE-DRAINING CRUSHED

AGGREGATE COMPACTED TO 95% (MINIMUM) OF ASTM

D1557.

9. MASONRY WALLS: 8" (NOMINAL) CMU, #5@24" O.C.

VERTICAL REINFORCEMENT. SEE SHEET S-503.

10. MASONRY WALLS: 12" (NOMINAL) CMU, #6@24" O.C.

VERTICAL REINFORCEMENT. SEE SHEET S-504.

11. IGNITABLE LIQUID DRAINAGE FLOOR ASSEMBLY (ILDFA)

MUST BE EMBEDDED INTO FLOOR SLAB, ILDFA FLOOR

MUST BE RECESSED INTO CONCRETE HANGAR FLOOR

SLAB APPROXIMATELY 2" SUCH THAT THE TOP OF

ADJACENT SLAB IS FLUSH WITH THE ILDFA FLOOR. SEE

NOTE M ON SHEET S-003.

LEGEND

FLOOR SLOPESLOPE

SLAB-ON-GRADE, SEE PLAN NOTES 4 THROUGH 7

8" CMU WALL

EDGE OF SLABE.O.S.

HSS6x6x3/8 COLUMNHSS6x6

HSS8x8x3/8 COLUMNHSS8x8

ILDFA FLOOR TRENCH SYSTEM, SEE NOTE 11

TRENCH DRAWING NOTES:

L.P. LOW POINT ELEVATION = 97'-3"

H.P. HIGH POINT ELEVATION = 97'-10"

HSS5x5x1/2 COLUMNHSS5x5

12" CMU WALL

FOOTING, SEE SCHEDULE ON SHEET S-302F#x#

TOP OF FOOTING ELEVATION#'-#"

AIRCRAFT JACKING POINT

AIRCRAFT GROUNDING POINT, SEE ELEC. DWGS.

T R

U E

N

PLAN

NORTHA B C

D E F G

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G T

O N

W A

S H

IN

G

T O

N N

A V

Y Y

A R

D

D .C

AS NOTED

3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

W A

S H

IN

G

T O

N D

C C

O R

E

N A

V A

L A

IR

S

T A

T

IO

N P

A T

U X

E N

T R

IV

E

R S

T . M

A R

Y 'S

C O

U N

T Y

, M D

F Y

M

IL

C O

N P

1737036

Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 50631 Expiration Date: February 26, 2025

CONTROLLED UNCLASSIFIED INFORMATION

C O

N T

R O

L L E

D U

N C

L A

S S

IF

IE

D I

N F

O R

M A

T

IO

N

CONTROLLED UNCLASSIFIED INFORMATION

C O

N T

R O

L L E

D U

N C

L A

S S

IF

IE

D I

N F

O R

M A

T

IO

N

APPROVED BY ELAINE DORRANS

VIA SAT-TO FORM SIGNATURE

12/13/2024

CHRISTINE RUTKOWSKI, PE

PRODUCTION DIRECTOR

TC

PM/CN

SS

DM

/1

/2

:5

:3

A

M

C U s e rs

\h a n s e lm a n m

\D o c u m e n ts \B

L D

G -P

-1

-S m a rk h a n s e lm a n

.r v t

S-101A

F O

U N

D A

TI

O

N P

LA

N

A

R E

A A

WPH

13155889

MWH SP

A

IR

C R

A F

T D

E V

E

LO

P M

E N

T A

N D

M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

S -1

A

100% FINAL SUBMITTAL

SCALE:

4' 8' 16'0

1/8" = 1'-0"

SCALE: 1/8" = 1'-0"A1

FOUNDATION PLAN - AREA A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

. C

LA

R

IF

IC

A

T

IO

N

R E

F E

R T

O P

P I #

/1

1/

M

W H

1. SEE SHEETS S-001, S-002, AND S-003 FOR GENERAL

STRUCTURAL NOTES AND ABBREVIATION KEY.

2. REFERENCE FLOOR ELEVATION OF 100'-0" CORRESPONDS

TO USGS ELEVATION OF 47.0' SEE CIVIL DRAWINGS.

3. ALL SLAB-ON-GRADE FLOOR SLABS MUST HAVE 15 mil

VAPOR RETARDER PLACED BETWEEN THE SLAB AND

GRANULAR BASE.

4. FLOOR SLAB: 5" SLAB-ON-GRADE, REINFORCED WITH

6x6-W2.9xW2.9 WWR, PLACED 2" FROM TOP OF SLAB.

6" GRANULAR BASE. FILL CONTROL AND CONSTRUCTION

JOINTS WITH URETHANE SEALANT.

5. FLOOR SLAB: 6" SLAB-ON-GRADE, REINFORCED WITH

6x6-W2.9xW2.9 WWR, PLACED 2" FROM TOP OF SLAB.

6" GRANULAR BASE. FILL CONTROL AND CONSTRUCTION

JOINTS WITH SEMI-RIGID SEALANT.

6. FLOOR SLAB: 8" SLAB-ON-GRADE, REINFORCED WITH

#4@12" O.C., BOTH WAYS, POSITIONED AT MID-DEPTH OF

SLAB. 6" GRANULAR BASE. FILL CONTROL AND

CONSTRUCTION JOINTS WITH SEMI-RIGID SEALANT.

7. HANGAR FLOOR SLAB: 14" SLAB-ON-GRADE, REINFORCED

WITH #5@12" O.C., BOTH WAYS, POSITION 5 1/2" CLEAR

FROM TOP OF SLAB. 6" GRANULAR BASE. FILL CONTROL

AND CONSTRUCTION JOINTS WITH URETHANE SEALANT.

8. GRANULAR BASE MUST BE FREE-DRAINING CRUSHED

AGGREGATE COMPACTED TO 95% (MINIMUM) OF ASTM

D1557.

9. MASONRY WALLS: 8" (NOMINAL) CMU, #5@24" O.C.

VERTICAL REINFORCEMENT. SEE SHEET S-503.

10. MASONRY WALLS: 12" (NOMINAL) CMU, #6@24" O.C.

VERTICAL REINFORCEMENT. SEE SHEET S-504.

11. IGNITABLE LIQUID DRAINAGE FLOOR ASSEMBLY (ILDFA)

MUST BE EMBEDDED INTO FLOOR SLAB, ILDFA FLOOR

MUST BE RECESSED INTO CONCRETE HANGAR FLOOR

SLAB APPROXIMATELY 2" SUCH THAT THE TOP OF

ADJACENT SLAB IS FLUSH WITH THE ILDFA FLOOR. SEE

NOTE M ON SHEET S-003.

LEGEND

FLOOR SLOPESLOPE

SLAB-ON-GRADE, SEE PLAN NOTES 4 THROUGH 7

8" CMU WALL

EDGE OF SLABE.O.S.

HSS6x6x3/8 COLUMNHSS6x6

HSS8x8x3/8 COLUMNHSS8x8

ILDFA FLOOR TRENCH SYSTEM, SEE NOTE 11

TRENCH DRAWING NOTES:

L.P. LOW POINT ELEVATION = 97'-3"

H.P. HIGH POINT ELEVATION = 97'-10"

HSS5x5x1/2 COLUMNHSS5x5

12" CMU WALL

FOOTING, SEE SCHEDULE ON SHEET S-302F#x#

TOP OF FOOTING ELEVATION#'-#"

AIRCRAFT JACKING POINT

AIRCRAFT GROUNDING POINT, SEE ELEC. DWGS.

A A.2 B D E F G

CA.4

M A

T C

H L

IN

E

S E

E

A

S -1

E

W27x146

HSS8x8

W27x146

HSS8x8

W27x146

HSS8x8

W27x146HSS8x8

W14x132

W14x132W14x90

W14x90

HSS6x6 HSS6x6

8" SLAB-ON-GRADE,

SEE NOTE 6 14" SLAB-ON-GRADE,

SEE NOTE 7

MATCHLINE,

SEE /A1 S-101A

C1

S-304

B4

S-304

10'-10" 35'-2"

3'-2"

31'-0" 26'-10" 39'-4"

S L O

P E

9'-5"9'-5"9'-5"9'-5"9'-5"9'-5"9'-5"9'-5"9'-5"9'-5"6'-0 1/2"

HANGAR DOOR

RAIL DRAINAGE,

SEE DETAIL /DETAIL C1 S-308

C1

S-306

C1

S-306

SIM.

39'-0" 37'-8"

TRENCH DRAIN

RAIL DRAIN

DIMENSIONS

EDGE OF

RAIL POCKET

T/ SLAB

ELEV. = 99'-4"

EDGE OF

RAIL POCKET

ILDFA FLOOR,

SEE NOTE 11

B1

S-305

S-221

C1

S-221

C2

S-209

A1

S-209

C1

S-208

A3

S-208

C3

S-221

C3

S-205

C1

S-205

A2

38'-2" 38'-2"

TRENCH

DRAIN L.P.

TRENCH

DRAIN H.P. 38'-2"

TO DRAIN L.P.

/2

/2

/2

/2

C1

S-307 -E

.O .S

/8

E.O.S.

1'-10 5/8"

E.O.S.

1'-6 5/8"

6'-4 3/4"

B1

S-304

2'-6"

8" CMU

WALL

12" CMU WALL

8" CMU WALL

8" CMU

WALL

C1

S-305

C3

S-305

HSS8x8

F7x7

97'-9"

HSS8x8

F7x7

97'-9"

HSS8x8

F7x7

97'-9"

HSS8x8

F7x7

97'-9"

HSS6x6

F7x7

97'-9"

7'-0" 7'-0" 97'-0"

F14x14

6'-0" 6'-0"

95'-6"

F10x12

8'-0" 6'-0"

97'-0"

F14x14

TRENCH

DRAIN H.P.

97'-0"

F10x24 97'-0"

F12x24

S-223

C3

S-205

A3

C1

S-304

RAMP FROM ELEV. 100'-0" TO

MATCH HANGAR FLOOR

SLAB, SEE DETAIL /DETAIL B1 S-402

B3

S-305

B3

S-305

ILDFA TRENCH

ILDFA TRENCH

A1

S-305

A3

S-305

TYP.

S L A

B

5" S.O.G., T/ SLAB

ELEV. = 99'-4"

S L A

B

97'-0"

F14x14

T R

U E

N

PLAN

NORTHA B C

D E F G

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G T

O N

W A

S H

IN

G

T O

N N

A V

Y Y

A R

D

D .C

AS NOTED

3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

W A

S H

IN

G

T O

N D

C C

O R

E

N A

V A

L A

IR

S

T A

T

IO

N P

A T

U X

E N

T R

IV

E

R S

T . M

A R

Y 'S

C O

U N

T Y

, M D

F Y

M

IL

C O

N P

1737036

Professional Certification. I hereby certify that these documents were prepared or approved by me, and that I am a duly licensed professional engineer under the laws of the State of Maryland, License No. 50631 Expiration Date: February 26, 2025

CONTROLLED UNCLASSIFIED INFORMATION

C O

N T

R O

L L E

D U

N C

L A

S S

IF

IE

D I

N F

O R

M A

T

IO

N

CONTROLLED UNCLASSIFIED INFORMATION

C O

N T

R O

L L E

D U

N C

L A

S S

IF

IE

D I

N F

O R

M A

T

IO

N

APPROVED BY ELAINE DORRANS

VIA SAT-TO FORM SIGNATURE

12/13/2024

CHRISTINE RUTKOWSKI, PE

PRODUCTION DIRECTOR

TC

PM/CN

SS

DM

/1

/2

:5

:3

A

M

C U s e rs

\h a n s e lm a n m

\D o c u m e n ts \B

L D

G -P

-1

-S m a rk h a n s e lm a n

.r v t

S-101D

F O

U N

D A

TI

O

N P

LA

N

A

R E

A D

WPH

13155892

MWH SP

A

IR

C R

A F

T D

E V

E

LO

P M

E N

T A

N D

M A

IN

T

E N

A N

C E

F A

C

IL

IT

Y

S -1

D

100% FINAL SUBMITTAL

SCALE:

4' 8' 16'0

1/8" = 1'-0"

SCALE: 1/8" = 1'-0"A1

FOUNDATION PLAN - AREA D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

. C

LA

R

IF

IC

A

T

IO

N

R E

F E

R T

O P

P I #

/1

1/

M

W H

Sheets
S-101A - FOUNDATION PLAN - AREA A
S-101D - FOUNDATION PLAN - AREA D

File details come from the government source that posted it. Updated .