Chain of Custody: 282355
Client: IEI, Inc.
Address: 9220 Rumsey Road Columbia, MD 21045
Attention: Kosala DeSilva
Job Name: NAVFAC
Job Location: Stump Neck B-235N
Job Number: 15-0011
P.O. Number: Not Provided
Date Submitted: 07/27/2017
Date Analyzed: 07/28/2017
Report Date: 07/28/2017
Date Sampled: 07/26/2017
Person Submitting: Jim Sagerholm
CERTIFICATE OF ANALYSIS
Summary of Atomic Absorption Analysis for Lead
AMA Sample Number Client Sample Number Analysis Type Sample Type Reporting Limit Final Result Comments
282355-1 1-7-26-17 Flame AA Paint Chip 0.0079 %Pb 0.015 %Pb
282355-2 2-7-26-17 Flame AA Paint Chip 0.0085 %Pb 0.037 %Pb
282355-3 3-7-26-17 Flame AA Paint Chip 0.0063 %Pb 5 %Pb
282355-4 4-7-26-17 Flame AA Paint Chip 0.0068 %Pb 0.044 %Pb
282355-5 5-7-26-17 Flame AA Paint Chip 0.008 %Pb 0.27 %Pb
Analysis Method for Flame: Air, Wipes, Paints, and Soil/Solids: EPA 600/R-93/200(M)-7000B; Water: SM-3111B Analysis Method For Furnace: Air, Wipes, Paints, and Soil/Solids : EPA 600/R-93/200(M)-7010; Water: SM-3113B N/A = Not Applicable mg/Kg = parts per million (ppm) on a dry weight basis mg/L = parts per million (ppm) %Pb = percent lead on a dry weight basis ug = micrograms ug/L = parts per billion (ppb) Note: All samples were received in good condition unless otherwise noted.
Note: All results have two significant digits. Any additional digits shown should not be considered when interpreting the result.
Analyst(s): George Land
See QC Summary for analytical results of quality control samples associated with these samples.
Air and Wipe results are not corrected for any blank results. Final results for air and wipe samples are based on client supplied information not verified by this laboratory.
All results are to be considered preliminary and subject to change unless signed by the Technical Director or Deputy.
Technical Director G. Edward Carney
This report applies only to the sample, or samples, investigated and is not necessarily indicative of the quality or condition of apparently identical or similar products. As a mutual protection to clients, the public, and these Laboratories, this report is submitted and accepted for the exclusive use of the client to whom it is addressed and upon the condition that it is not to be used, in whole or in part, in any advertising or publicity matter without prior written authorization from us. Sample types, locations, and collection protocols are based upon the information provided by the persons submitting them and, unless collected by personnel of these Laboratories, we expressly disclaim any knowledge and liability for the accuracy and completeness of this information. Residual sample material will be discarded in accordance with the appropriate regulatory guidelines, unless otherwise requested by the client. This report must not be used to claim, and does not imply product certification, approval, or endorsement by NY ELAP, AIHA, or any agency of the Federal Government. All rights reserved. AMA Analytical Services, Inc.
4475 Forbes Blvd. · Lanham, MD, 20706 · (301) 459-2640 · Toll Free (800) 346-0961 · Fax (301) 459-2643 1/1
QC Summary for SDG #51923
Overview
Analysis Type: Flame AA Sample Type: Paint Chip Analysis Date: 07/28/2017
Samples Included
282355-1 282355-2 282355-3 282355-4 282355-5
Preparation Blank
Result: -0.028 ppm
Report Limit Vertification Sample
Percent Recovery: 92.0%
Duplicates
RPD: 5.6%
Matrix Spike Analysis
Spiked Sample Percent Recovery: 98.5% Spike Duplicate Percent Recovery: 88.5%
RPD: 10.7%
Matrix Blank
Result: N/A
Laboratory Control Sample #1
Percent Recovery: 107.4%
Laboratory Control Sample #2
Percent Recovery: 116.65%
Reference Sample
Percent Recovery: N/A
Calibration Curve
Correlation: 0.999668
Serial Dilution / Bench Spike
Serial Dilution RPD: N/A Bench Spike Percent Recovery: N/A
Notes
4475 Forbes Blvd. · Lanham, MD, 20706 · (301) 459-2640 · Toll Free (800) 346-0961 · Fax (301) 459-2643 1/1
| CERTIFICATE OF ANALYSIS |
| Summary of Atomic Absorption Analysis for Lead |
QC Summary for SDG #51923