This is a Technical Contract and Statement of Work for the fabrication of twelve 3 cubic foot capacity demineralizer units for Portsmouth Naval Shipyard in Kittery, Maine. The contractor must provide all materials, engineering, labor, fabrication, nondestructive testing (NDT), hydrostatic testing, and technical documentation required to manufacture and deliver the units in strict accordance with Puget Sound Naval Shipyard & IMF Drawing No. M-1217, Revision A. The Defense Contract Management Agency (DCMA) and Navy Special Emphasis Operations (NSEO) serve as the Administrative Authority and Inspecting Agency, with Osvaldino Tavares as the Technical Point of Contact at Portsmouth Naval Shipyard.
All fabrication, testing, and materials must conform to the latest revisions of specified standards and codes, including ASME Boiler & Pressure Vessel Code Section VIII, Division 1 with required "U" code stamping, ANSI N14.6-1993 lifting standards for safe handling design, AWS D1.1 welding standards, NAVSEA TP T9074-AS-GIB-010/271, and MIL-STD-2035 for Class 1 & 3 nondestructive testing. Material specifications require ASTM A240 (304 Stainless Steel), ASTM A312, ASTM A182, and Monel QQ-N-281. All work must be performed in accordance with the specifications, general notes, material lists, and geometric dimensions detailed in the referenced drawing.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Contract & Statement of Work Project: Fabrication of QTY (12) 3 ft^3 Demineralizer
Drawing Reference: Puget Sound Naval Shipyard & IMF, Drawing No. M-1217, Revision A
Procuring Agency: Portsmouth Naval Shipyard, Kittery, ME 03904
Technical Point of Contact (POC): Osvaldino Tavares, Phone: (207) 438-5378
Administrative Authority / Inspecting Agency: Defense Contract Management Agency (DCMA) / Navy Special Emphasis Operations (NSEO)
Destination / Shipping Address: Portsmouth Naval Shipyard, Kittery, ME 03904 (Attn: Osvaldino Tavares, Phone: (207) 438-5378)
1. Scope of Work The contractor shall provide all materials, engineering, labor, fabrication, non-destructive testing (NDT), hydrostatic testing, and technical documentation required to manufacture and deliver QTY (12) 3 cubic foot capacity demineralizer.
All work must be performed in strict accordance with the specifications, general notes, material lists, and geometric dimensions detailed in Drawing No. M-1217.
2. Applicable Standards & Codes All fabrication, testing, and materials must conform to the latest revisions of the following standards as cited on the drawing:
• ASME Boiler & Pressure Vessel Code (BPVC): Section VIII, Division 1 (Vessel must be code-stamped with the "U" symbol).
• Lifting Standard: ANSI N14.6-1993 (Special lifting devices for shipping containers weighing 10,000 lbs or more, applied here for safe handling design).
• Welding & NDT Standards: AWS D1.1 (Structural), NAVSEA TP T9074-AS-GIB- 010/271, and MIL-STD-2035 (Class 1 & 3).
• Material Specs: ASTM A240 (304 Stainless Steel), ASTM A312, ASTM A182, and Monel QQ-N-281.
| Technical Contract & Statement of Work |
| 1. Scope of Work |
| 2. Applicable Standards & Codes |
| Contract Data Requirements List (CDRL) |
| Master CDRL Summary Matrix (Landscape Layout) |
| 3. Individual DD Form 1423 Data Sheets |
| CDRL A001: ASME BPVC Manufacturer's Data Report |
| CDRL A002: Actual Demineralizer Weight Report |
| CDRL A003: Hydrostatic Test Certificate |
| CDRL A004: Lifting Lug Load Test Report |
| CDRL A005: Lifting Lug Visual Inspection (VT) Report |
| CDRL A006: Lifting Lug Liquid Penetrant (PT) Report |
| CDRL A007: Radiographic Inspection (RT) Package |
| CDRL A008: Paint Formulas & Safety Data Sheets (SDS) |
| CDRL A009: Material Test Certification Reports |
| CDRL A010: Certified Lug Testing Report |
| CDRL A011: Lifting Lug Design & Safety Calculations |
| CDRL A012: Manufacturer's Shop Drawings |
File details come from the government source that posted it. Updated .