N39040Q6189V257_Attachment 1_TC_3 CU FT DEMINERALIZERS.pdf
PDF 142 KB Posted
- Solicitation number
- N39040Q6189V257
About this file
This is a Technical Contract & Statement of Work for the fabrication of twelve 3 cubic foot capacity demineralizers for Portsmouth Naval Shipyard in Kittery, Maine. The contractor must provide all materials, engineering, labor, fabrication, nondestructive testing (NDT), hydrostatic testing, and technical documentation required to manufacture and deliver the units in strict accordance with Puget Sound Naval Shipyard & IMF Drawing No. M-1217, Revision A.
All fabrication, testing, and materials must conform to the latest revisions of applicable standards including ASME Boiler & Pressure Vessel Code (BPVC) Section VIII, Division 1 with required "U" symbol code stamping; ANSI N14.6-1993 for lifting device design; AWS D1.1 for structural welding; NAVSEA TP T9074-AS-GIB-010/271 and MIL-STD-2035 (Class 1 & 3) for welding and NDT standards; and material specifications including ASTM A240 (304 Stainless Steel), ASTM A312, ASTM A182, and Monel QQ-N-281. The Defense Contract Management Agency (DCMA) and Navy Special Emphasis Operations (NSEO) serve as the administrative authority and inspecting agency. The technical point of contact is Osvaldino Tavares at Portsmouth Naval Shipyard, (207) 438-5378, who also serves as the shipping destination contact.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Contract & Statement of Work Project: Fabrication of QTY (12) 3 ft^3 Demineralizer
Drawing Reference: Puget Sound Naval Shipyard & IMF, Drawing No. M-1217, Revision A
Procuring Agency: Portsmouth Naval Shipyard, Kittery, ME 03904
Technical Point of Contact (POC): Osvaldino Tavares, Phone: (207) 438-5378
Administrative Authority / Inspecting Agency: Defense Contract Management Agency (DCMA) / Navy Special Emphasis Operations (NSEO)
Destination / Shipping Address: Portsmouth Naval Shipyard, Kittery, ME 03904 (Attn: Osvaldino Tavares, Phone: (207) 438-5378)
1. Scope of Work The contractor shall provide all materials, engineering, labor, fabrication, non-destructive testing (NDT), hydrostatic testing, and technical documentation required to manufacture and deliver QTY (12) 3 cubic foot capacity demineralizer.
All work must be performed in strict accordance with the specifications, general notes, material lists, and geometric dimensions detailed in Drawing No. M-1217.
2. Applicable Standards & Codes All fabrication, testing, and materials must conform to the latest revisions of the following standards as cited on the drawing:
• ASME Boiler & Pressure Vessel Code (BPVC): Section VIII, Division 1 (Vessel must be code-stamped with the "U" symbol).
• Lifting Standard: ANSI N14.6-1993 (Special lifting devices for shipping containers weighing 10,000 lbs or more, applied here for safe handling design).
• Welding & NDT Standards: AWS D1.1 (Structural), NAVSEA TP T9074-AS-GIB- 010/271, and MIL-STD-2035 (Class 1 & 3).
• Material Specs: ASTM A240 (304 Stainless Steel), ASTM A312, ASTM A182, and Monel QQ-N-281.
| Technical Contract & Statement of Work |
| 1. Scope of Work |
| 2. Applicable Standards & Codes |
| Contract Data Requirements List (CDRL) |
| Master CDRL Summary Matrix (Landscape Layout) |
| 3. Individual DD Form 1423 Data Sheets |
| CDRL A001: ASME BPVC Manufacturer's Data Report |
| CDRL A002: Actual Demineralizer Weight Report |
| CDRL A003: Hydrostatic Test Certificate |
| CDRL A004: Lifting Lug Load Test Report |
| CDRL A005: Lifting Lug Visual Inspection (VT) Report |
| CDRL A006: Lifting Lug Liquid Penetrant (PT) Report |
| CDRL A007: Radiographic Inspection (RT) Package |
| CDRL A008: Paint Formulas & Safety Data Sheets (SDS) |
| CDRL A009: Material Test Certification Reports |
| CDRL A010: Certified Lug Testing Report |
| CDRL A011: Lifting Lug Design & Safety Calculations |
| CDRL A012: Manufacturer's Shop Drawings |
File details come from the government source that posted it. Updated .