This is a product specification and technical data sheet for AAC American Aerospace Controls Inc.'s Series 205 DC Ammeter Shunt. The document details a line of DC ammeter shunts designed to measure electrical current in high-amperage applications, with measuring ranges from 2,500A to 10,000A and output ranges of 50mV and 100mV. The shunts are composed of manganin strip material paired with either brass (for ratings below 10,000A) or copper (for 10,000A and higher ratings), featuring constant current distribution to shunt strips and standard accuracy of ±0.25% (with 0.1% accuracy available upon request).

The specification includes detailed dimensional tables for 20 different catalog number configurations across two output ranges. Key technical recommendations address mounting requirements, operational limits (shunts should run no more than two-thirds rated current under normal conditions), temperature constraints (manganin strip must not exceed 145°C), and installation guidance regarding lead length considerations, parallel connection capabilities, and proper vertical orientation for air convection. Terminal blocks are slotted to receive one-quarter inch bars, and dimensional tolerances are specified at ±0.015 inches for hole diameters and ±0.030 inches for other measurements. The document includes a technical drawing with component layout, dimensional diagrams, and a detailed illustration of the shunt assembly showing the stacked copper blade construction with terminal blocks.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drawing: 700-205 Cage Code Ident. No. 15948 AAC American Aerospace Controls Inc., 570 Smith St, Farmingdale, NY 11735 Tel: (631) 694-5100 website: www.a-a-c.com

AAC 205 SERIES

Rev.

A

DC AMMETER SHUNT

SERIES 205

RECOMMENDATIONS

- Shunts should be mounted on the grounded side of the circuit (or mounted on the grounded side of circuits above 750 volts for panel mounted shunts with insulated bases.)

- Shunts should run for no more than two-thirds (2 3⁄ ) the rated current under normal conditions as per AIEEE standards.

- The manganin shunt strip must not exceed 145°C, as this will cause permanent change in resistance.

- If longer lead lengths are necessary, the additional IR (millivolt) drop in the leads must be taken into consideration when ordering instruments.

- Shunts may be connected (without error) in parallel to measure heavy currents providing each shunt has a separate pair or millivolt leads connected to the instrument terminals.

- The resistance blades of the shunt should be mounted in a vertical position with the longitudinal axis of the shunt in a horizontal position in order to promote the free convectional flow of air.

FEATURES

- Measuring range: 2500A to 10,000A

- Output range: 50mV and 100mV

- Composed of manganin and either brass (for shunts rated below 10,000A) or copper (for shunts rated 10,000A and higher)

- Constant current distribution to shunt strips

- Terminal blocks are slotted to receive one-quarter (1 4⁄ ) inch bar per slot

- STD Accuracy ±0.25% (0.1% available upon request.)

Dimensions in Inches, Tolerances: ±.015 for hole diameters.

Other tolerances ±.030 unless otherwise noted.

Dimensions are subject to change without notice.

50 mV Catalog Number AMP A B C D E F G H

205-2500-50 205-3000-50 205-4000-50

12 5 8⁄ 12 5 8⁄ 12 5 8⁄

1 1 2⁄

6 5 8⁄ 6 5 8⁄ 6 5 8⁄

7 16⁄ 7 16⁄ 7 16⁄

205-4500-50 205-5000-50 205-6000-50

12 5 8⁄ 12 5 8⁄ 12 5 8⁄

6 5 8⁄ 6 5 8⁄ 6 5 8⁄

7 16⁄ 7 16⁄ 9 16⁄

205-7000-50 205-7500-50 205-8000-50

12 5 8⁄ 12 5 8⁄ 12 5 8⁄

6 5 8⁄ 6 5 8⁄ 6 5 8⁄

9 16⁄ 9 16⁄ 9 16⁄

2 1 2⁄ 2 1 2⁄ 2 1 2⁄

1 1 4⁄ 1 1 4⁄ 1 1 4⁄

205-9000-50 205-10000-50

10000

12 5 8⁄ 12 5 8⁄

6 5 8⁄ 6 5 8⁄

9 16⁄

2 1 2⁄ 2 1 2⁄

1 1 4⁄ 1 1 4⁄

100 mV Catalog Number AMP A B C D E F G H 205-2500-100 205-3000-100 205-4000-100

14 1 4⁄ 14 1 4⁄ 14 1 4⁄

1 1 2⁄

8 1 4⁄ 8 1 4⁄ 8 1 4⁄

7 16⁄ 7 16⁄ 7 16⁄

205-4500-100 205-5000-100 205-6000-100

14 1 4⁄ 14 1 4⁄ 14 1 4⁄

8 1 4⁄ 8 1 4⁄ 8 1 4⁄

7 16⁄ 7 16⁄ 9 16⁄

205-7000-100 205-7500-100 205-8000-100

14 1 4⁄ 14 1 4⁄ 14 1 4⁄

8 1 4⁄ 8 1 4⁄ 8 1 4⁄

9 16⁄ 9 16⁄ 9 16⁄

2 1 2⁄ 2 1 2⁄ 2 1 2⁄

1 1 4⁄ 1 1 4⁄ 1 1 4⁄

205-9000-100 205-10000-100

10000

14 1 4⁄ 14 1 4⁄

8 1 4⁄ 8 1 4⁄

9 16⁄

2 1 2⁄ 2 1 2⁄

1 1 4⁄ 1 1 4⁄