The contract requires the manufacture of 100 each, 18-inch long base blocks in accordance with the Statement of Work, Drawing 149D1555 Rev. K, and specific welding requirements. The contractor must use Alloy 600 filler material per MIL-E-21562 and conduct liquid penetrant inspections of the cladding and membrane surfaces per specific acceptance criteria. Required documentation includes material test reports and written documentation that the inspection requirements were completed for each item. The contract opportunity is a Small Business Set Aside with a NAICS code of 332710 and a 500-employee size standard. Responses are due by 4:00 PM ET on January 17, 2024, and the contract will be awarded to the vendor that provides the Lowest Price Technically Acceptable offer.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JML DOC #: 3286V100, 3290V100 & 3290V101
Statement of Required Tests – Weld Mockup – 18” Long Base Block and Welding Membranes
Per Drawing 149D1555, Rev. K
1. WELDING REQUIREMENTS:
1.1. ALLOY 600 FILLER MATERIAL SHALL BE MIL-E-21562, TYPE EN/RN 82. NO SUBSTITUTIONS ARE
PERMITTED WITHOUT WRITTEN PERMISSION FROM PORTSMOUTH NAVAL SHIPYARD (PNS)
CODE 138.2 ENGINEERING.
1.2. FOLLOWING FINAL MACHINING, LIQUID PENETRANT INSPECT ALL ALLOY 600 CLAD SURFACES
PER T-9074-AS-GIB-010/271, TYPE 2, METHOD C, FORM E.
1.2.1. FOR THE INSPECTION, INCLUDE THE BASE MATERIAL AREA OF 1/2-INCH SURROUNDING
ALL CLADDING.
1.2.2. INDICATIONS ON THE THREE VERTICAL FACES OF THE CLADDING (0.3125-INCH THICK)
SHALL BE DISREGARDED.
1.2.3. INDICATIONS ALONG THE INTERFACE BETWEEN THE CLADDING AND BASE MATERIAL (18-
INCH LONG) SHALL BE DISREGARDED.
1.2.4. INDICATIONS WITHIN 1-INCH OF THE 2-INCH X 3.66-INCH FACES SHALL BE DISREGARDED.
1.2.5. WITHIN THE REMAINING CLAD AREAS (2 AREAS, EACH AT APPROXIMATELY 7/8-INCH X 16-
INCH), THE FOLLOWING ACCEPTANCE CRITERIA APPLY:
1.2.5.1. NO LINEAR INDICATIONS OF ANY SIZE ARE ALLOWED.
1.2.5.2. ROUNDED INDICATIONS LESS THAN OR EQUAL TO 1/64” ARE PERMITTED ON
CLAD SURFACE AS LONG AS THEY ARE EVENLY DISPERSED (NO MORE THAN TWO
INDICATIONS PER SQUARE INCH).
1.3. PROVIDE WRITTEN DOCUMENTATION THAT THE ABOVE INSPECTION REQUIREMENTS WERE
COMPLETED FOR EACH SERIALIZED ITEM IN THE CONTRACT.
1.4. PROVIDE SUPPLIER MATERIAL TEST REPORTS (CHEMICAL AND MECHANICAL) FOR BOTH THE
BASE MATERIAL (ASTM A515) AND WELD FILLER (MIL-E-21562).
1.5. FOLLOWING FINAL MACHINING, LIQUID PENETRANT INSPECT ALL MEMBRANE SURFACES PER
T-9074-AS-GIB-010/271, TYPE 2, METHOD C, FORM E. NO INDICATIONS ARE ALLOWED.