The solicitation is for 100 each, 18-inch long base blocks in accordance with the Statement of Work, Drawing 149D1555 Rev. K, and required testing outlined in Attachment 3. Offerors must provide technical documentation demonstrating their capabilities to fulfill the requirements. Award will be made to the vendor submitting the lowest price technically acceptable quote, with the right of the Contracting Officer to award based on ability to meet the required schedule. The procurement is a small business set-aside with a NAICS code of 332710 and a 500-employee small business size standard. Offers are due by 4:00 PM ET on January 17, 2024 and should be submitted via email. Vendor registration in the System for Award Management (SAM) is required.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3

Statement of Required Tests – Weld Mockup – 18” Long Base Block and Welding Membranes

Per Drawing 149D1555, Rev. K

1. WELDING REQUIREMENTS:

1.1. ALLOY 600 FILLER MATERIAL SHALL BE MIL-E-21562E, TYPE EN/RN 82. NO SUBSTITUTIONS ARE

PERMITTED WITHOUT WRITTEN PERMISSION FROM PORTSMOUTH NAVAL SHIPYARD (PNS)

CODE 138.2 ENGINEERING.

1.2. LIQUID PENETRANT INSPECT ALL ALLOY 600 CLAD SURFACES (VERTICAL AND HORIZONTAL) PER T9074-AS-GIB-010/271, Type 2, Method C, Form E. FOR THE INSPECTION, INCLUDE THE BASE

MATERIAL AREA OF 1/2 INCH SURROUNDING ALL CLADDING. NO LINEAR INDICATIONS OF ANY

SIZE, ROUNDED INDICATIONS LESS THAN OR EQUAL TO 1/64 INCH ARE PERMITTED ON CLAD

SURFACE AS LONG AS THEY ARE EVENLY DISPERSED (NO MORE THAN TWO INDICATIONS PER

SQUARE INCH). ONLY THE TOP (HORIZONTAL) SURFACE OF THE CLADDING NEEDS TO BE

INSPECTED. SIDE (VERTICAL) SURFACES MAY BE OMITTED.

1.3. PROVIDE WRITTEN DOCUMENTATION THAT THE ABOVE INSPECTION REQUIREMENTS WERE

COMPLETED FOR EACH SERIALIZED ITEM IN THE CONTRACT.

1.4. PROVIDE SUPPLIER MATERIAL TEST REPORTS (CHEMICAL AND MECHANICAL) FOR BOTH THE

BASE MATERIAL (ASTM A515-17) AND WELD FILLER (MIL-E-21562E).