This document contains questions and answers regarding hydraulic oil flushing services on a Los Angeles-class submarine. The services will include flushing approximately 300 gallons of hydraulic piping ranging in diameter from 2 to 2-1/2 inches using a maximum pressure of 3600 psi and nominal pressure of 1500 psi to attain a flow rate of 30 gallons per minute. The flushing will occur pier side and take approximately 1000 gallons of final fill oil in addition to the flushing oil. Standard connection sizes will be -16 JIC/1 inch. Completion criteria is a water content of less than or equal to 0.05% as specified in SUBMEPP TP 553-5542. Visual inspection is not required.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers Rev 2.docx | DOCX document | |
| N3904021R0005.pdf | ||
| Attachment 1 WD.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers Rev 1. 10/13/20
1) Is 480V 3-phase 100amp power available from shipyard or is the KTR to provide a generator to run flushing rig. YES San Diego Det. will provide
2) What is the diameter of the piping that will be flushed on the external hydraulics? (This will be used to determine the required flow rate for flushing) or if there is already a NAVAL required flow rate can you provide that? ¼” to 2-1/2” IPS
3) SOW states that KTR is to provide flushing oil and 1000 gallons of Final Fill oil. Do you know how many gallons of oil is needed to fill the entire external hydraulic piping system that will be in the flushing circuit? ~ 300 Gallons.
4) Is the BOAT in the dry dock for this flushing evolution? The Ship will be pier side flushing will occur over water.
5) Does the Shipyard know the size and type of connections the KTR equipment will need to connect too? The standard size of connection will be -16 JIC / 1 Inch
6) What is the PASS/FAIL criteria for completion of the hydraulic flushing phase? NAS Class 5 with less than or equal to .05% water content
7) Is there a visual flush screen or filter bag inspection? Not Required for this flush procedure
8) # At what pressure will the flushing be completed at? Max pressure is 3600 psi Nominal is 1500 psi
9) What is the diameter and length of the piping/any drums to be flushed. Need flush approximately 40 55gal drums, Any portable piping will be flushed in SD-Det shop
10) What are the flow rates to be attained? 30 Gallons per minute (30GPM)
11) can we get a copy of the flushing procedure to be used to assure the right flushing equipment is used onsite – The flush is conducted in accordance with SUBMEPP TP 553-5542. Please contact the POC on this solicitation for a copy.