Statement of Work Installation of 246 training trailer
STATEMENT OF WORK
I. Title: Delivery and setup of portable classroom trailer for
Code 246. Trailer to be located between buildings 175 and 174 inside the controlled industrial area (CIA)at the Portsmouth Naval
Shipyard
II. Technical Point of Contact (TPOC): Mark Callahan, Code 981, is the Portsmouth Naval Shipyard TPOC. The TPOC will provide contractor directions to placement of the code 246 training trailer. TPOC will ensure all services, i.e., electrical, communications, water and sewer, are ready to be connected prior to execution of this contract. Contractor shall notify the Navy’s
TPOC prior to commencing and upon completion of services.
III. Period of Performance: (POP):
IV. Background: 246 training trailer is needed to allow sufficient training space adjacent to building 174..
V. Scope of Work: Contractor shall provide all labor, material, and tools required to deliver, and setup 246 training trailer. The
246 training trailer location is identified on Enclosure (1) and shall be positioned with the tongues facing east. Contractor shall ensure the trailer’s interior seam at the connection is linear, neat, and secure. Contractor shall be responsible for properly leveling the trailer. Contractor shall remove all excess material and waste generated by the move, and shall leave the site in a neat and orderly fashion.
VI. SECURITY: No person not known to be an American citizen of good standing and repute shall be allowed access to Portsmouth
Naval Shipyard. Proof of citizenship may be required.
VII. Trailer specs:
Standard Minimum Requirements that shall be met or exceeded for standard trailer rental
Size: approx. 68’ x 28’ rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text June 1, 2015 and extended to May 31, 2016 rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text with options for two (2) additional years.
rebekah.needham Typewritten Text
Portable class room trailer to include:
Entrance vestibule (see sketch)
2 class rooms approx. 725 square feet each.
2 unisex bathrooms with entrance off vestibule
Storage closet for each class room
Interior Walls:
Studs: 2 x 4 or 2 x 6 @ 16” oc, 8’-0” high
Interior: 1/2” Painted gypsum
Insulation: R-14 minimum
Interior Trim:
Base: 4” Vinyl cove base, except 6” Vinyl cove base in bathroom
Ceiling/Wall: White Suspended ceiling wall angle
Roof:
Rafters: (Min) 2 x 8 Roof rafters @ 16” oc spacing min 4/12 pitch
Insulation: R-30 minimum
Sheathing: 7/16” OSB w/ 1/4” DensDeck
Aluminum Gutters: J-Rail along length with site installed Aluminum Gutters and downspouts
Asphalt shingles or standing seam metal roof
Windows:
Size/Qty: (Min) 3/0 x 4/0; 4 per class room
Type: White vinyl framed single hung vertical slider, w/Fiberglass insect screens
Glazing: LOW E double insulated glass
Blinds: 1” Vinyl mini blinds
Interior Doors:
Size/Type: 3/0 x 6/8 Solid core pre-finished wood grain
Keyed entry lever set
Floor mounted doorstops
Exterior Doors:
Size: 3/0 x 6/8
Type: Pre-hung 20ga Commercial steel or fiberglass door w/18ga steel frame; painted
Hardware: 4.5” x 4.5” NRP ball bearing hinges
5” x 20” Vision Panel
Door Closer
Panic Bar Panic hardware
Exterior keyed lever trim
Weather-stripping, Aluminum threshold and drip cap
Exterior Finish:
Stairs and landing for each door.
Vinyl or aluminum siding
Standard drip rail gutters
Rain diverters above door openings
Skirting from base of unit to ground level
Power gable end roof ventilation system
Units shall have a maximum of 2 load columns located on the centerline of seamed units; columns shall be integrated into interior partition walls.
Removable Tongue
Sufficient tie downs straps to meet or exceed industrial standards
HVAC:
Equipment: end wall mounted stepped capacity, green refrigerant, AC/ heat pump unit
Supply: F/G in ceiling w/24” x 24” Grid mounted adjustable diffusers
Return: F/G in ceiling w/24” x 24” Grid mounted grilles
Exhaust: 150-cfm exhaust fan
Thermostat: 7-Day Programmable heat/cool
Electrical:
Work/Unit shall meet current:
a. NFPA 70 - National Electrical Code
b. NFPA 101 - Life Safety Code
Disconnect: (Min) Exterior 100 amp fused or breaker controlled 120/240 V Single phase duel pole disconnect. Whip provided by customer.
Panel: (Min) 100 amp interior panel with GFCI breakers for all 120v receptacles
Lights: grid mounted fluorescent lights w/T-8 lamps and protective covers
Ext Lights: Fluorescent or LED lights w/Battery back-up emergency feature @ exterior doors (Photocell controlled)
120V/15A under floor heat tape receptacle w/In use waterproof cover (for heat tracing of water supply lines;
heat tape provided by others)
Switch: 120V/15A White Toggle switch, as needed (Dual switched per IECC)
Emergency: Dual head exit/emergency light w/ 90 Minute battery backup
Exit signs: All exits must have exit signs. Illuminated signs are preferred; however, self-luminous signs with a minimum luminance surface value of at least .06 foot-lamberts are permitted.
Voice/Data: Locations w/double gang boxes and 1/2” flexible conduit terminating above ceiling for equipment to be installed on site. Exterior entry for data and phone lines terminating above ceiling
Fire Alarm: Locations w/Single gang metal boxes and 1/2” EMT conduit to above ceiling for equipment
Plumbing:
Supply: Type ‘L’ copper pipe & fittings
Waste: Schedule 40 PVC pipe & fittings DWV
Water Heater: 6-Gallon tank type w/plastic water heater pan
Lavatory: ADA Accessible wall hung china
Electronic Faucet: W/ a 4-3/4” (12.1 cm) spout, brass constructed, and electronic infrared sensor
Toilet: Low Flow - (2) ADA Accessible handicapped Elongated bowl tank type toilet, Fiberglass service sink: 24” x 24” w/8” swivel faucet
Mirror: 18” x 30” Framed Mirror
Grab Bar: Stainless steel grab bar, Partitions: Overhead braced enameled steel modesty partition and handicapped modesty partition
Enclosure 1
Sample layout
Enclosure 2