Statement of Work Installation of 246 training trailer

STATEMENT OF WORK

I. Title: Delivery and setup of portable classroom trailer for

Code 246. Trailer to be located between buildings 175 and 174 inside the controlled industrial area (CIA)at the Portsmouth Naval

Shipyard

II. Technical Point of Contact (TPOC): Mark Callahan, Code 981, is the Portsmouth Naval Shipyard TPOC. The TPOC will provide contractor directions to placement of the code 246 training trailer. TPOC will ensure all services, i.e., electrical, communications, water and sewer, are ready to be connected prior to execution of this contract. Contractor shall notify the Navy’s

TPOC prior to commencing and upon completion of services.

III. Period of Performance: (POP):

IV. Background: 246 training trailer is needed to allow sufficient training space adjacent to building 174..

V. Scope of Work: Contractor shall provide all labor, material, and tools required to deliver, and setup 246 training trailer. The

246 training trailer location is identified on Enclosure (1) and shall be positioned with the tongues facing east. Contractor shall ensure the trailer’s interior seam at the connection is linear, neat, and secure. Contractor shall be responsible for properly leveling the trailer. Contractor shall remove all excess material and waste generated by the move, and shall leave the site in a neat and orderly fashion.

VI. SECURITY: No person not known to be an American citizen of good standing and repute shall be allowed access to Portsmouth

Naval Shipyard. Proof of citizenship may be required.

VII. Trailer specs:

Standard Minimum Requirements that shall be met or exceeded for standard trailer rental

Size: approx. 68’ x 28’ rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text June 1, 2015 and extended to May 31, 2016 rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text rebekah.needham Typewritten Text with options for two (2) additional years.

rebekah.needham Typewritten Text

Portable class room trailer to include:

Entrance vestibule (see sketch)

2 class rooms approx. 725 square feet each.

2 unisex bathrooms with entrance off vestibule

Storage closet for each class room

Interior Walls:

Studs: 2 x 4 or 2 x 6 @ 16” oc, 8’-0” high

Interior: 1/2” Painted gypsum

Insulation: R-14 minimum

Interior Trim:

Base: 4” Vinyl cove base, except 6” Vinyl cove base in bathroom

Ceiling/Wall: White Suspended ceiling wall angle

Roof:

Rafters: (Min) 2 x 8 Roof rafters @ 16” oc spacing min 4/12 pitch

Insulation: R-30 minimum

Sheathing: 7/16” OSB w/ 1/4” DensDeck

Aluminum Gutters: J-Rail along length with site installed Aluminum Gutters and downspouts

Asphalt shingles or standing seam metal roof

Windows:

Size/Qty: (Min) 3/0 x 4/0; 4 per class room

Type: White vinyl framed single hung vertical slider, w/Fiberglass insect screens

Glazing: LOW E double insulated glass

Blinds: 1” Vinyl mini blinds

Interior Doors:

Size/Type: 3/0 x 6/8 Solid core pre-finished wood grain

Keyed entry lever set

Floor mounted doorstops

Exterior Doors:

Size: 3/0 x 6/8

Type: Pre-hung 20ga Commercial steel or fiberglass door w/18ga steel frame; painted

Hardware: 4.5” x 4.5” NRP ball bearing hinges

5” x 20” Vision Panel

Door Closer

Panic Bar Panic hardware

Exterior keyed lever trim

Weather-stripping, Aluminum threshold and drip cap

Exterior Finish:

Stairs and landing for each door.

Vinyl or aluminum siding

Standard drip rail gutters

Rain diverters above door openings

Skirting from base of unit to ground level

Power gable end roof ventilation system

Units shall have a maximum of 2 load columns located on the centerline of seamed units; columns shall be integrated into interior partition walls.

Removable Tongue

Sufficient tie downs straps to meet or exceed industrial standards

HVAC:

Equipment: end wall mounted stepped capacity, green refrigerant, AC/ heat pump unit

Supply: F/G in ceiling w/24” x 24” Grid mounted adjustable diffusers

Return: F/G in ceiling w/24” x 24” Grid mounted grilles

Exhaust: 150-cfm exhaust fan

Thermostat: 7-Day Programmable heat/cool

Electrical:

Work/Unit shall meet current:

a. NFPA 70 - National Electrical Code

b. NFPA 101 - Life Safety Code

Disconnect: (Min) Exterior 100 amp fused or breaker controlled 120/240 V Single phase duel pole disconnect. Whip provided by customer.

Panel: (Min) 100 amp interior panel with GFCI breakers for all 120v receptacles

Lights: grid mounted fluorescent lights w/T-8 lamps and protective covers

Ext Lights: Fluorescent or LED lights w/Battery back-up emergency feature @ exterior doors (Photocell controlled)

120V/15A under floor heat tape receptacle w/In use waterproof cover (for heat tracing of water supply lines;

heat tape provided by others)

Switch: 120V/15A White Toggle switch, as needed (Dual switched per IECC)

Emergency: Dual head exit/emergency light w/ 90 Minute battery backup

Exit signs: All exits must have exit signs. Illuminated signs are preferred; however, self-luminous signs with a minimum luminance surface value of at least .06 foot-lamberts are permitted.

Voice/Data: Locations w/double gang boxes and 1/2” flexible conduit terminating above ceiling for equipment to be installed on site. Exterior entry for data and phone lines terminating above ceiling

Fire Alarm: Locations w/Single gang metal boxes and 1/2” EMT conduit to above ceiling for equipment

Plumbing:

Supply: Type ‘L’ copper pipe & fittings

Waste: Schedule 40 PVC pipe & fittings DWV

Water Heater: 6-Gallon tank type w/plastic water heater pan

Lavatory: ADA Accessible wall hung china

Electronic Faucet: W/ a 4-3/4” (12.1 cm) spout, brass constructed, and electronic infrared sensor

Toilet: Low Flow - (2) ADA Accessible handicapped Elongated bowl tank type toilet, Fiberglass service sink: 24” x 24” w/8” swivel faucet

Mirror: 18” x 30” Framed Mirror

Grab Bar: Stainless steel grab bar, Partitions: Overhead braced enameled steel modesty partition and handicapped modesty partition

Enclosure 1

Sample layout

Enclosure 2