246_training_trialer_STATEMENT_OF_WORK.docx

DOCX document 200 KB Posted

Attached to
Rental of Portable Trailer (Training Room)
Solicitation number
N39040-15-T-0244
Issued by

About this file

Specifications

View the file

Other files

File Type Posted
Classroom_Trailer_RFQ.doc DOC document
246_training_trialer_STATEMENT_OF_WORK.docx DOCX document
Classroom_Trailer_RFQ.doc DOC document
Classroom_Trailer_RFQ.doc DOC document
Statement_of_Work.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

I. Title: Delivery and setup of portable classroom trailer for code 246. Trailer to be located between buildings 175 and 174 inside the controlled industrial area(CIA)at the Portsmouth Naval Shipyard II. Technical Point of Contact (TPOC): Mark Callahan, Code 981, is the Portsmouth Naval Shipyard TPOC. The TPOC will provide contractor directions to placement of the code 246 training trailer. TPOC will ensure all services, i.e., electrical, communications, water and sewer, are ready to be connected prior to execution of this contract. Contractor shall notify the Navy’s TPOC prior to commencing and upon completion of services.

III. Period of Performance: (POP):

IV. Background: 246 training trailer is needed to allow sufficient training space adjacent to building 174..

V. Scope of Work: Contractor shall provide all labor, material, and tools required to deliver, and setup 246 training trailer. The 246 training trailer location is identified on Enclosure (1) and shall be positioned with the tongues facing east. Contractor shall ensure the trailer’s interior seam at the connection is linear, neat, and secure. Contractor shall be responsible for properly leveling the trailer. Contractor shall remove all excess material and waste generated by the move, and shall leave the site in a neat and orderly fashion.

VI. SECURITY: No person not known to be an American citizen of good standing and repute shall be allowed access to Portsmouth Naval Shipyard. Proof of citizenship may be required.

VII. Trailer specs:

Standard Minimum Requirements that shall be met or exceeded for standard trailer rental Codes:

Work/Unit shall meet current:

International Building code (IBC) for Kittery Maine NFPA 70 - National Electrical Code NFPA 101 - Life Safety Code

Size: approx. 68’ x 28’ Portable class room trailer to include:

a. Entrance vestibule

b. 2 class rooms approx. 750 square feet.

c. 2 unisex bathrooms with entrance off vestibule

d. Storage closet for each class room

Interior Walls:

Studs: 2 x 3 & 2 X 4 @ 16” oc, 8’-0” high Interior: 1/2” Painted gypsum Insulation: R-11 minimum

Interior Trim:

Base: 4” Vinyl cove base, except 6” Vinyl cove base in bathroom Ceiling/Wall: “White” Suspended ceiling wall angle

Roof:

Rafters: 2 x 8 Roof rafters @ 16” oc spacing Insulation: R-30 minimum Sheathing: 7/16” OSB w/ 1/4” Dens Deck Aluminum Gutters: J-Rail along length with site install Aluminum Gutters

Windows:

Size/Qty: 3/0 x 4/0. 4 per class room Type: “White” vinyl framed single hung vertical slider, w/Fiberglass insect screens Glazing: “LOW E” double insulated glass Blinds: 1” Vinyl mini blinds

Interior Doors:

Size/Type: 3/0 x 6/8 Solid core pre-finished wood grain Keyed entry lever set Floor mounted doorstops

Exterior Doors:

Size: 3/0 x 6/8 Type: Pre-hung 20ga Commercial steel door w/18ga steel frame Hardware: 4.5” x 4.5” NRP ball bearing hinges 5” x 20” Vision Panels Door Closer Panic Bar Panic hardware Exterior keyed lever trim Weather-stripping, Aluminum threshold and drip cap

Exterior Finish

1) Stairs and landing for each door.

2) Aluminum/Vinyl siding

3) Standard drip rail gutters

4) Rain diverters above door openings

5) Skirting from base of unit to ground level

6) Power gable end roof ventilation system

7) Units shall have a maximum of 1 load column located on the centerline of seamed units

8) Removable Tongue

9) Shall provide a sufficient amount of tie downs straps that meet or exceed industrial standards

HVAC:

Equipment: end wall mounted stepped capacity, green refrigerant, AC/ heat pump unit Supply: F/G in ceiling w/24” x 24” Grid mounted adjustable diffusers Return: F/G in ceiling w/24” x 24” Grid mounted grilles Exhaust: 150-cfm exhaust fan Thermostat: 7-Day Programmable heat/cool

Electrical:

Disconnect: Exterior 200 amp fused or breaker controlled 110/208V Single phase / 4 Wire disconnect. Whip provided by customer.

Panel: 100 amp interior panel with GFCI breakers for all 120v receptacles Lights: grid mounted fluorescent lights w/T-8 lamps and protective covers Ext Lights: Fluorescent or LED lights w/Battery back-up emergency feature @ exterior doors (Photocell controlled) 120V/15A Exterior heat tape receptacle w/In use waterproof cover Switch: 120V/15A “White” Toggle switch, as needed (Dual switched per IECC) Emergency: Dual head exit/emergency light w/ 90 Minute battery backup Exit signs: All exits must have exit signs. Illuminated signs are preferred; however, self-luminous signs with a minimum luminance surface value of at least .06 foot-lamberts are permitted.

Voice/Data: Locations w/double gang boxes and 1/2” flexible conduit above ceiling for equipment to be installed on site. Exterior entry for data an phone lines Fire Alarm: Locations w/Single gang metal boxes and 1/2” EMT conduit to above ceiling for equipment

Plumbing:

Supply: Type ‘L’ copper pipe & fittings Waste: Schedule 40 PVC pipe & fittings Water Heater: 6-Gallon tank type w/plastic water heater pan Lavatory: ADA Accessible wall hung china Electronic Faucet: W/ a 4-3/4” (12.1 cm) spout, brass constructed, and electronic infrared sensor Toilet: Low Flow - ADA Accessible handicapped Elongated bowl tank type toilet, Fiberglass service sink: 24” x 24” w/8” swivel faucet Mirror: 18” x 30” Framed Mirror Grab Bar: Stainless steel grab bar, Statement of Work Installation of 246 training trailer

Enclosure 1 Trailer location

Sample layout Enclosure 2 image1.emf image2.emf

File details come from the government source that posted it. Updated .