Wholehouse Revitalization - Las Palmeras Phase III 1111239 NAVSTA Rota, Spain qualifications shall be as required by EM 385-1-1 paragraph 01.A.17 and all associated sub-paragraphs. To meet the EM 385-1-1 annual training requirements the SSHO may elect to accomplish applicable sections (lessons) of the web based EM 385-1-1 training. For purposes of this contract completion of each EM 385-1-1 training module (lesson) verified by the printed certificate is considered credit for four hours of training. The training may be accessed at the following link:

http://63.88.8.194/construction/index.html. indicated below. SSHO shall possess degree from medium degree university (aparejador, ingeniero tecnico) with at least 3 years experience as a safety manager in similar projects and qualified as "Tecnico Supervisore PRL". A competent person shall be provided for all of the hazards identified in the Contractor's Safety and Health Program in accordance with the accepted Accident Prevention Plan, and shall be on-site at all times when the work that presents the hazards associated with their professional expertise is being performed. The credentials of the Competent Persons(s) shall be approved by the Contracting Officer in consultation with the Safety Office. Site Safety and Health Officer (SSHO) shall perform safety and occupational health management, surveillance, inspections, and safety enforcement for the Contractor. The assignment of the SSHO contractually does not relieve the Contractor from the regulatory requirements governing safety responsibility.

1.5.1.2 Crane Operators

Meet the crane operator's requirements in USACE EM 385-1-1. In addition, for mobile cranes with Original Equipment Manufacturer (OEM) rated capacitates of 50,000 pounds or greater, designate crane operators as qualified by a source that qualifies crane operators(i.e., union, a government agency, or and organization that tests and qualifies crane operators). Provide proof of current qualification.

1.5.1.3 Competent Person for Confined Space Entry

Provide a competent person for confined space meeting the definition and requirements of EM 385-1-1. If work involves marine operations that handle combustible or hazardous materials, this person shall have the ability to understand and follow through on the air sampling, PPE, and instructions of a Marine Chemist, Coast Guard authorized persons, or Certified Industrial Hygienist. All confined and enclosed space work shall comply with NFPA 306, OSHA 29 CFR 1915, Subpart B, "Confined and Enclosed Spaces and Other Dangerous Atmospheres in Shipyard Employment" or as applicable, 1910.147 for general industry.

1.5.2 Personnel Duties

1.5.2.1 Site Safety and Health Officer (SSHO)

In addition to duties required in EM 385-1-1, perform the following duties:

a. Conduct daily safety and health inspections and maintain a written deficiency tracking log which includes area/operation inspected, date of inspection, identified hazards, recommended corrective actions, estimated and actual dates of corrections. Safety inspection logs shall be attached to the Contractors' daily production report and posted at the jobsite.

b. Shall have no other duties other than safety and occupational health management, inspections, enforcement, on this contract.

RFP PART 2 - Section UFGS 01 35 26.05 20 Page 5