SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
AMENDMENT 04
Amendment N32205-16-R-4206-0004 is being issued to delete Work Item (WI) 501 – T-ALT 240 Paint Mixing Room Ventillation Modifications from WI package.
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
C – 2 List of Standard Work Items included for this solicitation:
WI
Type Description
000 GENERAL REQUIREMENTS
NSP
Intent, Scope, general, and Definitions
NSP
Technical and Manufacture's Representatives
NSP
Approach, Berth, and Mooring Requirements
NSP
Testing & Quality Assurance
NSP
Electrical Safety Procedures and Requirements
NSP
Heavy Weather Plan
NSP
Cold Weather Plan
A Furnish Office for OMT
A General Services for the Ship T-AOE
A Telephone Services
A Project Planning and Monitoring
A Weight and Moment report
A
ILS, GFM
A Fire Protection and Ship's Safety Program
A Handling Ship's Stores
A Delivery and Redelivery
A Shipboard Access
NSP
Gas Free Certificates
A Clean and Gas Free Tanks, Voids, and Cofferdams
A Dock Trials and Sea Trials
A Hazardous Waste Disposal
A Physical Security at Private Contractor's Facility
B Physical Security at Private Contractor's Facility
B Continuation of Services
100 STRUCTURAL
A DFM Contaminated Tank 7-430-0-F, Repair (VR15-095/CASREP)
A
REPAIR TO BLKHD ELEV MACHY ROOM 2 (VR15-063)
A
REPAIR HOLED VENT PLENUM AND FAN (S-1-399-1)IN POL (VR15-094)
A MMR No.1 EXTERIOR BERP REFURBISHMENT (VR15-090)
A
PRESERVE REFRIGERATED STORES SPACES DRAIN TANK (VR15-078)
A Replace Bulkhead Stringer AMR (VR15-060)
A
ESCAPE TRUNK (6-510-2-T) REFURBISHMENT(VR15-025)
A
ESCAPE TRUNK (6-455-2-T) REFURBISHMENT(VR15-023)
A 03 Level CIC Conversion to State Rooms
300 ELECTRICAL
A SSDG Flex Hose Replacement (VR15-055-059)
A Switchboard Cleaning (LCM)
AC PLANT MOTOR 1 AND 2; REFURBISH
400 ELECTRONICS
A Radar Groom
A GMDSS Groom and Inspection
A TV-DTS Groom
A
BRIDGE OPTICS REFURBISHMENT
A Antenna preventative maintenance
500 AUX EQUIPMENT
A Weather Deck Drain Repairs (VR15-092)
A Replace Mech Seal Port Anchor Windlass (VR15-085)
A Replace Mag Sprink Isolation Valves (VR15-082)
A Vent Duct Repair- AMR pump Room (VR15-073)
A Vent Duct Repair- 1-336-2 (VR15-071)
A Inspect Steering Gear RAM Bushings (VR15-068)
A 02 Level Vent Repairs (VR15-064)
A SSDG No1 EXHAUST- INSULATION REPLACEMENT
A HPAC Air Hoses - Replace
A Soil Line Repair MMR 2
A Install Duplex Strainer to Domestic Reefer
A Groom and Weight Test Port and STBD RHIBs and Davit
A Replace HP Air Union Nuts A
01 LEVEL WEATHER DECK VENT REPAIR
A
CONTAMINATED TANK VENT MODIFICATIONS
REPLACE PURIFIER HEATERS
600 HABITABILITY
A Interior Deck Repairs
A
REPLACE 03 LEVEL NON-SKID ABOVE HELO (VR15-032)
A Galley Groom
A Refrigerated Deck Installation
Liferaft Certification
800 HVAC
Ventillation Cleaning
1000 UNREP/VERTREP
A
SLIDING BLOCK NO.4 ELEC MTR AND BRAKE ASSEMBLY REFURB (VR15-069)
A Saddle Winch Motor Replace Studs
A Ram Tensioner Acummulator Piston Seals Station 7
A
SLIDING BLOCK NO.5 ELEC MTR AND BRAKE ASSEMBLY REFURB (VR15-076)
(End of Summary of Changes)