Attachment_II_-_Vendor_questions_and_Government_answers.xlsx

XLSX spreadsheet 11 KB Posted

Attached to
Telephone Switch Maintenance
Solicitation number
N0040618Q0208
Issued by

About this file

Attachment_II_-_Vendor_questions_and_Government_answers.xlsx

View the file

Other files

File Type Posted
N00406-18-Q-0208-0002.docx DOCX document
N00406-18-Q-0208-0001.docx DOCX document
Attachment_I_-_List_of_Switches.doc DOC document
N00406-18-Q-0208.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Question NumberRFP Document/Section/Page NumberClarification Question or CommentComments for KO
1PWS 1.0, Page 3“This sustainment support will also include routine and emergency technical assistance, as well as repair and return of unserviceable telephone switch and power supply components throughout the NAVCOMTELSTA FAR EAST Area of Responsibility (AOR) as listed in Paragraph 3.0 below.”For this soliciation the government defines power supplies as the internal power supplies within the switching cabinets. This is not in reference to DC power plants, UPS, and/or battery plants.
Does the Government define power supplies as the internal power supplies within the switch systems cabinet or does the Government define power supplies as external components such as DC power plants, UPSs and battery plants?
2PWS 1.0, Page 3If the Government defines power supplies as external components such as DC power plants, UPSs and battery plants, will the Government please provide a itemized list of power components to be covered under this solicitation?Reference 1 above.
3Will the Government please provide a POC (Name and Email address) to electronically authorize the offeror to obtain records for the Avaya Communication Manager sites?The government will not authorize third party requests for records.
4Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the NAF Atsugi Main Nortel Opt 11C is D19856? According to the OEMs records this serial number is a Option 61C with 16 digital and 16 Analog licenses.Serial number is correct but the model number was listed incorrect. It is an Option 61C.
5Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the Yokosuka Main Opt 11C #1 is 107417? This serial number does not show up in the OEM records.Confirmed correct serial number listed.
6Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the Yokosuka Main Opt 11C #2 is 90016? According to the OEMs records this serial number is a Option 61C with 528 digital and 1872 Analog licenses.Confirmed correct serial number listed. This is an Option 11C collocated with the SL-100.
7Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the Hakozaki POL Meridian Opt 11Cis 04T1TZ(Main)/05T520(Ext.)? These serial numbers do not show up in the OEM records.Confirmed correct serial number listed.
8Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm the number of licenses on the Ikego Housing Meridian Opt 81C? According to the OEMs records this site has 112 digital and 3168 Analog licenses.Without a major equipment replacement, the maximum capacity is 2,880 analog lines. Current configuration of 1,392 analog and 32 digital were given in the RFP. No major capacity increases are expected by the government at this time.
9Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the Tsurumi POL Opt 11C is 69421? This serial number does not show up in the OEM records.Confirmed correct serial number listed.
10Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the Urago Ordinance 11C is 04C190? This serial number does not show up in the OEM records.Confirmed correct serial number listed.
11Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm the number of licenses for the Negishi Housing Meridian CS1000M? According to the OEMs records this site has 16 digital, 32 IP and 1008 Analog licenses.Without a major equipment replacement, the maximum capacity is 1008 analog lines. Current configuration of 800 analog and 32 digital were given in the RFP. No major capacity increases are expected by the government at this time.
12Appendix A: NCTSFE Telephone Switch MatrixCan the Government confirm that the serial number for the MWR (B1559) Meridian Opt 11C is 71019? This serial number does not show up in the OEM records.Confirmed correct serial number listed.