B_46_67_Library_Final_Design_Drawings.pdf

PDF 4 MB Posted

Attached to
Naval History and Heritage Command Relocation Services Federal contract opportunity
Solicitation number
N0018922Q0464
Issued by
Department of the Navy Naval Supply Systems Command

About this file

This document package includes final design drawings and specifications for the relocation services of the Photo Archives and Navy Department Library for the Naval History and Heritage Command. The drawings detail the required renovations to Buildings 46 and 67 on the Washington Navy Yard, including new partitions, finishes, mechanical and electrical systems, and ADA accessibility improvements. The related federal contract opportunity solicits proposals to provide packing, crating, moving, and rehousing services for the historic artifacts, collections, and library holdings under the cognizance of the Naval History and Heritage Command. The solicitation was issued by the Department of the Navy Naval Supply Systems Command and requires all necessary labor, equipment, facilities and materials to complete the relocation.

View the file

Other files for this federal contract opportunity

Other files attached to Naval History and Heritage Command Relocation Services, newest first.
File Type Posted
B_46_67_Library_Shelving_Drawings.pdf PDF
N0018922Q0464 0001 conformed.pdf PDF
N0018922Q0464 0001.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WASHINGTON NAVY YARD, WASHINGTON, DC

FINAL SUBMISSION

JULY 10, 2020

15020 SHADY GROVE RD, ST 500

ROCKVILLE, MD 20850

(240)-399-2000

STRUCTURAL ENGINEER:

THORNTON TOMASETTI

2000 L STREET NW, SUITE 600

WASHINGTON, DC 20036

(202)-580-6300

3307 M STREET NW, SUITE 301

WASHINGTON, DC 20007

(202)-333-8000

WNY 46-67 OPERATIONAL ARCHIVES AND

RESEARCH REPOSITORY

LIFE SAFETY:

JENSEN HUGHES

3610 COMMERCE DR, SUITE 817

BALTIMORE, MD 21227

(410)-737-8677

MEP ENGINEER:

JAMES POSEY ASSOCIATES

11155 RED RUN BLVD, SUITE 310

BALTIMORE, MD 21117

(410)-265-6100

AV/TELECOM:

CONVERGENT TECHNOLOGIES

6501 YORK ROAD

BALTIMORE, MD 21212

(410)-532-2395

CIVIL ENGINEER:

LANGAN

1300 WILSON BLVD, SUITE 450

ARLINGTON, VA 22209

(571)-366-6800

VERTICAL TRANSPORTATION:

VERTRAN ENTERPRISES

14 OAK COURT

ANNAPOLIS, MD 21401

(410)-571-0001

FOR OFFICIAL USE ONLY

SHEET OF

NAVFAC DRAWING NO.

CONST. CONTR. NO. N4008018C0033

13129099

SHEET OF

NAVFAC DRAWING NO.

CONST. CONTR. NO. N4008018C0033

DN

UP

UP

UP

UP

UP

UP

UP

UP

UP

12 14

1 3 15

A

B

C

D

F

G

H

J

K

A2014

A201

A303

A303

A303

A301 2

A301

A302

A302

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

11.7

E

14.7

9' - 7 1/2" 22' - 6" 17' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 21' - 0" 21' - 0" 21' - 0" 17' - 0" 21' - 1" 12' - 1"

/1 A401B

/1 A401B

A302

UA

MACRO

LOADING

DOCK

UA DIVE

LOCKER

UA FIELD

EQUIP

CORRIDOR

S1-1

STAIR 01

CONFERENCE

E-1

ELEV

ELEV

MACH

REFERENCE

MICROFORM

RARE

BOOK

ROOM

RECEPTION

BREAK

STOR.

OFFICE144

STAFF

OFFICES

OFFICE

HEAD

OFFICE115

WATER

SERVICE114

ELEC

FIRE

PUMP

STACKS

VEST

S2-1

STAIR 02

COMM

CORRIDOR

UA

ENTRANCE

UA CHEM

STORAGE

UA LAB

UA

CURATION

UA

CURATION

STORAGE127

STORAGE

ART

SHOP

ART

OPEN

OFFICE

RR

ART

OPEN

OFFICE

15.213.712.710.79.78.77.76.7

ART

STORAGE

COMM

WOMEN'S

MEN'S

OFFICE

JAN

/1 A401A

/1 A401A

26' - 0" 246' - 4" 34' - 4"

30' - 11"

LOADING

DOCK

CRANE

ABOVE

127B

ELEC

CLOSET

MAIN

ENTRY

VESTIBULE

+0.500

+0.500

+0.000

+0.500 +0.000

+0.00 ELEVATION

REPRESENTS

EXISTING SLAB AND

MAY VARY.

COORDINATION

WITH DATUM POINT

NOTED ON A011.

SEE CIVIL FOR

GRADING, TYP

SEE CIVIL FOR

GRADING, TYP

SEE CIVIL FOR

GRADING, TYP

SEE CIVIL FOR GRADING, TYP

+0.000

RE-STRIPE PARKING,

SEE CIVIL FOR

OTHER STREET

IMPROVEMENTS

M

IN

3 3

3 3

HARWOOD ST

M A

T C

H L

IN

E

GENERAL SHEET NOTES:

1. SEE ENLARGED PLANS A401A-A402B FOR PARTITION TYPES, DOOR TAGS, AND DIMENSIONS.

2. SEE 121A-A122B FOR RCPS.

3. SEE A641 FOR MATERIAL/FINISH SHEDULE.

4. SEE A80X SERIES FOR FURNITURE PLANS.

5. SEE A81X SERIES FOR FINISH PLANS.

6. SEE A82X SERIES FOR SIGNAGE PLANS.

7. VERIFY ALL EXISTING CONDITIONS IN FIELD.

Beyer Blinder Belle Architects and Planners, LLP 3307 M Street NW, Suite 301 Washington, DC 20007 202 333 8000

W N

Y

-6

O

P E

R A

T

IO

N A

L A

R C

H

IV

E S

A N

D

R E

S E

A R

C H

R E

P O

S

IT

O R

Y

N O

D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

W A S H

IN

G T O N D C

W A S H

IN

G T O N

N A V Y

Y A R D

D

D E P A R T M E N T

O F

T H E

N A V Y

SHEET

A

B

C

1 2 3 4 5

1 2 3 4 5

OF

NAVFAC DRAWING NO.

CONST. CONTR. NO.

EPROJECT NO.:

SCALE:

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

W

A S

H

IN

G T

O N

W A S H

IN

G T O N ,D C

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D

A

B

C

W A S H

IN

G T O N

FIRE PROTECTION

N4008018C0033

C D

W F

IN

A

L S

U B

M

II

S S

IO

N

/0

/2

S U

B M

IS

S

IO

N

/0

/2

FOR OFFICIAL USE ONLY

S U

B M

IS

S

IO

N

/1

/2

P R

E -F

IN

A

L S

U B

M

IS

S

IO

N /0

/2

F

IN

A L

/1

/2

As indicated

7/ 9/

:3

5:

P M

A101

B

LD

G

6/

FI

R S

T

FL

O O

R P

LA

N

CheckerAuthorDesigner

2 8 16 32 1/16" = 1'-0"A101

1 FIRST FLOOR PLAN

N

KEYNOTE LEGEND

# KEYNOTE

1 NEW STAIR AND LANDING, SEE STAIR DRAWINGS

2 GENERATOR DOCKING STATION ON CONCRETE PAD,

SEE ELECTRICAL DRAWINGS

3 6" STL/CONCRETE BOLLARD, 36" HIGH, SEE 2/A506

4 FIRE DEPARTMENT CONNECTION, SEE CIVIL AND FIRE

PROTECTION DWGS.

5 COOLING TOWER ON CONCRETE PAD, SEE MECHANICAL

DRAWINGS

6 CONCRETE RAMP TO RAISED FLOOR ELEVATION

7 REMOVABLE RAIL AT LANDING, SEE NOTES ON 9/A705

13129148

USP-003: CONSTRUCTION OF FOUR (4)

NEW DOOR OPENINGS AND 175 LINEAR

FEET OF INTERIOR PARTITIONS IS

EXCLUDED

DN

UP

A

B

C

D

F

G

H

J

K

A432

A303

A303

A303

A301

A302

A302

8 9 10 11 12 13 14 15 16 1711.7

E

14.7

A302

15.213.712.710.79.78.7

OFFICE

OFFICE

CORRIDOR

RR

ART

OPEN

OFFICE

P6A

RARE

BOOK

ROOM

REFERENCE

STAFF

OFFICES

CORRIDOR

S1-1

STAIR

UA

CURATION

UA LAB

UA

CHEM

STORAGE 121

UA

ENTRANCE

UA

DIVE

LOCKER

UA

MACRO

ELEV

MACH

LOADING

DOCK

RECEPTION

ART

SHOP

UA

FIELD

EQUIP

CONFERENCE

E-1

ELEV

OFFICE

MICROFORM

BREAK

COMM

MAIN

ENTRY

VESTIBULE

STOR.

WOMEN'S

MEN'S

JAN

126A

OHD-1144B 101A144A

E-S1

125B

125A

150A

101B

123A

147 148

EL-1

123B

144C

P3.3

P2.4P2.4

P2.4

P2.4

P2.4

P1A

P2.4

P1A.1

P3.3 P3.3

P8A

P1A

P1A

P1A.1

P1A

P1A

P1A

P3.3

P3.3 P3.3

P1A

P1B

P1A

P1A P1A

P1B P1A

P6B

M2.1

P1A

P1A.1

A711

A701

A721

A722

/1 A401B

/1 A401B

P8A

P8A

P8A P5

P5

P5 6' - 4 1/8"

1' - 1 7/16"

/4

0' - 10"8' - 0"11' - 1 3/8"

/8

7'

0"

/8

0' - 8 9/16"

19' - 7 1/2" 0' - 6 1/2"

0' - 6" 11' - 10 7/8" 6' - 11 1/8" 6' - 8" 5' - 2 7/8"5

3' - 8 7/8" 5

N-128

M3.1

UA

CURATION

STORAGE127

STORAGE

127B

ELEC

CLOSET

8' - 6"

P1A.1

7' - 0" 4' - 7 1/2"

A503

TYP

A503

TYP

A511

TYP

A511

TYP

P1A.1 P1A.1

P1A

P1BP5

P1A

P1A

P6B

P8A

P6A

P6A

P4A

P4A

M2.1

P1A.1P1A

P1A

P4A

P6B

P5

+0.500

+0.000

+0.500

+0.000

+0.500

10' - 6 1/16"8' - 3 7/16"

/2

/8

/8

/4

/8

P2.4

/2

10' - 9 1/8"

2' - 0"

2' - 0 1/2"

7' - 0" 0' - 10"

1' - 4 1/2"

7' - 10 1/8" 3' - 2 7/8"1' - 0 7/8"

P4A

M1B.1

M1B.1

17' - 8 7/8"0' - 5 1/8"

/8

/8

19' - 8 11/16"

1' - 7 3/4"

P6B

6' - 9 9/16" 3' - 4"

P5

P5

A734

A751

OFFICE

127B

126B

W-127

29' - 8"

P1A/MTL-2

P1A/MTL-2

1 1

9 14

13 13 13 13 13

2' - 3" 2' - 3"

5' - 6"

CLEARANCE FOR

MOTOR ABOVE

FENCE, ADJUST

FENCE IF NEEDED

12' - 3 3/8"

/8

10' - 2 1/2"

5' - 3 1/2" 9' - 9 1/2"

/4

4' - 4 1/8"

/2

/2

9' - 11 1/2"

A511

TYP

P4A

A511

TYP

A511

TYP

A511

TYP

M1/MTL-2

2' - 10 5/8"

1/4"

135.00°

135.00°

4' - 7 3/8" 10' - 4 3/4"

6 3/4" 3' - 6"

4' - 0"

3' - 6 1/8"

5' - 0"

/2

6 1/4"

P4A

P4A

P4A

P2.4

P1A

P4A

P1A.1

P1A

P1A

KEY PLAN

Beyer Blinder Belle Architects and Planners, LLP 3307 M Street NW, Suite 301 Washington, DC 20007 202 333 8000

W N

Y

-6

O

P E

R A

T

IO

N A

L A

R C

H

IV

E S

A N

D

R E

S E

A R

C H

R E

P O

S

IT

O R

Y

N O

D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

W A S H

IN

G T O N D C

W A S H

IN

G T O N

N A V Y

Y A R D

D

D E P A R T M E N T

O F

T H E

N A V Y

SHEET

A

B

C

1 2 3 4 5

1 2 3 4 5

OF

NAVFAC DRAWING NO.

CONST. CONTR. NO.

EPROJECT NO.:

SCALE:

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

W

A S

H

IN

G T

O N

W A S H

IN

G T O N ,D C

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D

A

B

C

W A S H

IN

G T O N

FIRE PROTECTION

N4008018C0033

C D

W F

IN

A

L S

U B

M

II

S S

IO

N

/0

/2

S U

B M

IS

S

IO

N

/0

/2

FOR OFFICIAL USE ONLY

S U

B M

IS

S

IO

N

/1

/2

P R

E -F

IN

A

L S

U B

M

IS

S

IO

N /0

/2

F

IN

A L

/1

/2

As indicated

7/ 9/

:3

6:

P M

A401A

1S T

FL

O

O R

E

N

LA

R G

E D

P

LA

N N

O R

TH

CheckerAuthorDesigner

N

1 4 8 16 1/8" = 1'-0"A401A

1 BLDG 46/67 - 1ST FLOOR NORTH

STEP AT CONNECTION

TO UA FIELD EQUIP

KEYNOTE LEGEND

# KEYNOTE

1 FIRE EXTINGUISHER CABINET, SEE <FE-1> ON A641

2 HI-LO WATER FOUNTAIN, F-6, SEE PLUMBING DWGS

3 EMERGENCY EYE WASH, SEE PLUMBING DWGS

4 SINK, SEE PLUMBING DWGS

5 WALK-OFF MAT, SEE <FG-1> ON A641. INCLUDE 3/8"

DEPRESSION IN TOPPING SLAB.

6 FIRE DEPARTMENT CONNECTION, SEE CIVIL AND

FIRE PROTECTION DWGS.

7 MILLWORK, SEE A731 AND A732.

8 AIR CIRCULATION UNIT, TYP. SEE MECH DWGS.

9 HD STORAGE, FULL DRAWINGS TO BE SUBMITTED IN

SEPARATE STORAGE PACKAGE. SEE DETAILS 1 AND

2/A504 FOR RAIL DETAILS.

10 LADDER, SEE <LD-1> ON A641.

11 EXTERIOR LADDER, SEE <LD-2> ON A641.

12 RAILING, SEE <RL-3> ON A641

13 EXISTING DOWNSPOUTS AND COLLECTORS TO BE

REPLACED IN KIND, TYP.

14 FLOOR DRAIN, TYP. SEE PLUMBING DWGS

15 BUILDING DIRECTORY

16 PHOTO IMAGE FEATURE WALL, DESIGN TO BE

APPROVED BY OWNER

17 NEW DOWNSPOUT FOR ENTRY CANOPY

18 CORNER GUARD, TYP FOR ALL OUTSIDE CORNERS

ON GYPSUM WALLS OF OCCUPIED SPACES. SEE

<CG-1> ON A641 FOR ADDITIONAL INFORMATION.

19 6" STL/CONCRETE BOLLARD, 36" HIGH, SEE 2/A506

20 EXISTING STAIR. VERIFY CONDITIONS IN FIELD AND

REPLACE AS NEEDED FOR CODE COMPLIANCE.

21 EXISTING OPENING INFILL. SIM TO 1/A511, ALIGN

SCHEDULED PARTITION WITH EXISTING WALL TO

RECEIVE ADJACENT WALL.

13129160

UP

UP

UP

A

B

C

D

F

G

H

A303

A303

A303

A301

1 2 3 4 5 6 7 8

E

S-113

E-114

S-112

1S2B

1S2A

150B

STACKS

146145

HEAD

OFFICE 146

OFFICE

CORRIDOR

S2-1

STAIR

VEST

FIRE

PUMP 114

ELEC

COMM

ART

STORAGE

ART

OPEN

OFFICE

P3.3

P8A

M2.3

P5

P8A

P1A.1

P5 P5

P1A

P6A

P5

114B

WATER

SERVICE

A701

P3.3

15' - 6 3/4" 48' - 9 5/16" 13' - 5 9/16"

7.76.7

S-136

/1 A402A

/1 A401A

114C P1A.1

A702

A702

P3.3

A501

A503

TYP

A503

TYP

A503

TYP

A511

TYP

A511

TYP

+0.000

+0.500

+0.000

+0.500

+0.000

+0.500

P1A

P1A

P5

P3.3

17' - 7 1/8" 11' - 10 7/8"

P1A

/2 "4

/2

/4

/8

P6B

P5

/4

P2.4

P1A

R A

M P

D N

A703

A703

P3.3

P4A

4' - 3"

/2

4' - 3"

/2

6' - 3 1/2" 5' - 0"

5 1/8"

5 5

2' - 3"

2' - 3"

1' - 0"

P4A

4" TOPPING + 2"

INSULATION

A511

TYP

A511

TYPM1.1

M2.1

7' - 9 5/8"

4 3/8" 6' - 2" 11' - 10" 11' - 6"

3' - 7"

/8

3' - 7"

/8

5' - 3 1/4"

/4

5' - 1 5/8"

/4

ALIGN

A L

IG

N

/4

P4A

5' - 9 1/8"

P4A

P4A

P4A

P5

P4A

KEY PLAN

Beyer Blinder Belle Architects and Planners, LLP 3307 M Street NW, Suite 301 Washington, DC 20007 202 333 8000

W N

Y

-6

O

P E

R A

T

IO

N A

L A

R C

H

IV

E S

A N

D

R E

S E

A R

C H

R E

P O

S

IT

O R

Y

N O

D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

W A S H

IN

G T O N D C

W A S H

IN

G T O N

N A V Y

Y A R D

D

D E P A R T M E N T

O F

T H E

N A V Y

SHEET

A

B

C

1 2 3 4 5

1 2 3 4 5

OF

NAVFAC DRAWING NO.

CONST. CONTR. NO.

EPROJECT NO.:

SCALE:

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

W

A S

H

IN

G T

O N

W A S H

IN

G T O N ,D C

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D

A

B

C

W A S H

IN

G T O N

FIRE PROTECTION

N4008018C0033

C D

W F

IN

A

L S

U B

M

II

S S

IO

N

/0

/2

S U

B M

IS

S

IO

N

/0

/2

FOR OFFICIAL USE ONLY

S U

B M

IS

S

IO

N

/1

/2

P R

E -F

IN

A

L S

U B

M

IS

S

IO

N /0

/2

F

IN

A L

/1

/2

As indicated

7/ 9/

:3

6:

P M

A401B

1S T

FL

O

O R

E

N

LA

R G

E D

P

LA

N S

O U

TH

CheckerAuthorDesigner

1 4 8 16 1/8" = 1'-0"A401B

1 BLDG 46/67 - 1ST FLOOR SOUTH

N

KEYNOTE LEGEND

# KEYNOTE

1 FIRE EXTINGUISHER CABINET, SEE <FE-1> ON A641

2 AIR CIRCULATION UNIT, TYP. SEE MECH DWGS.

3 HD STORAGE, FULL DRAWINGS TO BE SUBMITTED IN

SEPARATE STORAGE PACKAGE. SEE DETAILS 1 AND

2/A504 FOR RAIL DETAILS.

4 FIRE DEPARTMENT CONNECTION, SEE CIVIL AND

FIRE PROTECTION DWGS.

5 EXISTING DOWNSPOUTS AND COLLECTORS TO BE

REPLACED IN KIND, TYP.

6 EXTERIOR LADDER, SEE <LD-2> ON A641.

7 CORNER GUARD, TYP FOR ALL OUTSIDE CORNERS

ON GYPSUM WALLS OF OCCUPIED SPACES. SEE

<CG-1> ON A641 FOR ADDITIONAL INFORMATION.

8 6" STL/CONCRETE BOLLARD, 36" HIGH, SEE 2/A506

9 GENERATOR DOCKING STATION ON CONCRETE

PAD, SEE ELECTRICAL DRAWINGS

10 EXISTING OPENING INFILL. SIM TO 1/A511, ALIGN

SCHEDULED PARTITION WITH EXISTING WALL TO

RECEIVE ADJACENT WALL.

13129161

FIRST FLOOR

0' - 6"

SECOND FLOOR

14' - 6"

46 EAVE HEIGHT

31' - 10"

EXISTING

0' - 0"

46 B.O. TRUSS

30' - 9"

A301

A301

A302

A302

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

11.7 14.7

E-101 E-103.5

E-116

E-216E-201 E-202 E-203 E-203.5 E-204 E-205 E-206 E-206.5 E-207 E-209 E-210 E-211 E-211.5 E-212 E-213 E-213.5 E-214 E-215

E-102 E-104 E-106 E-106.5 E-107 E-108 E-109 E-110 E-111 E-111.5 E-112 E-113 E-113.5

E-114

15.213.712.710.79.78.77.76.7

E-103

A627

E-108.5

5 5

A703

5 A703

A703

A702

3' - 0"

23 23 23

23 23 23

23 23

FIRST FLOOR

0' - 6"

SECOND FLOOR

14' - 6"

46 EAVE HEIGHT

31' - 10"

EXISTING

0' - 0"

67 EAVE HEIGHT

27' - 6"

46 B.O. TRUSS

30' - 9"

67 B.O. TRUSS

23' - 3"

A301

A301

A302

A302

1234567891011121314151617

11.714.7

W-216

W-116 W-114

W-011

W-110.5

W-106

W-101

W-001

W-201

W-102W-103W-103.5W-104W-105W-107W-108

W-207W-208W-208.5W-209W-210W-210.5 W-215

W-115

W-202W-203W-203.5W-204W-205W-206W-214 W-213.5

W-113.5

W-213

W-002W-003W-003.5W-004W-005

W-009W-009.5W-010W-010.5

W-108.5W-109W-110

W-127

15.2 13.7 12.7 10.7 9.7 8.7 7.7 6.7

WINDOWS NOT

IN SCOPE

W-112.5 W-112 W-111.5

11 6

6 6

4 4

4' - 0"

3' - 5"

23 23

23 23 23

FIRST FLOOR

0' - 6"

SECOND FLOOR

14' - 6"

46 EAVE HEIGHT

31' - 10"

ABC

DF

G

H

J

K

EXISTING

0' - 0"

67 EAVE HEIGHT

27' - 6"

46 B.O. TRUSS

30' - 9"

67 B.O. TRUSS

23' - 3"

A303

A303

A303

E

S-2C

S-1C

S-2B.5

S-3B.5

S-1F

S-2B

S-1B

S-1G

S-112

S-B101S-B103 S-B104

S-B102

S-251

A302

BUILDING 67 BUILDING 46

S-113

A627

S-136

A702

" 6' - 0"

22 22

2' - 0"

FIRST FLOOR

0' - 6"

SECOND FLOOR

14' - 6"

46 EAVE HEIGHT

31' - 10"

A B C

D F

G

H

J

K

EXISTING

0' - 0"

67 EAVE HEIGHT

27' - 6"

46 B.O. TRUSS

30' - 9"

67 B.O. TRUSS

23' - 3"

A303

A303

A303

E

N-2B.5

N-3B.5

N-2B

N-1B N-1F

N-2C

N-1C

N-2F N-2G N-2J

N-1JN-1G

BUILDING 67BUILDING 46

A302

9 17

4 4

A752

3' - 0"

23 23

23 23 23

GENERAL ELEVATION NOTES:

1. PATCH AND REPAIR ALL EXTERIOR WINDOW FRAMES,

SASHES AND SILLS. REPAIR ANY DEFICIENCIES IN THE

THE WOOD AND REPLACE ANY MISSING GLASS OR

WINDOW PARTS AS NECESSARY TO MATCH EXISTING.

2. PATCH AND REPAIR EXISTING MASONRY WALLS AS

NEEDED.

3. EXISTING GUTTERS, COLLECTORS, AND DOWN

SPOUTS ARE TO BE REPLICATED AND REPLACED IN

PLACE.

4. REPLACE ALL EXTERIOR DOORS IN KIND OR AS

NOTED IN DOOR SCHEDULE AND DETAILS.

5. REPLACE ALL LADDERS WITH NEW STEEL LADDER

AND PROVIDE STEEL PLATE DOOR WITH PIANO HINGE

AND HASP.

6. CONTRACTOR TO VERIFY ALL CONDITIONS AND

DIMENSIONS IN FIELD.

Beyer Blinder Belle Architects and Planners, LLP 3307 M Street NW, Suite 301 Washington, DC 20007 202 333 8000

W N

Y

-6

O

P E

R A

T

IO

N A

L A

R C

H

IV

E S

A N

D

R E

S E

A R

C H

R E

P O

S

IT

O R

Y

N O

D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

W A S H

IN

G T O N D C

W A S H

IN

G T O N

N A V Y

Y A R D

D

D E P A R T M E N T

O F

T H E

N A V Y

SHEET

A

B

C

1 2 3 4 5

1 2 3 4 5

OF

NAVFAC DRAWING NO.

CONST. CONTR. NO.

EPROJECT NO.:

SCALE:

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

W

A S

H

IN

G T

O N

W A S H

IN

G T O N ,D C

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D

A

B

C

W A S H

IN

G T O N

FIRE PROTECTION

N4008018C0033

C D

W F

IN

A

L S

U B

M

II

S S

IO

N

/0

/2

S U

B M

IS

S

IO

N

/0

/2

FOR OFFICIAL USE ONLY

S U

B M

IS

S

IO

N

/1

/2

P R

E -F

IN

A

L S

U B

M

IS

S

IO

N /0

/2

F

IN

A L

/1

/2

As indicated

7/ 9/

:3

6:

P M

A201

B

LD

G

6/

E

LE

V

A

TI

O N

S

CheckerAuthorDesigner

2 8 16 32 1/16" = 1'-0"A201

1 EAST

2 8 16 32 1/16" = 1'-0"A201

2 WEST

2 8 16 32 1/16" = 1'-0"A201

3 SOUTH

2 8 16 32 1/16" = 1'-0"A201

4 NORTH

KEYNOTE LEGEND

# KEYNOTE

1 EXISTING DOWNSPOUTS AND COLLECTORS TO BE

REPLACED IN KIND, TYP.

2 <RF-1>, SLATE ROOFING

3 EXISTING COPPER GUTTERS TO BE REPLACED IN

KIND, TYP

4 EXISTING BRICK WALL, TYP

5 NEW STAIR AND LANDING, SEE STAIR DRAWINGS

6 NEW LOUVER WITHIN EXISTING WINDOW, SEE

WINDOW SCHEDULE

7 EXISTING WINDOW TO REMAIN, TYP

8 FIRE DEPARTMENT CONNECTION, SEE FIRE

PROTECTION AND CIVIL DRAWINGS

9 CONCRETE RAMP TO RAISED FLOOR ELEVATION

10 <RF-2A> ROOF ASSEMBLY, SEE DETAILS

11 NEW LOUVER, SEE MECHANICAL DRAWINGS

12 CONNECTION TO BUILDING 108, NIC

13 REMOVE BRICK INFILL AND RECREATE HISTORIC

APPEARANCE OF OCULUS WINDOW

14 <RF-2B> ROOF ASSEMBLY, SEE DETAILS

15 EXTERIOR LADDER, SEE <LD-2> ON A641.

16 STOREFRONT WINDOW/DOOR ASSEMBLY BEYOND

17 REPLACE INFILL AT EXISTING DOOR OPENING

18 EXISTING BRICK CORNICE AND CORBELING

19 RAILING, SEE <RL-1> ON A641

20 EXISTING CORRUGATED METAL PANEL WALL TO

REMAIN

21 REFURBISH AND SECURE ALL STEEL EXTERIOR

ACCESS DOORS TO THE EXISTING

BASEMENT/CRAWL SPACES

22 6" STL/CONCRETE BOLLARD, 36" HIGH, SEE 2/A506

23 EXTERIOR LIGHTING, SEE ELECTRICAL DRAWINGS.

CENTER BETWEEN WINDOWS U.N.O. ELEVATION TO

BE 10' ABOVE FIRST FLOOR ELEVATION U.N.O.

24 COOLING TOWER ON CONCRETE PAD, SEE

MECHANICAL DRAWINGS

25 GENERATOR DOCKING STATION ON CONCRETE

PAD, SEE ELECTRICAL DRAWINGS

13129156

Bldg 46_67 Final Vol 2 Drawing Final 2020 07 10_WITH MARKUPS 1
Bldg 46_67 Final Vol 2 Drawing Final 2020 07 10_WITH MARKUPS 50
Bldg 46_67 Final Vol 2 Drawing Final 2020 07 10_WITH MARKUPS 62
Bldg 46_67 Final Vol 2 Drawing Final 2020 07 10_WITH MARKUPS 63
Bldg 46_67 Final Vol 2 Drawing Final 2020 07 10_WITH MARKUPS 58

File details come from the government source that posted it. Updated .