AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to answ er a technical question clarif ing the Performance Specification numbering. See pages 2 through
7. In accordance w ith Amendment 0004, electronic quote submission is allow ed.
The required response date/time has changed from 10-Mar-2017 04:00 PM to 13-Mar-2017 04:00 PM.
Due to a numbering error on FBO Amendment 0004 w as posted as Amendment 0003 and Amendment 0005 w ill be posted as Amendment 0004.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 7
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 10-Mar-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N00164-17-T-0065
X 9B. DATED (SEE ITEM 11)
31-Jan-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
10-Mar-2017
CODE
NAVAL SURFACE WARFARE CENTER CRANE DIV
C. LANE (812-854-2737)
BLDG 3373
300 HWY 361
CRANE IN 47522-5001
N00164 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N00164-17-T-0065
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SECTION 4.0 - CLAUSES & OTHER FULL TEXT INFORMATION
SUMMARY OF CHANGES
SECTION 1.0 - SCHEDULE/INSPECTION & ACCEPTANCE/DELIVERY
The required response date/time has changed from 10-Mar-2017 04:00 PM to 13-Mar-2017 04:00 PM.
The following have been added by full text:
AMENDMENT 0005
Question:
Page 9+10 of the 73 page solicitation has a table referring to Table I: Qualification, where are 3.3.1 thru 3.3.15 referenced from?
Answer:
In developing this solicitation, the system automatically renumbered the Performance Specification within the document. As a result, the Performance Specification references in the Statement of Work Section 2.4 Table I:
Qualification no longer matched the correct Performance Specification paragraphs. The Performance Specification has been renumbered to clarify the Government’s requirement.
PERFORMANCE SPECIFICATION
06 January 2017 Crane Division, Naval Surface Warfare Center (NSWC Crane)
Code JXMP, BLDG 3287E
300 HWY 361
Crane, IN 47522-5001
Performance Specification N00164-17-R-JM09:
Requirements for AC/DC Converter for Dismounted Accessory Kit
1.0 SCOPE
1.1 Purpose
This performance specification describes the requirements of an AC/DC Converter to be used in an I1B1 Dismounted Accessory Kit.
2.0 APPLICABLE DOCUMENTS
The following documents will be used as guidelines to the extent specified herein.
2.1 Government Documents
GOVERNMENT SPECIFICATIONS and STANDARDS
MILITARY
MIL-STD-130 IDENTIFICATION MARKING OF U.S. MILITARY PROPERTY
MIL-STD-461F REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC
INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND
EQUIPMENT
MIL-STD-810F ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND
LABORATORY TESTS
MIL-DTL-38999L CONNECTORS, ELECTRICAL, CIRCULAR, MINIATURE, HIGH
DENSITY, QUICK DISCONNECT (BAYONET, THREADED OR BREECH
COUPLING), ENVIRONMENTAL RESISTANT WITH CRIMP
REMOVABLE CONTACTS OR HERMETICALLY SEALED WITH FIXED,
SOLDERABLE CONTACTS, GENERAL SPECIFICATIONS FOR
MIL-DTL-53022D PRIMER, EPOXY COATING, CORROSION INHIBITING LEAD AND
CHROMATE FREE
MIL-DTL-53039E COATING, ALIPHATIC POLYURETHANE, SINGLE COMPONENT,
CHEMICAL AGENT RESISTANT
MIL-DTL-64159B CAMOUFLAGE COATING, WATER DISPERSIBLE ALIPHATIC
POLYURETHANE, CHEMICAL AGENT RESISTANT
MIL-STD-464C ELECTROMAGNETIC ENVIRONMENTAL EFFECTS REQUIREMENTS
FOR SYSTEMS
MIL-D-50030H DECONTAMINATING AGENT, DS2
MIL-DTL-12468E DECONTAMINATING AGENT, STB
MIL-STD-202G TEST METHOD STANDARD ELECTRONIC AND ELECTRICAL
COMPONENT PARTS
FEDERAL
FED-STD-595 COLORS USED IN GOVERNMENT PROCUREMENT
2.2 Precedence of Documents
In the event of a conflict between this specification and the applicable documents, this specification takes precedence.
3.0 REQUIREMENTS
3.1 Electrical
The 22VDC, 300 Watt AC/DC Converter will provide conditioned voltages as defined herein for utilization in a dismounted application. Refer to Table I for key electrical characteristics.
Table I: Electrical Characteristics INPUT VOLTAGE: 120VAC/240VAC, 40 – 70 Hz
OUTPUT VOLTAGE: +22 VDC 1/
OUTPUT POWER: 300 W
REGULATION: +3/-10% 2/
POWER FACTOR: 0.9 Minimum 1/
OUTPUT RIPPLE: <1% 1/ 3/
OUTPUT NOISE: <1% 1/ 3/
TEMPERATURE (OPERATIONAL): -20o to +55oC TEMPERATURE (NON-OPERATIONAL): -40o to +75oC 1/ Characteristics to be tested at 25oC ± 3oC with a 300W load, unless otherwise specified 2/ Regulation to be tested across full voltage input range, load to vary from 10-100% up to a 2000Hz rate, and across all operational temperatures 3/ Ripple + noise shall be ≤ 2% pk-pk for loads between 10-80%.
3.1.1 Power On/Off
The AC/DC Converter shall incorporate an On/Off power switch.
3.1.2 System Protection
The system shall be protected against short circuit, over-voltage (25V Max) and over-temperature. If the input voltage level does not remain within normal voltage range, the AC/DC Converter shall shut down and/or gracefully degrade the output voltage. The system shall automatically return to operational condition upon restoration of power.
3.1.3 External Interface
The AC/DC Converter external interconnect is defined in Table II and Table III.
Table II: J1 Input Power Connector Pinout Definition
PIN 120VAC – SERVICE 240VAC - SERVICE
A X – 120V_HOT X – 120V_HOT_01
B N/C N/C
C W – 120V_NEUTRAL Y – 120V_HOT_02
D G – SAFETY_GND G – SAFETY GND
E N/C N/C F N/C N/C
Table III: J2 Output Power Connector Pinout Definition
PIN SIGNAL NAME
B +22VDC
D +22VDC_RTN
C N/C E N/C
A, F N/C
3.2 Mechanical
3.2.1 Physical
3.2.1.1 Weight
The weight of the AC/DC Converter shall not exceed 10 pounds.
3.2.1.2 Size
The outside dimensions of the AC/DC Converter shall not exceed 6.13” x 16.00” x 3.00”, including connectors.
3.2.2 Connectors
The Input/Output connectors for the AC/DC Converter shall be IAW MIL-DTL-38999 as follows:
J1 – D38999/20WB98PN
J2 – D38999/24WE6SA
3.2.3 Paint
Prime with MIL-DTL-53022, Type IV, epoxy primer. Paint with MIL-DTL-53039 type III or MIL- DTL-64159 type II, chemical agent resistive coating, polyurethane, tan 686A color number 33446 per
FED-STD-595.
3.2.4 Markings
At a minimum, the connectors’ reference designators and the On/Off switch positions shall be labeled IAW MIL-STD-130. Markings shall use white ink AA56032-IIIWHT, on a black background AA56032IIIBLK. Character height shall be .12 minimum.
3.2.5 Part Identification
Mark part IAW MIL-STD-130 with the following information. Character height shall be .08 minimum.
Manufacturer CAGE Code shall be applied.
53711SOCNC8664652-1
XXXXXSOCNXXXXXXXXX-X [SUPPLIER PIN OPTIONAL]
MFR – XXXXX [APPLICABLE CAGE CODE]
3.3 Environmental
3.3.1 Electromagnetic Emissions and Susceptibility
The unit shall be designed to comply with MIL-STD-461F, for electromagnetic interference characteristics at “Navy Ground” levels and requirements. All tests will be performed at 120VAC input into a 300W load, unless otherwise specified.
RS101 – Radiated Susceptibility, Magnetic Field, 30 Hz to 100 kHz, Figure RS101-1.
RS103 – Radiated Susceptibility, Electric Field, 2 MHz to 40 GHz, 10 V/m (2 MHz to 1 GHz) 50 V/m (1 GHz to 40 GHz) RE102 – Radiated Emissions, 10 kHz to 18 GHz, Figure RE102-4 CS101 – Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz, Curve #1 CS114 – Conducted Susceptibility, Bulk Cable Injection, 10 kHz to 200 MHz, Curve #2 CS115 – Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation CS116 – Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz.
CE102 – Conducted Emissions, Power Leads, 10 kHz to 10 MHz, for both 120 VAC input (6 dB curve) and 240VAC input (9 dB curve)
3.3.2 Electromagnetic Environmental Effects
The unit shall be designed to comply with MIL-STD-464C for electromagnetic effects.
3.3.3 Resistance to Solvents
Because the entire system must be capable of being operated and maintained in a Nuclear-Biological- Chemical (NBC) environment, the unit shall be constructed to survive decontamination procedures using existing capabilities. Exposed materials shall be selected to resist degradation when exposed to decontaminants DS2, per MIL-D-50030, and STB, per MIL-DTL-12468E.
3.3.4 Fungal Growth
None of the materials used shall include fungal nutrient material.
3.3.5 Operating Temperature
The unit shall be designed and constructed to survive and operate from:
1. Operating -20oC to +55oC
a. Max temperature, steady state, as defined in MIL-STD-810F, Method 501.4, Procedure II (category Hot/Dry)
b. Min Temperature, steady state, as defined in MIL-STD-810F, Method 502.4, Procedure II (category Low)
2. Storage -40oC to +75oC
3.3.6 Thermal Shock
The unit shall be designed and constructed to survive and operate during thermal shock, per MIL-STD- 202G, Method 107, Test Condition A.
3.3.7 Altitude
The unit shall be designed and constructed to survive and operate at altitude (Low Pressure) IAW conditions defined in MIL-STD-810F, Method 500.4, Procedure I (Storage/Air Transport) and Procedure II (Operation/Air Carriage). Operating altitude is 15,000 feet.
3.3.8 Humidity
The unit shall be designed and constructed to survive and operate during humid conditions as defined by MIL-STD-810F, Method 507.4, and MIL-STD-202G, Method 103, Test Condition A.
3.3.9 Rain and Blowing Rain
The unit shall be designed and constructed to survive and operate in rain and blowing rain conditions as defined by MIL-STD-810F, Method 506.4, Procedure I. Must be resistant to both salt and fresh water.
3.3.10 Icing/Freezing Rain
The unit shall be designed and constructed to survive and operate in icing/freezing rain conditions as defined by MIL-STD-810F, Method 521.2.
3.3.11 Sand and Dust
The unit shall be designed and constructed to survive and operate during sand and dust conditions as defined by MIL-STD-810F, Method 510.4, Procedure I (Blowing Dust) and Procedure II (Blowing Sand), and per MIL-STD-202G, Method 110.
3.3.12 Salt Fog
The unit shall be designed and constructed to survive and operate during salt fog conditions as defined by MIL-STD-810F, Method 509.4, and Salt Spray (Corrosion) per MIL-STD-202G, Method 101, Test Condition A.
3.3.13 Explosive Atmosphere
The unit shall be designed and constructed to survive and operate in an explosive atmosphere as defined by MIL-STD-810F, Method 511.4.
3.3.14 Vibration
The unit shall be designed and constructed to survive and operate under vibration as defined by MIL- STD-202G, Method 201. Mounting method shall be approved by the Procuring Activity prior to commencement of testing.
3.3.15 Shock
The unit shall be designed and constructed to survive and operate under shock as defined by MIL- STD-202G, Method 213, Test Condition J. Mounting method shall be approved by the Procuring Activity prior to commencement of testing.
3.4 Workmanship
The unit shall be processed in such a manner as to be uniform in quality and shall be free from defects that affect life, serviceability, or appearance.
3.5 Change of qualified product
The supplier shall not initiate major changes, which affect form, fit, or function, including quality, reliability, and interchangeability, from those processes, materials, and procedures used to qualify the items without notifying the Procuring Activity in writing.
4.0 NOTES
4.1 Technical Point of Contact
4.1.1 Technical Project Lead
Mr. Timothy Woodward (812) 854-2559, FAX (812) 854-1174, E-Mail:
timothy.a.woodward@navy.mil
The following have been deleted:
PERFORMANCE SPECIFICATION
(End of Summary of Changes)