This document is Amendment 14 to Solicitation N0010423RK067 for Shielded Mild Detonating Cords. The amendment answers contractor questions and makes the following key changes:
The closing date for offers is extended to September 24, 2024 at 2:00 PM Eastern Time. The contracting office and point of contact have been updated to NAVSUP Weapon Systems Support and Ashley Leonard, respectively. The amendment addresses several technical exceptions taken by the contractor regarding requirements such as ID plates, paint colors, o-rings, and threaded fittings, stating that the contractor must submit a document change request to comply with the solicitation drawing. It also addresses exceptions related to booster cup requirements, detonating cord testing, and fire test assembly methods, indicating that some exceptions are acceptable while others will require revised test procedures. The amendment confirms that first article testing may be waived at time of award, though pricing must be provided with FAT included.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 3.04_Amendment15_N0010423RK067.pdf | ||
| 3.04_Amendment(13)_N0010423RK067.pdf | ||
| N0010423RK067 0011.pdf | ||
| N0010423RK067 0010.pdf | ||
| 3.04_Amendment(8)_N0010423RK067.pdf | ||
| 3.04_Amendment(9)_N0010423RK067.pdf | ||
| 3.06_Amendment(8)_23RK067 - Vendor Exceptions IH response v2_N0010423RK067.xlsx | XLSX spreadsheet | |
| 3.04_Amendment(7)_N0010423RK067.pdf | ||
| 23RK067 Amendment 6.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N0010423NB056
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
1. Contractor submitted questions are answ ered in Section B on this amendment.
2. NAVSUP Contact information is revised to read Ashley Leonard.
3. Closing date for offers is extended to 24 September 2024 at 02:00 PM Eastern Time.
1. CONTRACT ID CODE PAGE OF PAGES
1 8
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 13-Aug-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N0010423RK067
X 9B. DATED (SEE ITEM 11)
13-Sep-2023
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
13-Aug-2024
CODE
NAVSUP WEAPON SYSTEMS SUPPORT
ASHLEY LEONARD, CODE N772.09
5450 CARLISLE PIKE SUITE 410
MECHANICSBURG PA 17050-2411
N00104 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N0010423RK067
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 28-Aug-2024 02:00 PM to 24-Sep-2024 02:00 PM.
The Issued By organization below has been deleted:
NAVSUP WEAPON SYSTEMS SUPPORT
5450 CARLISLE PIKE
P.O. BOX 2020
MECHANICSBURG PA 17050-2411
The 'issued by' organization has changed from
NAVSUP WEAPON SYSTEMS SUPPORT
ANDREW WATSON CODE N772.10
5450 CARLISLE PIKE SUITE 410
MECHANICSBURG PA 17050-2411
to
NAVSUP WEAPON SYSTEMS SUPPORT
ASHLEY LEONARD, CODE N772.09
5450 CARLISLE PIKE SUITE 410
MECHANICSBURG PA 17050-2411
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
CONTRACTOR Q AND A
Solicitation Q&A Amendment 8:
Question: Note 26 ID Plate: a different color plate meeting a different MIL‐SPEC is used is this acceptable?
Answer: No the contractor will be required to submit a document change notice for the affected drawing to comply with drawing 857AS400 REV L as identified in the solicitation.
Question: Note 27 SMDC Line Paint: a different color meeting a different MIL‐SPEC is used is this acceptable?
Answer: No the contractor will be required to submit a document change notice for the affected drawing to comply with drawing 857AS400 REV L as identified in the solicitation.
Question: Note 28 O‐Ring: A washer and a seal are used instead of a Parker O‐Ring is this acceptable?
Answer: No the contractor will be required to submit a document change notice for the affected drawing to comply with drawing 857AS400 REV L as identified in the solicitation.
Question: Note 31 Threaded Fitting: an anodized threaded fitting meeting a different MIL‐SPEC is currently used.
These fittings do not have a PTFE coating. Will this be acceptable?
Answer: No the contractor will be required to submit a document change notice for the affected drawing to comply with drawing 857AS400 REV L as identified in the solicitation.
Question: The contractor has been in production of this item in the past 12 months can first article testing be waived on this requirement?
Answer: Waiver of first article will be determined at time of award but all offerors shall submit pricing in accordance with the FAT requirements of the solicitation providing unit price with FAT included. A price may also be submitted with FAT waived but this optional.
Q&A Amendment 8:
Booster Cup Requirement: The booster shall(0023) contain 1+/- .1 grain of HNS pressed to 32,000 +/- 1,000 psi.
Validation/Compliance: Booster cup load of 1 ±.1 grain does not met contractors established (12/1969) Booster cup load. [1 ±.1 grain is 64.8± 6.5 mg, Collins booster cup is 67±7 mg]. Appears in spec rounding to one digit in the requirement and possible rounding in actual grain to mg factor.
Exception/Question: The contractor takes exception and asks to use the booster cup as is. Contractors booster cup load is standard load size for all SMDC, FCDC, ECRL and TLX. Changing load originally qualified in 1969 could effect .285-inch dimension from face of booster cup to ferrule flang on Contractors top assembly drawing and Navy drawing 841AS425 (redesign and qualification).
IH response: Acceptable for all offerors.
Detonating Cord Sample Temp Hour Requirement Requirement: The 9 inch segments of the detonating cord sample shall(0068) be temperature conditioned for not less than 8 hours nor greater than 24 hours, one segment each at -65° ± 5°F and +350° ± 5°F.
Validation/Compliance: Testing Per the ATP is only 4 hours.
Exception/Question: Contractor takes exception to the 8 hour requirement listed as the current process IAW the ATP is 4 hours.
IH Response: Acceptable for all offerors.
Electrical Blasting Cap Requirement: Following temperature conditioning, each segment shall(0069) be fired by a commercial no. 6 electrical blasting cap and the detonation velocity measured to determine conformance to the requirements of 3.4.1.
Validation/Compliance: Contractor does not use electrical blasting cap no. 6 but uses no. 8.
Exception/Question: Contractor takes exception to the requirement as the new test setup does not use electrical blasting caps.
IH Response: Contractors must provide a copy of the latest LAT set up and ATP.
Firing of Test Specimen Requirement: The test specimen shall(0086) be fired in the manner depicted on NAVAIR drawing No. 841AS800.
Validation/Compliance: Partially compliant.
Exception/Question: Modified LAT setup.
IH Response: Contractors must provide a copy of the latest LAT set up and ATP.
Aluminum Foil Type Identification Plate Requirement: THE ALUMINUM FOIL-TYPE IDENTIFICATION PLATE SHALL BE IN ACCORDANCE WITH MIL-
DTL-19834, TYPE I.
Validation/Compliance: Contractors nameplate does not comply with MIL‐DTL‐19834.
Exception/Question: Take exception to the MIL-DTL-19834 specification. Contractors nameplate is qualified for F-18
SMDC.
IH Response: Acceptable for all offerors.
Specification for Shielded Mild Detonating Cord Test Tip Requirement: THE ALUMINUM FOIL-TYPE IDENTIFICATION PLATE SHALL BE IN ACCORDANCE WITH MIL-
DTL-19834, TYPE I.
Validation/Compliance: Stating this is now an invalid requirement due to new set up.
Exception/Question: Take exception to the MIL-DTL-19834 specification. Contractors nameplate is qualified for F-18
SMDC.
IH Response: Contractor will be required to submit an RFV.
Fitting Nut Thread Size Torque Requirement: FITTING NUT .688 thread size .4375-20 UNF torque (inch pounds) 80-100 Validation/Compliance: Over torque for aluminum fitting nuts Exception/Question: Take Exception to requirement. Over torque for aluminum fitting nuts. Max torque is 90 in-lbs.
MIL-DTL-32154, Para. 3.9.1 only requires 90 in-lbs test.
IH Response: Approved proposed torque range is within specification.
Fitting Nut Thread Size Torque Requirement: FITTING NUT .750 thread size .5000-20 UNF torque (inch pounds) 100-120 Validation/Compliance: Over torque for aluminum fitting nuts Exception/Question: Take Exception to requirement. Over torque for aluminum fitting nuts. Max torque is 90 in-lbs.
MIL-DTL-32154, Para. 3.9.1 only requires 90 in-lbs test IH Response: NOT APPROVED. Proposed torque range is not in accordance with the spec requirement.
Fire Test Assembly Requirement1: FIRE TEST ASSEMBLY BY TAPING A COMMERCIAL NO.6 ELECTRIC BLASTING CAP TO THE APPLICABLE SMDC TEST TIP INSTALLED IN TIE TEE CONNECTOR AND APPLY A FIRING CURRENT OF
5.00±.25 AMPS TO THE BLASTING CAP LEAD WIRES FROM A24-28 VDC SOURCE.
Requirement2: THE OUTPUT END OF THE BLASTING CAP SHALL BE IN INTIMATE CONTACT AND LONGITUDINALLY ALIGNED WITH THE EXPLOSIVE CORE OF THE DETONATING CORD PROTRUDING FROM
THE SMDC TEST TIP.
Requirement3: ALTERNATE THE DONOR SMDC TEST TIP BETWEEN FIRINGS SUCH THAT AN APPROXIMATELY EQUAL NUMBER OF FIRINGS IS PERFORMED AT EACH CONDITIONING TEMPERATURE, BY DETONATING THE SMDC TEST TIP IN-LINE WITH THE SMDC TEST SPECIMEN AND BY DETONATING THE
SMDC TEST TIP AT 90' WITH THE SMDC TEST SPECIMEN.
Validation/Compliance: Stating this is now an invalid requirement due to new set up.
Exception/Question: For safety Blasting caps no longer used, SMDC test tips replaced by HE TLX Test Tips with same 1 grain output as SMDC test tip. HE TLX Test Tip initiation is performed using a percussion primer.
IH Response: RFV will be required.
SMDC Lot Acceptance Test Specimen Requirement: STANDARD SMDC LOT ACCEPTANCE TEST SPECIMEN SHALL BE IN ACCORDANCE WITH
NAVAIR DWG 841AS425, SHEET 9.
Validation/Compliance: Stating this is now an invalid requirement.
Exception/Question: Sheet 9 on Dwg 841AS425AJ is a list of where used for the customer SMDC. Assumption is it should be Sheet 3 of 841AS425AJ. Contractor is compliant to Sheet 3 of 841AS425J.
IH Response: Agreed.
Sensitivity Test Requirement: SENSITIVITY TEST FITTING DRAWING Validation/Compliance: Stating this is now an invalid requirement.
Exception/Question: Contractor will use Sensitivity Test Fitting Drawing # 80017. Sensitivity Test Fitting 80017 qualified to Boeing 74B80225 SMDCs equivalent to the Navy 841ASA425 SMDCs. Collins Sensitivity Test Fitting complies with Navy Drawing 841AS801A IH Response: Drawing must be provided to validate for any offeror.
Connector Tee Requirement: CONNECTOR TEE DRAWING Validation/Compliance: Stating this is now an invalid requirement.
Exception/Question: Collins will use Standard SMDC configuration Connector Tee, PN 21738-2. Tee PN 21738-2 compliant to all dimensions shown on 841AS802, except additional design rounds bottom face to a full radius and some corners to .25 radius.
IH Response: Contractor must provide a copy of DWG PN 21738‐2 to validate concurrence
Dent Block Holder Requirement: C SMDC DENT BLOCK HOLDER DRAWING Validation/Compliance: Stating this is now an invalid requirement.
Exception/Question: Customer design is an old design not used by Contractor. The contractor will use Dent Block Holder Drawing # 80397. Dent Block Holder 80397 qualified to Boeing 74B80225 SMDCs equivalent to the Navy 841ASA425 SMDCs. Contractors holder does not require a threaded port for the SMDC.
IH Response: The contractor must provide a copy of DWG PN 80397. How to secure the booster tip against to the dent block?
Sensitivity Fitting Holder Requirement: SENSITIVITY FITTING HOLDER DRAWING Validation/Compliance: Stating this is now an invalid requirement.
Exception/Question: Customer design does not hold sensitivity fitting in and can allow sensitivity fitting halves to move apart changing internal volume. The contractor will use Sensitivity Holder, TN 12800-1, which is designed to capture and keep sensitivity fittings from coming apart.
IH Response: The contractor will need to provide more information.
Q&A Amendment 13:
1. Question: MIL-D-21625G Section 4.8.4 states "In the design verification test program there shall be no interim withdrawals. In the service release test program six cartridges each shall be removed at 0800 on the third and fourth Monday." For the first article, are we following the design verification test program or the service release test program?
Answer: The Design Verification test program for no interim withdrawals should be followed.
2. Question: MIL-D-21625G Section 4.8.6 states "Sealed in cartridge actuated actuated devices shall be subjected to the salt fog test for 168 hours. Cartridges installed in cartridge actuated devices will be subjected to a 168 hour salt fog test when the cartridge actuated devices are tested in accordance with MIL- D-23615." For the first article, are we doing the salt fog test for 48 hours or 168 hours?
Answer: For FAT the contractor should perform a 48 hours of exposure followed by 48 hours of drying.
They can also increase the number of cycles to provide a higher degree of confidence but I’m not sure if that’s related to the 168 hours mentioned in the MIL-D-21625G spec.
3. Question: MIL-D-21625G Section 4.8.5 states "The minimum acceleration power spectral density (Wo) for cartridges mounted in the cockpit of jet aircraft shall be 0.10 g2/Hz shall be approved by the cognizant design agency." Can you confirm the vibration spectrum for this part?
Answer: Vibration Spectrum should be 0.1 g2/Hz minimum with an Frequency between 5-85 Hz. See picture below. This spectrum profile only applies for cockpit zone.
4. Question: For the shock test, how many shock pulses in each axis?
The following have been modified:
SECTION B NOTES
SOLICITATION NOTES:
1. Faxed offers will NOT be accepted.
2. Because the Government intends to award without discussion, any exceptions to the requirements of this solicitation should be raised prior to submission of an offer.
3. This item is a CSI – Critical Safety Item.
4. Electronic submission of an offer may be accomplished by attaching your offer to an email directed to ashley.l.leonard4.civ@us.navy.mil. The size limitation of an email through the NAVSUP WSS mail server is 10 MB. All files designated as .zip files will be stripped from any email sent. Files larger than the server limitation may be segregated and sent via several emails as long as they are clearly identified as such. It is highly recommended that the Offeror request email delivery confirmation or other form of acknowledgement to verify that the proposal submission was received.
(End of Summary of Changes)