MSRB 202509600 Technical Exhibits.pdf
PDF 2 MB Posted
- Attached to
- AD Proj #202509600 Mass State Retirement Board Boston, within a 1. 25 mile radius of 1 Ashburton Pl
- Solicitation number
- BD-27-1019-DCP06-OOL01-132058
- Issued by
- Massachusetts
About this file
Technical Exhibits for Massachusetts State Retirement Board Leasing Project
This document contains technical exhibits and design standards for a leasing project by the Massachusetts Department of Capital Asset Management and Maintenance (DCAMM) on behalf of the Massachusetts State Retirement Board (MSRB). The project seeks approximately 10,400 square feet of usable office and client service space in Boston within a 1.25-mile radius of One Ashburton Place, with consideration for spaces ranging from 9,400 to 11,400 square feet. The technical exhibits provide detailed specifications and standards for various space types and finishes, including reception transaction counters with tempered glass, wellness rooms, staff support spaces, office and huddle rooms, and conference rooms of varying sizes (small, medium, large, and divisible multi-function rooms). The exhibits include comprehensive architectural drawings with floor plans, elevations, and sections showing furniture layouts, electrical and data outlet locations, audiovisual (AV) coordination requirements, and interior signage standards. The contract term is specified as ten years.
The technical exhibits function as design and construction reference documents for the contractor, establishing baseline standards for space configuration, materials, and finishes while noting that the contractor remains responsible for meeting all applicable building codes, including ADA compliance. Key specifications include electrical outlets at 18 inches above finished floor for standard duplex and quad outlets, data outlets with two per location, dimmable lighting in wellness spaces, resilient and carpet flooring options, stainless steel deal trays for reception counters, and specific signage requirements using Aptos font with raised copy and Braille. The exhibits explicitly state that plans are for reference only and that certain elements—such as final AV layouts, furniture selections, water cooler placement preferences, and window configurations—require coordination and validation with the user agency during the design phase. All documents are dated between October 2025 and March 2026, indicating recent preparation for the leasing solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MSRB 202509600 Estoppel Certificate.pdf | ||
| MSRB 202509600 RNDA.pdf | ||
| MSRB 202509600 Warning.pdf | ||
| MSRB 202509600 SNDA.pdf | ||
| MSRB 202509600 SAFS.pdf | ||
| MSRB 202509600 RFP.pdf | ||
| MSRB 202509600 Ten-Year Lease Proposal Form.docx | DOCX document | |
| MSRB 202509600 10-year Office Lease.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5' -0
10" X 12" STAINLESS STEEL DEAL TRAY PROVIDED BY
CONTRACTOR
2' -2
2.5" GROMMET IN WORKSURFACE FOR ELECTRIC AND
DATA CORDS. WIRES TO FEED INTO CABLE TRAY.
COUNTER NOT TO PROJECT MORE THAN 4" FROM THE
WALL. AGENCY TO VALIDATE IF 12" REQUIRED AS A
WRITING SURFACE
1' -8
B
5'-0" CLEARANCE REQUIRED IN FRONT OF RECEPTION
COUNTER FOR PRIVACY
7'-0"
SOFFIT ABOVE WORKSURFACE WITH RECESSED CAN
LIGHTS
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER
LOCATION. 18" AFF UNLESS NOTED
SYMBOL KEY
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED. OUTLET TO BE ALWAYS ON
A
REVIEW STORAGE
WITH USER AGENCY
CEILING HEIGHT VARIES
STAINLESS STEEL DEAL TRAY
PROVIDED BY CONTRACTOR
(12"X10")
SUPPORTS AS
NEEDED
TEMPERED GLASS
" M
AX
T
O P
O F
TR
AN
SA
C
TI
O
N C
O U
N
TE
R
2' -5
2 MINIMUM RECESSED CAN
LIGHTS OVER WORKSURFACE
WIRE MGMT2'
-1
0"
TEMPERED GLASS
DEAL TRAY
COUNTER SUPPORTS AS
NEEDED
8"
1" DIA. X 2" CYLINDRICAL
BRUSHED ALUMINUM GLASS
HOLDER
1" DIA. X 2" CYLINDRICAL
BRUSHED ALUMINUM GLASS
HOLDER
PLASTIC LAMINATE
COUNTERS ON 34" PLYWOOD
SUBSTRATE. LAMINATE ON
ALL EXPOSED SURFACES
WIRE MANAGEMENT TRAY
2 MINIMUM RECESSED CAN
LIGHTS OVER
WORKSURFACE
WALL TO UNDERSIDE OF
DECK1'-0"
CEILING HEIGHT PER
PROJECT SPECIFICATIONS
5/8" GWB OVER METAL
STUDS
2 14" EDGE BAND TO
ACOMODATE DEAL TRAY.
GROMMETS
5/8" GWB OVER METAL
STUDS BOTH SIDE OF WALL
TECHNICAL EXHIBIT #2.1
PLAN
SCALE AS NOTED
DATE 01/28/ 2026
CREATED BY: BRK
CHECKED BY: KM
TYPICAL RECEPTION
TRANSACTION COUNTER - TEMPERED GLASS
ELEVATION A
PLAN SCALE 1/4" = 1'-0"
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
NOTES
1. REVIEW STORAGE WITH
USER AGENCY
2. WIDTH OF WINDOW TO BE
ADJUSTED IF MORE THAN 2
RECEPTIONISTS REQUIRED
SCALE 1/2" = 1'-0" SECTION B SCALE 1/2" = 1'-0"
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 0224 2026.dwg, 2/25/2026 5:22:33 PM
TECHNICAL EXHIBIT# 4
I
1" X 4" SOLID STAIN GRADE
WOOD CHAIR RAIL.
,,,- WOOD BLOCKING
4" STRAIGHT WALL BASE
FOR CARPET
4" COVE BASE FOR
RESILIENT FLOORING
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE
II TYPICAL CHAIR RAIL DETAIL
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design•DrawirigsWVortdng\lEASING EXHIBITS_UPDATE 2026.dwg, 3.13/2026 11:19:16 AM
SCALE 1"= 1'-0"
DA TE 03/02/ 2026
CREATED BY: BRK
CHECKED BY:
42 AFF
MINUMUM
TABLE
1'-6"
CLEAR
RESILIENT
FLOORING
CARPET
2'
-1 0"
8'-0"
REFRIGERATOR
NIC
34" MINIMUM WIDTH AND
24" MINIMUM HEIGHT
CLEARANCE. 17" KNEE
SPACE MINIMUM.
3' -6
S
EC
TI
O
N A
1' -6
2' -3
2' -1
0"
1'-5"
9"
REMOVABLE
PANEL
ROOMS WITH PLUMBING: KITCHEN / WELLNESS
DUPLEX ELECTRICAL
OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER
OUTLETS PER
LOCATION
WELLNESS ROOM NOTES
· FURNITURE SHOWN TO BE PROVIDED BY TENANT
· LIGHTS TO BE DIMMABLE
· FLOORING AT SINK TO BE RESILIENT FLOORING
· IF SIDE LIGHT PROVIDED ENTIRE WINDOW TO BE
PRIVACY FILM
· MIRROR & BULLETIN BOARD NOT PROVIDED BY
CONTRACTOR
WELLNESS ROOM
TECHNICAL EXHIBIT #13
PLAN TYPICAL 80 SQ FT
SCALE 1/2" =1'-0"
SCALE 1/4" = 1'-0"
SCALE as noted
DATE 10/07/2025
CREATED BY: BK
CHECKED BY : CB and EA
SINK SECTION SCALE 1/2" = 1'-0"
ELEVATION OF MILLWORK WELLNESS ROOM
EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/7/2025 3:17:15 PM
AutoCAD SHX Text
REF
2' -1
0"3' -6
1' -6
2'-0" 1'-6"3'-0"
1' -3
2'
-6
3'-0"
24" MINIMUM HEIGHT
CLEARANCE. 17" KNEE
SPACE MINIMUM.
S
EC
TI
O
N A
1'-6"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER LOCATION
H20
MARKER BOARD AND/OR
TACK BOARD TBD
8' -0
"C H
C H
C
H 07C
H
42"
AFF
42"
AFF
QUENCH WATER COOLER
AND WALL PHONE TBD
A
MARKER BOARD AND
TACK BOARD ALIGN
BOTTOM
WITH COUNTER
30 x 60
30 x 60
30 x 60
A
42"
AFF
42"
AFF
H20
WALL PHONE TBD
QUENCH WATER COOLER
2' -3
2' -1
0"
1'-5"
9"
REMOVABLE
PANEL
SCALE AS NOTED
DATE 06/06/2025
CREATED BY: BRK
CHECKED BY: CB
STAFF SUPPORT
TECHNICAL EXHIBIT #14
ELEVATION A OF MILLWORK STAFF SUPPORT ROOM
PLAN KEY
SCALE 1/2" =1'-0"
SCALE 1/4" =1'-0"TYPICAL PLAN 200 SQ FT STAFF SUPPORT SPACE
SCALE 1/4" =1'-0"TYPICAL PLAN 400 SQ FT STAFF SUPPORT SPACE
NOTES
PLANS SHOW PREFERRED OPTION FOR QUENCH WATER COOLERS BY MOST AGENCIES . VALIDATE
LOCATION WITH AGENCY. SOME AGENCIES PREFER COUNTER TOP OPTIONS WHEN SPACE PERMITS
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE
SINK SECTION A SCALE 1/2" = 1'-0"
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 6/3/2025 5:06:37 PM
REFRIGERATOR NIC
WALL WITH SIDELIGHT WALL AND SIDELIGHTWALL WITH NO SIDELIGHT
SIGNAGE - INSTALLATION FOR PERMANENT IDENTIFICATION OF WALLED SPACES (WALL/GLASS) MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISH FLOOR (AFF) MEASURED TO THE BASELINE OF THE RAISED TEXT.
· THE ABOVE RECOMMENDED PLACEMENT IS INTENDED TO MEET THE SIGN LOCATION REQUIREMENTS OF THE 2010 ADA
STANDARDS. SEC.703.4.1
· SIGN ALIGNMENT TO BE MOUNTED ON SURFACE ADJACENT TO THE LATCH SIDE OF THE DOOR, WITHIN 2" - 4" FROM THE
DOOR TRIM.
Conference
Conference
Conference
PLACE SIGN ON SIDELIGHT PLACE SIGN ON WALL PLACE SIGN ON WALL
SIGN 2" - 4" FROM FRAME
5' -4
1' -1
0"
1'-4"
ROOM ID SIGNAGEGLAZING FILM
1/4" TEMPERED GLAZING
1'-6"
R
AI
SE
D
T
EX
T
" A
FF
R
AI
SE
D
T
EX
T
" A
FF
R
AI
SE
D
T
EX
T
" A
FF
SIGN 2" - 4" FROM FRAME SIGN 2" - 4" FROM FRAME
1'-4"
1'-6"
1' -1
0" 3'
-6
3' -6
INTERIOR SIGNAGE STANDARDS
NOTE BACKERS REQUIRED WHEN MOUNTED ON GLASS. BACKER COLOR TO BE CONFIRMED BY AGENCY.
CONTRACTOR RESPONSIBLE TO MEET ADA COMPLIANCE ON ALL SIGNS. INCLUDING INSTALLATION.
ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE AND DRAWINGS ABOVE. INSERT TEXT TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS. ALL SIGNS TO BE POSTED BY CONTRACTOR. ADDITIONAL MATERIAL AND PRINTING INSTRUCTIONS TO BE SUPPLIED TO AGENCY FOR FUTURE SIGNS.
SIGNS CAN BE PURCHASED THROUGH TAKEFORM STYLE VIVID (TAKEFORM.NET). ORDERS AND QUESTIONS CAN BE PLACED BY EMAILING MIKE R. HUNGERFORD 1.800.528.1398 MRH@TAKEFORM.NET. FINAL SIGNAGE OPTIONS AND
SIGNS TO BE SUBMITTED TO DCAMM PROJECT MANGER FOR APPROVAL.
TAKEFORM ROOM SIGNS ARE TYPE J.3B VVAW-01001105-R9DO1. TAKEFORM COLROS DARK BLUE PMS 539C OR SILVER
CMYK 8,9,5,35
TAKEFORM WORKSATION SIGNS ARE TYPE L.b VV1AW-01000701-R9D01
THIS IS FOR INTERNAL AGENCY SPACE ONLY. THESE SIGNS ARE NOT APPLICABLE FOR BATHROOM OR BUILDING CORE
SIGNS
GLAZING FILM: 3M CRYSTAL, DUSTED (7725SE-314) OR EQUAL
· GLAZING FILM TO BE INSTALLED ON THE ROOM SIDE OF THE GLAZING USING MANUFACTURER APPROVED
PRODUCTS AND INSTALLATION INSTRUCTIONS. GLASS DOORS TO HAVE MATCHING FILM
· A MANUFACTURER APPROVED SIGNAGE BACKER SHALL BE MOUNTED ON THE ROOM SIDE OF THE GLAZING
DIRECTLY BEHIND THE ROOM ID SIGNAGE. THE BACKER SHALL BE SIMILAR SIZE TO THE ROOM ID SIGNAGE SO THAT IT FULLY COVER THE BACK OF THE SIGNAGE. IF GLAZING FILM IS SPECIFIED, THE SIGNAGE BACKER
SHALL BE MOUNTED ON TOP OF THE GLAZING FILM.
Conference
TYPICAL WORKSTATION SIGNS
5"W X 3.5"H WITH INSERT
MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER
DEPENDING ON WORKSTATIONS SPECIFIED
TYPICAL OFFICE SIGNS
CONFERENCE, OFFICES, FOCUS ROOMS, PHONE ROOMS, HUDDLE ROOMS
5"W X 5.5"H WITH INSERT
MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER
DEPENDING ON WORKSTATIONS SPECIFIED.
ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE. INSERT TEXT
TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS.
W5209.05
GRAPHIC PRINTED ON INSERT
WINDOW SIZE 4.5W X 2.5 H
OPTIONS FOR BACKGROUND
PMS 539C DARK BLUE
OR SILVER
OPTIONS FOR BACKGROUND
PMS 539C DARK BLUE
OR SILVER
GRAPHIC PRINTED ON INSERT
WINDOW SIZE 4.5W X 2.5 H
TECHNICAL EXHIBIT #15
SIGNAGE FOR LEASING PROJECTS
SCALE AS NOTED
DATE 06/06/ 2025
CREATED BY: BK
CHECKED BY: AB
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
DETAILS SCALE 6" = 1'-0"
ELEVATIONS SCALE 1/8" = 1'-0"
NOTES
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 2/12/2026 10:24:32 AM
CH-O
10'-0"
'-0
TB
D
8W
30x72
6' -0
" C H
-O
10'-0"
'-0
TBD 48W
30x72
6' -0
4' -0
4' -0
MINIMUM 9'-0"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
QUAD ELECTRICAL OUTLET 18" AFF
UNLESS NOTED. OUTLETS TO BE ALWAYS
ON.
DATA OUTLETS. 2 PER OUTLETS
PER LOCATION
10'-0"
'-0
TABLE
36x72
3'-0" MIN.
5' -0
CH-O
10'-0"
5' -0
'-0
TB
D
8W
30x72
5' -0
5' -0
MONITORS ON ARMS
OR MOUNTED TO WALL
WITH HDMI FOR
MONITOR CONNECTED
TO DOCKING STATION
ON TABLE
TYPICAL OFFICE 100 SQ FT
SCALE 1/4" = 1'- 0"
DATE 10/07/ 2025
CREATED BY: BRK
CHECKED BY: JW
TYPICAL OFFICE AND HUDDLE ROOMS
TECHNICAL EXHIBIT #17
TYPICAL OFFICE 120 SQ FT TYPICAL FLEX OFFICE OR HUDDLE 120 SQ FT
NOTES
· OUTLETS SHOWN ARE TO BE ALWAYS ON.
· SWITCHED OUTLETS TO BE CLEARLY NOTED
· MONITOR ARMS ARE SELECTED BY USER
AGENCY.
EXHIBITS ARE FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE TO MEET
APPLICABLE CODES INCLUDING ADA COMPLIANCE
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/16/2025 4:21:22 PM
6 PERSON 190 SQ FT
4 PERSON 120 SQ FT 5 PERSON 140 SQ FT
'-0
42x72
48 x 96
PIN
TO
W
ALL
PIN
TO
W
ALL
FLOOR CORE LOCATION STO BE
COORDINATED WITH TABLE
FLOOR CORE
LOCATIONS
TO BE
COORDINATED
WITH TABLE
' M
IN
IM
U M
NOTES
· MINIMUM 36" CIRCULATION AROUND TABLES.
42" IS IDEAL
· FURNITURE PM TO COORDINATE WITH AV
CONTRACTOR FOR TABLE SIZE, ELECTRICAL
IN FURNITURE LOCATION, WIRE MANAGEMENT
AND GROMMET PLACEMENT.
· MINIMAL OUTLETS FOR AV ON PLAN.
ADDITIONAL OUTLETS REQUIRED BY CODE TO
BE COORDINATED BY ARCHITECT
· 54" WIDTH MIN. TABLE REQUIRED WITH 2
MONITORS
· OPTION WHEN TABLE IS AGAINST WALL TO
HAVE MONITORS MOUNTED ON TABLE USING
MONITOR ARMS.
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
36x72
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION 4'-0"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED. OUTLET TO BE
ALWASYS ON
DATA OUTLETS. 2 PER OUTLETS PER
LOCATION
FLOOR CORE OUTLETS. SIZE AND
CONFIGURATION TO BE BASED ON NEEDS;
ELECTRICAL, DATA AND AV COORDINATION
REQUIRED
KEY
4'-0"
GROMMET FOR SPEAKER. FURNITURE PM
TO COORDINATE WITH AV CONTRACTOR
MONITOR MOUNTED TO WALL
OR USE MONITOR ARMS TBD
WIRE MANAGEMENT TRAY FURNITURE PM
TO COORDINATE WITH AV CONTRACTOR
SCALE 1/4" = 1'-0"
DATE 02/11/ 2026
CREATED BY: BRK
REVIEWED BY: KM
SMALL CONFERENCE AV DESIGN
DISCLAIMER:
THIS EXHIBIT IS FOR PLANNING AND SAMPLE PURPOSES ONLY AND
DOES NOT ESTABLISH SPECIFIC REQUIREMENTS. REQUESTS FOR
ADDITIONAL OR DETAILED SPECIFICATIONS SHALL BE DIRECTED TO
DCAMM PROJECT MANAGER DURING DESIGN PHASE.
CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
TECHNICAL EXHIBIT #21
ROOM 8 Person 200 SQ FT 14 PERSON 250 SQ FT
'-0
16'-6"
10 Person 216 SQ FT
'-0
18'-0"
PIN
TO
W
ALL
PIN
TO
W
ALL
PIN
TO
W
ALL
54 x 120
TABLE 10' X 4'-6"
FLOOR CORE
LOCATIONS
TO BE
COORDINATED
WITH TABLE
MINIMUM 3'-7"
FOR PIN TO
WALL
FLOOR CORE LOCATIONS
TO BE COORDINATED
WITH TABLE
FLOOR CORE
LOCATIONS
TO BE COORDINATED
WITH TABLE
' M
IN
IM
U M
-1 2'
P R
EF
ER
ED
WIRE MANAGEMENT
TAG
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
MINIMUM 3'-7"
FOR PIN TO
WALL
'-0
WIRE MANAGEMENT
4' x 15'
MEDIUM CONFERENCE ROOM NOTES
· MONITOR HEIGHTS ARE ALL NOTED FOR PIN
TO WALL UNITS THAT ARE 18"AFF. IF WALL
MOUNTED UNITS ARE USED OUTLET HEIGHT
TO BE COORDINATED WITH AV CONTRACTOR.
AVH DOCUMENT RECOMMENDS 58'AFF AS A
GENERAL COMMENT.
NOTES
· MINIMUM 36" CIRCULATION AROUND TABLES.
42" IS IDEAL
· FURNITURE PM TO COORDINATE WITH AV
CONTRACTOR FOR TABLE SIZE, ELECTRICAL
IN FURNITURE LOCATION, WIRE MANAGEMENT
AND GROMMET PLACEMENT.
· MINIMAL OUTLETS FOR AV ON PLAN.
ADDITIONAL OUTLETS REQUIRED BY CODE TO
BE COORDINATED BY ARCHITECT
· 54" WIDTH MIN. TABLE REQUIRED WITH 2
MONITORS
· OPTION WHEN TABLE IS AGAINST WALL TO
HAVE MONITORS MOUNTED ON TABLE USING
MONITOR ARMS.
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED. OUTLET TO BE
ALWASYS ON
DATA OUTLETS. 2 PER OUTLETS PER
LOCATION
FLOOR CORE OUTLETS. SIZE AND
CONFIGURATION TO BE BASED ON NEEDS;
ELECTRICAL, DATA AND AV COORDINATION
REQUIRED
KEY
GROMMET FOR SPEAKER. FURNITURE PM
TO COORDINATE WITH AV CONTRACTOR
WIRE MANAGEMENT TRAY FURNITURE PM
TO COORDINATE WITH AV CONTRACTOR
SCALE: 1/4" = 1'- 0"
DATE 02/11/ 2026
CREATED BY: BK
REVIEWED BY: SENT
TYPICAL MEDIUM CONFERENCE ROOM AV DESIGN
DISCLAIMER:
THIS EXHIBIT IS FOR PLANNING AND SAMPLE PURPOSES ONLY AND
DOES NOT ESTABLISH SPECIFIC REQUIREMENTS. REQUESTS FOR
ADDITIONAL OR DETAILED SPECIFICATIONS SHALL BE DIRECTED TO
DCAMM PROJECT MANAGER DURING DESIGN PHASE.
CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
TECHNICAL EXHIBIT #22
AutoCAD SHX Text 48x96
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
4'-0"
20 PERSON 314 SQ FT
LARGE OVER 300 SQ FT
x
TA
BL
E
' X
FLOOR CORE
LOCATION
TO BE COORDINATED
WITH TABLE
30 PERSON CONFERENCE OR
BOARD ROOM LAYOUT 500 SQ FT
18 PERSON TRAINING
LAYOUT 500 SQ FT
MONITOR MONITOR
AV CART
MONITOR MONITOR
M O
N
ITO
R M
O N
ITO
R
MONITOR MONITOR
LARGE, X-LARGE, TRAINING AND DIVISIBLE
CONFERENCE ROOM NOTES
· AV COORDINATION REQUIRED FOR
STRUCTURAL SUPPORT, DATA, ELECTRIC
AND AV EQUIPMENT PRIOR TO
CONSTRUCTION. BLOCKING FOR AV
EQUIPMENT TO BE INCLUDED.
· COORDINATE LOCATION AND DETAILS OF
OUTLETS WITH AV EQUIPMENT SELECTION
· EQUIPMENT TO BE COORDINATED WITH AV
CONTRACTOR. NOTE MINIMUM OF 1"
DIAMETER GROMMET FOR MICROPHONE
REQUIRED. AV CONTRACTOR IS
RESPONSIBLE TO SUPPLY FURNITURE PM
WITH INFORMATION REGARDING GROMMETS,
POWER, OR AV EQUIPMENT TO BE MOUNTED
OR CUT INTO FURNITURE.
· PRESENTATION POINT TO BE COORDINATED
WITH FURNITURE LAYOUT. AV CONTRACTOR
TO WORK WITH FURNITURE PM .
· AV CONTRACTOR TO VALIDATE IF FURNITURE
IS REQUIRED TO SUPPORT ANY AV
EQUIPMENT. SPECIFICATIONS ARE
REQUIRED BY AV CONTRACTOR REGARDING
SIZE AND ANY AIR CIRCULATION
REQUIREMENTS.
· CONFIRM ADDITIONAL DATA AND ELECTRIC
SHOWN ON PLAN FOR TRAINING WITH
AGENCY
M O
N
ITO
R M
O N
ITO
R
AV CONTRACTOR TO PROVIDE LAYOUTS
AND SCREEN LOCATION. NOTE HEIGHT OF
OUTLET TO BE VERIFIED BY AV CONTRACTOR
AV CONTRACTOR TO RECOMMEND LAYOUTS
AND SCREEN LOCATION
OPTIONAL 3 ROOMS
EACH ROOM 500 SQ FT
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
DASHED LINE
SHOWS MINIMUM
OF 42" FOR
CIRCULATION
OUTLETS 58" AFF OUTLETS 58" AFF
MONITOR
OUTLETS
58" AFF
OUTLETS
58" AFF
OUTLETS
58" AFF
O U
TLETS
58" AFF
MONITOR
OUTLETS
58" AFF
DIVISIBLE SPACE /MULTI FUNCTION ROOM
58" AFF
NOTES
· MINIMUM 42" CIRCULATION AROUND TABLES.
· FURNITURE PM TO COORDINATE WITH AV
CONTRACTOR FOR TABLE SIZE, ELECTRICAL
IN FURNITURE LOCATION, WIRE MANAGEMENT
AND GROMMET PLACEMENT.
· MINIMAL OUTLETS FOR AV ON PLAN TO BE
ALWAYS ON. ADDITIONAL OUTLETS
REQUIRED BY CODE TO BE COORDINATED BY
ARCHITECT
· 54" WIDTH MIN. TABLE REQUIRED WITH 2
MONITORS
· OPTION WHEN TABLE IS AGAINST WALL TO
HAVE MONITORS MOUNTED ON TABLE USING
MONITOR ARMS.
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED. OUTLET TO BE
ALWASYS ON
DATA OUTLETS. 2 PER OUTLETS PER
LOCATION
FLOOR CORE OUTLETS. SIZE AND
CONFIGURATION TO BE BASED ON NEEDS;
ELECTRICAL, DATA AND AV COORDINATION
REQUIRED
KEY
GROMMET FOR SPEAKER. FURNITURE PM
TO COORDINATE WITH AV CONTRACTOR
WIRE MANAGEMENT TRAY FURNITURE PM
TO COORDINATE WITH AV CONTRACTOR
TECHNICAL EXHIBIT #23
SCALE :1/8"= 1'-0"
DATE 02/24/ 2026
CREATED BY: BK
CHECKED BY: KM
TYPICAL LARGE CONFERENCE,TRAINING ROOMS, DIVISIBLE SPACE/MULTI FUNCTION ROOMS AV DESIGN
DISCLAIMER:
THIS EXHIBIT IS FOR PLANNING AND SAMPLE PURPOSES ONLY AND
DOES NOT ESTABLISH SPECIFIC REQUIREMENTS. REQUESTS FOR
ADDITIONAL OR DETAILED SPECIFICATIONS SHALL BE DIRECTED TO
DCAMM PROJECT MANAGER DURING DESIGN PHASE.
CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 0224 2026.dwg, 2/24/2026 5:25:34 PM
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
3'-6"
| Technical Exhibit 2.1 Typical Reception Transaction Counter (Tempered Glass) (2) |
| Sheets and Views |
| TE2.1 reception Transaction |
| Technical Exhibit 4 Typical Chair Rail Detail (2) |
| Technical Exhibit 13 Wellness Room (5) |
| Sheets and Views |
| WELLNESS TE13 |
| Technical Exhibit 14 Staff Support] (3) |
| Sheets and Views |
| STAFF SUP. TE 14 |
| Technical Exhibit 15 Signage (8) |
| Sheets and Views |
| TE15 Signage |
| Technical Exhibit 16 Phone and Focus (2) |
| Technical Exhibit 17 Typical Office and Huddle (3) |
| Sheets and Views |
| OFFICE HUDDLE TE17 |
| Technical Exhibit 21 SMALL CONFERENCE ROOM AV DESIGN (3) |
| Sheets and Views |
| LEASING EXHIBITS_UPDATE 2026-TE21 SMALL CONFERENCE |
| Technical Exhibit 22 MEDIUM CONFERENCE ROOM AV DESIGN (4) |
| Sheets and Views |
| LEASING EXHIBITS_UPDATE 2026-TE22 MEDIUM CONFERENCE |
| Technical Exhibit 23 LARGE CONFERENCE Training Divisible Space MultiFunction Rooms AV DESIGN0224 2026 (4) |
| Sheets and Views |
| TE 23 multi purpose |
File details come from the government source that posted it. Updated .