This document is a Response Form for a Mobile Oxygen Storage Tank (MOST) detailing comprehensive technical specifications and performance requirements. The form outlines key performance parameters and system attributes for a medical-grade oxygen storage and delivery system, with specific requirements including storage capacity of 10,000 liters of gaseous oxygen at 2250 psi, operational capability to support a 24-hour mission using 7 or fewer MOST containers, and weight less than 250 pounds. Critical technical specifications include container size (40 in x 30 in x 16 in), transportability requirements, operator interface components, operational temperatures ranging from -40°F to 140°F, and additional features such as three 20-foot oxygen delivery hoses, adjustable oxygen flow regulators (0-15 LPM), and ballistic/fragmentation resistance testing. The document also specifies long-term requirements like 15-year service life, hydrostatic testing every 5 years, 95-98% operational availability, and support for parts and repairs for 7-8 years from the last system sold.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 20251020_MOST_RFI.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Response Form #2
# Detailed Requirement Description Priority Threshold (T)*
(Minimum)
Objective (O)**
(Desired) Comments Meets (Y/N) Vendor Comments
1 Store and dispense gaseous medical grade oxygen KPP USP 93% ±3% T=O
2 FDA and DOT status KPP Approved T=O
3 Safe-to-Fly status KPP Approved T=O MOST will be labeled as "Hazardous Cargo" during flight
# Detailed Requirement Description Priority Threshold (T)*
(Minimum)
Objective (O)**
(Desired) Comments Meets (Y/N) Vendor Comments
Storage capacity
10,000 Liters of gaseous oxygen @2250 psi T=O
Operational capability
Seven (7) MOST containers to meet 24-hour mission.
Less than or equal to 6 MOST containers to meet
24-hour mission
68,956 liters of gaseous oxygen in 24-hour period
3 Weight Less than 250 lbs Less than 200 lbs
Container Size
40 in x 30 in x 16 in
(11 cubic feet) T=O
Transportability
a. Man-portable: able to be carried and wheeled IAW
MIL-STD 1472
b. Container designed to prevent damage to the system during operation and transport (air & ground)
c. Transportable via container wheels for multiple surface types
T=O
Operator Interface/Panel Components
a. Content pressure gauges
b. Gaseous liters indicator
c. Easily readable in low-light environments
d. Night vision goggle compatible
T=O
Alarms
a. Visual and audible
b. Indicate low tank level T=O
8 Operating temperatures Temp: - 40°F to 140°F T=O
9 Storage temperatures Temp: - 40°F to 140°F T=O
Transport environment
Humidity: 0-96% (non-condensing)
Temp: - 22°F to 122°F
T=O
MOBILE OXYGEN STORAGE TANK (MOST) KEY PERFORMANCE PARAMETERS (KPP)
MOBILE OXYGEN STORAGE TANK (MOST) KEY SYSTEM ATTRIBUTES (KSA)
Kits/Accessories
a. Three (3) 20 ft long oxygen delivery hoses wound on individual holders
b. One end of the hose has a quick connect fitting that attaches to the oxygen output connector on the
MOST and the other end of the hose has a fitting that attaches to the flow selector
c. Three (3) flow selectors receive the oxygen from the oxygen delivery hoses at a minimum of 55 PSI
d. Flow selectors are adjustable 0-15 LPM
T=O
Oxygen Flow/Regulators
Adjustable flow of 0-15
LPM
T=O
Ballistic/fragmentation resistance testing
Pass gunfire test per DOT-
CFFC Basic Requirements
5th Ed. - Specified Gunfire
Test
T=O
Tank leakage
Less than 0.25 percent of total quantity per day T=O Bleed off in one year
15 Service life 15 years 30 years
Recertification test frequency
Hydrostatic testing every 5 years T=O
Oxygen Input / Type of Fill Valve
High pressure input port with standard high pressure
CGA oxygen fitting
T=O
FDA's recognized consensus standards for
Regulators, Pressure, Gas Cylinders: 1-81 CGA
V-5:2008 (Reaffirmed 2013), 1-97 CGA V-
7.1:2011, 1-99 ASTM G175-13, 1-100 CGA V-
1:2013, 1-130 ISO 18082 First edition 2014-06-
15, 1-167 CGA V-5:2019, 1-168 CGA V-
7.1:2021, 1-169 CGA V-1:2021, 1-183 ASTM
G175-24
18 Operational Availability (Ao) Ao = 95% Ao = 98%
Supportability
Support the system with parts, consumables, supplies, and available or purchasable software updates to make repairs for
7 years from the date of the last system sold.
Support the system with parts, consumables, supplies, and available or purchasable software updates to make repairs for 8 years from the date of the last system sold.
Reliability 350 hours mean time between failures
462 hours mean time between failures
Manuals
1 hard copy operator/user manual with sections identified in comments column
T=O
Includes theory of operation, trouble shooting, all maintenance and calibration requirements, illustrated parts breakdown with part numbers for each replaceable component, all applicable schematics [electronic, pneumatic, etc.].
Maintenance
Completed by biomedical maintenance technician with oxygen cleaned tools
T=O
23 Warranty 1 year > 1 year
Environmental Testing
Must pass all MIL-STD-
810H environmental testing
T=O
High/Low temperatures, humidity, salt/fog, sand/dust, rain/water, pressure/altitude, solar radiation, vibration, drop/shock, EMI
Container Material
a. Resistant to extreme weather
b. Fire-resistant
c. Chemical agent resistant
d. Corrosion resistant
e. Dust-proof
f. Moisture vapor proof
g. Provide protection to the contents from transit and storage damage due to vibration, shock, or compression
T=O
Oxygen Delivery/Flow
3 delivery ports pressure reduced to 55 psi, 50 LPM per port
T=O Specify the psi range to which pressure is reduced
Oxygen cylinder material and size N/A N/A
Specify cylinder material and sizes (capacity and dimensions) that are available