MIL-PRF-32383-X Summary of Spec Changes 30 January.xlsx

XLSX spreadsheet 12 KB Posted

Attached to
Conformal Wearable Batteries Federal contract opportunity
Solicitation number
Not on record
Issued by
Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground

About this file

This document provides updated draft specifications for Conformal Wearable Batteries. The specifications outline technical requirements for batteries to be used by soldiers, including revisions to environmental testing protocols, safety certification standards, and system integration requirements. Key changes include adding certifications for connector pull force, terminals, overtemperature cutoff, and protective devices. Testing procedures were updated for areas such as drop performance, digital display characteristics, and weapons effects. The document also defines a contractor-run weapons characterization test and provides more detail on system level integration testing to demonstrate battery interoperability.

View the file

Other files for this federal contract opportunity

Other files attached to Conformal Wearable Batteries, newest first.
File Type Posted
Amendment 02 CWB Additional Details.pdf PDF
MIL-PRF-32383-X 30 January 2020.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

SectionChange Made
3.0Type and PIN removed
3.0"Transit drop, normal" updated to grey (N/A) and "Nail Penetration, cell" is applicable- updated to black
3.11New Section added to describe requirement for system level integration
3.6Environmental requirements table (Table I) added and revised
3.7changed should to shall
4.4testing requirements updated- GR5 sample size and the deletion of GR6
4.4Table IV updated to reflect group updated and paragraph name/number changes
4.4Table IV, System level integration added to FAT table
4.5updated test requirements about sampling
6.13Weapons characterization note added
6.16pulse load rating changed to inrush load rating
2.2.1MIL-STD-1275 deleted
2.2.2ANSI/ASQ Z1.4 deleted
3.2.1Required certifications added:
3.2.1*Nett Warrior connector disconnect pull force (3.4.4.1.1.1)
3.2.1*Flat terminal (3.4.4.1.2)
3.2.1*High temperature temporary cutoff (3.7.2.4)
3.2.1*Protective devices (3.7.2.8.4)
3.2.1Updated certification table with all old and new certifications
3.4.4.1.1Name updated from Connector to Nett Warrior connector
3.4.4.1.1Note removed
3.4.4.1.1Nett warrior connector pinout description note updated (lines 152-155)
3.4.4.1.1.1name updated from connector disconnect pull force to net warrior connector disconnect pull force
3.4.4.1.5Paragraph number updated from 3.4.4.1.3 to 3.4.4.1.5
3.4.4.1.5Requirements paragraph updated
3.4.4.1.5step c was edited, word concurrent was deleted
3.4.5reformatted to show complete paragraph update
3.4.5Battery case requirement paragraph updated
3.4.5.6Requirement updated
3.4.5.6MIL-STD-130 was added in replace of MIL-STD-1472
3.4.5.6Surface friction requirement paragraph updated (last sentence added)
3.4.6.9paragraph number and name updated from 3.4.6.6.3 Terminal marking to 3.4.6.9 Net warrior connector marking
3.4.8.1Additional information added about dust cap/cover
3.5.11Added second paragraph
3.5.3Test capacity Requirements table was updated to show correct requirement and test method paragraph numbers
3.5.5note deleted
3.5.5Start time in step 6 was updated to felect the correct time of 2 seconds
3.5.8Paragraph name updated from State of charge/state of health indicator display characteristics to digital display characteristics
3.5.8Requirement paragraph updated to include RTTE and RTTF characteristics
3.5.8Safety requirements paragraph added
3.5.8changed paragraph number from 3.7.2.8.1 to 3.7
3.7.2.2 (11/19 version)deleted ( addition to overcharge / electrical leakage requirements) added to 3.7.2.2.1
3.7.2.2.1Overvoltage protection requirement added
3.7.2.4certification added
3.7.2.8Safety section added
3.7.2.8.1paragraph number changed from 3.7.2.8 to 3.7.2.8.1
3.7.2.8.1requirements reference added
3.7.2.8.1requirements paragraph updated to reflect "SOH should be reported as flashing "000""
3.7.2.8.3paragraph name changed from bullet penetration to weapons characterization test
3.7.2.8.4requirements added to reflect the addition of three protective devices
3.7.2.8.4name updated from pack safety protection circuits to battery safety protection circuits
3.7.2.8.4Changed last sentence from "protecting the output terminal" to "protecting all of the terminals"
4.5.1delete SMBus and Immersion from table
4.5.1Immersion added to Group A inspection (modified)
4.5.2add SMBus to Table VI
4.6.1test requirements updated
4.7.1.3.1name updated from connector disconnect pull force test to nett warrior connector disconnect pull force test
4.7.1.3.1testing requirements updated
4.7.2.11Note removed
4.7.2.14name updated from state-of-charge/state of health (SOC/SOH) display to digital display characteristics
4.7.2.14test methods updated
4.7.2.15test methods updated
4.7.2.16removed step e.
4.7.2.16defined which connector (Nett Warrior), modified test protocol
4.7.2.17added test requirement paragraph for USB power port connectors
4.7.3.8.1test requirements updated
4.7.3.8.1Added Group A testing only
4.7.3.8.1Modified test protocol for Group A
4.7.4.12testing paragraph updated
4.7.4.13Weapons characterization test updated- will be a contractor test
4.7.4.13name updated from bullet penetration to weapons characterization
4.7.4.13testing paragraph updated
4.7.4.13.1paragraph number changed from 4.7.4.13.2 to 4.7.4.13.1
4.7.4.7replacing step f.
4.7.4.7.1addition of overvoltage protection verification method
4.7.7RE102 changed
4.7.8System level integration testing paragraph updated
4.7.8Defined system level integration test
6.9.1content added
Figure 7Deleted notches.
Section 6from the previous version sections 6.13, 6.9, 6.14, and 6.15 were removed
Throughout the whole document- test paragraph numbers and requirement paragraph numbers were updated in each appropriate section.