X
X
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GLYCOL UPGRADE FOR PREHEAT
HOT WATER SYSTEM
79 Middleville Rd, Northport, NY 11768
632-22-137
B200N
JUNE 6, 2022 KNRevisions: Date:
200N
JD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GLYCOL UPGRADE FOR PREHEAT
HOT WATER SYSTEM
79 Middleville Rd, Northport, NY 11768
632-22-137
B200N
JUNE 6, 2022 KNRevisions: Date:
200N
JD
MH-101
BASEMENT MECHANICAL
DEMOLITION AND NEW WORK
PART PLANS
FULLY SPRINKLERED
SCALE:01 BASEEMENT DEMOLITION PART PLAN
1/4" =1'-0" SCALE:02 BASEMENT NEW WORK PART PLAN
1/4" =1'-0"
JD
AutoCAD SHX Text
XP-6
AutoCAD SHX Text
XP-1
AutoCAD SHX Text
XP-2
AutoCAD SHX Text
XP-3
AutoCAD SHX Text
XP-4
AutoCAD SHX Text
XP-5
AutoCAD SHX Text
XAS
AutoCAD SHX Text
XHX-6
AutoCAD SHX Text
XHX-5
AutoCAD SHX Text
XBPCV
AutoCAD SHX Text
XGMT
AutoCAD SHX Text
XDWH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XDCW
AutoCAD SHX Text
XDMW
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XGPHWR
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XPGHWR
AutoCAD SHX Text
TAGGED NOTES
AutoCAD SHX Text EXISTING PREHEAT GLYCOL HEATING WATER TO AH-1, AH-2. AH-3, AH-4 IN PENTHOUSE MER, BUILDING 200N. SYSTEM IS CURRENTLY FILLED WITH WATER ONLY. DRAIN PREHEAT GLYCOL HEATING WATER SYSTEM IN ITS ENTIRETY FROM PENTHOUSE TO BASEMENT INCLUDING PREHEAT COILS AT AH-1, AH-2. AH-3, AH-4 IN PENTHOUSE AND P-1, P-2, HX-1, HX-2 IN BASEMENT MER. VENT SYSTEM AT PENTHOUSE WHILE DRAINING.
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING PREHEAT GLYCOL HEATING WATER PUMP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING PREHEAT HEATING WATER PUMP
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING REHEAT HEATING WATER PUMP
AutoCAD SHX Text
AutoCAD SHX Text
REMOVE EXISTING GYCOL MAKE-UP SYSTEM, RETURN TO OWNER.
AutoCAD SHX Text
AutoCAD SHX Text CAP OFF EXISTING GLYCOL CONNECTION TO EXISTING PREHEAT GLYCOL HEATING WATER RETURN PIPING.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XAS
AutoCAD SHX Text
XHX-4
AutoCAD SHX Text
XHX-3
AutoCAD SHX Text
AutoCAD SHX Text
XDCW
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWR
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
XBPCV
AutoCAD SHX Text 3"
AutoCAD SHX Text
EXISTING EYEWASH STATION
AutoCAD SHX Text
AutoCAD SHX Text
XPHWS
AutoCAD SHX Text
XPHWR
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING PREHEAT HEATING WATER SUPPLY AND RETURN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XAS
AutoCAD SHX Text
XHX-2
AutoCAD SHX Text
XHX-1
AutoCAD SHX Text
AutoCAD SHX Text
XDCW
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWR
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
XBPCV
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING REHEAT HEATING WATER SUPPLY AND RETURN
AutoCAD SHX Text
AutoCAD SHX Text
XHWS
AutoCAD SHX Text
XHWR
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
DISCONNECT COLD WATER MAKE UP TO PREHEAT GLYCOL HEATING WATER SYSTEM.
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING STEAM PRESSURE REDUCING STATION
AutoCAD SHX Text
MER EO-54
AutoCAD SHX Text
XP-6
AutoCAD SHX Text
XP-1
AutoCAD SHX Text
XP-2
AutoCAD SHX Text
XP-3
AutoCAD SHX Text
XP-4
AutoCAD SHX Text
XP-5
AutoCAD SHX Text
XAS
AutoCAD SHX Text
XHX-6
AutoCAD SHX Text
XHX-5
AutoCAD SHX Text
XBPCV
AutoCAD SHX Text
GMT-1
AutoCAD SHX Text
XDWH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XDCW
AutoCAD SHX Text
XDMW
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XGPHWR
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XPGHWS
AutoCAD SHX Text
XPGHWR
AutoCAD SHX Text
TAGGED NOTES
AutoCAD SHX Text
NEW GLYCOL MAKE-UP SYSTEM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text INSTALL BALL VALVE WITH CAPPED 3/4" HOSE CONNECTION AT PREHEAT GLYCOL HEATING WATER PIPE STUB AND AT CHECK VALVE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XAS
AutoCAD SHX Text
XHX-4
AutoCAD SHX Text
XHX-3
AutoCAD SHX Text
AutoCAD SHX Text
XDCW
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWR
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
XBPCV
AutoCAD SHX Text 3"
AutoCAD SHX Text
XPHWS
AutoCAD SHX Text
XPHWR
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XAS
AutoCAD SHX Text
XHX-2
AutoCAD SHX Text
XHX-1
AutoCAD SHX Text
AutoCAD SHX Text
XDCW
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XHHWS
AutoCAD SHX Text
XHHWR
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
XBPCV
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text
XHWS
AutoCAD SHX Text
XHWR
AutoCAD SHX Text CONNECT GLYCOL DISCHARGE PIPE TO EXISTING GLYCOL PREHEAT HEATING WATER RETURN PIPING AT EXISTING STUB. PLUG GLYCOL MAKEUP UNIT INTO NEAREST WALL OUTLET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text CHARGE PREHEAT GLYCOL HEATING WATER SYSTEM WITH 30% SOLUTION OF PROPYLENE GLYCOL (APPROXIMATELY 1,000 GALLONS OF 30% SOLUTION) IN ITS ENTIRETY FROM BASEMENT TO PENTHOUSE INCLUDING PREHEAT COILS AT AH-1, AH-2. AH-3, AH-4 IN PENTHOUSE AND P-1, P-2, HX-1, HX-2 IN BASEMENT MER. VENT SYSTEM AT PENTHOUSE WHILE WHILE FILLING. AFTER CONFIRMING SYSTEM IS COMPLETELY FULL IN EVERY RESPECT AND FREE OF AIR, TEST SYSTEM FLOW WITH EXISTING PUMP P-1 IN BASEMENT MER. CONTRACTOR SHALL PROVIDE THE MEANS OF FILLING THE SYSTEM INCLUDING A PUMP AND ALL APPURTENANCES. THE NEW GLYCOL MAKE-UP SYSTEM PUMP IS NOT TO BE USED FOR FILLING SYSTEM. TEST OPERATION OF NEW GLYCOL MAKE-UP SYSTEM TO KEEP SYSTEM PROPERLY CHARGED.
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING EYEWASH STATION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING STEAM PRESSURE REDUCING STATION
AutoCAD SHX Text
MER EO-54