Metrocare_Pharmacy_Specifications_(10.17.25).pdf
PDF 4 MB Posted
- Attached to
- 9696 Skillman Pharmacy Renovation
- Solicitation number
- 2026-01-01
- Issued by
- Dallas County, Dallas City, Texas
About this file
This document is a Project Manual and Asbestos-Containing Building Materials (ACBM) Inspection Report for the Metrocare Pharmacy renovation project located at 9696 Skillman Street, Dallas, Texas 75243. The project involves the conversion of an existing 3,490 square foot office suite into a Class A closed pharmacy facility. Metrocare is soliciting formal proposals from General Contractors for full turn-key renovation services, including labor, materials, debris removal and disposal, and all necessary permitting. The preconstruction site walkthroughs are scheduled for Friday, January 23, 2026 at 1:00 p.m. C.T. and Monday, January 26, 2026 at 1:00 p.m. C.T., with construction anticipated to commence in March 2026. Metrocare facilities operate Monday through Friday from 8:00 a.m. to 5:00 p.m. The project scope includes comprehensive construction specifications across multiple divisions addressing concrete, carpentry, thermal and moisture protection, openings, finishes, specialty items, fire suppression, plumbing, HVAC, electrical systems, communications, and electronic safety and security systems designed to ensure structural integrity, energy efficiency, and compliance with healthcare facility regulations.
The May 9, 2025 asbestos inspection identified several asbestos-containing materials within the first floor renovation areas that require management prior to construction activities. Category II non-friable asbestos products were detected, including green adhesive associated with green marble wall base (2% chrysotile, 160 SF), beige sink undercoating (5% chrysotile, 5 SF), and grout and mortar associated with green marble flooring (presumed asbestos, 650 SF). The inspection encompassed 150 bulk material samples analyzed using Polarized Light Microscopy (PLM) with dispersion staining by Moody Labs, an NVLAP-accredited laboratory. Per Texas Asbestos Health Protection Rules (TAHPR), only licensed Asbestos Abatement Contractors may remove, repair, enclose, or encapsulate asbestos-containing materials, and all abatement activities must be monitored by a licensed Asbestos Consultant. The Texas Department of State Health Services must be notified at least 10 working days before initiating abatement activities. The proposal pricing shall encompass all costs associated with managing identified asbestos materials in compliance with NESHAP regulations and TAHPR requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8350 N Central Expy., Suite 1900 Dallas, TX 75206 www.sjearchitects.com
PROJECT MANUAL
Metrocare Pharmacy 9696 Skillman Street Suite 160 Dallas, TX
Project Number 25006.05 Issued For BID:
October 17, 2025 http://www.sjearchitects.com/
Metrocare Pharmacy 00 0110 - 1 TABLE OF CONTENTS
SECTION 00 0110
TABLE OF CONTENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
00 3100 AVAILABLE PROJECT INFORMATION
DIVISION 01 - GENERAL REQUIREMENTS
01 1000 SUMMARY
01 2000 PRICE AND PAYMENT PROCEDURES
01 2500 SUBSTITUTION PROCEDURES
01 2600 CONTRACT MODIFICATION PROCEDURES
01 3000 ADMINISTRATIVE REQUIREMENTS
01 3233 PHOTOGRAPHIC DOCUMENTATION
01 4000 QUALITY REQUIREMENTS
01 5000 TEMPORARY FACILITIES AND CONTROLS
01 6000 PRODUCT REQUIREMENTS
01 6116 VOLATILE ORGANIC COMPOUND (VOC) CONTENT RESTRICTIONS
01 7000 EXECUTION AND CLOSEOUT REQUIREMENTS
017419 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
01 7800 CLOSEOUT SUBMITTALS
DIVISION 02 - EXISTING CONDITIONS
02 4100 DEMOLITION
DIVISION 03 - CONCRETE
03 3000 CAST-IN-PLACE CONCRETE
DIVISION 04 – NOT USED
DIVISION 05 – NOT USED
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 1000 ROUGH CARPENTRY
06 4100 ARCHITECTURAL WOOD CASEWORK
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 9000 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 1112 HOLLOW METAL FRAMES
08 1416 FLUSH WOOD DOORS
08 3100 ACCESS DOORS AND PANELS
08 3313 COILING COUNTER DOORS
08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08 5659 SERVICE AND TELLER WINDOW UNITS
08 7100 DOOR HARDWARE
08 8000 GLAZING
DIVISION 09 - FINISHES
09 2116 GYPSUM BOARD ASSEMBLIES
09 3000 TILING
09 5100 ACOUSTICAL CEILINGS
09 6500 RESILIENT FLOORING
Metrocare Pharmacy 00 0110 - 2 TABLE OF CONTENTS
09 9000 PAINTING AND COATING
DIVISION 10 - SPECIALITIES
10 1423 PANEL SIGNAGE
10 2600 WALL PROTECTION
10 2800 TOILET ACCESSORIES
10 4400 FIRE PROTECTION SPECIALTIES
DIVISION 11 - NOT USED.
DIVISION 12 – NOT USED
12 3600 COUNTERTOPS
DIVISIONS 13 THRU 20 – NOT USED
DIVISION 21 – FIRE SUPRESSION
21 1300 FIRE-SUPPRESSION SPRINKLER SYSTEMS
DIVISION 22 – PLUMBING
22 0517 SLEEVES AND SEALS FOR PLUMBING PIPING
22 0523 GENERAL-DUTY VALVES FOR PLUMBING PIPING
22 0529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
22 0553 IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT
22 0719 PLUMBING PIPING INSULATION
22 1005 PLUMBIGN PIPING
22 1006 PLUMBING PIPING SPECIALTIES
22 3000 PLUMBING EQUIPMENT
22 4000 PLUMBING FIXTURES
DIVISION 23 – HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 0529 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
23 0548 VIBRATION AND SEISMIC CONTROLS FOR HVAC
23 0553 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT
23 0593 TESTING ADJUSTING AND BALANCING FOR HVAC
23 0713 DUCT INSULATION
23 0713 HVAC EQUIPMENT INSULATION
23 0719 HVAC PIPING INSULATION
23 0800 COMMISSIONING OF HVAC
23 0913 INSTRUMENTATION AND CONTROL OF DEVICES FOR HVAC
23 0923 DIRECT-DIGITAL CONTROL SYSTEMS FOR HVAC
23 2300 REFRIGERANT PIPING
23 3100 HVAC DUCTS AND CASINGS
23 3300 AIR DUCT ACCESSORIES
23 3423 HVAC POWER VENTILATOR
23 3600 AIR TERMINAL UNITS
23 3700 AIR OUTLETS AND INLTES
23 4000 HVAC AIR CLEANING DEVICES
23 8126.13 SMALL-CAPACITY SPLIT-SYSTEM AIR CONDITIONERS
DIVISION 26 – ELECTRICAL
26 0001 GENERAL PROVISIONS
26 0519 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
26 0526 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
26 0529 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
26 0533.13 CONDUIT FOR ELECTRICAL SYSTEMS
Metrocare Pharmacy 00 0110 - 3 TABLE OF CONTENTS
26 0533.16 BOXES FOR ELECTRICAL SYSTEMS
26 0533.23 SURFACE RACEWAYS FOR ELECTRICAL SYSTEMS
26 0553 IDENTIFICATION FOR ELECTRICAL SYSTEMS
26 0583 WIRING CONNECTIONS
26 0923 LIGHTING CONTROL DEVICES
26 2100 LOW VOLTAGE ELECTRICAL SERVICE EQUIPMENT
26 2200 LOW VOLTAGE TRANSFORMERS
26 2413 SWITCHBOARDS
26 2416 PANELBOARDS
26 2726 WIRING DEVICES
26 2813 FUSES
26 2816.13 ENCLOSED CIRCUIT BREAKERS
26 2816.16 ENCLOSED SWITCHES
26 2913 ENCLOSED CONTROLLERS
26 4300 SURGE PROTECTIVE DEVICES
26 5100 INTERIOR LIGHTING
26 5600 EXTERIOR LIGHTING
DIVISION 27 – COMMUNICATIONS
27 0529 HANGERS AND SUPPORTS FOR COMMUNICATIONS SYSTEMS
27 0533.13 CONDUIT FOR COMMUNICATIONS SYSTEMS
27 1000 STRUCTURED CABLING
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
28 1000 ACCESS CONTROL
28 1523 INTERCOM ENTRY SYSTEMS
28 4600 FIRE DETECTION AND ALARM
DIVISIONS 29 THROUGH 49 – NOT USED
Metrocare Pharmacy 00 0110 - 4 TABLE OF CONTENTS
THIS PAGE IS INTENTIONALLY BLANK
Metrocare Pharmacy 00 3100 - 1 Available Project Information
SECTION 00 3100
AVAILABLE PROJECT INFORMATION
PART 1 GENERAL
1.01 EXISTING CONDITIONS
A. Hazardous Material Survey: Entitled Pre-Renovation Asbestos-Containing Building Materials Inspection Commercial Office Building - First Floor Renovation Areas 9696 Skillman Street, dated May 9, 2025. A copy of the report follows the next page.
PART 2 PRODUCTS (NOT USED)
PART 3 EXECUTION (NOT USED)
END OF SECTION
This page intentionally left blank
May 9, 2025
Mr. Adam Geilman Assistant Project Manager Facilities Planning & Construction Metrocare Services 1330 River Bend Drive Dallas, Texas 75247
RE: Pre-Renovation Asbestos-Containing Building Materials Inspection Commercial Office Building – First Floor Renovation Areas 9696 Skillman Street – Dallas, Texas 75243
Farmer Environmental Group Project No. 5859.09
Mr. Geilman:
Enclosed is Farmer Environmental Group’s Asbestos-Containing Building Materials Inspection Report for the Commercial Office Building located at 9696 Skillman Street in Dallas, Texas.
Farmer Environmental Group appreciates this opportunity to provide asbestos consulting services to Metrocare Services. We have enjoyed working with you on this project and look forward to meeting your needs in the future. Should any questions arise concerning this report, please contact us at (972) 390-8014.
Sincerely, John Purcell TDSHS Asbestos Inspector #603293
Principal Review:
Robert Alexander, Chief Operating Officer TDSHS Individual Asbestos Consultant #105196 Farmer Environmental Group, LLC
APPENDICES :
Appendix I: Bulk Sample Analysis Appendix II: Bulk Sample and Presumed Asbestos Location Drawings Appendix III: Texas Department of State Health Services Licenses
ASBESTOS-CONTAINING BUILDING MATERIALS
INSPECTION REPORT
Commercial Office Building 9696 Skillman Street Dallas, Texas 75243
May 9, 2025
I. INTRODUCTION
Farmer Environmental Group, LLC (Farmer) inspected the First Floor of the Commercial Office Building (the Site) located at 9696 Skillman Street in Dallas, Texas for asbestos-containing building materials (ACBM) on April 30 & May 1, 2025. Texas Department of State Health Services (TDSHS)-licensed Asbestos Inspector John Purcell (license #603293) conducted this inspection under an agreement between Farmer and Metrocare Services. The scope of work included all suspect accessible interior materials on the first floor that may be affected by future renovation activities at the site. Exterior & roofing materials were specifically excluded from the scope of work.
The purpose of the inspection was threefold: 1) determine locations and conditions of asbestos-containing products used at the Site; 2) determine the impact these materials will have on planned renovation activities; and 3) assist Metrocare Services and/or their client in obtaining the necessary building permit with the City of Dallas in accordance with Senate Bill 509.
II. SUMMARY OF FINDINGS & RECOMMENDATIONS
Based on the laboratory analysis of the bulk samples collected, the following asbestos products were identified at the Site:
• Green adhesive associated with green marble wall base
• Beige sink undercoating
• Grout & mortar associated with green marble flooring (presumed)
Farmer was unable to sample the green marble flooring in the main lobby without causing significant damage to the flooring. Therefore, the flooring grout and mortar should be presumed to contain asbestos until testing becomes feasible.
It should be noted that the inspector made reasonable attempts to determine whether suspect flooring applications were present beneath existing flooring materials. However, suspect asbestos-containing flooring materials may be present under existing flooring materials that were inaccessible without significantly damaging floor covering. Farmer has extensive experience with commercial structures that have been abated prior to demolition or renovation projects. Because commercial renovations occur from time to time, existing asbestos-containing floor mastics are occasionally found in sporadic areas under new flooring materials. Although representative samples of existing flooring materials were collected and analyzed for asbestos content during the asbestos inspection, an asbestos inspector cannot confirm that no suspect flooring mastics exist in other areas without removing all the existing flooring materials. Therefore, demolition of flooring materials should proceed with caution. If suspect flooring materials not identified in this report are uncovered during demolition activities, flooring material demolition should cease until samples of the suspect floor material are analyzed for asbestos content.
Beneficiaries of this report should be aware that Farmer did not have permission to conduct destructive testing within the structure at the time of our assessment.
As a result, no demolition for access was conducted behind wet walls, columns, hard ceilings, etc. Farmer made reasonable efforts to access all materials without damaging building finish-out. Destructive testing should be conducted prior to any demolition or renovation activities that may impact interstitial wall spaces, columns, hard ceilings, or otherwise concealed materials.
Additional bulk samples should be collected from previously concealed materials that may be revealed during demolition activity, or from materials outside the original inspection scope of work. "Suspect" material includes any material serving as a sprayed-on or troweled-on acoustic or fireproofing surface; floor and ceiling tiles, cement asbestos panels, siding, or shingles; thermal insulation or any material associated with mechanical systems; or any binding agent such as tar sealant, mastic adhesive, roofing tar, caulking, etc. TDSHS regulations require bulk samples in public buildings be collected by a licensed asbestos inspector or individual asbestos consultant.
III. SAMPLE RESULTS
ASBESTOS AND NON-ASBESTOS PRODUCTS IN THE FACILITY
The PLM Report in Appendix I shows the results of PLM analysis for bulk samples collected at the Site, as required under Task 1 above. The PLM Report shows the room or area in which the sample was collected and provides a description of the sampled material. Site drawings are included in Appendix II.
Any product containing greater than 1% fibrous asbestos, when analyzed by PLM, is considered a potential hazard by the United States Environmental Protection Agency (US EPA). However, it should be noted that the Texas Asbestos Health Protection Rules (TAHPR) lowered the threshold level in Texas from ‘greater than one percent asbestos’ (current US EPA guideline) to ‘one percent or greater’ as of July 8, 2021. PLM is the US
EPA-recognized method for determining fibrous bulk asbestos content. Additionally, the US EPA indicates that further analysis by point counting be performed to confirm asbestos content for friable materials found to contain less than ten percent asbestos by visual area estimation. Point counting analysis may be omitted if the material is assumed to contain equal to or more than one percent asbestos and is then handled accordingly. All samples collected by Farmer were analyzed by Moody Labs, LLC, a TDSHS-licensed and National Voluntary Laboratory Accreditation Program (NVLAP)-accredited laboratory located in Farmers Branch, Texas. The samples were analyzed by PLM coupled with dispersion staining, in general accordance with US EPA-600/R-93/116. Utilizing this procedure, the various asbestos minerals (chrysotile, amosite, crocidolite, actinolite, tremolite, and anthophyllite) can be determined by the microscopist.
Sample analysis reported as "None Detected" should be interpreted as meaning no asbestos was observed in the suspect material above the reliable limit of detection, (Less Than 1% by visual estimation) for the PLM method.
Sample analysis reported as "Not Analyzed – Positive Stop" should be interpreted as meaning a sample of the same homogeneous material was analyzed with an asbestos content equal to or greater than 1%. Further analysis is therefore considered unnecessary.
The US EPA's National Emission Standards for Hazardous Air Pollutants (NESHAP) asbestos regulation (US EPA 40 CFR 61, Subpart M) classifies asbestos-containing materials into the following three categories:
Category I Category I Non-Friable ACM refers to asbestos-containing packing, gaskets resilient floor covering, and asphalt roofing products containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Category II Category II Non-Friable ACM is any non-friable material that is not Category I and contains greater than 1% asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
RACM Regulated Asbestos-Containing Materials (RACM) is a friable (reducible to powder by hand pressure) manufactured ACM; or a Category I non-friable ACM that has become friable; or a Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading; or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations. RACM should be removed prior to renovation or demolition activities.
RACM is further defined by NESHAP as:
a) Friable asbestos material;
b) Category I nonfriable ACM that has become friable;
c) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or
d) Category II nonfriable ACM that has become crumbled, pulverized, or reduced to powder or has a high probability of becoming crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by NESHAP asbestos regulation (US EPA 40 CFR 61, Subpart M).
The following category II non-friable asbestos products (materials not reducible to a powder or dust form under normal hand pressure) were identified at the Site:
Table 1 – Category 2 Non-Friable ACM
Material Description Estimated Quantity
Asbestos Content
Location / Condition
Grout & Mortar associated with Green Marble Flooring
650 SF Presumed Main Lobby / Good
Green Adhesive associated with Green Marble Wall Base
160 SF 2% Chrysotile Main Lobby / Good
Beige Sink Undercoating 5 SF 5% Chrysotile Suite 100-A Break
Room / Good
Suite 100-A & B
1. Yellow carpet mastic
2. Yellow rubber cove base mastic
3. Carpet cove base mastic
4. Brown 12” x 12” vinyl floor tile, adhesive, & floor float
5. Drywall, light sandy texture, & associated joint compound
6. Drywall, light sandy drip texture, & associated joint compound
7. White 2’ x 2’ lay-in ceiling tile (pinhole & small divot pattern)
8. White 2’ x 2’ lay-in ceiling tile (pinhole & large divot pattern)
9. White 2’ x 2’ lay-in ceiling tile (pinhole & large fissure pattern)
10. Drywall, sandy texture, & associated joint compound
11. White ceramic wall base grout & thinset
12. White ceramic floor tile grout & mortar
13. Drywall, wall covering, & joint compound
Common Areas & Restrooms
14. Gray 2” x 2” ceramic wall tile grout & adhesive
15. Gray 2” x 2” ceramic floor tile grout, adhesive, & leveling compound
16. Drywall, smooth texture, & associated joint compound
17. Yellow carpet mastic
18. Gray vinyl wall covering
Church Suite
19. Drywall, smooth texture, & associated joint compound
20. Tan adhesive associated with wood plank flooring
21. White cove base mastic
22. Tan 12” x 12” vinyl floor tile with yellow mastic
23. Gray concrete floor coating
24. White 2’ x 2’ lay-in ceiling tile (pinhole & fissure pattern)
25. White 2’ x 2’ lay-in ceiling tile (semi-rough finish)
Suite 150
26. Gray ceramic floor tile, grout, & yellow mastic
27. Yellow carpet mastic
28. Drywall, smooth texture & associated joint compound
29. White 2’ x 2’ lay-in ceiling tile (smooth finish)
30. Drywall wall covering
Former Bank
31. Yellow carpet mastic
32. Yellow cove base mastic
33. Drywall, wall covering, & associated joint compound
34. Drywall, smooth texture, & associated joint compound
35. White 2’ x 2’ lay-in ceiling tile (pinhole & divot pattern)
36. Counter caulk
37. White 2’ x 2’ lay-in ceiling tile (pinholes with bumpy finish)
38. Tan millwork adhesive
39. Tan 12” x 12” vinyl floor tile with yellow mastic
40. Grout & mortar associated with red ceramic flooring
41. Grout & mortar associated with tan ceramic wall tile
42. Restroom fixture caulk
Suite 150 - B
43. Yellow carpet mastic
44. Drywall, rolled texture, & associated joint compound
45. Tan carpet wall base mastic
46. White 2’ x 2’ lay-in ceiling tile (smooth finish)
47. Beige HVAC duct mastic
IV. RECOMMENDATIONS
Based on observations made at the Site, and results of the analysis of bulk samples collected during the inspection, Farmer recommends the following:
1. TAHPR dictates that only a licensed Asbestos Abatement Contractor can remove, repair, enclose, or encapsulate asbestos containing material. TAHPR further dictates that the asbestos abatement activity be monitored by a licensed Asbestos Consultant.
2. Green marble flooring should be tested for the presence of asbestos-containing grout & mortar prior to renovation activities that will impact these materials.
3. According to TAHPR, TDSHS must be notified of any asbestos abatement of a structure regardless of size. Notifications must be postmarked at least 10 working days before initiating abatement activities and must be made using TDSHS forms.
Forms can be obtained by contacting the TDSHS Asbestos Notification and Information Section at 1-800-572-5548 or online through the TDSHS website at www.dshs.state.tx.us.
4. To comply with National Emission Standards for Hazardous Air Pollutants (NESHAP) asbestos regulation (EPA 40 CFR 61, Subpart M), Farmer recommends removing all friable and non-friable ACBM that has the potential to become friable under abatement conditions prior to renovation or demolition activities.
5. Additional bulk samples should be collected from previously concealed materials that may be revealed during demolition activity, or from materials outside the original inspection scope of work. "Suspect" material includes any material serving as a sprayed on or troweled on acoustic or fireproofing surface; floor and ceiling tiles;
transite panels, siding, or shingles; thermal insulation or any material associated with mechanical systems; or any binding agent such as tar sealant, mastic adhesive, roofing tar, caulking, et cetera. TDSHS regulations require bulk samples in public buildings be collected by a licensed asbestos inspector or individual asbestos consultant.
6. The building owner should be aware that removing ACBM does not discharge ownership. During transport or after burial in an EPA-approved landfill, any contamination throughout the lifetime of the material remains the responsibility of the building owner.
7. If any material cannot be positively identified as non-asbestos containing by the analytical results of samples collected during this inspection, it should be treated as asbestos until a sample of the newly identified suspect material can be collected and analyzed by PLM.
8. During renovation activities, the client should ascertain the contents of any new products (obtain Safety Data Sheets) installed in the building that would avoid the accuracy and validity of this inspection report.
9. According to the Occupational Safety and Health Administration (OSHA) 29 Code of
Federal Regulations (CFR) 1926.1101, building and/or facility owners shall notify the following persons of the presence, location, and quantity of asbestos-containing materials, at the work sites in their buildings. Notification either shall be in writing, or shall consist of a personal communication between the owner and the person to whom notification must be given or their authorized representative:
a) Prospective employers applying or bidding for work whose employees reasonably can be expected to work in or adjacent to areas containing such material;
b) Employees of the owner who will work in or adjacent to areas containing such material;
c) On multi-employer work sites, all employers of employees who will be performing work within or adjacent to areas containing such materials;
d) Tenants who will occupy areas containing such material.
V. LIMITATIONS
Farmer has endeavored to inspect the existing conditions within the affected areas using TAHPR inspection protocols. Regardless of the thoroughness of an inspection, it is possible that some areas containing asbestos were overlooked or inaccessible. This report presents general descriptions of various construction materials and the general locations where these materials were encountered. If questions arise during the planning for renovation, demolition or other construction, Farmer should be notified to permit a review of the situation and to present recommendations.
As noted above, beneficiaries of this report should be aware that Farmer did not have permission to conduct destructive testing within the structure at the time of our assessment. As a result, no demolition for access was conducted behind wet walls, columns, hard ceilings, etc. Farmer made reasonable efforts to access all materials without damaging building finish-out. Destructive testing should be conducted prior to any demolition or renovation activities that may impact interstitial wall spaces, columns, hard ceilings, or otherwise concealed materials.
This report has been prepared on behalf of and exclusively for the use of Metrocare Services and their client. The conclusions expressed by Farmer regarding the conditions of the site are based solely on the observations made on April 30 & May 1, 2025, the data collected during this inspection, and the laboratory results of the samples collected and analyzed.
The beneficiaries are hereby advised that conditions observed are subject to change.
This report and the findings contained herein shall not, in whole or in part, be disseminated or conveyed to any other party or be used or relied upon by any other party, in whole or in part, without Metrocare Services’ or Farmer's prior written consent.
APPENDIX I
BULK SAMPLE ANALYSIS
PLM Summary Report
Client :
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32637 Carpet Mastic (Yellow), Office 1 None Detected - Yellow Mastic
E32638 Carpet Mastic (Yellow), Open Area None Detected - Yellow Mastic
E32639 Carpet Mastic (Yellow), Cubes Area None Detected - Yellow Mastic
E32640 Rubber Cove Base Mastic (Yellow), Break Room None Detected - Yellow Mastic
E32641 Rubber Cove Base Mastic (Yellow), Break Room None Detected - Yellow Mastic
E32642 Rubber Cove Base Mastic (Yellow), Break Room None Detected - Yellow Mastic
E32643 Carpet Cove Base Mastic (Tan), Open Area None Detected - Tan Mastic
E32644 Carpet Cove Base Mastic (Tan), Open Area None Detected - Tan Mastic
E32645 Carpet Cove Base Mastic (Tan), Conference Room None Detected - Tan Mastic
E32646 12" x 12" Vinyl Floor Tile (Brown), Adhesive and Floor
Float, Break Room
None Detected - Floor Tile
None Detected - Yellow Adhesive
None Detected - Floor Float
E32647 12" x 12" Vinyl Floor Tile (Brown), Adhesive and Floor
Float, Break Room
None Detected - Floor Tile
None Detected - Yellow Adhesive
None Detected - Floor Float
E32648 12" x 12" Vinyl Floor Tile (Brown), Adhesive and Floor
Float, Break Room
None Detected - Floor Tile
None Detected - Yellow Adhesive
None Detected - Floor Float
E32649 Drywall, Texture (Light Sandy) and Joint Compound, Office
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32650 Drywall, Texture (Light Sandy) and Joint Compound, Open
Area
None Detected - Drywall Material
None Detected - Texture / Joint Cmpd
E32651 Drywall, Texture (Light Sandy) and Joint Compound, Office
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32652 Drywall, Texture (Light Sandy Drip) and Joint Compound, Suite 100B Office 1
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32653 Drywall, Texture (Light Sandy Drip) and Joint Compound, Suite 100B Office 3
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32654 Drywall, Texture (Light Sandy Drip) and Joint Compound, Suite 100B Office 7
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32655 2' x 2' Lay-in Ceiling Tile (White, Pinhole and Small
Divots), Reception Suite 100A
None Detected - Acoustic Tile
E32656 2' x 2' Lay-in Ceiling Tile (White, Pinhole and Small
Divots), Cubes Suite 100A
None Detected - Acoustic Tile
E32657 2' x 2' Lay-in Ceiling Tile (White, Pinhole and Small
Divots), Office 3 Suite 100A
None Detected - Acoustic Tile
E32658 2' x 2' Lay-in Ceiling Tile (White Pinhole and Large
Divots), Office 1 Suite 100A
None Detected - Acoustic Tile
E32659 2' x 2' Lay-in Ceiling Tile (White Pinhole and Large
Divots), Cubes Suite 100A
None Detected - Acoustic Tile
E32660 2' x 2' Lay-in Ceiling Tile (White Pinhole and Large
Divots), Office 5 Suite 100A
None Detected - Acoustic Tile
E32661 2' x 2' Lay-in Ceiling Tile (White Pinhole and Large
Fissure), Open Area Suite 100B
None Detected - Acoustic Tile
E32662 2' x 2' Lay-in Ceiling Tile (White Pinhole and Large
Fissure), Office 7 Suite 100B
None Detected - Acoustic Tile
E32663 2' x 2' Lay-in Ceiling Tile (White Pinhole and Large
Fissure), Office 4 Suite 100B
None Detected - Acoustic Tile
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32664 Drywall, Texture (Sandy) and Joint Compound, Reception
Closet Suite 100A
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Textured Paint
E32665 Drywall, Texture (Sandy) and Joint Compound, Reception
Closet Suite 100A
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Textured Paint
E32666 Drywall, Texture (Sandy) and Joint Compound, Reception
Closet Suite 100A
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Textured Paint
E32667 Ceramic Wall Base (White) Grout and Thinset, Vending
Machine Room
None Detected - Grout
None Detected - Thinset
E32668 Ceramic Wall Base (White) Grout and Thinset, Vending
Machine Room
None Detected - Grout
None Detected - Thinset
E32669 Ceramic Wall Base (White) Grout and Thinset, Vending
Machine Room
None Detected - Grout
None Detected - Thinset
E32670 Ceramic Floor Tile (White) Grout and Mortar, Vending
Machine Room
None Detected - Grout
None Detected - Mortar
E32671 Ceramic Floor Tile (White) Grout and Mortar, Vending
Machine Room
None Detected - Grout
None Detected - Mortar
E32672 Ceramic Floor Tile (White) Grout and Mortar, Vending
Machine Room
None Detected - Grout
None Detected - Mortar
E32673 Drywall Wall Covering and Joint Compound, Vending
Machine Room
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Wall Covering
E32674 Drywall Wall Covering and Joint Compound, Vending
Machine Room
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Wall Covering
E32675 Drywall Wall Covering and Joint Compound, Vending
Machine Room
None Detected - Drywall Material
None Detected - Wall Covering
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32676 2" x 2" Ceramic Wall Tile (Gray) Grout and Adhesive, Restrooms
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Tan Adhesive
E32677 2" x 2" Ceramic Wall Tile (Gray) Grout and Adhesive, Restrooms
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Tan Adhesive
E32678 2" x 2" Ceramic Wall Tile (Gray) Grout and Adhesive, Restrooms
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Tan Adhesive
E32679 2" x 2" Ceramic Floor Tile (Gray), Grout, Thinset and
Leveling Compound, Restrooms
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Thinset
None Detected - Leveling Compound
E32680 2" x 2" Ceramic Floor Tile (Gray), Grout, Thinset and
Leveling Compound, Restrooms
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Thinset
None Detected - Leveling Compound
E32681 2" x 2" Ceramic Floor Tile (Gray), Grout, Thinset and
Leveling Compound, Restrooms
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Thinset
None Detected - Leveling Compound
E32682 Drywall, Texture (Smooth) and Joint Compound, Common
Corridor
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32683 Drywall, Texture (Smooth) and Joint Compound, Common
Corridor
None Detected - Drywall Material
None Detected - Texture / Joint Cmpd
E32684 Drywall, Texture (Smooth) and Joint Compound, Corridor
Ceiling
None Detected - Drywall Material
None Detected - Texture / Joint Cmpd
E32685 Marble Tile Wall Base Adhesive (Green), Entry Foyer 2% Chrysotile - Green Adhesive
E32686 Marble Tile Wall Base Adhesive (Green), Entry Foyer Not Analyzed - Positive Stop
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32687 Marble Tile Wall Base Adhesive (Green), Entry Foyer Not Analyzed - Positive Stop
E32688 Drywall, Texture (Smooth) and Joint Compound, Church
Suite
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32689 Drywall, Texture (Smooth) and Joint Compound, Church
Suite
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32690 Drywall, Texture (Smooth) and Joint Compound, Church
Suite
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32691 Adhesive (Tan) associated with Wood Flooring, Church
Suite
None Detected - Tan Adhesive
E32692 Adhesive (Tan) associated with Wood Flooring, Church
Suite
None Detected - Tan Adhesive
E32693 Adhesive (Tan) associated with Wood Flooring, Church
Suite
None Detected - Tan Adhesive
E32694 Cove Base Adhesive (White), Church Suite None Detected - White Adhesive
E32695 Cove Base Adhesive (White), Church Suite None Detected - White Adhesive
E32696 Cove Base Adhesive (White), Church Suite None Detected - White Adhesive
E32697 12" x 12" Vinyl Floor Tile (Tan) and Mastic (Yellow), Church Suite Storage
None Detected - Floor Tile
None Detected - Yellow Mastic
E32698 12" x 12" Vinyl Floor Tile (Tan) and Mastic (Yellow), Church Suite Storage
None Detected - Floor Tile
None Detected - Yellow Mastic
E32699 12" x 12" Vinyl Floor Tile (Tan) and Mastic (Yellow), Church Suite Storage
None Detected - Floor Tile
None Detected - Yellow Mastic
E32700 Concrete Floor Coating (Gray), Church Kitchen None Detected - Concrete
None Detected - Epoxy Flooring
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32701 Concrete Floor Coating (Gray), Church Kitchen None Detected - Concrete
None Detected - Epoxy Flooring
E32702 Concrete Floor Coating (Gray), Church Changing Room None Detected - Concrete
None Detected - Epoxy Flooring
E32703 2' x 2' Lay-in Ceiling Tile (White Pinhole and Fissure), Church Suite
None Detected - Acoustic Tile
E32704 2' x 2' Lay-in Ceiling Tile (White Pinhole and Fissure), Church Suite
None Detected - Acoustic Tile
E32705 2' x 2' Lay-in Ceiling Tile (White Pinhole and Fissure), Church Suite
None Detected - Acoustic Tile
E32706 2' x 2' Lay-in Ceiling Tile (White Semi-Rough Finish), Church Suite
None Detected - Acoustic Tile
E32707 2' x 2' Lay-in Ceiling Tile (White Semi-Rough Finish), Church Suite
None Detected - Acoustic Tile
E32708 2' x 2' Lay-in Ceiling Tile (White Semi-Rough Finish), Church Suite
None Detected - Acoustic Tile
E32709 Ceramic Floor Tile (Gray) Grout, Mortar and Mastic
(Yellow), Suite 150
None Detected - Grout
None Detected - Mortar
None Detected - Yellow Mastic
E32710 Ceramic Floor Tile (Gray) Grout, Mortar and Mastic
(Yellow), Suite 150
None Detected - Grout
None Detected - Mortar
None Detected - Yellow Mastic
E32711 Ceramic Floor Tile (Gray) Grout, Mortar and Mastic
(Yellow), Suite 150
None Detected - Grout
None Detected - Mortar
None Detected - Yellow Mastic
E32712 Carpet Mastic (Yellow), Suite 150 Open Area None Detected - Yellow Mastic
E32713 Carpet Mastic (Yellow), Conference Room None Detected - Yellow Mastic
E32714 Carpet Mastic (Yellow), Corridor None Detected - Yellow Mastic
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32715 Drywall, Texture (Smooth) and Joint Compound, Suite 150 None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32716 Drywall, Texture (Smooth) and Joint Compound, Suite 150 None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32717 Drywall, Texture (Smooth) and Joint Compound, Suite 150 None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32718 2' x 2' Lay-in Ceiling Tile (White Smooth Finish), Suite 150 None Detected - Acoustic Tile
E32719 2' x 2' Lay-in Ceiling Tile (White Smooth Finish), Suite 150 None Detected - Acoustic Tile
E32720 2' x 2' Lay-in Ceiling Tile (White Smooth Finish), Suite 150 None Detected - Acoustic Tile
E32721 Carpet Cove Base Mastic (Tan), Suite 150 None Detected - Tan Mastic
E32722 Carpet Cove Base Mastic (Tan), Suite 150 None Detected - Tan Mastic
E32723 Carpet Cove Base Mastic (Tan), Suite 150 None Detected - Tan Mastic
E32724 Drywall Wall Covering, Suite 150 None Detected - Wall Covering
E32725 Drywall Wall Covering, Suite 150 None Detected - Wall Covering
E32726 Drywall Wall Covering, Suite 150 None Detected - Wall Covering
E32727 Carpet Mastic (Yellow), Former Bank, Lobby None Detected - Yellow Mastic
E32728 Carpet Mastic (Yellow), Former Bank, Vault None Detected - Yellow Mastic
E32729 Carpet Mastic (Yellow), Former Bank, Workroom None Detected - Yellow Mastic
E32730 Cove Base Mastic (Yellow), Former Bank, Corridor None Detected - Yellow Mastic
E32731 Cove Base Mastic (Yellow), Former Bank, Corridor None Detected - Yellow Mastic
E32732 Cove Base Mastic (Yellow), Former Bank, Workroom None Detected - Yellow Mastic
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32733 Drywall, Wall Covering and Joint Compound, Former Bank
Office 1
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Wall Covering
E32734 Drywall, Wall Covering and Joint Compound, Former Bank
Conference
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Wall Covering
E32735 Drywall, Wall Covering and Joint Compound, Former Bank
Office 3
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Wall Covering
E32736 Drywall, Texture (Smooth) and Joint Compound, Former
Bank Break Room
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32737 Drywall, Texture (Smooth) and Joint Compound, Former
Bank Open Area
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32738 Drywall, Texture (Smooth) and Joint Compound, Former
Bank Vault
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32739 2' x 2' Lay-in Ceiling Tile (White, Pinhole and Divot), Former Bank Vault
None Detected - Acoustic Tile
E32740 2' x 2' Lay-in Ceiling Tile (White, Pinhole and Divot), Former Bank Vault
None Detected - Acoustic Tile
E32741 2' x 2' Lay-in Ceiling Tile (White, Pinhole and Divot), Former Bank Viewing Room
None Detected - Acoustic Tile
E32742 Counter Caulk, Former Bank Viewing Room None Detected - Caulking
E32743 Counter Caulk, Former Bank Viewing Room None Detected - Caulking
E32744 Counter Caulk, Former Bank Viewing Room None Detected - Caulking
E32745 2' x 2' Lay-in Ceiling Tile (White, Pinholes with Bumpy
Finish), Former Bank Lobby
None Detected - Acoustic Tile
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32746 2' x 2' Lay-in Ceiling Tile (White, Pinholes with Bumpy
Finish), Former Bank Open Area
None Detected - Acoustic Tile
E32747 2' x 2' Lay-in Ceiling Tile (White, Pinholes with Bumpy
Finish), Former Bank Open Area
None Detected - Acoustic Tile
E32748 Millwork Adhesive (Tan), Former Bank Workroom None Detected - Tan Mastic
E32749 Millwork Adhesive (Tan), Former Bank Workroom None Detected - Tan Mastic
E32750 Millwork Adhesive (Tan), Former Bank Workroom None Detected - Tan Mastic
E32751 12" x 12" Vinyl Floor Tile (Tan) with Mastic (Yellow), Former Bank Closet
None Detected - Floor Tile
None Detected - Yellow Mastic
E32752 12" x 12" Vinyl Floor Tile (Tan) with Mastic (Yellow), Former Bank Closet
None Detected - Floor Tile
None Detected - Yellow Mastic
E32753 12" x 12" Vinyl Floor Tile (Tan) with Mastic (Yellow), Former Bank Closet
None Detected - Floor Tile
None Detected - Yellow Mastic
E32754 Grout and Mortar associated with Ceramic Floor Tile (Red), Former Bank Employee Restroom
None Detected - Grout
None Detected - Mortar
E32755 Grout and Mortar associated with Ceramic Floor Tile (Red), Former Bank Employee Restroom
None Detected - Grout
None Detected - Mortar
E32756 Grout and Mortar associated with Ceramic Floor Tile (Red), Former Bank Employee Restroom
None Detected - Grout
None Detected - Mortar
E32757 Grout (Tan) and Mortar (Gray) associated with Ceramic
Wall Tile (Tan), Former Bank Employee Restroom
None Detected - Grout
None Detected - Mortar
E32758 Grout (Tan) and Mortar (Gray) associated with Ceramic
Wall Tile (Tan), Former Bank Employee Restroom
None Detected - Grout
None Detected - Mortar
E32759 Grout (Tan) and Mortar (Gray) associated with Ceramic
Wall Tile (Tan), Former Bank Employee Restroom
None Detected - Grout
None Detected - Mortar
E32760 Restroom Fixture Caulk, Former Bank Employee Restroom None Detected - Caulking
E32761 Restroom Fixture Caulk, Former Bank Employee Restroom None Detected - Caulking
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32762 Restroom Fixture Caulk, Former Bank Employee Restroom None Detected - Caulking
E32763 Drywall, Texture (Smooth) and Joint Compound, Former
Bank Back Offices
None Detected - Drywall Material
None Detected - Old Texture / Joint
Cmpd
None Detected - New Joint Compound
None Detected - New Texture
E32764 Drywall, Texture (Smooth) and Joint Compound, Former
Bank Back Offices
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32765 Drywall, Texture (Smooth) and Joint Compound, Former
Bank Back Offices
None Detected - Drywall Material
None Detected - Joint Compound
None Detected - Texture
E32766 Carpet Mastic (Yellow), Suite 150B None Detected - Yellow Mastic
None Detected - Leveling Compound
E32767 Carpet Mastic (Yellow), Suite 150B None Detected - Yellow Mastic
None Detected - Leveling Compound
E32768 Carpet Mastic (Yellow), Suite 150B None Detected - Yellow Mastic
None Detected - Leveling Compound
E32769 Drywall, Texture (Rolled) and Joint Compound, Suite 150B None Detected - Drywall Material
None Detected - Old Texture / Joint
Cmpd
None Detected - New Joint Compound
None Detected - New Texture
E32770 Drywall, Texture (Rolled) and Joint Compound, Suite 150B None Detected - Drywall Material
None Detected - Old Texture / Joint
Cmpd
None Detected - New Joint Compound
None Detected - New Texture
E32771 Drywall, Texture (Rolled) and Joint Compound, Suite 150B None Detected - Drywall Material
None Detected - Texture
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
E32772 Carpet Wall Base Mastic (Tan), Suite 150B None Detected - Tan Mastic
E32773 Carpet Wall Base Mastic (Tan), Suite 150B None Detected - Tan Mastic
E32774 Carpet Wall Base Mastic (Tan), Suite 150B None Detected - Tan Mastic
E32775 2' x 2' Lay-in Ceiling Tile (White, Smooth Finish), Suite
150B
None Detected - Acoustic Tile
E32776 2' x 2' Lay-in Ceiling Tile (White, Smooth Finish), Suite
150B
None Detected - Acoustic Tile
E32777 2' x 2' Lay-in Ceiling Tile (White, Smooth Finish), Suite
150B
None Detected - Acoustic Tile
E32778 HVAC Duct Mastic (Beige), Suite 150B None Detected - Foil Wrap
None Detected - Gray Mastic
E32779 HVAC Duct Mastic (Beige), Suite 150B None Detected - Foil Wrap
None Detected - Gray Mastic
E32780 HVAC Duct Mastic (Beige), Suite 150B None Detected - Foil Wrap
None Detected - Gray Mastic
E32781 Sink Undercoat (Beige), Suite 100A 5% Chrysotile - Sink Undercoating
E32782 Sink Undercoat (Beige), Suite 100A Not Analyzed - Positive Stop
E32783 Sink Undercoat (Beige), Suite 100A Not Analyzed - Positive Stop
E32784 Vinyl Wall Covering (Gray), Entry Foyer None Detected - Wall Covering
E32785 Vinyl Wall Covering (Gray), Main Lobby None Detected - Wall Covering
E32786 Vinyl Wall Covering (Gray), Main Lobby None Detected - Wall Covering
Project :
Project # :
Identification :
Test Method :
Farmer Environmental Group
Commercial Office Bldg, 1st Fl, 9696 Skillman, Dallas
5859.09 Metrocare
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 5/1/2025, one hundred fifty (150) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
25B-05162
04/30/2025 -
05/01/2025
05/08/2025
NVLAP Lab Code 102056-0
TDSHS License No. 300084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Amy Le, Debra O'Sullivan, Jacob Sutherland, Willie PruittAnalyst(s):
Lab Director : Bruce Crabb Approved Signatory :
Thank you for choosing Moody Labs
Lab Manager : Heather Lopez Approved Signatory :
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. The test report shall not be reproduced except in full without written approval of the laboratory. The results relate only to the items tested. These test results do not imply endorsement by NVLAP or any agency of the U.S.
Government. Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis…