MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°
APPLICABILITY CSI Critical Characteristic Affected?
Impact Statement Attached?
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
MED FORM 5-DEC-09 1401-R-E
AR 70-62 •11 May 2016 B 3150
Mar 21, 2018 7
IUID Parts Marking Updates to Chapter 1, Damper Assembly P/Ns 70106-08100-042, 70106-08100-043, 70106-08100-044 and 70106-08100-046
Technical
INTERIM USE OF THIS MEO IS AUTHORIZED
UNTIL AFFECTED DOCUMENT IS UPDATED.
MEO CHANGE TYPE
4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY
UH60 DAA
DMWR 1-1650-419, dtd 28 January 2011 TN 183771 3/8/2018
DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None
Changes based on revised Boilerplate marking requirements: Add Fabrication Note and Updates to IUID Query requirements. Implement MEOs B3150, B3151, B3152 and B1956 Chg1 cancellation concurrently.
SOUTH.JEPHRE
Y.LEE.123067790
Digitally signed by
SOUTH.JEPHREY.LEE.12306
77901 Date: 2018.03.09 07:54:10 -06'00'
NOLEN.OTIS.
F.1231157146
Digitally signed by
NOLEN.OTIS.F.1231157146
Date: 2018.03.08 13:06:26 -06'00'
Otis Nolen (Camber Corporation)
HORN.REINHOL
D.J.1087783495
Digitally signed by
HORN.REINHOLD.J.1087783
Date: 2018.03.09 07:56:44 -06'00'
Jephrey South Ron Horn PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT
CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
1-2 thru 1-4
1-6
1-7
1-7.4 thru 1-7.7
Figure 1-2
Figure 1-2
Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211
REPLACE paragraphs 1-7.4 thru 1-7.7 as shown on page 2 to 5 of this
MEO.
REPLACE Figure 1-2, Sheet 1 of 2 with figure found on page 6 of this
REPLACE Figure 1-2, Sheet 2 of 2 with figure found on page 7 of this
MED FORM 04 APR 2017
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016 2
1-7.4. Opportunistic Parts Marking (OPM) IUID Labels (Figure 1-3). In addition to the Damper Assemblies original nameplate, OPM IUID labels may be present. The OPM IUID label consists of one label. The label contains an ECC 200 compliant 2-D data matrix encoded with a Unique Identifier (UII) that is constructed/formatted IAW DoD Guide to Uniquely Identifying Items and MIL-STD-130 and is registered in the DoD IUID Registry.
1-7.5. Item Unique Identification (IUID) Data Plates (Figure 1-2). The IUID data plate provides MRI in an ECC 200 compliant 2-D data matrix that is encoded with a Construct 1 or 2 Unique Item Identifier (UII) using applicable Data Identifiers (DIs) or Text Element Identifiers (TEIs) as data qualifiers in accordance with MIL-STD-130 and is registered in the DoD IUID Registry.
a. Figure 1-2, Sheet 1 of 2, shows the IUID data plate format options for this component. The manufacturer IUID data plate format represents components originally UID-marked during production. The legacy IUID data plate formats represents components originally UID-marked post-production during an M&O event or in the field (commonly referred to as legacy components).
(1) Manufacturer IUID Data Plate. The IUID data plate may contain one or two 2-D data matrices. The
UID 2-D data matrix is encoded with a Construct 2 UII using DI or TEI data qualifiers 17V or CAG (manufacturer's CAGE code), 1P or PNO (original part number) and S or SEQ (manufacturer's serial number). A 30P or PNR (current part number) may also be encoded in a separate 2-D data matrix. as additional information. The 30P or PNR being the Sikorsky upon completion of the M&O event.
(2) Legacy IUID Data Plate. The data plate contains one 2-D data matrix encoded with a Construct 1 UII that uses TEIs, SPL (supplier's CAGE code) and UCN (supplier's unique component number) as data qualifiers. A PNR (current part number) is also encoded in a separate 2-D data matrix as additional information. The PNR being the Sikorsky upon completion of the M&O event.
1-7.6. IUID Data Plate Fabrication (Figure 1-2). The IUID data plate(s) are fabricated out of adhesive backed black matte polyacrylic material that meets the physical requirements per MIL-DTL-15024, Type L. The MRI and HRI shall be marked on the IUID data plate(s) using Laser Etch (App B, Table B-1), Thermal Transfer Printer or other acceptable marking technique in accordance with MIL-STD-130.
NOTE
Prior to fabrication of the IUID data plate(s), the DoD IUID Registry shall be queried per paragraph 3-7.1.
a. If the Damper Assembly is not registered in the DoD IUID Registry as determined by paragraph 3-7.1
(regardless of how the component is marked) and/or the UII data and component data does not match that in the registry record, IUID data plate(s) shall be fabricated in the format of Figure 1-2, Sheet 2 of 2, Option B.
(1) A Construct 1 UII shall be encoded into a 2-D data matrix using TEIs SPL (supplier's CAGE Code) and
UCN (supplier's Unique Component Number), IAW DoD Guide to Uniquely Identifying Items and/or MIL-STD-130 and registered in the DoD IUID Registry via the Wide Area Work Flow (WAWF) (App A, Websites) or The Army Maintenance Management System - Aviation/Maintenance Consolidated Database System (TAMMS-A/MCDS), Unique Identification (UID) database Damper Assembly. The UII can be constructed by the overhaul/repair facility using the overhaul facility's Enterprise Identifier (CAGE) SPL and UCN or the overhaul facility can generate an UII via AMCOM's TAMMS-A/MCDS, UID database (App A, Websites). The component's serially-managed manufacturer serial number shall not be used to develop the UII, but shall reside as HRI on the IUID data plate.
MED FORM 04 APR 2017
B 3150
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016 3
(2) The second 2-D data matrix shall be encoded with the current Sikorsky part number using TEI PNR (current Part Number), as the data qualifier. The PNR is the component's Sikorsky part number upon completion of the M&O event.
For components being marked by a Government Depot facility, registration shall occur prior to the component leaving the facility. For components being marked by other facilities, registration shall occur upon final delivery/DD250.
(3) The component shall be registered in the DoD IUID Registry via the WAWF (App A, Websites) in accordance with the data submission procedures at DPAP UID (App A, Websites). Additionally, the following shall be recorded in the "Mark Section" of the DoD IUID Registry in accordance with Guidelines for Registering Government Serialization, Type Designation and Ownership of Major End Items, Assemblies and Sub-assemblies and Capital Equipment:
Recorded as Set 1:
1. Manufacturer Serial Number (minus any spaces).
2. National Stock Number (with dashes).
3. Type Designation “UH-60” (with the dash and capital letters).
4. Service/Agency/Command “USARMY” (no space in all capital letters).
5. UII.
Recorded as Set 2:
Component Sikorsky Part Number and CAGE Code (if marked on the component and/or component original nameplate).
Recorded as Set 3 (If applicable):
Component Vendor Part Number and CAGE Code (if marked on the component and/or component original nameplate).
b. If the Damper Assembly has no IUID data plate(s) present; an UII is registered in the DoD IUID Registry
(whether or not an OPM IUID label is present) and the registry recorded data (paragraph 3-7.1) matches the data on the component, IUID data plate(s) shall be fabricated using the recorded data in the format of Options A or B, as applicable, Figure 2-1, Sheet 2 of 2. If present, the OPM IUID label shall be removed.
The label may be kept with the component documentation for reference only.
(1) The recorded UII (paragraph 3-7.1) shall be encoded into an IUID 2-D data matrix. M&O of the component shall not change the UII. For Option B: The component's manufacturer serial number from the original nameplate shall reside as HRI on the IUID data plate.
(2) The second 2-D data matrix shall be encoded with the current Sikorsky part number using DI (30P) or
TEI PNR (current Part Number) as the data qualifier. The (30P) or PNR is the component's Sikorsky part number upon completion of the M&O event.
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016 4
c. If the Damper Assembly has compliant IUID data plate(s) and the DoD IUID Registry record data matches data on the component (paragraph 3-7.1), but the IUID data plate(s) must be replaced due to damage and/or change to component data (e.g., part number roll, addition inspection code required, etc.), replacement IUID data plate(s) shall be fabricated in the format of Figure 1-2, Sheet 2 of 2, Options A or B, whichever is applicable.
(1) The recorded UII (paragraph 3-7.1) shall be encoded into an IUID 2-D data matrix. M&O of the component shall not change the UII. For Option B: The component's manufacturer serial number from the original nameplate shall reside as HRI on the IUID data plate.
(2) The second 2-D data matrix shall be encoded with the current Sikorsky part number using DI (30P) or
TEI PNR (current Part Number) as the data qualifier. The (30P) or PNR is the component's Sikorsky part number upon completion of the M&O event.
The verification for minimum print quality grade applies to compliant IUID data plates that have been removed and will be reapplied. For components having an compliant IUID data plate(s) that is installed (is not being removed during the M&O event), the IUID data plate(s) can remain on the component provided the 2-D data matrix passes a readability check per paragraph 1-7.7.g.
d. If the Damper Assembly has compliant IUID data plate(s); the UII is registered in the DoD IUID Registry and the registry record data matches the component data (paragraph 3-7.1); the IUID data plate(s) are undamaged; no data changes are required; the IUID data plate(s) can be reapplied to the component on which it was found at PSA, provided the MRI meets the verification requirement for minimum print quality grade per MIL-STD-130. If the 2-D data matrix does not meet the minimum grade requirements, replacement IUID data plate(s) shall be fabricated in the format of Figure 1-2, Sheet 2 of 2, Options A or B, whichever is applicable.
e. After fabricating IUID data plate(s), use a data matrix grader/verifier (App B, Table B-1) to verify that the
2-D data matrices have a minimum print quality grade per MIL-STD-130. Validate that data encoded in the 2-D data matrix matches HRI. If the 2-D matrix data failed minimum print quality grade, repeat the applicable marking process until the minimum print quality grade has been achieved.
1-7.7. IUID Data Plate Application.
Isopropyl alcohol is flammable and toxic to eyes, skin, and respiratory tract. Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well ventilated areas (or use approved respirator as determined by local safety/industrial hygiene personnel). Keep away from open flames, sparks, or other sources of ignition.
Quality control shall inspect the IUID data plate to ensure proper application and that the HRI and MRI match the previously recorded data for that component.
Allow TESA Tape (App C, item 73) stock or an equivalent to be conditioned to room temperature. Do not attempt to apply the IUID data plate when the component surface temperature is below 50°F.
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016 5
a. Clean the application area on the Damper Assembly using cloth (App C, item 2,) moistened with isopropyl alcohol (App C, item 33). Ensure all oils and solids are removed from application area.
b. Prior to application, ensure that the IUID data plate data is correct for the Damper Assembly to which it will be applied.
c. Peel liner from IUID data plate. Avoid adhesive contact with fingers. Place on the application area and firmly press from the middle out. Use a roller or clean cloth (App C, item 2) to firmly press the data plate down to ensure 100% contact and to remove any air bubbles.
Polyurethane coating is a carcinogenic risk. May cause birth defects People with chronic lung or breathing problems or persons that have reactions to isocyanates are not to use this product or be in the area where it is being used. Extreme overexposure could result in unconsciousness and possible death. It is an irritant to eyes, skin and respiratory tract. May cause sensitization and allergic respiratory and skin reactions.
Highly flammable. It is to use with mechanical ventilation / local exhaust. Use an approved respirator if exposure exceeds Permissible Exposure Limits and/or Threshold Limit Values. Wear approved gloves, skin, and eye protection. Avoid oxidizing agents and ignition sources.
d. Wipe surface of the IUID data plate with cloth (App C, item 2) moistened with isopropyl alcohol App C, item
33) to remove fingerprint oil, dust, lint, etc., and install over polyester over-laminate film (App C, item 74) or apply a flat clear top coat of epoxy (App C, item 75) with foam brush only (App C, item 76). The polyester over-laminate film or clear epoxy shall completely cover the IUID data plate and extend 1/16 inch to 1/8 inch beyond the data plate edges.
e. Seal over polyester over-laminate film edges with matte clear MIL-PRF-85285, Type I, Class polyurethane coating (App C, item 77).
f. Allow the clear epoxy or polyurethane coating to completely dry. Ensure IUID data plate or polyester over-laminate film edges have been secured completely.
g. Using a handheld reader (App B, Table B-1) or an equivalent; check readability of the 2-D data matrix on the IUID data plate by scanning two times. The time to decode any two scans shall be 15 seconds or less.
Replace any data matrix that does not meet the readability criteria. Validate that all pertinent information required in the 2-D data matrices, matches the information for that component.
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016
Figure 1-2. IUID Data Plates (Sheet 1 of 2).
MED FORM 04 APR 2017
Continuation Sheet
MEO NO.
PAGE of
MED FORM 15-DEC-09 1401-R-E
AR 70-62 •11 May 2016
Figure 1-2. IUID Data Plates (Sheet 2 of 2).
MED FORM 04 APR 2017
File details come from the government source that posted it. Updated .