MEO B1657.pdf
PDF 117 KB Posted
- Attached to
- MAINTENANCE AND OVERHAUL OF THE UH-60 DAMPENER
- Solicitation number
- W58RGZ-20-R-0095
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°
APPLICABILITY CSI Critical Characteristic Affected?
Impact Statement Attached?
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
MED FORM 5-DEC-09 1401-R-E
B 1657
Aug 8, 2014 2
Replacement of n-Propyl Bromide with Vertrel SDG in DMWR 1-1650-419, Damper Assembly, P/N 70106-08100-042, -043, -044, -046
Administrative
INTERIM USE OF THIS MEO IS AUTHORIZED
UNTIL AFFECTED DOCUMENT IS UPDATED.
MEO CHANGE TYPE
3) High - Has a business or process impactPRIORITY IMPLEMENTATION CATEGORY
UH60 DAA
DMWR 1-1650-419, dated 28 January 2011 TN 134633
DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None
Replacement of n-Propyl-Bromide with Vertrel SDG because of upcoming environmental regulatory changes.
TRAN.CHUCK
.B.1232211551
Digitally signed by
TRAN.CHUCK.B.1232211551
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=TRAN.CHUCK.B.1232211551 Date: 2014.08.07 16:31:06 -05'00'
GONZALEZ.JAC
OB.A.145582119
Digitally signed by
GONZALEZ.JACOB.A.1455821190
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=GONZALEZ.JACOB.A.1455821190 Date: 2014.08.07 12:32:18 -05'00'
Jacob Gonzalez
GRZELECKI.DAN
IEL.P.125929525
Digitally signed by
GRZELECKI.DANIEL.P.1259295250
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=GRZELECKI.DANIEL.P.1259295250 Date: 2014.08.07 17:01:14 -05'00'
Chuck B. Tran Daniel P. Grzelecki PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT
CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
h Replace n-Propyl-Bromide warning statement with following:
VERTREL SDG specialty fluid is combustible, toxic to eyes, skin, and respiratory tract, and decomposes into other hazardous products when exposed to extreme heat. Wear chemical protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Avoid breathing vapors or mist. Use only in well-ventilated areas. If ventilation is not adequate, use approved respirator as determined by local safety/industrial hygiene personnel. Keep away from open flames, sparks, or other sources of ignition. Refer to MSDS for specific requirements about components, reactivity, physical hazards, spill procedures, health hazards, first aid procedures, and
PPE.
Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211
MED FORM 26 JUN 2014
MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2) Continuation Sheet
MEO NO.
PAGE of
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
MED FORM 15-DEC-09 1401-R-E
3-20
3-21
C-4
3-10.5.2
3-10.5.2
Appendix C
Replace n-Propyl-Bromide warning statement with following:
VERTREL SDG specialty fluid is combustible, toxic to eyes, skin, and respiratory tract, and decomposes into other hazardous products when exposed to extreme heat. Wear chemical protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Avoid breathing vapors or mist. Use only in well-ventilated areas. If ventilation is not adequate, use approved respirator as determined by local safety/industrial hygiene personnel. Keep away from open flames, sparks, or other sources of ignition. Refer to MSDS for specific requirements about components, reactivity, physical hazards, spill procedures, health hazards, first aid procedures, and
PPE.
Within Paragraph: 3-10.5.2, Replace:
n-Propyl Bromide (App C, Item 54) with:
VERTREL SDG specialty fluid (App C, Item 54)
Replace:
54 6850-01-450-6162 Solvent, Cleaning Compound (n-Propyl 6 GL Bromide)
With:
54 6850-01-626-7714 VERTREL SDG specialty fluid DR
PN: M2S-SDGD (9V583)
MED FORM 26 JUN 2014
B 1657
Formatted Cont. Sheet
RDMR-AEM
MEMORANDUM FOR RECORD:
SUBJECT: Impact of AED Maintenance Engineering Order (MEO) on maintenance using ,affecting system:
Enclosed MEO is issued by this office and is provided as part of our Technical Data user support mission.
4. THIS MEO CHANGES THE FOLLOWING (Check all that apply):
1.
Consumables
Materials
Expendables
Repairable Bill of Materials (RBOM)Impact
3. PRIORITY IMPLEMENTATION CATEGORY :
6. :
. Point of contact for this action is
2. FOR AMCOM ACQUISITION CENTER USE ONLY:
This MEO was written as a request from a contractor/KO on an active M&O contract.
Request that MEO be transmitted to the contractor as soon as possible.
b.Items checked in this area are considered Normal Priority Implementation Category.
Illustrated Parts Breakdown Change Mandatory Replacement Part
TSO/TSN Change Configuration Change
Publication New Change
Hardware Tooling Equipment
New/Revised Procedure/Process
Process Improvement Project Inspection
Special Process Testing Cost Savings a.Items checked in this area are considered High Priority Implementation Category.
5. Reason(s) MEO Written:
Other
Other
B 1657
DMWR 1-1650-419, dated 28 January 2011 UH60 ROTOR H
B 1657
3) High - Has a business or process impact
Environmental Review
No
Daniel Grzelecki,RDMR-AEM,361-961-4062 or Jacob Gonzalez, jacob.a.gonzalez42.ctr@mail.mil, 361-961-4422
GONZALEZ.JACOB.A.1455
821190
Digitally signed by GONZALEZ.JACOB.A.1455821190 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=GONZALEZ.JACOB.A.1455821190 Date: 2014.08.07 12:32:00 -05'00'
File details come from the government source that posted it. Updated .