Marietta NatCem 859CM3021_CD95_Drawings 048-053.pdf
PDF 5 MB Posted
- Solicitation number
- 36C78623B0024
About this file
This document package includes mechanical drawings and specifications for improvements to the Marietta National Cemetery. The drawings show details for ductwork, piping, equipment, and notes for renovations to the lodge including new restrooms, committal shelter, and miscellaneous repairs. Mechanical items specified include supply and return air registers, exhaust grilles, fans, air handling units, condensing units, split systems, and ductless split systems. Manufacturers listed include Price, Nailor, Titus, Krueger, Greenheck, Cook, Twin City, DAIKIN, Trane and Mitsubishi. The related solicitation is for project 859CM3021 for improvements at Marietta National Cemetery and is issued by the Department of Veterans Affairs National Cemetery Administration.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2022, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
LODGE REHABILITATION, NEW
RESTROOMS, COMMITTAL SHELTER,
MISCELLANEOUS REPAIR ITEMS
MARIETTA NATIONAL CEMETERY
859CM3021
November 18, 2022
Bid Documents - Issued for Construction
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704-531-3000 Project 4773
MECHANICAL - NOTES, LEGEND
AND DRAWING INDEX
M-001
GAT NRB
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
TITLE
AutoCAD SHX Text MECHANICAL - NOTES, LEGEND, AND DRAWING INDEX MECHANICAL - DETAILS AND SCHEDULES MECHANICAL - BASEMENT AND 1ST FLOOR - DEMOLITION MECHANICAL - 2ND FLOOR, ATTIC AND ROOF - DEMOLITION MECHANICAL - BASEMENT AND 1ST FLOOR - NEW WORK MECHANICAL - 2ND FLOOR, ATTIC AND ROOF - NEW WORK
AutoCAD SHX Text
M-001 M-002 MD-111 MD-112 MH-111 MH-112
AutoCAD SHX Text
DIRECT EXPANSION
AutoCAD SHX Text
DX
AutoCAD SHX Text
TEMPERATURE SENSOR
AutoCAD SHX Text
UNDERWRITER'S LABORATORIES
AutoCAD SHX Text
UNLESS OTHERWISE NOTED
AutoCAD SHX Text
SYMBOL OR SYMMETRICAL
AutoCAD SHX Text
TEST, ADJUST, BALANCE
AutoCAD SHX Text
TRANSFER DUCT
AutoCAD SHX Text
SUPPLY REGISTER
AutoCAD SHX Text
STANDARD CUBIC FEET PER MINUTE
AutoCAD SHX Text
SHEET METAL AND AIR CONDITIONING
AutoCAD SHX Text
CONTRACTORS NATIONAL ASSOCIATION
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
WEATHER PROOF
AutoCAD SHX Text
VARIABLE FREQUENCY DRIVE
AutoCAD SHX Text
VARIABLE VOLUME
AutoCAD SHX Text
WET BULB TEMPERATURE
AutoCAD SHX Text Wb
AutoCAD SHX Text
GP
AutoCAD SHX Text
INSUL
AutoCAD SHX Text
INV
AutoCAD SHX Text
LAT
AutoCAD SHX Text
LB/HR
AutoCAD SHX Text
KW
AutoCAD SHX Text
HTG
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HOA
AutoCAD SHX Text
HORZ
AutoCAD SHX Text
H'STAT
AutoCAD SHX Text
HR
AutoCAD SHX Text
HP
AutoCAD SHX Text
HD
AutoCAD SHX Text
GPM
AutoCAD SHX Text
IN
AutoCAD SHX Text
ID
AutoCAD SHX Text
HEATING, VENTILATING, AND AIR CONDITIONING
AutoCAD SHX Text
INSIDE DIAMETER
AutoCAD SHX Text
LEAVING AIR TEMPERATURE
AutoCAD SHX Text
POUNDS PER HOUR
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
INVERT
AutoCAD SHX Text
KILOWATT
AutoCAD SHX Text
HEATING
AutoCAD SHX Text
INCH
AutoCAD SHX Text
HEAT DETECTOR
AutoCAD SHX Text
HAND-OFF-AUTOMATIC
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
GALLONS PER MINUTE
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
HUMIDISTAT
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
GUIDE POINT
AutoCAD SHX Text
WP
AutoCAD SHX Text
WG
AutoCAD SHX Text
WATER GAGE
AutoCAD SHX Text
GALV
AutoCAD SHX Text
GC
AutoCAD SHX Text
GAL
AutoCAD SHX Text
FT
AutoCAD SHX Text
FS
AutoCAD SHX Text
FPC
AutoCAD SHX Text
FPM
AutoCAD SHX Text
FPS
AutoCAD SHX Text
FOB
AutoCAD SHX Text
FP
AutoCAD SHX Text
FO
AutoCAD SHX Text
FLEX
AutoCAD SHX Text
FLG
AutoCAD SHX Text
FLR-FLR
AutoCAD SHX Text F&T
AutoCAD SHX Text F.D.
AutoCAD SHX Text
EQUIP
AutoCAD SHX Text
ESP
AutoCAD SHX Text
EWT
AutoCAD SHX Text
EXH
AutoCAD SHX Text
ER
AutoCAD SHX Text
EC
AutoCAD SHX Text
EFF
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
EL
AutoCAD SHX Text
EQ
AutoCAD SHX Text
EAT
AutoCAD SHX Text
EA
AutoCAD SHX Text F
AutoCAD SHX Text
EJ
AutoCAD SHX Text
FIRE PROTECTION CONTRACTOR
AutoCAD SHX Text
FEET PER SECOND
AutoCAD SHX Text
FLOW SWITCH/SENSOR
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
FEET
AutoCAD SHX Text
GALVANIZED
AutoCAD SHX Text
GALLON(S)
AutoCAD SHX Text
FLOOR TO FLOOR HEIGHT
AutoCAD SHX Text
FIRE PROTECTI0N
AutoCAD SHX Text
FLAT ON BOTTOM
AutoCAD SHX Text
FLANGE
AutoCAD SHX Text
FLAT OVAL
AutoCAD SHX Text
FLEX
AutoCAD SHX Text
VERT
AutoCAD SHX Text W/
AutoCAD SHX Text W/O
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VTR
AutoCAD SHX Text
VOL
AutoCAD SHX Text
VP
AutoCAD SHX Text
VLV
AutoCAD SHX Text
WITHOUT
AutoCAD SHX Text
WITH
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
VOLUME
AutoCAD SHX Text
VENT POINT
AutoCAD SHX Text
VALVE
AutoCAD SHX Text
THRU
AutoCAD SHX Text
T'STAT
AutoCAD SHX Text
UL
AutoCAD SHX Text
VAV
AutoCAD SHX Text
UON
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TOP
AutoCAD SHX Text
TS
AutoCAD SHX Text
TOS
AutoCAD SHX Text
TOD
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
THROUGH
AutoCAD SHX Text
TOP OF DUCT
AutoCAD SHX Text
TOP OF STEEL
AutoCAD SHX Text
TOP OF PIPE
AutoCAD SHX Text
EXHAUST REGISTER
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
ENTERING WATER TEMPERATURE
AutoCAD SHX Text
FLOAT AND THERMOSTATIC
AutoCAD SHX Text
FAHRENHEIT
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
EXHAUST
AutoCAD SHX Text
ENTERING AIR TEMPERATURE
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
EQUAL
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
EFFICIENCY
AutoCAD SHX Text
SPRINKLER
AutoCAD SHX Text
SPR
AutoCAD SHX Text
STRUCT
AutoCAD SHX Text
TAB
AutoCAD SHX Text T/D
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SYS
AutoCAD SHX Text
STL
AutoCAD SHX Text
STM
AutoCAD SHX Text
SR
AutoCAD SHX Text
SQ
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEM
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
STEAM
AutoCAD SHX Text
SQUARE
AutoCAD SHX Text
SMACNA
AutoCAD SHX Text
SPEC
AutoCAD SHX Text
SECT
AutoCAD SHX Text
SCFM
AutoCAD SHX Text
SP
AutoCAD SHX Text
SCH
AutoCAD SHX Text
SA
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SPECIFICATION
AutoCAD SHX Text
SCHEDULE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
LOW SIDE WALL EXHAUST REGISTER
AutoCAD SHX Text
LEAVING WATER TEMPERATURE
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
POUNDS PER SQUARE INCH ABSOLUTE
AutoCAD SHX Text
POUNDS PER SQUARE INCH GAGE
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text
POLYVINYL CHLORIDE
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
POUNDS PER SQUARE INCH
AutoCAD SHX Text
PRESSURE REDUCING STATION
AutoCAD SHX Text
PLUMBING CONTRACTOR
AutoCAD SHX Text
OUTSIDE DIAMETER
AutoCAD SHX Text
MOTOR OPERATED DAMPER
AutoCAD SHX Text
NATIONAL ELECTRIC CODE
AutoCAD SHX Text
NATIONAL ELECTRICAL MANUFACTURER'S
AutoCAD SHX Text
NATIONAL FIRE PROTECTION ASSOCIATION
AutoCAD SHX Text
NET POSITIVE SUCTION HEAD
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NORMALLY OPEN
AutoCAD SHX Text
NORMALLY CLOSED
AutoCAD SHX Text
MECHANICAL CONTRACTOR
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
MANUAL DAMPER
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MFR
AutoCAD SHX Text
ARCH
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
DWG
AutoCAD SHX Text
DWV
AutoCAD SHX Text Db
AutoCAD SHX Text
DEG(%%D)
AutoCAD SHX Text
DPR
AutoCAD SHX Text
DTF
AutoCAD SHX Text
DP
AutoCAD SHX Text
DN
AutoCAD SHX Text
CU.FT.
AutoCAD SHX Text
CTR
AutoCAD SHX Text
CU.YD.
AutoCAD SHX Text
DD
AutoCAD SHX Text
CU
AutoCAD SHX Text
CONN
AutoCAD SHX Text
CONT
AutoCAD SHX Text
CONTR
AutoCAD SHX Text
COP
AutoCAD SHX Text
CONST
AutoCAD SHX Text
COORD
AutoCAD SHX Text
CFH
AutoCAD SHX Text
CFM
AutoCAD SHX Text
CLG
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CO
AutoCAD SHX Text
ASHRAE
AutoCAD SHX Text
BFP
AutoCAD SHX Text
BDD
AutoCAD SHX Text
ASME
AutoCAD SHX Text
BHP
AutoCAD SHX Text
AUTO
AutoCAD SHX Text
BOP
AutoCAD SHX Text
BOD
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
BTU
AutoCAD SHX Text
BOS
AutoCAD SHX Text
BV
AutoCAD SHX Text C
AutoCAD SHX Text
CUBIC YARD
AutoCAD SHX Text
DRAIN, WASTE, AND VENT
AutoCAD SHX Text
DOWN THRU FLOOR
AutoCAD SHX Text
DUCT MOUNTED SMOKE DETECTOR
AutoCAD SHX Text
DRAIN POINT
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
DRY BULB TEMPERATURE
AutoCAD SHX Text
DEGREE(S)
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
COEFFICIENT OF PERFORMANCE
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
COPPER
AutoCAD SHX Text
CUBIC FEET
AutoCAD SHX Text
CENTER
AutoCAD SHX Text
CONNECTION
AutoCAD SHX Text
CONTINUATION
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
COORDINATE
AutoCAD SHX Text
RECIRC
AutoCAD SHX Text
REINF
AutoCAD SHX Text
REQD
AutoCAD SHX Text
RH
AutoCAD SHX Text
RPM
AutoCAD SHX Text
RM
AutoCAD SHX Text
REV
AutoCAD SHX Text
RD
AutoCAD SHX Text
RA
AutoCAD SHX Text
RCP
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
RECIRCULATING
AutoCAD SHX Text
REINFORCING
AutoCAD SHX Text
ROUND
AutoCAD SHX Text
PLBG
AutoCAD SHX Text
PSIG
AutoCAD SHX Text
QTY
AutoCAD SHX Text
PVC
AutoCAD SHX Text
PSI
AutoCAD SHX Text
PSIA
AutoCAD SHX Text
PRV
AutoCAD SHX Text
PRS
AutoCAD SHX Text
PL
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
PILOT LIGHT
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AutoCAD SHX Text
CONSTANT VOLUME
AutoCAD SHX Text
CUBIC FEET PER HOUR
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
BRITISH THERMAL UNIT PER HOUR
AutoCAD SHX Text
BRITISH THERMAL UNIT
AutoCAD SHX Text
BOTTOM OF STEEL
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
BACKFLOW PREVENTER
AutoCAD SHX Text
BOTTOM OF PIPE
AutoCAD SHX Text
BOTTOM OF DUCT
AutoCAD SHX Text
BACKDRAFT DAMPER
AutoCAD SHX Text
AND AIR CONDITIONING ENGINEERS
AutoCAD SHX Text
BOILER HORSEPOWER OR BRAKE HORSEPOWER
AutoCAD SHX Text
AUTOMATIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
OPNG
AutoCAD SHX Text
NPSH
AutoCAD SHX Text
OA
AutoCAD SHX Text P.C.
AutoCAD SHX Text
OD
AutoCAD SHX Text
OC
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NO
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
OPENING
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NFPA
AutoCAD SHX Text
NEMA
AutoCAD SHX Text
NC
AutoCAD SHX Text
NEC
AutoCAD SHX Text
MOD
AutoCAD SHX Text
MTD
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MH
AutoCAD SHX Text
ASSOCIATION
AutoCAD SHX Text
MOUNTED
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
AD
AutoCAD SHX Text
AFMS
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AC/HR
AutoCAD SHX Text
AP
AutoCAD SHX Text
ANSI
AutoCAD SHX Text
APPROX
AutoCAD SHX Text
AMCA
AutoCAD SHX Text
ABV.CLG.
AutoCAD SHX Text
AutoCAD SHX Text %%c
AutoCAD SHX Text
AIR MOVEMENT AND CONTROL ASSOCIATION
AutoCAD SHX Text
AMERICAN NATIONAL STANTDARDS INSTITUTE
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
ANCHOR POINT
AutoCAD SHX Text
AIR FLOW MONITORING STATION
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AIR CHANGES PER HOUR
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
APPROXIMATE
AutoCAD SHX Text
ABOVE CEILING
AutoCAD SHX Text
POUNDS OR NUMBER
AutoCAD SHX Text
ROUND, DIAMETER OR PHASE
AutoCAD SHX Text
LSWER
AutoCAD SHX Text
MEZZ
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MFG
AutoCAD SHX Text
MD
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MC
AutoCAD SHX Text
MBH
AutoCAD SHX Text
MAV
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
MANUFACTURING
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text BTUH x 1000
AutoCAD SHX Text
LF
AutoCAD SHX Text
LP
AutoCAD SHX Text
LWT
AutoCAD SHX Text
LINEAR FEET
AutoCAD SHX Text
LOW PRESSURE
AutoCAD SHX Text S/S
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
RVNR
AutoCAD SHX Text
REDUCED VOLTAGE, NON-REVERSING, MAGNETIC
AutoCAD SHX Text
FVNR
AutoCAD SHX Text
FULL VOLTAGE, NON-REVERSING, MAGNETIC
AutoCAD SHX Text
MRS
AutoCAD SHX Text
MOTOR RATED SWITCH
AutoCAD SHX Text W
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
ACU-1
AutoCAD SHX Text
AIR CONDITIONING UNIT & TAG
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
AIR HANDLING UNIT & TAG
AutoCAD SHX Text
CC
AutoCAD SHX Text
COOLING COIL
AutoCAD SHX Text
DB
AutoCAD SHX Text
DECIBELS
AutoCAD SHX Text Dp
AutoCAD SHX Text
DEWPOINT TEMPERATURE
AutoCAD SHX Text
EDH
AutoCAD SHX Text
ELECTRIC COIL DUCT HEATER
AutoCAD SHX Text
CU-1
AutoCAD SHX Text
CONDENSING UNIT & TAG
AutoCAD SHX Text
EER
AutoCAD SHX Text
ENERGY EFFICIENCY RATIO
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
EXHAUST FAN & TAG
AutoCAD SHX Text E or EX.
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
NOT ALL ABBREVIATIONS SHOWN IN THIS LIST WERE UTILIZED FOR THIS PROJECT.
AutoCAD SHX Text
AMERICAN SOCIETY OF HEATING, REFRIGERATING,
AutoCAD SHX Text
AFLD
AutoCAD SHX Text
AUTOMATIC FLOW LIMITING DEVICE
AutoCAD SHX Text
NOT APPLICABLE
AutoCAD SHX Text N/A
AutoCAD SHX Text A. ALL DUCTS, PIPE, AND EQUIPMENT SHALL BE LATERALLY RESTRAINED TO COMPLY ALL DUCTS, PIPE, AND EQUIPMENT SHALL BE LATERALLY RESTRAINED TO COMPLY WITH STATE BUILDING CODE. B. BEFORE FABRICATING ANY SHEET METAL DUCTWORK, COORDINATE LOCATION AND BEFORE FABRICATING ANY SHEET METAL DUCTWORK, COORDINATE LOCATION AND SIZE WITH SPRINKLER & PLUMBING PIPING, CONDUITS, LIGHT FIXTURES, STRUCTURAL, ETC. PLANS ARE SCHEMATIC AND ARE NOT SHOP DRAWINGS. SUBMIT DUCTWORK COORDINATION DRAWINGS, AS SPECIFIED. C. BEFORE SUBMITTING SHOP DRAWINGS, COORDINATE VOLTAGES AVAILABLE FOR BEFORE SUBMITTING SHOP DRAWINGS, COORDINATE VOLTAGES AVAILABLE FOR MECHANICAL EQUIPMENT AND PROVISION OF ALL STARTERS AND DISCONNECT SWITCHES WITH ELECTRICAL CONTRACTOR. D. MECHANICAL CONTRACTOR SHALL MAKE PROVISIONS FOR PROVIDING A MECHANICAL CONTRACTOR SHALL MAKE PROVISIONS FOR PROVIDING A CONDENSATE DRAIN TRAP A MINIMUM OF 4" DEEP OR " PLUS THE STATIC 12" PLUS THE STATIC PRESSURE OF THE UNIT SUPPLY FAN. E. ALL EQUIPMENT SHALL BE U.L. LISTED. ALL EQUIPMENT SHALL BE U.L. LISTED. F. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT; THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT; PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT AND WIRE VFD, UNLESS OTHERWISE NOTED. UNLESS OTHERWISE NOTED. G. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE ARCHITECT/ENGINEER WITHOUT ADDITIONAL COMPENSATION TO THE CONTRACTOR. H. SMOKE DETECTORS SHALL BE FURNISHED BY ELECTRICAL CONTRACTOR AND SMOKE DETECTORS SHALL BE FURNISHED BY ELECTRICAL CONTRACTOR AND INSTALLED BY THE MECHANICAL CONTRACTOR. PROVIDE DUCT ACCESS DOOR AT EACH DETECTOR. INSTALL DETECTORS IN COMPLETE ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. I. MECHANICAL CONTRACTOR SHALL COORDINATE ROUTING OF DUCTWORK TO MECHANICAL CONTRACTOR SHALL COORDINATE ROUTING OF DUCTWORK TO ENSURE DUCTWORK DOES NOT PASS OVER ELECTRICAL PANELS. J. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE SCALE, WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY. K. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE OWNERS ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE OWNERS REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK. THIS TIME LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL BE AT THE OWNERS DISCRETION. L. PROVIDE ESCUTCHEON PLATES WHERE DUCTS PENETRATE CEILINGS OR WALLS IN PROVIDE ESCUTCHEON PLATES WHERE DUCTS PENETRATE CEILINGS OR WALLS IN AREAS EXPOSED TO VIEW. ESCUTCHEONS FOR DUCTS SHALL BE CONSTRUCTED OF SAME MATERIAL AS DUCT. PIPE ESCUTCHEONS SHALL BE CHROME-PLATED BRASS. M. LEAVE A MINIMUM CLEARANCE OF 2 INCHES ABOVE DUCTS INSTALLED IN RATED LEAVE A MINIMUM CLEARANCE OF 2 INCHES ABOVE DUCTS INSTALLED IN RATED PARTITIONS TO ALLOW SPACE FOR THE GENERAL CONTRACTOR TO SEAL THE WALL ABOVE THE DUCTS. DO NOT INSTALL FLEXIBLE DUCT THROUGH RATED WALLS, BARRIERS OR PARTITIONS. N. PROVIDE REMOVABLE ACCESS DOORS AT ALL MOTOR OPERATED DAMPERS, DUCT PROVIDE REMOVABLE ACCESS DOORS AT ALL MOTOR OPERATED DAMPERS, DUCT COILS, SMOKE DETECTORS, AND SIMILAR ITEMS REQUIRING MAINTENANCE OR ADJUSTMENT.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
SIDEWALL RETURN REGISTER
AutoCAD SHX Text
CEILING RETURN GRILLE/
AutoCAD SHX Text
SIDEWALL EXHAUST REGISTER
AutoCAD SHX Text
CEILING EXHAUST GRILLE/
AutoCAD SHX Text
DUCTWORK W/O DUCTLINER
AutoCAD SHX Text
SIDEWALL SUPPLY REGISTER
AutoCAD SHX Text
CEILING SUPPLY DIFFUSER/
AutoCAD SHX Text
MANUAL DAMPER
AutoCAD SHX Text
DOUBLE LINE
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OVAL TRANSITION
AutoCAD SHX Text
SQUARE TO ROUND/
AutoCAD SHX Text
CONICAL TAKEOFF
AutoCAD SHX Text
RECTANGULAR DUCT
AutoCAD SHX Text
MITERED TAKEOFF
AutoCAD SHX Text
(SEE SCH)
AutoCAD SHX Text
(SEE SCH)
AutoCAD SHX Text
REGISTER (SEE SCH)
AutoCAD SHX Text
DOUBLE LINE
AutoCAD SHX Text
DUCTWORK
AutoCAD SHX Text
(SEE SCH)
AutoCAD SHX Text
REGISTER (SEE SCH)
AutoCAD SHX Text
REGISTER (SEE SCH)
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text V
AutoCAD SHX Text
VENT
AutoCAD SHX Text R
AutoCAD SHX Text
REFRIGERANT
AutoCAD SHX Text D
AutoCAD SHX Text
DRAIN
AutoCAD SHX Text
PIPING
AutoCAD SHX Text
EXHAUST DUCT UP
AutoCAD SHX Text
SUPPLY AND RETURN SIMILAR
AutoCAD SHX Text
RETURN DUCT DOWN
AutoCAD SHX Text
SUPPLY AND EXHAUST SIMILAR
AutoCAD SHX Text
SUPPLY DUCT, UP THROUGH ROOF
AutoCAD SHX Text
RETURN AND EXHAUST SIMILAR
AutoCAD SHX Text
DRAWING NUMBER WHERE SECTION
AutoCAD SHX Text
DIRECTION OF AIR FLOW
AutoCAD SHX Text
CONNECT TO EXISTING SYMBOL
AutoCAD SHX Text 12x10
AutoCAD SHX Text
DUCT SYMBOL: RECTANGULAR
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
IS LOCATED
AutoCAD SHX Text T
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
SECTION NUMBER
AutoCAD SHX Text
MISCELLANEOUS
AutoCAD SHX Text
CFM
AutoCAD SHX Text
ARROW AND CFM
AutoCAD SHX Text
DUCT SYMBOL: ROUND
AutoCAD SHX Text 12%%c
AutoCAD SHX Text
PIPE UP
AutoCAD SHX Text
PIPE DOWN
AutoCAD SHX Text
ACCESSORIES
AutoCAD SHX Text
DIRECTION OF FLOW
AutoCAD SHX Text
AutoCAD SHX Text M4
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
DRAWING NUMBER WHERE SHOWN
AutoCAD SHX Text M4.1
AutoCAD SHX Text
AutoCAD SHX Text
TO REMAIN
AutoCAD SHX Text
TO BE REMOVED
AutoCAD SHX Text
EXISTING DUCT
AutoCAD SHX Text
EXISTING EQUIPMENT
AutoCAD SHX Text
TO REMAIN
AutoCAD SHX Text
TO BE REMOVED
AutoCAD SHX Text
EXISTING PIPING
AutoCAD SHX Text
EXISTING PIPING
AutoCAD SHX Text D
AutoCAD SHX Text
TO REMAIN
AutoCAD SHX Text
EXISTING CONDENSATE DRAIN
AutoCAD SHX Text
TO BE REMOVED
AutoCAD SHX Text
EXISTING EQUIPMENT
AutoCAD SHX Text
TO REMAIN
AutoCAD SHX Text
EXISTING DUCT
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
NEW EQUIPMENT
AutoCAD SHX Text
NEW PIPING
AutoCAD SHX Text
NEW DUCTWORK
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text R
AutoCAD SHX Text
REFRIGERANT
AutoCAD SHX Text V
AutoCAD SHX Text
VENT
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2022, Walker Federal Services, LLC
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
WFS
LODGE REHABILITATION, NEW
RESTROOMS, COMMITTAL SHELTER,
MISCELLANEOUS REPAIR ITEMS
MARIETTA NATIONAL CEMETERY
859CM3021
November 18, 2022
Bid Documents - Issued for Construction
5838 Monroe Road, Suite 100 Charlotte, NC 28212
704-531-3000 Project 4773
MECHANICAL - DETAILS AND
SCHEDULES
M-002
GAT NRB
24"
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text REGISTER SIZE 24"x24"
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
136-210 CFM 8" ROUND NECK
AutoCAD SHX Text
0-135 CFM 6" ROUND NECK
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
211-325 CFM 10" ROUND NECK
AutoCAD SHX Text
326-475 CFM 12" ROUND NECK
AutoCAD SHX Text
651-840 CFM 16" ROUND NECK
AutoCAD SHX Text 841-2000 CFM 22"x22" NECK
AutoCAD SHX Text
476-650 CFM 14" ROUND NECK
AutoCAD SHX Text
CFM
AutoCAD SHX Text A
AutoCAD SHX Text
CFM
AutoCAD SHX Text B
AutoCAD SHX Text
CFM
AutoCAD SHX Text C
AutoCAD SHX Text
CFM
AutoCAD SHX Text D
AutoCAD SHX Text
CFM
AutoCAD SHX Text E
AutoCAD SHX Text
CFM
AutoCAD SHX Text F
AutoCAD SHX Text
CFM
AutoCAD SHX Text G
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PERFORATED EXHAUST REGISTERS
AutoCAD SHX Text NOTES: : 1. ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE. 2. REGISTERS LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE REGISTERS LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE MOUNTED FRAMES.
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text REGISTER SIZE 24"x24"
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
PERFORATED RETURN REGISTERS
AutoCAD SHX Text
136-210 CFM 8" ROUND NECK
AutoCAD SHX Text
0-135 CFM 6" ROUND NECK
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
211-325 CFM 10" ROUND NECK
AutoCAD SHX Text
326-475 CFM 12" ROUND NECK
AutoCAD SHX Text
651-840 CFM 16" ROUND NECK
AutoCAD SHX Text 841-2000 CFM 22"x22" NECK
AutoCAD SHX Text
476-650 CFM 14" ROUND NECK
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text NOTES: : 1. ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE. 2. GRILLES LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE MOUNTED GRILLES LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE MOUNTED FRAMES.
AutoCAD SHX Text
SERVICES
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CFM
AutoCAD SHX Text
FAN SCHEDULE
AutoCAD SHX Text
STARTER
AutoCAD SHX Text
DISC. SW.
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
FAN NO.
AutoCAD SHX Text
FAN RPM
AutoCAD SHX Text
EXTERNAL STATIC PRESS. IN W.G.
AutoCAD SHX Text
FAN WHEEL TYPE
AutoCAD SHX Text
MOTOR HP/VOLT/HZ/ PHASE
AutoCAD SHX Text
DRIVE TYPE
AutoCAD SHX Text
FAN TYPE
AutoCAD SHX Text
CONTROL SWITCH & INTERLOCK TYPE
AutoCAD SHX Text
MFG. & MODEL # DESIGN BASED ON
AutoCAD SHX Text 12"x12" REGISTER
AutoCAD SHX Text
CFM
AutoCAD SHX Text H
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
0-135 CFM 6"%%C NECK
AutoCAD SHX Text
ATTIC 301
AutoCAD SHX Text
AutoCAD SHX Text 1,261
AutoCAD SHX Text 0.5
AutoCAD SHX Text
DIRECT
AutoCAD SHX Text
INLINE
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
GREENHECK CSP-A390-VG
AutoCAD SHX Text
MC
AutoCAD SHX Text
EC
AutoCAD SHX Text 0.05/115/60/1
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
CFM RANGE, FACE SIZE, & NECK SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
LOUVERED SUPPLY DIFFUSER
AutoCAD SHX Text 136-210 CFM 9"x9" FACE 8" NECK
AutoCAD SHX Text 0-135 CFM 6"x6" FACE 6"%%C NECK
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text 211-325 CFM 12"x12" FACE 10" NECK
AutoCAD SHX Text 326-475 CFM 12"x12" FACE 12" NECK
AutoCAD SHX Text 476-650 CFM 15"x15" FACE 14" NECK
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text 650-840 CFM 18"x18" FACE 16" NECK
AutoCAD SHX Text
841-1125 CFM 18"X18" FACE & NECK
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text NOTES: : 1. ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE. 2. DIFFUSERS LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE DIFFUSERS LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE MOUNTED FRAMES. 3. PROVIDE SR MODEL ROUND NECK ADAPTER.PROVIDE SR MODEL ROUND NECK ADAPTER.
AutoCAD SHX Text TYPICAL MODULE SIZE - 24"x24"
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
0-150 CFM 12"X12" FACE 6" NECK
AutoCAD SHX Text
PRICE SMD
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text
PRIME CONSULTANT
AutoCAD SHX Text
CONSULTANTS
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SIDEWALL RETURN REGISTER
AutoCAD SHX Text 111-250 CFM 10"x8"
AutoCAD SHX Text 0-110 CFM 8"x4"
AutoCAD SHX Text 251-480 CFM 14"x10"
AutoCAD SHX Text 481-650 CFM 18"x12"
AutoCAD SHX Text 651-835 CFM 20"x14"
AutoCAD SHX Text 836-1400 CFM 24"x18"
AutoCAD SHX Text
PRICE 530/630
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
PRICE 530/630
AutoCAD SHX Text
PRICE 530/630
AutoCAD SHX Text
PRICE 530/630
AutoCAD SHX Text
PRICE 530/630
AutoCAD SHX Text
PRICE 530/630
AutoCAD SHX Text ACCEPTABLE MANUFACTURERS: PRICE, NAILOR, TITUS & KRUEGER. SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
AutoCAD SHX Text NOTES: : 1. DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION. 2. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI-BLADE DAMPERS & ROUND DAMPERS.
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
DAMPER BLADE
AutoCAD SHX Text 1/8" [6mm] CLEARANCE ALL AROUND
AutoCAD SHX Text
OUTSIDE END BEARING
AutoCAD SHX Text
INSIDE END BEARING
AutoCAD SHX Text
HANDLE WITH LOCKING QUADRANT
AutoCAD SHX Text
INSULATION STAND-OFF
AutoCAD SHX Text 1/2" [15mm] ROUND ROD PIN
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
STIFFEN BLADE AS REQUIRED
AutoCAD SHX Text
SIDE ELEVATION
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
VOLUME DAMPER DETAIL
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SIDE VIEW
AutoCAD SHX Text
NTS
AutoCAD SHX Text
ELEVATION CHANGE - OGEE TRANSITION DETAIL
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text R=1.5D
AutoCAD SHX Text D
AutoCAD SHX Text NOTES: : 1. CHANGES IN DUCTWORK ELEVATION SHALL BE ACCOMPLISHED BY UTILIZING CHANGES IN DUCTWORK ELEVATION SHALL BE ACCOMPLISHED BY UTILIZING RADIUS ELBOW TRANSITIONS EQUAL TO NO LESS THAN R=1.5D. IN ORDER TO MINIMIZE DUCT STATIC PRESSURE LOSSES. 2. ELEVATION TRANSITION ARROW INDICATING UP OR DOWN (DN) IS SHOWN ELEVATION TRANSITION ARROW INDICATING UP OR DOWN (DN) IS SHOWN WITH RESPECT TO AIRFLOW DIRECTION.
AutoCAD SHX Text
DN
AutoCAD SHX Text R
AutoCAD SHX Text
RECTANGULAR SHEETMETAL ELBOWS
AutoCAD SHX Text
TYPE RE 2 SQUARE THROAT ELBOW WITH VANES
AutoCAD SHX Text
TYPE RE 1 RADIUS ELBOW
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
BRANCH DUCT
AutoCAD SHX Text
BRANCH DUCTWORK TAKEOFFS
AutoCAD SHX Text
MAIN EXHAUST OR RETURN AIR FLOW
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NOTE: : ALL BRANCH TAKEOFFS SHALL BE 45°, CONICAL OR BELLMOUTH TYPE.
AutoCAD SHX Text
AIR FLOW
AutoCAD SHX Text
BRANCH DUCT
AutoCAD SHX Text
MAIN SUPPLY AIR FLOW
AutoCAD SHX Text
VOLUME DAMPER (REFER TO VOLUME DAMPER DETAIL).
AutoCAD SHX Text
VOLUME DAMPER (REFER TO VOLUME DAMPER DETAIL).
AutoCAD SHX Text 48"
AutoCAD SHX Text 2"
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
DEVICES BY ELECTRICAL
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
THERMOSTAT ALIGNMENT
AutoCAD SHX Text NOTES: : 1. PROPERLY COORDINATE DEVICE LOCATION TO ALIGN VERTICALLY.PROPERLY COORDINATE DEVICE LOCATION TO ALIGN VERTICALLY.
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
DUCT
AutoCAD SHX Text MANUAL VOLUME DAMPER WITH QUADRANT LOCKING DEVICE, WITH STANDOFF RUSKIN MODEL MDRS25 OR EQUAL.
AutoCAD SHX Text EXTEND TAP AS REQ.D TO ALLOW MAX 5' LENGTH OF FLEX DUCT BETWEEN CONNECTION AND DIFFUSER
AutoCAD SHX Text
FLEX DUCT WITH EXTERNAL BLANKET INSULATION (TYP)
AutoCAD SHX Text
CONNECTIONS BETWEEN LOW PRESSURE DUCT AND AIR DISTRIBUTION DEVICE
AutoCAD SHX Text
AutoCAD SHX Text NOTES: : 1. ONLY ONE 90 TURN ALLOWED IN FLEX DUCT. DUCT MUST BE PROPERLY ONLY ONE 90° TURN ALLOWED IN FLEX DUCT. DUCT MUST BE PROPERLYSUPPORTED TO PREVENT KINKING. 2. IF ADDITIONAL 90 TURNS ARE REQD TO CONNECT OUTLET TO DIFFUSER, IF ADDITIONAL 90° TURNS ARE REQD TO CONNECT OUTLET TO DIFFUSER,EXTEND TAP AND PROVIDE EXTERNALLY INSULATED SHEET METAL ELLS AS REQD.
AutoCAD SHX Text
SEAL WITH DRAW BAND AT TAP CONNECTION AND DIFFUSER/FIXTURE
AutoCAD SHX Text
SEAL INSULATION TO DUCT WITH CAULKING
AutoCAD SHX Text
AIR DISTRIBUTION DEVICE
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SPIN IN COLLAR.
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM EXHAUST FAN
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
FLASHING AND COUNTER FLASHING BY M.C.
AutoCAD SHX Text
FLEXDUCT
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
SEQUENCE OF OPERATIONS
AutoCAD SHX Text
AutoCAD SHX Text
DUCT SUSPENSION DETAIL
AutoCAD SHX Text
NUTS
AutoCAD SHX Text
ROUND BAR
AutoCAD SHX Text
EXPANSION SHIELD WITH BOLT
AutoCAD SHX Text
WOODEN TRUSS (VERIFY STRUCTURAL)
AutoCAD SHX Text
STRUCTURE (VERIFY STRUCTURAL)
AutoCAD SHX Text
NUT
AutoCAD SHX Text
DUCT INSULATION
AutoCAD SHX Text
SHEET METAL DUCT
AutoCAD SHX Text
ANGULAR BAR
AutoCAD SHX Text 211-350 CFM 12"x12" 10" NECK
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text
PRICE PDDR
AutoCAD SHX Text
RESTRM 104, RESTRM 105, JAN. CLOS 108, BATHRM 209
AutoCAD SHX Text
NTS
AutoCAD SHX Text
AutoCAD SHX Text
GAS FURNACE
AutoCAD SHX Text
SLOPED ROOF
AutoCAD SHX Text
AT LEAST 6' FROM PARAPET OR ADJOINING BUILDING
AutoCAD SHX Text
REFER TO PLUMBING DRAWINGS FOR GAS PIPING
AutoCAD SHX Text
3" CATEGORY III VENT PIPE
AutoCAD SHX Text
AIR HANDLING UNIT DETAIL
AutoCAD SHX Text VERTICAL FLUE EXTENSION MUST BE 6" HIGHER THAN ANTICIPATED SNOW DEPTH BUT NO LESS THAN 2' ABOVE THE ROOF.
AutoCAD SHX Text APPROVED CLEARANCE THIMBLE IS REQUIRED WHEN FLUE PIPE EXTENDS THROUGH COMBUSTIBLE MATERIALS. FOLLOW THE REQUIREMENTS OF THE THIMBLE AND/OR THE VENT PIPE MANUFACTURER
AutoCAD SHX Text
ROOF FLASHING
AutoCAD SHX Text
MINIMUM OUTDOOR AIR REQUIREMENTS
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
AREA
AutoCAD SHX Text
SQ. FT.
AutoCAD SHX Text
OCCUPANT LOAD
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
(PEOPLE/1000 SQ FT)
AutoCAD SHX Text
OUTDOOR AIR
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
(CFM/PERSON)
AutoCAD SHX Text
MINIMUM OUTDOOR
AutoCAD SHX Text
TOTAL REQUIRED
AutoCAD SHX Text
AIR (CFM)
AutoCAD SHX Text
G.A. MECHANICAL CODE TABLE 403.3
AutoCAD SHX Text SAMPLE CALCULATIONS: Vbz = Rp*Pz+Ra+Az SHELL ZONE AIR DISTRIBUTION EFFECTIVENESS ZONE AIR DISTRIBUTION EFFECTIVENESS (2282 SQFT)(0.12 CFM/SQFT) = 273.8 CFM Ez = 1.0 Ez = 1.0 OFFICE ZONE OUTDOOR AIRFLOW ZONE OUTDOOR AIRFLOW (1 person)(5 CFM/person)+(77 SQFT)(0.06 CFM/SQFT) = 9.6 CFM Voz = Vbz/Ez = 784/1 = 784 CFM Voz = Vbz/Ez = 784/1 = 784 CFM TOILET (1 fixture)(50 CFM/fixture) = 50 CFM
AutoCAD SHX Text
OUTDOOR AIR
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
(CFM/SQ FT)
AutoCAD SHX Text
OUTDOOR AIR
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
(CFM/FIXTURE)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OUTDOOR AIR
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
(CFM/SHOWER)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 0.06
AutoCAD SHX Text 0.06
AutoCAD SHX Text 0.06
AutoCAD SHX Text 0.06
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 11.3
AutoCAD SHX Text 8.7
AutoCAD SHX Text 11.3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HALLWAY 207
AutoCAD SHX Text
OFFICE 201
AutoCAD SHX Text
OFFICE 202
AutoCAD SHX Text
OFFICE 206
AutoCAD SHX Text
BATHRM 209
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
# OF FIXTURES
AutoCAD SHX Text 7.0
AutoCAD SHX Text 20.6
AutoCAD SHX Text 23.9
AutoCAD SHX Text 20.6
AutoCAD SHX Text 100.0
AutoCAD SHX Text
TOTAL =
AutoCAD SHX Text 172.1
AutoCAD SHX Text
CENTRIFUGAL FORWARD CURVED
AutoCAD SHX Text
# OF SHOWERS
AutoCAD SHX Text NOTES: 1. PROVIDE BACKDRAFT DAMPER AND BIRD SCREEN. PROVIDE BACKDRAFT DAMPER AND BIRD SCREEN. 2. PROVIDE VIBRATION ISOLATORS, SEE SPECIFICATIONS. PROVIDE VIBRATION ISOLATORS, SEE SPECIFICATIONS. 3. FAN HOUSING SHALL BE CONSTRUCTED OF SPUN ALUMINUM. FAN HOUSING SHALL BE CONSTRUCTED OF SPUN ALUMINUM. 4. APPROVED EQUALS - COOK AND TWIN CITY. APPROVED EQUALS - COOK AND TWIN CITY. 5. PROVIDE SPEED CONTROL AND ADJUST TO PROVIDE DESIGN CFM. PROVIDE SPEED CONTROL AND ADJUST TO PROVIDE DESIGN CFM. 6. PROVIDE TIMECLOCK FOR FAN OPERATION TO ALLOW PROGRAMMING FOR PROVIDE TIMECLOCK FOR FAN OPERATION TO ALLOW PROGRAMMING FOR OPERATION DURING BUSINESS HOURS. FAN SHALL BE WIRED THROUGH TIMECLOCK.
AutoCAD SHX Text
GAS FURNACE UNIT
AutoCAD SHX Text
COOLING COIL
AutoCAD SHX Text
CONDENSING UNIT
AutoCAD SHX Text
SPLIT SYSTEM AIR HANDLER
AutoCAD SHX Text
SYSTEM NO.
AutoCAD SHX Text
TAG
AutoCAD SHX Text
CFM
AutoCAD SHX Text
MOTOR HP
AutoCAD SHX Text
TYPE FAN
AutoCAD SHX Text
ARRANGEMENT
AutoCAD SHX Text
VOLTAGE/HERTZ/PHASE
AutoCAD SHX Text
MCA/MOP
AutoCAD SHX Text
FUEL
AutoCAD SHX Text
FLUE VENT DIAMETER (IN)
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
TAG
AutoCAD SHX Text
CFM
AutoCAD SHX Text
COIL ARRANGEMENT
AutoCAD SHX Text
OA TEMP AT CONDENSING UNIT
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
TOTAL CAPACITY (MBH)
AutoCAD SHX Text
SENSIBLE CAPACITY (MBH)
AutoCAD SHX Text
TYPE OF SYSTEM
AutoCAD SHX Text
NUMBER & HP OF EACH FAN
AutoCAD SHX Text
TYPE OF ELECTRICAL CONNECTION
AutoCAD SHX Text
NUMBER OF COMPRESSORS
AutoCAD SHX Text
VOLTAGE / HERTZ / PHASE
AutoCAD SHX Text
MCA / MOCP
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL NUMBER
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
TYPE OF COOLING
AutoCAD SHX Text
ROWS
AutoCAD SHX Text
TAG
AutoCAD SHX Text
FUR-1
AutoCAD SHX Text 1,200
AutoCAD SHX Text
AutoCAD SHX Text 115/60/1
AutoCAD SHX Text
CIRCULATOR BLOWER
AutoCAD SHX Text 1X1
AutoCAD SHX Text
NAT. GAS
AutoCAD SHX Text
AutoCAD SHX Text
DM96MC1005CNA
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE W/ DRAIN
AutoCAD SHX Text
PAN
AutoCAD SHX Text
CC-1
AutoCAD SHX Text 1,200
AutoCAD SHX Text
HORIZONTAL A
AutoCAD SHX Text 80 / 67
AutoCAD SHX Text
AutoCAD SHX Text 22.8
AutoCAD SHX Text
SPLIT
AutoCAD SHX Text
CU-1
AutoCAD SHX Text 1 - 1/6
AutoCAD SHX Text
SINGLE-POINT
AutoCAD SHX Text
AutoCAD SHX Text
20.2 / 30.0
AutoCAD SHX Text
DAIKIN
AutoCAD SHX Text
DX5SEA3610
AutoCAD SHX Text
AutoCAD SHX Text
DAIKIN
AutoCAD SHX Text
LODGE ATTIC
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
DX
AutoCAD SHX Text
AutoCAD SHX Text
SERVES
AutoCAD SHX Text
LODGE 2ND FLOOR
AutoCAD SHX Text 230 / 60 / 1
AutoCAD SHX Text
CHPE3642C4
AutoCAD SHX Text
16.9 / 20
AutoCAD SHX Text NOTES: 1. INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE PIPING APPURTANCES AS REQUIRED. 2. REFRIGERANT TYPE SHALL BE R410A. REFRIGERANT TYPE SHALL BE R410A. 3. BASIS OF DESIGN IS DAIKIN. ACCEPTABLE EQUALS ARE TRANE. BASIS OF DESIGN IS DAIKIN. ACCEPTABLE EQUALS ARE TRANE. 4. PROVIDE AN OVERFLOW PAN WITH A WATER SENSOR AND PROVIDE AN OVERFLOW PAN WITH A WATER SENSOR AND CUTOFF SWITCH AS REQ-D BY GEORGIA MECHANICAL BUILDING CODE.
AutoCAD SHX Text
COMBUSTION FANS FLA (AMPS)
AutoCAD SHX Text
CAPACITY (MBH)
AutoCAD SHX Text 18.2
AutoCAD SHX Text
EAT DB/WB
AutoCAD SHX Text 1.0
AutoCAD SHX Text
AutoCAD SHX Text
SEER NUMBER
AutoCAD SHX Text 15.2
AutoCAD SHX Text
BIRDSCREEN & DAMPER
AutoCAD SHX Text
HOODED WALLCAP
AutoCAD SHX Text
EXHAUST DUCT
AutoCAD SHX Text
FILL WITH STYROFOAM INSUL. & CAULK EXTERIOR
AutoCAD SHX Text
SLOPED ROOF
AutoCAD SHX Text
STRUCTURE
AutoCAD SHX Text
MOUNT AS TIGHT TO STRUCTURE AS POSSIBLE
AutoCAD SHX Text
VIBRATION ISOLATION HANGERS
AutoCAD SHX Text
COOLING COIL
AutoCAD SHX Text
RETURN AIR DUCT
AutoCAD SHX Text
SUPPLY AIR DUCT
AutoCAD SHX Text
REFER TO MANUFACTURER'S INSTRUCTIONS FOR REFRIGERANT CONNECTIONS
AutoCAD SHX Text
OUTSIDE AIR DUCT
AutoCAD SHX Text EXHAUST FAN EF-1 OPERATION (ATTIC 301) 1. EXHAUST FAN EF-1 SHALL BE INTERLOCKED WITH AHU-1. IF AHU-1 IS ON, EF-1 SHALL BE EXHAUST FAN EF-1 SHALL BE INTERLOCKED WITH AHU-1. IF AHU-1 IS ON, EF-1 SHALL BE ON. IF AHU-1 IS OFF, EF-1 SHALL BE OFF. PROVIDE OVERRIDE SWITCHES IN EACH EXHAUSTED SPACE TO OPERATE EF-1 WHEN AHU-1 IS OFF. AIR HANDLING UNIT AHU-1 OPERATION (ATTIC 301) 2. OUTSIDE AIR MOTORIZED DAMPER SHALL BE INTERLOCKED WITH AHU-1. IF AHU-1 IS ON, OUTSIDE AIR MOTORIZED DAMPER SHALL BE INTERLOCKED WITH AHU-1. IF AHU-1 IS ON, OUTSIDE AIR MOTORIZED DAMPER SHALL BE OPEN. IF AHU-1 IS OFF, OUTSIDE AIR MOTORIZED DAMPER SHALL BE CLOSED. 3. OUTSIZE AIR MOTORIZED DAMPER SHALL BE INTERLOCKED WITH THE OVERRIDE SWITCHES FOR OUTSIZE AIR MOTORIZED DAMPER SHALL BE INTERLOCKED WITH THE OVERRIDE SWITCHES FOR EF-1. IF AN OVERRIDE SWITCH IS TURNED ON TO OPERATE EF-1, THE OUTSIDE AIR MOTORIZED DAMPER SHALL OPEN TO PROVIDE VENTILATION FOR THE SECOND FLOOR.
AutoCAD SHX Text
SPLIT SYSTEM AIR HANDLING UNITS (DUCTLESS)
AutoCAD SHX Text
UNIT WEIGHT: (LBS)
AutoCAD SHX Text GENERAL NOTES: 1. INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE PIPING APPURTENANCES AS REQUIRED. 2. UNIT SHALL BE PROVIDED WITH THE FOLLOWING FACTORY INSTALLED ACCESSORIES: (MODEL UNIT SHALL BE PROVIDED WITH THE FOLLOWING FACTORY INSTALLED ACCESSORIES: (MODEL NUMBER WILL REFLECT SOME OF THESE ACCESSORIES BUT NOT NECESSARILY ALL) LOW VOLTAGE INDOOR UNIT INDOOR UNIT IS POWERED FROM OUTDOOR UNIT. MECHANICAL CONTRACTOR SHALL CONNECT ELECTRICAL SERVICE FROM OUTDOOR CONDENSER TO INDOOR EVAPORATOR UNIT. AUTO RESTART DEHUMIDIFICATION MODE CLEANABLE FILTERS WALL MOUNTED THERMOSTATS 3. APPROVED EQUALS - MITSUBISHI AND CARRIER APPROVED EQUALS - MITSUBISHI AND CARRIER 4. PROVIDE UNIT WITH CONDENSATE PUMP.PROVIDE UNIT WITH CONDENSATE PUMP.
AutoCAD SHX Text
SYSTEM DESCRIPTION
AutoCAD SHX Text
OUTDOOR UNIT ELECT. CONN.
AutoCAD SHX Text
COOLING EDB/EWB (%%DF)
AutoCAD SHX Text
GROSS COOLING CAP (MBH)
AutoCAD SHX Text
TOTAL CFM
AutoCAD SHX Text
UNIT MODEL NUMBER:
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
UNIT TAG:
AutoCAD SHX Text
SEER
AutoCAD SHX Text
FAN MOTOR FLA
AutoCAD SHX Text
SPLIT SYSTEM
AutoCAD SHX Text
DAIKIN
AutoCAD SHX Text
SSCU-1
AutoCAD SHX Text
SPLIT SYSTEM
AutoCAD SHX Text
DAIKIN
AutoCAD SHX Text
SSEU-1
AutoCAD SHX Text
SEE NOTE 2
AutoCAD SHX Text
DUCTLESS SPLIT SYSTEM 1
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CONDENSING UNIT
AutoCAD SHX Text
EVAPORATOR UNIT
AutoCAD SHX Text 230/1Ø
AutoCAD SHX Text 13.3
AutoCAD SHX Text 1,051
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3.99
AutoCAD SHX Text
RK12AXVJU
AutoCAD SHX Text 95/75
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text 13.3
AutoCAD SHX Text 247/316/436
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3.99
AutoCAD SHX Text
FTK12AXVJU
AutoCAD SHX Text 80/67
AutoCAD SHX Text
IT CLOS - 109
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 5.
AutoCAD SHX Text 6.
AutoCAD SHX Text 7.
AutoCAD SHX Text 8.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
DRIP PAN SHALL BE GALVANIZED OR
AutoCAD SHX Text
STAINLESS STEEL. MIN 16 GA.
AutoCAD SHX Text
SLOPE DRIP PAN TO DRAIN POINT AT
AutoCAD SHX Text
MIN 1/8" PER FOOT.
AutoCAD SHX Text
DRIP PAN SHALL EXTEND BEYOND PIPE
AutoCAD SHX Text
INSULATION MIN OF 2".
AutoCAD SHX Text
DRIP PAN SHALL BE WATER TIGHT. CORNERS AND SEAMS SHALL BE
AutoCAD SHX Text
WELDED AND/OR SEALED WITH SILLICONE SEALANT.
AutoCAD SHX Text
DRAIN PORT MUST BE INSTALLED AT LOW POINT IN DRIP PAN AND
AutoCAD SHX Text
CONNECTION MUST BE WATER TIGHT.
AutoCAD SHX Text
DRAIN PIPE SHALL BE COPPER AND 3/4" DIAMETER INSULATED DRAW
AutoCAD SHX Text
PIPE. SEE FLOOR PLANS FOR DRAIN PIPE ROOTING.
AutoCAD SHX Text
DRIP PAN MUST BE SUPPORTED DIRECTLY FROM BUILDING STRUCTURE
AutoCAD SHX Text
AND MUST BE FREE-HANGING UNDER PIPE.
AutoCAD SHX Text
DRAINAGE PIPE
AutoCAD SHX Text
DRAIN TO
AutoCAD SHX Text
WALL OUTLET
AutoCAD SHX Text
2" MIN
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
DRIP PAN
AutoCAD SHX Text
DRAIN PIPE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
PROTECTED
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
HANGER
AutoCAD SHX Text
DRAINAGE PIPE DRIP PAN
AutoCAD SHX Text
AutoCAD SHX Text
NTS
| Sheets and Views |
| M-001 |
| Sheets and Views |
| M-002 |
File details come from the government source that posted it. Updated .