These documents are detailed engineering and installation guidelines from Brasco International, Inc. for their Interlude Transit Shelter product, which appears to be a modular glass and metal transit shelter system. The guidelines provide comprehensive instructions for installing expansion anchors, setting concrete pad specifications, and assembling various shelter components including columns, rafters, walls, and glass panels. Key installation requirements include using a minimum 4-inch thick, 3000 PSI concrete pad, ensuring anchors are installed at least 6 inches from concrete pad edges, and maintaining proper column alignment with approximately 1/4 inch slope per foot for drainage.

The documentation includes detailed technical drawings showing precise mounting hardware, connection points, and assembly techniques for different shelter components. Specific installation recommendations cover expansion anchor technical specifications, glass clamp assemblies, side wall connections, and schedule holder mounting. The documents emphasize following manufacturer recommendations for anchor installation, using specific washers and screws, and maintaining proper torque and embedment depths. The technical specifications appear designed to ensure structural integrity, weatherproofing, and long-term durability of the transit shelter system across various environmental conditions.

View the file

Other files

File Type Posted
FURNISH_AND_INSTALL_TRANSIT_SHELTERS.pdf PDF
FURNISH_AND_INSTALL_TRANSIT_SHELTERS.pdf PDF
LIVING_WAGE_CERTIFICATION.pdf PDF
LIVING_WAGE_CERTIFICATION.pdf PDF
Location_Map.pdf PDF
Location_Map.pdf PDF
Manufacturer's_Installation_Instructions.pdf PDF
Solar_PLS_Module_Sales_Sheet.pdf PDF
Interlude_Arch_and_Bench_Drawing.pdf PDF
Finish_Options.pdf PDF
Interlude_Arch_and_Bench_Drawing.pdf PDF
Interlude_Bench_Drawing.pdf PDF
Finish_Options.pdf PDF
Interlude_Arch_Shelter_Cut_Sheet.pdf PDF
Interlude_Bench_Cut_Sheet.pdf PDF
Interlude_Bench_Drawing.pdf PDF
Interlude_Arch_Shelter_Cut_Sheet.pdf PDF
Interlude_Bench_Cut_Sheet.pdf PDF
Light_Fixture_Cut_Sheet.pdf PDF
Light_Fixture_Cut_Sheet.pdf PDF
Solar_PLS_Module_Sales_Sheet.pdf PDF
Town_of_Manchester_Labor_and_Materials_Payment_Bond.pdf PDF
Town_of_Manchester_Performance_Bond.pdf PDF
Town_of_Manchester_2025_Holiday_Calendar.pdf PDF
Town_of_Manchester_Performance_Bond.pdf PDF
Town_of_Manchester_2025_Holiday_Calendar.pdf PDF
Town_of_Manchester_Contract_(Blank).pdf PDF
Town_of_Manchester_Contract_(Blank).pdf PDF
Town_of_Manchester_Labor_and_Materials_Payment_Bond.pdf PDF
Connecticut_Natural_Gas_Requirements.pdf PDF
DWSRF_Contracting_Requirements2.pdf PDF
Prevailing_Wage_Notes_and_Certification_Form_(Attachments_as_of_2023-09-27).pdf PDF
Connecticut_Natural_Gas_Requirements.pdf PDF
DWSRF_Contracting_Requirements2.pdf PDF
Prevailing_Wage_Notes_and_Certification_Form_(Attachments_as_of_2023-09-27).pdf PDF
Required_Provisions_-_FHWA_funded_projects.pdf PDF
CDBG_Requirements.pdf PDF
Contract_langauge_-_municipal_projects-_CHRO.pdf PDF
Required_Provisions_-_FHWA_funded_projects.pdf PDF
CTDOT_Pre-Award_DBE_Approval_Request_Form.pdf PDF
Special_Provisions_-_DBE_Requirements_for_Federal_Funded_Projects.pdf PDF
CTDOT_Pre-Award_DBE_Approval_Request_Form.pdf PDF
DWSRF_1445_Labor_Standards_Interview_Form.pdf PDF
Special_Provisions_-_DBE_Requirements_for_Federal_Funded_Projects.pdf PDF
CDBG_Requirements.pdf PDF
Contract_langauge_-_municipal_projects-_CHRO.pdf PDF
DWSRF_1445_Labor_Standards_Interview_Form.pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drill Motor Cordless Drill Rivet Gun

1/4” Drill Bit Air Compressor Tape Measure

#11 Drill Bit Steel Hammer Torque Wrench

8” Long 1/2” Masonry Drill Bits Dead Blow Hammer or Mallet 60” Bar Clamps

5/8” and 3/4” Socket and Wrench Bubble Level, Line / String Level Generator or Other Power Source

HD Drill Motor or Hammer Drill Min. 6ft. Step Ladder Shop Vac or Broom for Clean Up

TOOLS NEEDED

Storage

1. Products stored outside must be fully tarped. Wooden crates, cardboard boxes and identifying labels are not weatherproof and will deteriorate in the elements.

2. If your order includes solar lighting, be cautious when handling batteries as they are capable of generating hazardous short-circuit currents. Remove all jewelry (bracelets, metal watches, rings) before attempting to handle or disassemble batteries.

3. Batteries should be stored indoors at a recommended 68 degrees Fahrenheit for max shelf life.

4. Batteries should be installed no later than 3 months from delivery or battery warranties will be void.

BRASCO INTERNATIONAL, INC.

INSTALLATION GUIDELINES

Thank you for your order. Enclosed with these guidelines are engineering instructions specific to your order. Please review all pages in full before proceeding with your installation.

© 2017 Brasco International, Inc. All Rights Reserved.

(313) 393-0393 | www.brasco.com

Installing Expansion Anchors

Expansion Anchor Installed

Step 3.

Anchor Installation

Step 4.

Securing the Anchor Boot

Replace the anchor boot and align with holes in the concrete.

Make sure the nut on the expan-sion anchor is threaded to the top of the threaded rod to prevent damage to the threads.

Insert the expansion anchor through the base plate and into the hole in the concrete. Hit the expansion anchor with sharp blows until the washers are snug against the base plates.

Tighten the nut to the recommended installation torque.

Clean debris from holes using a wire brush, vacuum, or compressed air.

Step 1.

Prepping the Concrete

Using anchor boot as a template, mark hole locations and move anchor boot out of the way. Drill a hole the same diameter as the expansion anchor to a minimum depth of ½’’ deeper than the anchor will penetrate to allow debris to fall during installation

Step 2.

Prepping the Hole

Minimum thickness of fixture is a concern only when the anchor is installed at the minimum nominal embedment. When KWIK Bolt TZ anchors are installed at this embedment, the anchor threading ends near the surface of the concrete. If the fixture is sufficiently thin, it could be possible to run the nut to the bottom of the threading during application of the installation torque.

If fixtures are thin, it is recommended that embedment be increased accordingly.

(313) 393-0393 | www.brasco.com © 2017 Brasco International, Inc. All Rights Reserved.

Expansion Anchor Technical Chart

1. Locating proper column locations is critical. Care must be taken to keep columns plumb and walls square to each other.

2. Shelter should be sloped slightly to the rear for proper drainage. Approximately 1/4 inch slope per foot from front to rear of shelter is recommended.

Columns should be shimmed as necessary.

3. Anchors to be installed in conjunction with manufacturers recommendations only. (See Expansion Anchor Technical Chart on previous page.)

4. Anchors need to be installed a minimum of 6 inches from the edge of the concrete pad. See below for reference.

NOTE: This visual is for reference only. Brasco is not liable for concrete installation instructions unless structural concrete calculations are included with an order.

Consult your local building codes for specific concrete pad requirements.

RECOMMENDED: Brasco recommends a minimum 4 inch thick, 3000 PSI concrete pad for areas with wind speeds lower than 110 MPH. For areas with wind speeds higher than 110 MPH, Brasco recommends a minimum 6 inch thick, 3000 PSI concrete pad. The concrete pad should allow a minimum of 6 inches around the shelter’s perimeter to prevent concrete breakage when anchoring. Concrete may or may not require additional reinforcement.

(313) 393-0393 | www.brasco.com © 2020 Brasco International, Inc. All Rights Reserved.

Brasco Standard Anchoring Guidelines

Expansion Anchor Installed

Standard Concrete Pad Overview

PAD THICKNESS

VIEW A-A

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

DESCRIPTION: SHEET:JOB #

BRASCO INTERNATIONAL

INTERLUDE TRANSIT SHELTER

SHELTER ANCHOR STD.

M.FINK

5/10/19

CHECKER:

DATE:

REVISION:

BMB

5/10

A

AA

BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST

NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM

F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105

F1110 5/8-11 X 6" S.S. WEDGE ANCHOR W/NUT AND FLAT WASHERPUR.F1110

F1113 5/8" S.S. LOCK WASHERPUR.F1113

9.000"

5.000"

8.000"

REF.

12.000"

REF.

F1113

PUR.

F1110

PUR.

VIEW OF REAR TOP COLUMN

NOTE ARM TOP PLACEMENT

IS ATTACHED TO INNER PLATE

OF RAFTER AS SHOWN

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

DESCRIPTION: SHEET:JOB #

BRASCO INTERNATIONAL

INTERLUDE TRANSIT SHELTER

RAFTER TO COLUMN ASSEMBLY STD.

M.FINK

5/10/19

CHECKER:

DATE:

REVISION:

BMB

5/10

A

BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST

NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM

F1083 3/4" FLAT WASHERPUR.F1083

F1084 3/4" S.S. LOCK WASHERPUR.F1084

F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105

F1150 HEX HEAD BOLT - 3/4-10 X 2" LG.PUR.F1150

F1151 JAM NUT - 3/4-10PUR.F1151

F1152 SOCKET HEAD CAP SCREW - 3/4-10 X 7" LG.PUR.F1152

F1083

PUR.

F1150

PUR.

F1151

PUR.

F1084

PUR.

F1151

PUR.

F1084

PUR.

F1150

PUR.

F1084

PUR.

F1151

PUR.

F1083

PUR.

F1152

PUR.

SECTION A-A

DETAIL B

DETAIL C

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

DESCRIPTION: SHEET:JOB #

BRASCO INTERNATIONAL

INTERLUDE TRANSIT SHELTER

REAR WALL TO COLUMN ASSEMBLY STD.

M.FINK

5/10/19

CHECKER:

DATE:

REVISION:

BMB

5/10

A

A A

B C

BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST

NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM

F1052 1/4" S.S. FLAT WASHERPUR.F1052

F1055 1/4" S.S. LOCKWASHERPUR.F1055

F1059 1/4"-20 S.S. NUTPUR.F1059

F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105

F1137 1/4-20 X 1" LG. S.S. TAMPER RESISTANT BUTTON SOCKET CAP SCREWPUR.F1137

F1137

PUR.

F1052

PUR.

F1055

PUR.

F1059

PUR.

F1059

PUR.

F1055

PUR.

F1052

PUR.

F1126

PUR.

15.270" REF.

TYP.

SECTION D-D

SHOWING TYPICAL PURLIN

CONNECTIONS TO COLUMN RAFTERS

SECTION B-B

DETAIL C

SHOWING TYPICAL PCSS COVER ON

FRONT AND REAR OF THE SHELTER

SECTION E-E

SHOWING TYPICAL MID PRESSURE

PLATE CONNECTIONS TO RAFTERS

DETAIL F

SHOWING TYPICAL CONNECTIONS OF

ROOF PANELS TO END RAFTERS AND

PRESSURE PLATES TO RAFTER BASE

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

DESCRIPTION: SHEET:JOB #

BRASCO INTERNATIONAL

INTERLUDE TRANSIT SHELTER

ROOF DETAIL ASSEMBLY STD.

M.FINK

5/10/19

CHECKER:

DATE:

REVISION:

BMB

5/10

A

A A

D

D

B

B

C

E

E

F

BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST

NOTESPART NUMBERMODEL

NUMBERDESCRIPTIONSHTQTYITEM

SEE DWG. IT511FLAT BAR ASSEMBLY-SOLAR (5 FT.)5111511

F1006 1/4-20 X 1" S.S. HEX HEAD BOLTPUR.21F1006

F1027 #10-24 X 3/4" S.S. FLAT HEAD THREAD CUTTITG SCREWPUR.8F1027

SEE DWG. IT500RAFTER ASSY (5 FT.)5002500

SHOWING MOUNTING OF PRESSURE PLATES TO RAFTER BASE

PURLIN

VIEW SHOWING END RAFTER (LEFT)

AND MID RAFTER (RIGHT)

1/8" FOAM TAPE

F1006

PUR.

GLAZING END CHANNEL

RAFTER WELDMENT

GLAZING

GLAZING

F1027

PUR.

F1006

PUR.

(4) PER PURLIN

F1006

PUR.

F1006

PUR.ANGLE BRACKET END

CAP ASSEMBLY REF.

FLAT BAR ASSEMBLY REF.

SECTION B-B

DETAIL C

DETAIL D

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

DESCRIPTION: SHEET:JOB #

BRASCO INTERNATIONAL

INTERLUDE TRANSIT SHELTER

REAR WALL GLASS INSTALLATION STD.

M.FINK

5/10/19

CHECKER:

DATE:

REVISION:

BMB

5/10

A

B

B

AA

C

D

BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST

NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM

F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105

#M13-2511-000-12 3/8" LAMITATED GLASS CLAMPPUR.MORSE

GASKET FOR 3/8" GLASSPUR.MORSE#

GLASS CLAMP CAPPUR.MORSE#

GLASS CLAMP FASTENERPUR.MORSE#

CENTER GLASSCENTER GLASS

MORSE#

PUR.

MORSE#

PUR.

MORSE

PUR.

F1105

DETAIL B

VIEW SHOWING SIDE

WALL TO COLUMN CONNECTION

SECTION C-C

VIEW SHOWING GLASS CLAMP

ASSEMBLY TO WALL FRAME

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DR.

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

CUSTOMER: DESIGNER:

DATE:

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

PROJECT:

DESCRIPTION: SHEET:JOB #

BRASCO INTERNATIONAL

INTERLUDE TRANSIT SHELTER

SIDE WALL W/GLASS ASSEMBLY STD.

M.FINK

5/10/19

CHECKER:

DATE:

REVISION:

BMB

5/10

A

A A

B

C

C

BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST

NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM

F1052 1/4" S.S. FLAT WASHERPUR.F1052

F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105

F1137 1/4-20 X 1" LG. S.S. TAMPER RESISTANT BUTTON SOCKET CAP SCREWPUR.F1137

#M13-2511-000-12 3/8" LAMITATED GLASS CLAMPPUR.MORSE

GLASS CLAMP CAPPUR.MORSE#

GLASS CLAMP FASTENERPUR.MORSE#

MORSE#

PUR.

MORSE#

PUR.

MORSE

PUR.

F1137

PUR.

F1052

SCHEDULE HOLDER TO GLASS

MOUNTING HARDWARE (4X) TYP.

SCHEDULE HOLDER

A

F1213 NYLON FLAT WASHER, WHITE,---

3/8" SCREW SIZE, 0.406" ID, 1.000" OD

SECTION A-A

F1052 FLAT WASHER 1/4" 304S

F1055 LOCK WASHER 1/4" 304S--

F1149 TAMPER RESISTANT----i

SCREW 1 /4-20 X 1" 304S

F1215 NYLON UNTHREADED--_,

SPACER 3/4" OD, 3/8" LENGTH

DETAIL B

F1055 LOCK WASHER

1/4" 304S

BRASCO INTERNATIONAL, INC.

32400 INDUSTRIAL DRIVE

VIEW SHOWING SHCEDULE HOLER MOUNTED

TO 3/8" GLASS DURING INSTALLATION

MADISON HEIGHTS, MICHIGAN 48071

1-800-893-3665 WWW.BRASCO.COM

THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF

OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED

WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.

LEAD TIME BEGINS UPON RECEIPT OF SIGNED APPROVAL.

© SIGNED: DATE:

CUSTOMER:

PROJECT:

MODEL:

INSTALLATION INSTRUCTIONS

GLASS / GROMMET MOUNTED DISPLAY CASE

INTERLUDE SERIES

ENGINEER: M.FINK

DATE: 5/10/19

CHECKER: BMB

DATE: 5/10/19

JOB # STD. SHEET #: 7

Customer Copy3sht.pdf
Brasco General Installation Instructions Cover Pages Revised 8-17-17