These installation guidelines from Brasco International, Inc. detail technical specifications and assembly instructions for an Interlude Transit Shelter. The document provides comprehensive guidance for installing a transit shelter, including detailed technical drawings, anchoring guidelines, and specific instructions for assembling components such as columns, rafters, glass walls, and mounting hardware. The guidelines cover critical installation steps like concrete pad preparation, expansion anchor installation, column positioning, and proper drainage slope, with recommended minimum concrete pad specifications of 4-6 inches thick at 3000 PSI, depending on wind speed conditions.
The technical documentation includes precise mechanical drawings showing multiple assembly views, connection details, and hardware specifications. Key installation requirements include maintaining column verticality, ensuring walls are square, implementing a slight rear slope for drainage, and following specific anchor installation protocols. The guidelines emphasize precise measurements, proper tool usage (including drill motors, socket wrenches, levels, and step ladders), and careful handling of components like solar lighting batteries. The documents are dated 2017-2020 and provide engineering-level detail for professional installation of the transit shelter system, with particular attention to structural integrity and wind resistance.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Drill Motor Cordless Drill Rivet Gun
1/4” Drill Bit Air Compressor Tape Measure
#11 Drill Bit Steel Hammer Torque Wrench
8” Long 1/2” Masonry Drill Bits Dead Blow Hammer or Mallet 60” Bar Clamps
5/8” and 3/4” Socket and Wrench Bubble Level, Line / String Level Generator or Other Power Source
HD Drill Motor or Hammer Drill Min. 6ft. Step Ladder Shop Vac or Broom for Clean Up
TOOLS NEEDED
Storage
1. Products stored outside must be fully tarped. Wooden crates, cardboard boxes and identifying labels are not weatherproof and will deteriorate in the elements.
2. If your order includes solar lighting, be cautious when handling batteries as they are capable of generating hazardous short-circuit currents. Remove all jewelry (bracelets, metal watches, rings) before attempting to handle or disassemble batteries.
3. Batteries should be stored indoors at a recommended 68 degrees Fahrenheit for max shelf life.
4. Batteries should be installed no later than 3 months from delivery or battery warranties will be void.
BRASCO INTERNATIONAL, INC.
INSTALLATION GUIDELINES
Thank you for your order. Enclosed with these guidelines are engineering instructions specific to your order. Please review all pages in full before proceeding with your installation.
© 2017 Brasco International, Inc. All Rights Reserved.
(313) 393-0393 | www.brasco.com
Installing Expansion Anchors
Expansion Anchor Installed
Step 3.
Anchor Installation
Step 4.
Securing the Anchor Boot
Replace the anchor boot and align with holes in the concrete.
Make sure the nut on the expan-sion anchor is threaded to the top of the threaded rod to prevent damage to the threads.
Insert the expansion anchor through the base plate and into the hole in the concrete. Hit the expansion anchor with sharp blows until the washers are snug against the base plates.
Tighten the nut to the recommended installation torque.
Clean debris from holes using a wire brush, vacuum, or compressed air.
Step 1.
Prepping the Concrete
Using anchor boot as a template, mark hole locations and move anchor boot out of the way. Drill a hole the same diameter as the expansion anchor to a minimum depth of ½’’ deeper than the anchor will penetrate to allow debris to fall during installation
Step 2.
Prepping the Hole
Minimum thickness of fixture is a concern only when the anchor is installed at the minimum nominal embedment. When KWIK Bolt TZ anchors are installed at this embedment, the anchor threading ends near the surface of the concrete. If the fixture is sufficiently thin, it could be possible to run the nut to the bottom of the threading during application of the installation torque.
If fixtures are thin, it is recommended that embedment be increased accordingly.
(313) 393-0393 | www.brasco.com © 2017 Brasco International, Inc. All Rights Reserved.
Expansion Anchor Technical Chart
1. Locating proper column locations is critical. Care must be taken to keep columns plumb and walls square to each other.
2. Shelter should be sloped slightly to the rear for proper drainage. Approximately 1/4 inch slope per foot from front to rear of shelter is recommended.
Columns should be shimmed as necessary.
3. Anchors to be installed in conjunction with manufacturers recommendations only. (See Expansion Anchor Technical Chart on previous page.)
4. Anchors need to be installed a minimum of 6 inches from the edge of the concrete pad. See below for reference.
NOTE: This visual is for reference only. Brasco is not liable for concrete installation instructions unless structural concrete calculations are included with an order.
Consult your local building codes for specific concrete pad requirements.
RECOMMENDED: Brasco recommends a minimum 4 inch thick, 3000 PSI concrete pad for areas with wind speeds lower than 110 MPH. For areas with wind speeds higher than 110 MPH, Brasco recommends a minimum 6 inch thick, 3000 PSI concrete pad. The concrete pad should allow a minimum of 6 inches around the shelter’s perimeter to prevent concrete breakage when anchoring. Concrete may or may not require additional reinforcement.
(313) 393-0393 | www.brasco.com © 2020 Brasco International, Inc. All Rights Reserved.
Brasco Standard Anchoring Guidelines
Expansion Anchor Installed
Standard Concrete Pad Overview
PAD THICKNESS
VIEW A-A
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DR.
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
CUSTOMER: DESIGNER:
DATE:
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
PROJECT:
DESCRIPTION: SHEET:JOB #
BRASCO INTERNATIONAL
INTERLUDE TRANSIT SHELTER
SHELTER ANCHOR STD.
M.FINK
5/10/19
CHECKER:
DATE:
REVISION:
BMB
5/10
A
AA
BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST
NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM
F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105
F1110 5/8-11 X 6" S.S. WEDGE ANCHOR W/NUT AND FLAT WASHERPUR.F1110
F1113 5/8" S.S. LOCK WASHERPUR.F1113
9.000"
5.000"
8.000"
REF.
12.000"
REF.
F1113
PUR.
F1110
PUR.
VIEW OF REAR TOP COLUMN
NOTE ARM TOP PLACEMENT
IS ATTACHED TO INNER PLATE
OF RAFTER AS SHOWN
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DR.
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
CUSTOMER: DESIGNER:
DATE:
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
PROJECT:
DESCRIPTION: SHEET:JOB #
BRASCO INTERNATIONAL
INTERLUDE TRANSIT SHELTER
RAFTER TO COLUMN ASSEMBLY STD.
M.FINK
5/10/19
CHECKER:
DATE:
REVISION:
BMB
5/10
A
BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST
NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM
F1083 3/4" FLAT WASHERPUR.F1083
F1084 3/4" S.S. LOCK WASHERPUR.F1084
F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105
F1150 HEX HEAD BOLT - 3/4-10 X 2" LG.PUR.F1150
F1151 JAM NUT - 3/4-10PUR.F1151
F1152 SOCKET HEAD CAP SCREW - 3/4-10 X 7" LG.PUR.F1152
F1083
PUR.
F1150
PUR.
F1151
PUR.
F1084
PUR.
F1151
PUR.
F1084
PUR.
F1150
PUR.
F1084
PUR.
F1151
PUR.
F1083
PUR.
F1152
PUR.
SECTION A-A
DETAIL B
DETAIL C
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DR.
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
CUSTOMER: DESIGNER:
DATE:
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
PROJECT:
DESCRIPTION: SHEET:JOB #
BRASCO INTERNATIONAL
INTERLUDE TRANSIT SHELTER
REAR WALL TO COLUMN ASSEMBLY STD.
M.FINK
5/10/19
CHECKER:
DATE:
REVISION:
BMB
5/10
A
A A
B C
BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST
NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM
F1052 1/4" S.S. FLAT WASHERPUR.F1052
F1055 1/4" S.S. LOCKWASHERPUR.F1055
F1059 1/4"-20 S.S. NUTPUR.F1059
F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105
F1137 1/4-20 X 1" LG. S.S. TAMPER RESISTANT BUTTON SOCKET CAP SCREWPUR.F1137
F1137
PUR.
F1052
PUR.
F1055
PUR.
F1059
PUR.
F1059
PUR.
F1055
PUR.
F1052
PUR.
F1126
PUR.
15.270" REF.
TYP.
SECTION D-D
SHOWING TYPICAL PURLIN
CONNECTIONS TO COLUMN RAFTERS
SECTION B-B
DETAIL C
SHOWING TYPICAL PCSS COVER ON
FRONT AND REAR OF THE SHELTER
SECTION E-E
SHOWING TYPICAL MID PRESSURE
PLATE CONNECTIONS TO RAFTERS
DETAIL F
SHOWING TYPICAL CONNECTIONS OF
ROOF PANELS TO END RAFTERS AND
PRESSURE PLATES TO RAFTER BASE
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DR.
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
CUSTOMER: DESIGNER:
DATE:
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
PROJECT:
DESCRIPTION: SHEET:JOB #
BRASCO INTERNATIONAL
INTERLUDE TRANSIT SHELTER
ROOF DETAIL ASSEMBLY STD.
M.FINK
5/10/19
CHECKER:
DATE:
REVISION:
BMB
5/10
A
A A
D
D
B
B
C
E
E
F
BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST
NOTESPART NUMBERMODEL
NUMBERDESCRIPTIONSHTQTYITEM
SEE DWG. IT511FLAT BAR ASSEMBLY-SOLAR (5 FT.)5111511
F1006 1/4-20 X 1" S.S. HEX HEAD BOLTPUR.21F1006
F1027 #10-24 X 3/4" S.S. FLAT HEAD THREAD CUTTITG SCREWPUR.8F1027
SEE DWG. IT500RAFTER ASSY (5 FT.)5002500
SHOWING MOUNTING OF PRESSURE PLATES TO RAFTER BASE
PURLIN
VIEW SHOWING END RAFTER (LEFT)
AND MID RAFTER (RIGHT)
1/8" FOAM TAPE
F1006
PUR.
GLAZING END CHANNEL
RAFTER WELDMENT
GLAZING
GLAZING
F1027
PUR.
F1006
PUR.
(4) PER PURLIN
F1006
PUR.
F1006
PUR.ANGLE BRACKET END
CAP ASSEMBLY REF.
FLAT BAR ASSEMBLY REF.
SECTION B-B
DETAIL C
DETAIL D
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DR.
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
CUSTOMER: DESIGNER:
DATE:
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
PROJECT:
DESCRIPTION: SHEET:JOB #
BRASCO INTERNATIONAL
INTERLUDE TRANSIT SHELTER
REAR WALL GLASS INSTALLATION STD.
M.FINK
5/10/19
CHECKER:
DATE:
REVISION:
BMB
5/10
A
B
B
AA
C
D
BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST
NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM
F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105
#M13-2511-000-12 3/8" LAMITATED GLASS CLAMPPUR.MORSE
GASKET FOR 3/8" GLASSPUR.MORSE#
GLASS CLAMP CAPPUR.MORSE#
GLASS CLAMP FASTENERPUR.MORSE#
CENTER GLASSCENTER GLASS
MORSE#
PUR.
MORSE#
PUR.
MORSE
PUR.
F1105
DETAIL B
VIEW SHOWING SIDE
WALL TO COLUMN CONNECTION
SECTION C-C
VIEW SHOWING GLASS CLAMP
ASSEMBLY TO WALL FRAME
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DR.
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
CUSTOMER: DESIGNER:
DATE:
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
PROJECT:
DESCRIPTION: SHEET:JOB #
BRASCO INTERNATIONAL
INTERLUDE TRANSIT SHELTER
SIDE WALL W/GLASS ASSEMBLY STD.
M.FINK
5/10/19
CHECKER:
DATE:
REVISION:
BMB
5/10
A
A A
B
C
C
BRASCO INTERNATIONAL SUB ASSEMBLY PARTS LIST
NOTESPART NUMBERMODEL NUMBERDESCRIPTIONSHTITEM
F1052 1/4" S.S. FLAT WASHERPUR.F1052
F1105 1/4-20 X 3/4" LG. S.S. TAMPER RESISTANT SCREWPUR.F1105
F1137 1/4-20 X 1" LG. S.S. TAMPER RESISTANT BUTTON SOCKET CAP SCREWPUR.F1137
#M13-2511-000-12 3/8" LAMITATED GLASS CLAMPPUR.MORSE
GLASS CLAMP CAPPUR.MORSE#
GLASS CLAMP FASTENERPUR.MORSE#
MORSE#
PUR.
MORSE#
PUR.
MORSE
PUR.
F1137
PUR.
F1052
SCHEDULE HOLDER TO GLASS
MOUNTING HARDWARE (4X) TYP.
SCHEDULE HOLDER
A
F1213 NYLON FLAT WASHER, WHITE,---
3/8" SCREW SIZE, 0.406" ID, 1.000" OD
SECTION A-A
F1052 FLAT WASHER 1/4" 304S
F1055 LOCK WASHER 1/4" 304S--
F1149 TAMPER RESISTANT----i
SCREW 1 /4-20 X 1" 304S
F1215 NYLON UNTHREADED--_,
SPACER 3/4" OD, 3/8" LENGTH
DETAIL B
F1055 LOCK WASHER
1/4" 304S
BRASCO INTERNATIONAL, INC.
32400 INDUSTRIAL DRIVE
VIEW SHOWING SHCEDULE HOLER MOUNTED
TO 3/8" GLASS DURING INSTALLATION
MADISON HEIGHTS, MICHIGAN 48071
1-800-893-3665 WWW.BRASCO.COM
THIS DRAWING IS CONFIDENTIAL AND IS FOR THE SOLE USE OF
OUR CUSTOMERS AND MAY NOT BE REPRODUCED OR COPIED
WITHOUT WRITTEN PERMISSION FROM BRASCO INTERNATIONAL.
LEAD TIME BEGINS UPON RECEIPT OF SIGNED APPROVAL.
© SIGNED: DATE:
CUSTOMER:
PROJECT:
MODEL:
INSTALLATION INSTRUCTIONS
GLASS / GROMMET MOUNTED DISPLAY CASE
INTERLUDE SERIES
ENGINEER: M.FINK
DATE: 5/10/19
CHECKER: BMB
DATE: 5/10/19
JOB # STD. SHEET #: 7
| Customer Copy3sht.pdf |
| Brasco General Installation Instructions Cover Pages Revised 8-17-17 |
| Ins 1 |
| Ins 2 |
| Standard HDPE Bench |
| Shelter |
| Wall Layout |
| Hardware Box Packing List |
| Walls Lineals Pack List |
File details come from the government source that posted it. Updated .