System Design Reference Package.pdf
PDF 841 KB Posted
- Attached to
- Cellular Booster MCRC Brooklyn, NY
- Solicitation number
- M6786126Q0026
- Issued by
-
United States Marine Corps
About this file
This is a System Design Reference Package documenting a validated technical solution for in-building cellular coverage enhancement at MCRC Brooklyn, NY Reserve Center (6th Communication Battalion). The reference package is provided for Government planning and source-selection purposes based on an on-site RF survey, with component types and quantities subject to confirmation by final site survey prior to award.
The system is a multi-band Distributed Antenna System/signal booster architecture supporting AT&T, Verizon, and T-Mobile carriers including Low-Band 5G (approximately 600 MHz–1 GHz), targeting 90% coverage at RSRP −100 dBm or better. Major equipment includes three donor antennas (698–2700 MHz high-isolation patch, roof/parapet mounted), one donor combiner/2-way splitter, one quad-band digital repeater network/head-end unit located in 2nd Floor Telecom Room 213 on a dedicated 110V circuit, six coverage units distributed across 1st and 2nd floors fed via duplex Cat6 cables, and twenty-four interior ceiling-dome broadcast antennas (~15 ft+ radius each). Supporting components include splitters (14 total), couplers (4 total), 1×2 coax cables (32 total), donor coax (1/2" OSP), and Cat6 data backbone with fiber link extender as required. Installation assumes suitable space and 110V duplex receptacles at each amplifier location (Government-furnished), completed pathways from roof to head-end, accessible ceiling routes to antenna locations, and J-hook support to maximum 14' ceiling height. System registration with each carrier and equipment manufacturer per 47 CFR Part 20.21 is required prior to activation. Remote management must be controlled by Government IT/communications personnel consistent with cybersecurity requirements. The package includes detailed engineering drawings showing roof donor antenna locations, first and second floor equipment layouts, predicted RF coverage heat maps, and a detailed system schematic.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment M6786126Q00260001 SF 30.pdf | ||
| Salient Characteristics.pdf | ||
| Solicitation - M6786126Q0026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYSTEM DESIGN REFERENCE – IN-BUILDING CELLULAR COVERAGE – MCRC BROOKLYN, NY
DISTRIBUTION: DoW COMMUNITY ONLY • Page 1 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
SYSTEM DESIGN – REFERENCE PACKAGE
IN-BUILDING CELLULAR COVERAGE ENHANCEMENT SYSTEM
MCRC Brooklyn, NY Reserve Center – 6th Communication Battalion
Purpose: This reference package documents one validated technical solution for achieving the required in-building cellular coverage, derived from an on-site RF survey of the facility. It is provided for Government planning and source-selection reference. Component types and quantities reflect one acceptable, surveyed design; final quantities and locations for any awarded effort shall be confirmed by a site survey. This package contains no proprietary vendor identification.
1. System Overview
The system is a multi-band in-building cellular coverage enhancement solution (Distributed Antenna System / signal booster architecture) supporting AT&T, Verizon, and T-Mobile, including Low-Band 5G (approximately 600 MHz–1 GHz). Three (3) roof/parapet donor antennas receive the commercial carrier signal and feed a centralized network/head-end unit located in the 2nd Floor Telecom Room (Room 213). The head-end distributes to six (6) coverage units across the 1st and 2nd floors, which in turn feed twenty-four (24) interior broadcast (ceiling-dome) antennas. The design targets 90% coverage at RSRP −100 dBm or better.
2. System Block Diagram (One-Line)
DISTRIBUTION: DoW COMMUNITY ONLY • Page 2 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
DISTRIBUTION: DoW COMMUNITY ONLY • Page 3 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
3. Major Equipment Summary
Qty Component / Function Location Notes
3 Donor antenna – high-isolation patch, 698–2700 MHz Roof / parapet Mast/wall mount; combined to head-end
1 Donor combiner / 2-way splitter Roof / IT room Combines donor feeds
1 Network / head-end unit (quad-band digital repeater / network unit) Telecom Rm 213 (2nd Flr)
Dedicated 110V circuit;
carrier + FCC registered
6 Coverage units (CU) – distributed amplification 1st & 2nd floors
Fed from NU via duplex Cat6 (2 per CU)
24 Interior broadcast antennas (ceiling dome) 1st & 2nd floors
~15 ft+ radius each; marked locations
As req. Splitters, couplers, 1×2 coax, connectors, mounting hardware Throughout Per coverage-unit detail (Section 4)
— Donor coax (1/2" OSP), Cat6 data backbone, fiber link extender (as required) Riser / pathways
J-hook supported to max 14' ceiling
Carrier bands supported: AT&T, Verizon, T-Mobile (incl. Low-Band 5G, ~600 MHz–1 GHz, DSS). Registration required with each carrier and with the equipment manufacturer per 47 CFR Part 20.21.
DISTRIBUTION: DoW COMMUNITY ONLY • Page 4 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
4. Coverage Unit Component Breakdown
Coverage Unit Floor Splitters Couplers 1×2 Coax cables Broadcast antennas CU-1 1st Floor 3 — 5 4 CU-2 1st Floor 3 — 5 4 CU-3 1st Floor 1 2 6 4 CU-4 1st Floor 1 2 6 4 CU-5 2nd Floor 3 — 5 4 CU-6 2nd Floor 3 — 5 4
TOTAL — 14 4 32 24
Each coverage unit is mounted above the ceiling at a marked location and connected to the network/head-end unit by duplex Cat6 (two cables per unit). Quantities reflect one surveyed design and are subject to confirmation by site survey.
DISTRIBUTION: DoW COMMUNITY ONLY • Page 5 of 13
5. Mounting & Installation Details
6. Installation Notes & Assumptions
Donor antennas: Mounted to roof/parapet via mast and heavy wall mounts; coax routed through a NEMA enclosure at the wall penetration to the head-end. Penetrations sleeved and fire-stopped after completion; grounding provided per code at each location.
Head-end / amplifier locations: Suitable space and a standard 110V duplex receptacle are required at each amplifier/head-end location (Government-furnished). Completed pathway from roof donor antennas to the head-end is assumed available.
DISTRIBUTION: DoW COMMUNITY ONLY • Page 6 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
Interior antennas / pathways: Cable routed above accessible ceilings on J-hook supports to a maximum 14' ceiling height; work areas assumed accessible via ladders (no scissor-lift/lift rental included). Suitable ceiling pathways assumed to all interior antenna locations.
Registration (FCC): System registered with the equipment manufacturer and with each cellular carrier prior to or concurrent with activation, per 47 CFR Part 20.21.
Remote management: Any remote-management capability is to be managed/regulated by a Government employee or military member within the unit’s communications (G-6/S-6) element, consistent with Government IT/cybersecurity requirements.
Site survey required: Final equipment types, quantities, and component locations shall be determined by a physical site survey and confirmed in writing with the COR prior to installation. The quantities shown represent one validated, surveyed solution and are not mandatory minimums for an “or equal” approach.
DISTRIBUTION: DoW COMMUNITY ONLY • Page 7 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
7. As-Surveyed Engineering Drawings
The following drawings were produced from a physical RF survey of the facility and depict equipment placement and predicted coverage on the actual building floor plans. They are reproduced here for Government reference with all vendor identification removed. Coverage predictions reflect the surveyed design; an awarded contractor shall confirm final placement and verify coverage by post-installation survey.
Each drawing is presented on its own page for legibility.
DISTRIBUTION: DoW COMMUNITY ONLY • Page 8 of 13
7.1 Roof Plan – Donor Antenna Location
DISTRIBUTION: DoW COMMUNITY ONLY • Page 9 of 13
7.2 First Floor – Equipment Layout
DISTRIBUTION: DoW COMMUNITY ONLY • Page 10 of 13
7.3 First Floor – Predicted RF Coverage (Heat Map)
DISTRIBUTION: DoW COMMUNITY ONLY • Page 11 of 13
7.4 Second Floor – Equipment Layout
DISTRIBUTION: DoW COMMUNITY ONLY • Page 12 of 13
7.5 Second Floor – Predicted RF Coverage (Heat Map)
DISTRIBUTION: DoW COMMUNITY ONLY • Page 13 of 13
DISTRIBUTION: DoW COMMUNITY ONLY
7.6 As-Surveyed System Schematic (Detailed)
Detailed as-surveyed schematic showing donor antennas (roof), the network/head-end unit, and coverage-unit distribution across both levels. See the simplified one-line in Section 2 for a readable summary.