Replacement of Air Conditioning System at Multi Purpose Building Federal contract opportunity
Solicitation number
191T7020R0001
Issued by
Department of State

View the file

Other files for this federal contract opportunity

Other files attached to Replacement of Air Conditioning System at Multi Purpose Building, newest first.
File Type Posted
OF-174 Security Form Attachment 4.pdf PDF
M202REV 2 - Attachment 3.pdf PDF
SF-1442.doc DOC document
Cover Letter.pdf PDF
M203 REV 2 - Attachment 3.pdf PDF
Technical Specifications - SOW - Attachment 1.pdf PDF
BILL OF QUANTITY - Attachment 2.pdf PDF
191T7020R0001.doc DOC document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

A

ROOM 12

1. Room List

ROOM 11

1st FLOOR

ELECTRIC

PANEL

FIRST FLOOR OFFICES

ROOM 10 ROOM 9 ROOM 8 ROOM 7

ROOM 13 ROOM 14 ROOM 15 ROOM 16

HATCH IN THE FALSE CEILING WITH RETRACTILE STAIR

TO ACCESS THE NEW CATWALK ABOVE FALSE CEILING

Heier

ROOM 6

ROOM 17

2 UNCLASSIFIED

ROOM 5 ROOM 4

ROOM 18 ROOM 19 ROOM 20

380 V SUB PANEL

G42

ROOM 3

ELEC./ J

G44

STEEL SUPPORTING PLATFORM

VRF EXTERNAL UNIT . ·

REFLECTED CEILING VIEW OF INTERNAL UNIT

AND RELEVANT HATCH IN THE FALSE CEILING

TO HAVE ACCESS TO THE PIPING AND

ELECTRIC CONNECTIONS

PIPING BACK TO MOTORPOOL ROOMS 1 TO 3 AS PER

PIPING SKELETON IN DRAWING M202

ROOM 2 ROOM 1

GROUND FLOOR OFFICES

Cooling Design

Load

(Sens1blerTotal 1(kW) ••1

C STUDS ON

WALL H 40 mm I- CATWALK KELLER 15x76

I MAIN BAR 35 mm x2 SPACED 15 mm

G39 G44 G41 @)

G43

RMDD1 27,24 omce

RM002 12,03 Office iiiiiiii-,F

RM003 21,29 Office

44,85 Office

4,53

14,3

14,5

RM009 14,41

RMD10 13,95

RM011 14,98

Office

Office

Office

Office

Office

Office

RM012 16,78 Office

RM013 14,08 omce

RM014 14, 17 Office

RMD15 14,09 Office

RM016 14,15 Office

RM017 14, 14 Office

14, 11

RM020 Office

313,35

1,111,48

312,62

1,8/1,77

3,615,52

1,8/J ,7

1,811,76

1,811,78

1,811,77

1,811,72

1,811,84

1,812,06

1,811,73

1,811,74

1,8/1,73

1,811,74

1,811,7

1,811,74

4,5911,74

0110,08

314,59

1,211,6

314,59

1,912,29

3,814,59

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

1,912,29

,912,29

4,811,31 110010 2

4,812,15

,4/0,l

50010

110010

1000 ... 10 ==;;=--=I

200010 2

000/0

1 00010 .

100010

100010

100010

1 ooo ... 1o """iii

...i=I

100010

100010

1000/0

100010

100010 "111==1

1,912,29 ;;11=;;

2 ... ,4 ./0, 68

""""!!!il=- 6..,, 19./0::,;,6..,8

013,93

4,816,1

1 000

"'=11

==1

163010 2

DID 0

FIRST FLOOR OFFICES ROOM

AND EQUIPMENT LIST

The Haier Piojecl &press is properly of Haier Air-Con Elec.Co1p.Ltd. Only \lie dala published in lhe orricial documents is ei.aclly coned.All the data used in th s program is just for your information 2

DETAIL 1

I I

I I I I I

I DRYWALL

STRUCTURE H

50 mm

DRYWALL BOARD TYPE

KNAUF GKB ADVANCED

NEW CATWALK IN

CORRIDOR SCALE 1: 5

QUOTE IN MILLIMETERS

ij ij

+-�2=69=.o�-11 --'1=57�.0�11�-2=6=9-�0 q.,F __ ,o EM OLI Tl ON OF FALSE CEILING

I 1s1.o 1017.0

EXISTING TYPICAL 1st FL. SECTION & DEMOLITIONS

VALVE BOX SUSPENDED FROM CABLE TRAY

RECUPERATOR AND RELEVANT DUCT WORK

INTERNAL UNIT ABOVE FALSE CEILING

METALLIC CABLE TRAY FOR BCC A/C

INSTALLATIONS ABOVE FALSE CEILING

UNCLASSIFIED

METALLIC CABLE TRAY HOUSING

VRF PIPING AND POWER CABLES

CONDENSATE DRAIN TO NEW MANIFOLD

ABOVE CORRIDOR FALSE CEILING

\� NEW CATWALK ABOVE FALSE CEILING

SEE DETAIL 1

EMBASSY OF

THE UNITED STATES OF AMERICA

ROME ITALY

\ I ARN ING, This docl.f1ent is the property of the U.S. Govern•ent. Further reproduction ond/or W ' distribution is prohibited without the express written per,ission of, □ffice of Foreign

Buildings Operotions, U.S. DeportMent of Sbte, \loshington, DC, 20522-0620, Infor,otlon on this docu•ent Is not to be oltered except with the written opprovol of the individunl whose senl nppenrs hereon.

NOTE:

FOR ACTUAL REFRIGERANT LINES SKELETON AND SIZE

REFER TO DRAWING M 202

FOR VENTILATION LAYOUT REFER TO DRAWING M203

ELECTRICAL

CONNECT EXTERNAL UNIT POWER TOAN AVILABLE 60

AMPS CIRCUIT BREAKER IN MOP ON GROUND FLOOR

ELECTRIC ROOM.

CONNECT MOTORPOOL INTERNAL UNITS TO EXISTING

220V PANEL INSIDE ELECTRIC ROOM

CONNECT FIRST FLOOR INTERNAL UNITS TO LOCAL

FLOOR PANEL

ELECTRIC AND BUS LINES ABOVE FALSE CEILING

SHALL RUIN INSIDE ELECTRICAL METAL TUBING (EMT)

EXPOSED ON WALLS.

IN ALL OTHER LOCATIONS SAME LINE SHALL BE

BURIED INSIDE MASONRY AND WIRING SHALL RUN

INSIDE HEAVY PVC CONDUITS (RK15)

WIRING INSIDE EMT'S SHALL BE MUL Tl CORE 3G OR 5G, WHILE INSIDE PVC CONDUITS CAN BE SINGLE CORE

WITHOUT JACKET

Project title:

NEW AIR CONDITIONING

FB□ Project NuMber:

Property NuMber X - 1007

Dre.wing Title:

EQUIPMENT LAYOUT AND SCHEMATIC

REFRIGERANT LINES

ROUTING

F AC-Engineering MARCH 20, 2020 Issued for: Approve.I o.nd Bidding

REV.No, Dote Revision

05/29/2020 CHAl'lGED SECURITY CLASSIFICATI□l'l

Seo.le 1:100 M 201

Approvnl

B

A

File details come from the government source that posted it. Updated .