Amendment of Solicitation Summary

This is a Standard Form 30 (SF 30) Amendment of Solicitation issued by the Commanding General, Marine Corps Base, Camp Pendleton, California. The amendment (M0068126Q00640001, effective 11 August 2026) extends the proposal/quotation due date from 14 August 2026 to 17 August 2026 at 12:30 PM Pacific and provides seven questions and answers addressing industry inquiries regarding the requirement.

The solicitation pertains to hydrostatic testing and certification of 548 compressed air cylinders distributed across three Fire & Emergency Services locations at Camp Pendleton, Miramar, and Barstow. Key clarifications provided include: quoters are responsible for all transportation and shipping logistics with costs included in their quotes on an F.O.B. Destination basis; cylinders must be tested, certified, and returned within a 90-day performance period; quoters must develop and execute their own logistics approach for servicing all three locations; flow testing of harnesses is not included; filling of cylinders after hydrostatic testing is not required; and Cascade cylinder testing is excluded from scope. The requirement emphasizes that each fire department must maintain minimum operational quantities of cylinders on-site at all times to ensure continuous emergency services. All other terms and conditions of the original solicitation remain unchanged.

View the file

Other files

File Type Posted
WD 2015-5629 rev29 13MAY2026-San Bernardino.pdf PDF
WD 2015-5635 rev30 13MAY2026-San Diego.pdf PDF
M0068126Q0064.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

16C. DATE SIGNED

Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBE

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

Block 14 (Description of Amendment/Modification): The purpose of this amendment is to provide answers to questions received from industry and extend the solicitation quote/proposal due date.

A. QUESTIONS AND ANSWERS:

Question #1: Will shipping be arranged by the Navy or does this need to be included in the estimate?

Answer #1: Shipping will not be arranged by the Government. Quoters are responsible for the transportation and shipping logistics of the cylinders.

The Quoter must include all shipping and transportation costs in their quote. All deliveries shall be F.O.B. Destination, in accordance with Page 1 Block 11 of the solicitation.

Question #2: How many shipments of cylinders will there be?

Answer #2: There is a total of 548 cylinders distributed across the 3 Fire & Emergency Services located aboard Camp Pendleton, Miramar, and Barstow as stated in the PWS. Per Section L6.3.2 b) of the solicitation, the Quoter is responsible for the logistics of servicing all three (3) locations Quoters shall propose their technical approach to completing the requirement, ensuring all cylinders are tested, certified and returned before the end of the 90-day window.

Question #3: Would the cylinders be shipped from the three separate locations: San Diego, Miramar and Barstow?

Answer #3: It is the Quoter's responsibility to determine and execute the logistics and shipping methods from three (3) designated locations.

Question #4: Is there another request for flow testing the harnesses associated with these air packs?

Answer #4: No. Flow testing of harnesses is not included in this requirement.

Question #5: Will these be a one-time shipment from each location with the quantities outlined in the PWS?

Answer #5: See response in Answer #2. Quoters are encouraged to provide their best technical approach to ensure complete testing is achieved within the 90-day period of performance. Please note that each fire department will require a minimum operational quantity of cylinders to remain on-site in at all times to maintain continuous emergency services.

Question #6: Are cylinders required to be filled after hydrostatic testing prior to shipping?

Answer #6: Filling of cylinders is not required.

Question #7: Will the Cascade cylinders used to fill the carbon cylinders require hydrostatic testing as well?

Answer #7: The testing of Cascade cylinders are not included in this requirement.

B. PROPOSAL/QUOTATION DUE DATE EXTENSION:

As a result of this amendment, the solicitation proposal/quotation due date is hereby extended to Monday, 17 August 2026 at 12:30 PM Pacific.

C. All other terms and conditions remain unchanged.

Section A - Solicitation/Contract Form

The following changes have been made:

INFORMATION FROM TO

Response Due Date 14 Aug 2026 17 Aug 2026

M0068126Q00640001

IDCode: J
Page: 1
Pages: 2
AmendNo: 0001
EffDate: 11 Aug 2026
ReqNo: See Continuation Sheet
ProjNo:
IssCode: M00681
AdmCode:
IssuedBy: COMMANDING GENERAL

MARINE CORPS BASE, BOX 555013

CAMP PENDLETON, CA 92055-5001

UNITED STATES

Corey Slivnik, Email: corey.slivnik@usmc.mil Telephone: 7605428245 AdminBy:

SCD: PAS:

ContractorNameAdd:
Code:
FacCode:
SolChg: 1
SolNo: M0068126Q0064
SolDate: 30 Jul 2026
AwardChg: Off
AwardNo:
AwardDate:
Amended: 1
OffrExt: 1
OffrNoEx: Off
NoCopies: 1
ApprData: See Section G - Contract Administration Data
ChgeOrd: Off
ChgeOrder:
Modify: Off
SuppAgre: Off
SuppAuth:
ModOthr: Off
OthrSpec:
NoReq: Off
Require: Off
Copies:
Descript: See Schedule
ContNameTitle:
CoNameTitle: Corey Slivnik
ContDate:
CODate: 11 Aug 2026

File details come from the government source that posted it. Updated .