M-2321C Final Solicitation Package.pdf

PDF 4 MB Posted

Attached to
YWCA Enclosed Parking
Solicitation number
M-2321C
Issued by
Garfield County, Eakly Town, Oklahoma

About this file

This document is a comprehensive solicitation package for the YWCA Enclosed Parking project (M-2321C) issued by the City of Enid, Oklahoma, in collaboration with the Oklahoma Department of Commerce through Community Development Block Grant, Coronavirus Round 2 Funding. The project involves constructing a fence around a portion of the parking lot located at 525 S. Quincy, with the primary scope of work focused on installing a fence per specified plans and specifications. The solicitation includes detailed bidding documents, proposal forms, contract terms, technical specifications, and required affidavits. The bid documents outline a single line item for fence installation, with the contractor expected to complete the project within a specified contract time frame.

The project is funded through a Community Development Block Grant with specific requirements for contractor compliance, including provisions for equal opportunity, minority and women's business participation, and adherence to federal and state regulations. The contract includes standard payment terms with 95% of estimated work value paid monthly, a 10% retainage policy, and final payment upon project completion and acceptance. Insurance requirements are comprehensive, including workers' compensation and general public liability coverage with specific minimum coverage amounts. The contractor will be responsible for providing performance, payment, and maintenance bonds, with a three-year maintenance period after project acceptance. Bid responses must include a 5% bid guaranty, and the project emphasizes local and small business participation, with additional considerations for minority-owned and women-owned business enterprises.

View the file

Other files

File Type Posted
Addendum 1 M-2321C.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT DOCUMENTS

AND

SPECIFICATIONS

FOR

YWCA Enclosed Parking M-2321C

City of Enid

State of Oklahoma

April, 2023

TABLE OF CONTENTS

Solicitation for Bids

Proposal

Plans and Specifications

Business Relationships Affidavit, Non-Collusion Affidavit

Payroll Affidavit, Invoice Affidavit

Notice of Award

Construction Contract

Notice to Proceed

General Conditions

Supplemental Conditions

Maintenance Bond, Performance Bond, Statutory Bond and Insurance

Requirements Federal Wage Rates and Federal Labor Standards

Equal Opportunity Provisions

Section 3 Requirements

State of Oklahoma Hold Harmless Clause

Certificate of Compliance with Air and Water Acts

Special Conditions Pertaining to Hazards, Safety Standards and Accident

Prevention

Certificate of Approval of Contracts and Bonds Exhibit C – Notification of Contract Award to US Department of Labor

Release of Claimants

Contractors and Subcontractor’s Payroll Agreement

Attorney’s Certificate

Additional Required Documents List

PROPOSAL

Proposal – Page 1

TO: The Honorable Mayor and Board of Commissioners The City of Enid, Garfield County, Oklahoma

Gentlemen:

Pursuant to the notice inviting proposals, the undersigned bidder herewith submits his proposal.

He declares he has carefully examined the Plans, Specifications and forms of Contract and bonds as set forth in the proceedings for:

YWCA Enclosed Parking M-2321C and that he has reached a full understanding of everything required on said Plans and Specifications, and that he has informed himself as to the kind and quantities of various materials to be furnished and/or the nature and location of the work to be done, and all other matters affecting the work.

The undersigned bidder proposes and agrees that if his proposal is accepted, to enter into contract with THE CITY OF ENID, on forms prescribed, with approved sureties, within seven (7) days, after notice of award to execute the Contract, and to furnish to the City a satisfactory Performance and Statutory Bond in the sum of 100% of the contract price, guaranteeing the faithful performance of the work and payment of bills.

To do any extra work not covered by the following schedule of prices or stipulated lump sum price which may be ordered by the Engineer and to accept as full compensation therefor such prices as may be agreed upon in writing by the Engineer and the Contractor in accordance with Section 108.04 of the General Provisions.

It is further agreed that the Contractor shall begin the work on the date as provided in these Specifications and to prosecute said work in such a manner as to complete all work contracted for within the number of calendar days submitted in the bid.

The Contractor shall take out and maintain public liability and OCP insurance in accordance with Section

106.25 of the General Provisions of the Specifications. A copy of said Specifications is now on file in the Office of the City Clerk of the City of Enid.

Upon completion of the Contract, the Contractor shall furnish to the City a satisfactory Maintenance Bond in the amount of 100% of the final contract price, guaranteeing the maintenance of the work for a period of THREE (3) years after acceptance by the City.

Accompanying this proposal is a proposal guaranty for 5% of the total bid, payable to the CITY OF ENID, OKLAHOMA, which is to be forfeited, as liquidated damages, if, in the event that this proposal is accepted, the undersigned shall fail to execute the contract and furnish satisfactory contract bond under the conditions and within the time specified in this proposal. Otherwise said proposal guaranty is to be returned to the undersigned.

Project Name: YWCA Enclosed Parking Project No.: M-2321C

Proposal – Page 2

Base Bid

Line No. Bid Item Description Quantity Unit Unit Price Extended Price

1 Install fence per plans and specifications 1 LS

Base Bid Total

Contract Time (Calendar Days)

Total Base Bid in Words:

Project Name: YWCA Enclosed Parking Project No.: M-2321C

Proposal – Page 3

A Bidder's Bond, Certified or Cashier's Check is enclosed in the amount of $______________, as required.

STATE OF )

) SS:

COUNTY OF )

___________________________________; of lawful age, being first duly sworn, upon his oath, deposes and says, that he executed the accompanying bid on behalf of the bidder named therein for the construction of the above improvement in THE CITY OF ENID, OKLAHOMA, that he had lawful authority so to do and that the bidder has not been a party to any collusion among bidders in restraint of freedom of competition by agreement to bid at a fixed price or to refrain from bidding; or with any State or City official or employee as to quantity, quality, or price in the prospective contract, or any other terms of said prospective contract; or in any discussions between bidders and any State or City officials concerning exchange of money or other thing of value for special consideration in the letting of a contract; said bidder has neither directly nor indirectly entered into any agreement, express or implied, with any bidder or bidders, having for its object the controlling of the price or amount of such bid or bids, the limiting of the bids or bidders, the parceling or farming out to any bidder or bidders, or other persons of any part of the contract or any part of the profits thereof and that he has not and will not divulge the sealed bid on such public improvement to any person whatsoever, except those having a partnership or other financial interest with him in said bid or bids, until after the sealed bid or bids are opened.

If partnership, give name and address of each partner

By:

Address:

Incorporated under the laws of the State of:

Subscribed and sworn to before me this _____ day of _______________________, 20____.

Notary Public

(SEAL)

My Commission Expires:

TABLE OF CONTENTS

SECTIONS PAGES

DIVISION 03 - CONCRETE

SECTION 032000 - CONCRETE REINFORCING 2

SECTION 033000 - CAST-IN-PLACE CONCRETE 3

DIVISION 04 - MASONRY

SECTION 042200 - CONCRETE UNIT MASONRY 4

DIVISION 05 - METALS

SECTION 055000 - METAL FABRICATIONS 3

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

SECTION 074213.13 - FORMED METAL WALL PANELS 3

SECTION 079200 - JOINT SEALANTS 4

DIVISION 09 - FINISHES

SECTION 099113 - EXTERIOR PAINTING 2

DIVISION 31 - EARTHWORK

SECTION 312000 - EARTH MOVING 4

SECTION 032000 - CONCRETE REINFORCING

PART 1 GENERAL

1.01 SUMMARY

A. Section Includes:

1. Steel reinforcement bars.

PART 2 PRODUCTS

2.01 STEEL REINFORCEMENT

A. Reinforcing Bars: ASTM A615/A615M, Grade 60 , deformed.

2.02 REINFORCEMENT ACCESSORIES

A. Bar Supports: Bolsters, chairs, spacers, and other devices for spacing, supporting, and fastening reinforcing bars and welded-wire reinforcement in place.

B. Steel Tie Wire: ASTM A1064/A1064M, annealed steel, not less than 0.0508 inch in diameter.

1. Finish: Plain.

2.03 FABRICATING REINFORCEMENT

A. Fabricate steel reinforcement according to CRSI's "Manual of Standard Practice."

PART 3 EXECUTION

3.01 PREPARATION

A. Clean reinforcement of loose rust and mill scale, earth, ice, and other foreign materials that reduce bond to concrete.

3.02 INSTALLATION OF STEEL REINFORCEMENT

A. Comply with CRSI's "Manual of Standard Practice" for placing and supporting reinforcement.

B. Accurately position, support, and secure reinforcement against displacement.

1. Locate and support reinforcement with bar supports to maintain minimum concrete cover.

2. Do not tack weld crossing reinforcing bars.

C. Preserve clearance between bars of not less than 1 inch, not less than one bar diameter, or not less than 1-1/3 times size of large aggregate, whichever is greater.

D. Provide concrete coverage in accordance with ACI 318.

E. Set wire ties with ends directed into concrete, not toward exposed concrete surfaces.

F. Splices: Lap splices as indicated on Drawings.

1. Bars indicated to be continuous, and all vertical bars shall be lapped not less than 36 bar diameters at splices, or 24 inches, whichever is greater.

2. Stagger splices in accordance with ACI 318.

YWCA Enclosed Parking 032000 - 1 CONCRETE REINFORCING

3.03 JOINTS

A. Construction Joints: Install so strength and appearance of concrete are not impaired, at locations indicated or as approved by Architect.

1. Place joints perpendicular to main reinforcement.

2. Continue reinforcement across construction joints unless otherwise indicated.

3. Do not continue reinforcement through sides of strip placements of floors and slabs.

3.04 INSTALLATION TOLERANCES

A. Comply with ACI 117.

END OF SECTION 032000

YWCA Enclosed Parking 032000 - 2 CONCRETE REINFORCING

SECTION 033000 - CAST-IN-PLACE CONCRETE

1.01 SUMMARY

A. Section Includes:

1. Cast-in-place concrete, including concrete materials, mixture design, placement procedures, and finishes.

1.02 DEFINITIONS

A. Cementitious Materials: Portland cement alone or in combination with one or more of the following: blended hydraulic cement, fly ash, slag cement, and other pozzolans materials subject to compliance with requirements.

B. Water/Cement Ratio (w/cm): The ratio by weight of water to cementitious materials.

1.03 DELIVERY, STORAGE, AND HANDLING

A. Comply with ASTM C94/C94M and ACI 301.

1.04 FIELD CONDITIONS

A. Cold-Weather Placement: Comply with ACI 301 and ACI 306.1.

B. Hot-Weather Placement: Comply with ACI 301 and ACI 305.1.

PART 2 PRODUCTS

2.01 CONCRETE, GENERAL

A. ACI Publications: Comply with ACI 301 unless modified by requirements in the Contract Documents.

2.02 CONCRETE MATERIALS

A. Cementitious Materials:

1. Portland Cement: ASTM C150/C150M, Type I , [gray] [white].

2. Fly Ash: ASTM C618, Class C or F.

B. Normal-Weight Aggregates: ASTM C33/C33M, Class 3S coarse aggregate or better, graded. Provide aggregates from a single source.

1. Maximum Coarse-Aggregate Size: 1-1/2 inches nominal.

2. Fine Aggregate: Free of materials with deleterious reactivity to alkali in cement.

C. Air-Entraining Admixture: ASTM C260/C260M.

D. Chemical Admixtures: Certified by manufacturer to be compatible with other admixtures that do not contribute water-soluble chloride ions exceeding those permitted in hardened concrete. Do not use calcium chloride or admixtures containing calcium chloride [in steel-reinforced concrete].

1. Water-Reducing Admixture: ASTM C494/C494M, Type A.

2. Retarding Admixture: ASTM C494/C494M, Type B.

3. Water-Reducing and -Retarding Admixture: ASTM C494/C494M, Type D.

4. High-Range, Water-Reducing Admixture: ASTM C494/C494M, Type F.

5. High-Range, Water-Reducing and -Retarding Admixture: ASTM C494/C494M, Type G.

YWCA Enclosed Parking 033000 - 1 CAST-IN-PLACE CONCRETE

6. Plasticizing and Retarding Admixture: ASTM C1017/C1017M, Type II.

2.03 CURING MATERIALS

A. Water: Potable or complying with ASTM C1602/C1602M.

B. Clear, Waterborne, Membrane-Forming, Dissipating Curing Compound:

ASTM C309, Type 1, Class B.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. ChemMasters, Inc.

b. SpecChem, LLC.

c. W.R. Meadows, Inc.

2.04 RELATED MATERIALS

A. Expansion- and Isolation-Joint-Filler Strips: ASTM D1751, asphalt-saturated cellulosic fiber.

2.05 CONCRETE MIXTURES, GENERAL

A. Prepare design mixtures for each type and strength of concrete, proportioned on the basis of laboratory trial mixture or field test data, or both, in accordance with

ACI 301.

1. Use a qualified testing agency for preparing and reporting proposed mixture designs, based on laboratory trial mixtures.

B. Admixtures: Use admixtures in accordance with manufacturer's written instructions.

2.06 CONCRETE MIXTURES

A. Class A: Normal-weight concrete used for footings, grade beams, and tie beams.

1. Minimum Compressive Strength: 3000 psi at 28 days.

2. Slump Limit: 4 inches, plus or minus 1 inch.

B. Class B: Normal-weight concrete used for exterior slabs on grade

1. Minimum Compressive Strength: 3500 psi at 28 days

2. Slump Limit: 4 inches, plus or minus 1 inch.

3. Air Content: 4.5 percent plus or minus 1.5 percent at point of delivery of concrete

2.07 CONCRETE MIXING

A. Ready-Mixed Concrete: Measure, batch, mix, and deliver concrete in accordance with ASTM C94/C94M, and furnish batch ticket information.

PART 3 EXECUTION

3.01 JOINTS

A. Construct joints true to line, with faces perpendicular to surface plane of concrete.

B. Control Joints in Slabs-on-Ground: Form weakened-plane control joints, sectioning concrete into areas as indicated. Construct control joints for a depth equal to at least one-fourth of concrete thickness as follows:

1. Sawed Joints: Form control joints with power saws equipped with shatterproof abrasive or diamond-rimmed blades. Cut 1/8-inch- wide joints into concrete when cutting action does not tear, abrade, or otherwise damage surface and before concrete develops random cracks.

YWCA Enclosed Parking 033000 - 2 CAST-IN-PLACE CONCRETE http://www.specagent.com/LookUp/?ulid=11026&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457149615&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457149623&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457149621&mf=04&src=wd

C. Isolation Joints in Slabs-on-Ground: After removing formwork, install joint-filler strips at slab junctions with vertical surfaces, such as column pedestals, foundation walls, grade beams, and other locations, as indicated.

1. Extend joint-filler strips full width and depth of joint, terminating flush with finished concrete surface unless otherwise indicated on Drawings.

2. Terminate full-width joint-filler strips not less than 1/2 inch or more than 1 inch below finished concrete surface, where joint sealants, specified in Section 079200 "Joint Sealants," are indicated.

3. Install joint-filler strips in lengths as long as practicable. Where more than one length is required, lace or clip sections together.

3.02 CONCRETE PLACEMENT

A. Before placing concrete, verify that installation of formwork, reinforcement, embedded items, and vapor retarder is complete and that required inspections are completed.

B. Notify Architect and testing and inspection agencies 24 hours prior to commencement of concrete placement.

C. Do not add water to concrete during delivery, at Project site, or during placement unless approved by Architect in writing, but not to exceed the amount indicated on the concrete delivery ticket.

D. Deposit concrete continuously in one layer or in horizontal layers of such thickness that no new concrete is placed on concrete that has hardened enough to cause seams or planes of weakness.

1. If a section cannot be placed continuously, provide construction joints as indicated.

2. Deposit concrete to avoid segregation.

3. Deposit concrete in horizontal layers of depth not to exceed formwork design pressures and in a manner to avoid inclined construction joints.

3.03 CONCRETE CURING

A. Protect freshly placed concrete from premature drying and excessive cold or hot temperatures.

1. Comply with ACI 301 and ACI 306.1 for cold weather protection during curing.

2. Comply with ACI 301 and ACI 305.1 for hot-weather protection during curing.

3.04 TOLERANCES

A. Conform to ACI 117.

END OF SECTION 033000

YWCA Enclosed Parking 033000 - 3 CAST-IN-PLACE CONCRETE

SECTION 042200 - CONCRETE UNIT MASONRY

1.01 SUMMARY

A. Section Includes:

1. Concrete masonry units.

2. Steel reinforcing bars.

1.02 DEFINITIONS

A. CMU(s): Concrete masonry unit(s).

B. Reinforced Masonry: Masonry containing reinforcing steel in grouted cells.

1.03 FIELD CONDITIONS

A. Cold-Weather Requirements: Do not use frozen materials or materials mixed or coated with ice or frost. Do not build on frozen substrates. Remove and replace unit masonry damaged by frost or by freezing conditions. Comply with cold-weather construction requirements contained in TMS 602/ACI 530.1/ASCE 6.

B. Hot-Weather Requirements: Comply with hot-weather construction requirements contained in TMS 602/ACI 530.1/ASCE 6.

PART 2 PRODUCTS

2.01 UNIT MASONRY, GENERAL

A. Masonry Standard: Comply with TMS 602/ACI 530.1/ASCE 6, except as modified by requirements in the Contract Documents.

B. Defective Units: Referenced masonry unit standards may allow a certain percentage of units to contain chips, cracks, or other defects exceeding limits stated. Do not use units where such defects are exposed in the completed Work.

2.02 CONCRETE MASONRY UNITS

A. Shapes: Provide shapes indicated and as follows, with exposed surfaces matching exposed faces of adjacent units unless otherwise indicated.

1. Provide special shapes for lintels, corners, jambs, sashes, movement joints, headers, bonding, and other special conditions.

B. Decorative CMUs: ASTM C90.

1. Unit Compressive Strength: Provide units with minimum average net-area compressive strength of 2150 psi.

2. Density Classification: Lightweight.

3. Pattern and Texture:

a. Scored vertically, standard finish.

2.03 MORTAR AND GROUT MATERIALS

A. Portland Cement: ASTM C150/C150M, Type I or II, except Type III may be used for cold-weather construction. Provide natural color or white cement as required to produce mortar color indicated.

B. Hydrated Lime: ASTM C207, Type S.

C. Portland Cement-Lime Mix: Packaged blend of portland cement and hydrated lime containing no other ingredients.

YWCA Enclosed Parking 042200 - 1 CONCRETE UNIT MASONRY

D. Masonry Cement: ASTM C91/C91M.

E. Aggregate for Mortar: ASTM C144.

F. Aggregate for Grout: ASTM C404.

G. Cold-Weather Admixture: Nonchloride, noncorrosive, accelerating admixture complying with ASTM C494/C494M, Type C, and recommended by manufacturer for use in masonry mortar of composition indicated.

H. Water: Potable.

2.04 REINFORCEMENT

A. Uncoated-Steel Reinforcing Bars: ASTM A615/A615M or ASTM A996/A996M, Grade 60.

2.05 MORTAR AND GROUT MIXES

A. General: Do not use admixtures, including pigments, air-entraining agents, accelerators, retarders, water-repellent agents, antifreeze compounds, or other admixtures unless otherwise indicated.

B. Mortar for Unit Masonry: Comply with ASTM C270, Proportion Specification.

Provide the following types of mortar for applications stated unless another type is indicated.

1. For masonry below grade or in contact with earth, use Type S.

2. For reinforced masonry, use Type N.

3. For exterior, above-grade, load-bearing and nonload-bearing walls and parapet walls; for interior load-bearing walls; for interior nonload-bearing partitions; and for other applications where another type is not indicated, use Type N.

C. Grout for Unit Masonry: Comply with ASTM C476.

1. Use grout of type indicated or, if not otherwise indicated, of type (fine or coarse) that will comply with TMS 602/ACI 530.1/ASCE 6 for dimensions of grout spaces and pour height.

2. Proportion grout in accordance with ASTM C476, Table 1.

3. Provide grout with a slump of 8 to 11 inches as measured according to

ASTM C143/C143M.

PART 3 EXECUTION

3.01 INSTALLATION, GENERAL

A. Use full-size units without cutting if possible. If cutting is required to provide a continuous pattern or to fit adjoining construction, cut units with motor-driven saws; provide clean, sharp, unchipped edges. Allow units to dry before laying unless wetting of units is specified. Install cut units with cut surfaces and, where possible, cut edges concealed.

3.02 TOLERANCES

A. Dimensions and Locations of Elements:

1. For dimensions in cross section or elevation, do not vary by more than plus 1/2 inch or minus 1/4 inch.

2. For location of elements in plan, do not vary from that indicated by more than plus or minus 1/2 inch.

YWCA Enclosed Parking 042200 - 2 CONCRETE UNIT MASONRY

3. For location of elements in elevation, do not vary from that indicated by more than plus or minus 1/4 inch in a story height or 1/2 inch total.

B. Lines and Levels:

1. For bed joints and top surfaces of bearing walls, do not vary from level by more than 1/4 inch in 10 feet, or 1/2-inch maximum.

2. For conspicuous horizontal lines, such as lintels, sills, parapets, and reveals, do not vary from level by more than 1/8 inch in 10 feet, 1/4 inch in 20 feet, or 1/2-inch maximum.

3. For vertical lines and surfaces, do not vary from plumb by more than 1/4 inch in 10 feet, 3/8 inch in 20 feet, or 1/2-inch maximum.

4. For conspicuous vertical lines, such as external corners, door jambs, reveals, and expansion and control joints, do not vary from plumb by more than 1/8 inch in 10 feet, 1/4 inch in 20 feet, or 1/2-inch maximum.

5. For lines and surfaces, do not vary from straight by more than 1/4 inch in 10 feet, 3/8 inch in 20 feet, or 1/2-inch maximum.

C. Joints:

1. For bed joints, do not vary from thickness indicated by more than plus or minus 1/8 inch, with a maximum thickness limited to 1/2 inch.

2. For head and collar joints, do not vary from thickness indicated by more than plus 3/8 inch or minus 1/4 inch.

3. For exposed head joints, do not vary from thickness indicated by more than plus or minus 1/8 inch.

3.03 MORTAR BEDDING AND JOINTING

A. Lay hollow CMUs as follows:

1. Bed face shells in mortar and make head joints of depth equal to bed joints.

2. Bed webs in mortar in all courses of piers, columns, and pilasters.

3. Bed webs in mortar in grouted masonry, including starting course on footings.

4. Fully bed entire units, including areas under cells, at starting course on footings where cells are not grouted.

B. Lay solid CMUs with completely filled bed and head joints; butter ends with sufficient mortar to fill head joints and shove into place. Do not deeply furrow bed joints or slush head joints.

C. Tool exposed joints slightly concave when thumbprint hard, using a jointer larger than joint thickness unless otherwise indicated.

3.04 MASONRY-JOINT REINFORCEMENT

A. General: Install entire length of longitudinal side rods in mortar with a minimum cover of 5/8 inch on exterior side of walls, 1/2 inch elsewhere. Lap reinforcement a minimum of 6 inches.

1. Space reinforcement not more than 16 inches o.c.

2. Space reinforcement not more than 8 inches o.c. in foundation walls and parapet walls.

3. Provide reinforcement not more than 8 inches above and below wall openings and extending 12 inches beyond openings[ in addition to continuous reinforcement].

B. Interrupt joint reinforcement at control and expansion joints unless otherwise indicated.

C. Provide continuity at wall intersections by using prefabricated T-shaped units.

YWCA Enclosed Parking 042200 - 3 CONCRETE UNIT MASONRY

D. Provide continuity at corners by using prefabricated L-shaped units.

3.05 REINFORCED UNIT MASONRY INSTALLATION

A. Placing Reinforcement: Comply with requirements in

TMS 602/ACI 530.1/ASCE 6.

B. Grouting: Do not place grout until entire height of masonry to be grouted has attained enough strength to resist grout pressure.

1. Comply with requirements in TMS 602/ACI 530.1/ASCE 6 for cleanouts and for grout placement, including minimum grout space and maximum pour height.

2. Limit height of vertical grout pours to not more than 60 inches .

3.06 REPAIRING, POINTING, AND CLEANING

A. In-Progress Cleaning: Clean unit masonry as work progresses by dry brushing to remove mortar fins and smears before tooling joints.

B. Final Cleaning: After mortar is thoroughly set and cured, clean exposed masonry as follows:

1. Test cleaning methods on sample wall panel; leave one-half of panel uncleaned for comparison purposes.

2. Clean concrete masonry by applicable cleaning methods indicated in

NCMA TEK 8-4A.

END OF SECTION 042200

YWCA Enclosed Parking 042200 - 4 CONCRETE UNIT MASONRY

SECTION 055000 - METAL FABRICATIONS

1.01 SUMMARY

A. Section Includes:

1. Miscellaneous steel framing and supports.

PART 2 PRODUCTS

2.01 METALS

A. Metal Surfaces, General: Provide materials with smooth, flat surfaces unless otherwise indicated. For metal fabrications exposed to view in the completed Work, provide materials without seam marks, roller marks, rolled trade names, or blemishes.

B. Steel Plates, Shapes, and Bars: ASTM A36/A36M.

C. Steel Tubing: ASTM A500/A500M, cold-formed steel tubing.

2.02 FASTENERS

A. General: Unless otherwise indicated, provide Type 304 stainless steel fasteners for exterior use and zinc-plated fasteners with coating complying with ASTM B633 or ASTM F1941/F1941M, Class Fe/Zn 5, at exterior walls. Select fasteners for type, grade, and class required.

B. Post-Installed Anchors: Torque-controlled expansion anchors or chemical anchors.

1. Material for Exterior Locations and Where Stainless Steel Is Indicated: Alloy Group 1 stainless steel bolts, ASTM F593, and nuts, ASTM F594.

2.03 MISCELLANEOUS MATERIALS

A. Universal Shop Primer: Fast-curing, lead- and chromate-free, universal modified-alkyd primer complying with MPI#79 and compatible with topcoat.

1. Use primer containing pigments that make it easily distinguishable from zinc-rich primer.

2.04 FABRICATION, GENERAL

A. Shop Assembly: Preassemble items in the shop to greatest extent possible.

Disassemble units only as necessary for shipping and handling limitations. Use connections that maintain structural value of joined pieces. Clearly mark units for reassembly and coordinated installation.

B. Cut, drill, and punch metals cleanly and accurately. Remove burrs and ease edges to a radius of approximately 1/32 inch unless otherwise indicated. Remove sharp or rough areas on exposed surfaces.

C. Form exposed work with accurate angles and surfaces and straight edges.

D. Weld corners and seams continuously to comply with the following:

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

YWCA Enclosed Parking 055000 - 1 METAL FABRICATIONS

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing[ and contour of welded surface matches that of adjacent surface].

E. Fabricate seams and other connections that are exposed to weather in a manner to exclude water. Provide weep holes where water may accumulate.

2.05 METAL BOLLARDS

A. Fabricate metal bollards from Schedule 40 steel pipe.

1. Cap bollards with preformed steel domed cap

B. Prime steel bollards with zinc-rich primer.

2.06 GENERAL FINISH REQUIREMENTS

A. Finish metal fabrications after assembly.

2.07 STEEL AND IRON FINISHES

A. Shop prime iron and steel items[ not indicated to be galvanized] unless they are to be embedded in concrete, sprayed-on fireproofing, or masonry, or unless otherwise indicated.

1. Shop prime with universal shop primer unless primers specified in Section 099600 "High-Performance Coatings" are indicated.

B. Preparation for Shop Priming: Prepare surfaces to comply with SSPC-SP 3, "Power Tool Cleaning."

1. Items Indicated to Receive Zinc-Rich Primer: SSPC-SP 6/NACE No. 3, "Commercial Blast Cleaning."

2. Items Indicated to Receive Primers Specified in Section 099600 "High-Performance Coatings": SSPC-SP 6/NACE No. 3, "Commercial Blast Cleaning."

3. Other Steel Items: SSPC-SP 3, "Power Tool Cleaning."

C. Shop Priming: Apply shop primer to comply with SSPC-PA 1, "Paint Application Specification No. 1: Shop, Field, and Maintenance Painting of Steel," for shop painting.

PART 3 EXECUTION

3.01 INSTALLATION, GENERAL

A. Cutting, Fitting, and Placement: Perform cutting, drilling, and fitting required for installing metal fabrications. Set metal fabrications accurately in location, alignment, and elevation; with edges and surfaces level, plumb, true, and free of rack; and measured from established lines and levels.

B. Fit exposed connections accurately together to form hairline joints. Weld connections that are not to be left as exposed joints but cannot be shop welded because of shipping size limitations. Do not weld, cut, or abrade surfaces of exterior units that have been hot-dip galvanized after fabrication and are for bolted or screwed field connections.

C. Field Welding: Comply with the following requirements:

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

YWCA Enclosed Parking 055000 - 2 METAL FABRICATIONS

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.

D. Fastening to In-Place Construction: Provide anchorage devices and fasteners where metal fabrications are required to be fastened to in-place construction.

Provide threaded fasteners for use with concrete and masonry inserts, toggle bolts, through bolts, lag screws, wood screws, and other connectors.

E. Provide temporary bracing or anchors in formwork for items that are to be built into concrete, masonry, or similar construction.

3.02 REPAIRS

A. Touchup Painting:

1. Immediately after erection, clean field welds, bolted connections, and abraded areas. Paint uncoated and abraded areas with same material as used for shop painting to comply with SSPC-PA 1 for touching up shop-painted surfaces.

END OF SECTION 055000

YWCA Enclosed Parking 055000 - 3 METAL FABRICATIONS

SECTION 074213.13 - FORMED METAL WALL PANELS

1.01 SUMMARY

A. Section Includes:

1. Exposed-fastener, lap-seam metal wall panels.

PART 2 PRODUCTS

2.01 EXPOSED-FASTENER, LAP-SEAM METAL WALL PANELS

A. Provide factory-formed metal panels designed to be field assembled by lapping side edges of adjacent panels and mechanically attaching panels to supports using exposed fasteners in side laps. Include accessories required for weathertight installation.

B. Trapezoidal Rib Profile, Exposed Fastener Metal Wall Panels: Formed with raised trapezoidal ribs at 7.2 inches on center

C. Manufacturer:

1. Berridge Manufacturing Company, product: Deep-Deck Panel

2. Approved equal

D. Metalic Coated Steel: Zinc coated (galvanized) steel sheet complying with ASTM A653, G90 coating designation, or aluminum zinc alloy coated steel sheet complying with ASTM A792, Class AZ50 coating designation; structural quality.

Prepainted by the coil coating process to comply with ASTM A755.

1. Nominal Thickness: 24 gauge

2. Exterior Finish: Three coat fluorpolymer

3. Color: as selected by the Architect from the Manufacturer's full range of standard colors

4. Rib spacing: 7.2 inches on center

5. Panel coverage: 36 inches

6. Panel height: 1 1/2 inches

2.02 CONCEALED-FASTENER, LAP-SEAM METAL WALL PANELS

A. Provide factory-formed metal panels designed to be field assembled by lapping and interconnecting side edges of adjacent panels and mechanically attaching through panel to supports using concealed fasteners in side laps. Include accessories required for weathertight installation.

2.03 MISCELLANEOUS MATERIALS

A. Flashing and Trim: Provide flashing and trim formed from same material as metal panels as required to seal against weather and to provide finished appearance.

Locations include, but are not limited to, bases, drips, sills, jambs, corners, endwalls, framed openings, rakes, fasciae, parapet caps, soffits, reveals, and fillers. Finish flashing and trim with same finish system as adjacent metal panels.

B. Panel Fasteners: Self-tapping screws designed to withstand design loads. Provide exposed fasteners with heads matching color of metal panels by means of plastic caps or factory-applied coating. Provide EPDM or PVC sealing washers for exposed fasteners.

YWCA Enclosed Parking 074213.13 - 1 FORMED METAL WALL PANELS

2.04 FABRICATION

A. Fabricate and finish metal panels and accessories at the factory, by manufacturer's standard procedures and processes, as necessary to fulfill indicated performance requirements demonstrated by laboratory testing. Comply with indicated profiles and with dimensional and structural requirements.

B. Sheet Metal Flashing and Trim: Fabricate flashing and trim to comply with manufacturer's recommendations and recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to design, dimensions, metal, and other characteristics of item indicated.

2.05 FINISHES

A. Panels and Accessories:

1. Three-Coat Fluoropolymer: [AAMA 621] [AAMA 2605]. Fluoropolymer finish containing not less than 70 percent polyvinylidene fluoride (PVDF) resin by weight in both color coat and clear topcoat.

2. Concealed Finish: White or light-colored acrylic or polyester backer finish.

PART 3 EXECUTION

3.01 PREPARATION

A. Miscellaneous Supports: Install subframing, furring, and other miscellaneous panel support members and anchorages according to ASTM C754 and metal panel manufacturer's written recommendations.

3.02 INSTALLATION

A. Lap-Seam Metal Panels: Fasten metal panels to supports with fasteners at each lapped joint at location and spacing recommended by manufacturer.

1. Lap ribbed or fluted sheets one full rib. Apply panels and associated items true to line for neat and weathertight enclosure.

2. Provide metal-backed washers under heads of exposed fasteners bearing on weather side of metal panels.

3. Locate and space exposed fasteners in uniform vertical and horizontal alignment. Use proper tools to obtain controlled uniform compression for positive seal without rupture of washer.

4. Install screw fasteners with power tools having controlled torque adjusted to compress washer tightly without damage to washer, screw threads, or panels.

Install screws in predrilled holes.

5. Flash and seal panels with weather closures at perimeter of all openings.

B. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual."

Provide concealed fasteners where possible, and set units true to line and level as indicated. Install work with laps, joints, and seams that are permanently watertight.

3.03 CLEANING

A. Remove temporary protective coverings and strippable films, if any, as metal panels are installed, unless otherwise indicated in manufacturer's written installation instructions. On completion of metal panel installation, clean finished surfaces as recommended by metal panel manufacturer. Maintain in a clean condition during construction.

YWCA Enclosed Parking 074213.13 - 2 FORMED METAL WALL PANELS

END OF SECTION 074213.13

YWCA Enclosed Parking 074213.13 - 3 FORMED METAL WALL PANELS

SECTION 079200 - JOINT SEALANTS

1.01 SUMMARY

A. Section Includes:

1. Urethane joint sealants.

PART 2 PRODUCTS

2.01 JOINT SEALANTS, GENERAL

A. Compatibility: Provide joint sealants, backings, and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as demonstrated by joint-sealant manufacturer, based on testing and field experience.

B. Colors of Exposed Joint Sealants: As selected by Architect from manufacturer's full range.

2.02 URETHANE JOINT SEALANTS

A. Urethane, S, NS, 25, NT: Single-component, nonsag, nontraffic-use, plus 25 percent and minus 25 percent movement capability, urethane joint sealant; ASTM C920, Type S, Grade NS, Class 25, Use NT.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Bostik, Inc.

b. Master Builders Solutions.

c. Pecora Corporation.

d. Sika Corporation; Joint Sealants.

e. Tremco Incorporated.

2. Reference Product: Tremco Dymonic

B. Urethane, M, P, 25, T, NT: Multicomponent, pourable, plus 25 percent and minus 25 percent movement capability, traffic- and nontraffic-use, urethane joint sealant;

ASTM C920, Type M, Grade P, Class 25, Uses T and NT.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Bostik, Inc.

b. Master Builders Solutions.

c. Pecora Corporation.

d. Sika Corporation; Joint Sealants.

e. Tremco Incorporated.

2. Reference Product: Tremco THC-901

2.03 JOINT-SEALANT BACKING

A. Sealant Backing Material, General: Nonstaining; compatible with joint substrates, sealants, primers, and other joint fillers; and approved for applications indicated by sealant manufacturer based on field experience and laboratory testing.

YWCA Enclosed Parking 079200 - 1 JOINT SEALANTS http://www.specagent.com/LookUp/?ulid=9414&mf=&src=wd http://www.specagent.com/LookUp/?uid=123457200742&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200741&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200743&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200749&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200747&mf=04&src=wd http://www.specagent.com/LookUp/?ulid=9424&mf=&src=wd http://www.specagent.com/LookUp/?uid=123457200765&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200770&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200767&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200771&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457200769&mf=04&src=wd

B. Cylindrical Sealant Backings: ASTM C1330, Type C (closed-cell material with a surface skin), and of size and density to control sealant depth and otherwise contribute to producing optimum sealant performance.

2.04 MISCELLANEOUS MATERIALS

A. Primer: Material recommended by joint-sealant manufacturer where required for adhesion of sealant to joint substrates indicated, as determined from preconstruction joint-sealant-substrate tests and field tests.

B. Masking Tape: Nonstaining, nonabsorbent material compatible with joint sealants and surfaces adjacent to joints.

PART 3 EXECUTION

3.01 PREPARATION

A. Surface Cleaning of Joints: Clean out joints immediately before installing joint sealants to comply with joint-sealant manufacturer's written instructions and the following requirements:

1. Remove all foreign material from joint substrates that could interfere with adhesion of joint sealant, including dust, paints (except for permanent, protective coatings tested and approved for sealant adhesion and compatibility by sealant manufacturer), old joint sealants, oil, grease, waterproofing, water repellents, water, surface dirt, and frost.

2. Clean porous joint substrate surfaces by brushing, grinding, mechanical abrading, or a combination of these methods to produce a clean, sound substrate capable of developing optimum bond with joint sealants. Remove loose particles remaining after cleaning operations above by vacuuming or blowing out joints with oil-free compressed air. Porous joint substrates include the following:

a. Concrete.

b. Masonry.

3. Remove laitance and form-release agents from concrete.

B. Joint Priming: Prime joint substrates where recommended by joint-sealant manufacturer or as indicated by preconstruction joint-sealant-substrate tests or prior experience. Apply primer to comply with joint-sealant manufacturer's written instructions. Confine primers to areas of joint-sealant bond; do not allow spillage or migration onto adjoining surfaces.

C. Masking Tape: Use masking tape where required to prevent contact of sealant or primer with adjoining surfaces that otherwise would be permanently stained or damaged by such contact or by cleaning methods required to remove sealant smears. Remove tape immediately after tooling without disturbing joint seal.

3.02 INSTALLATION OF JOINT SEALANTS

A. General: Comply with joint-sealant manufacturer's written installation instructions for products and applications indicated, unless more stringent requirements apply.

B. Sealant Installation Standard: Comply with recommendations in ASTM C1193 for use of joint sealants as applicable to materials, applications, and conditions indicated.

YWCA Enclosed Parking 079200 - 2 JOINT SEALANTS

C. Install sealant backings of type indicated to support sealants during application and at position required to produce cross-sectional shapes and depths of installed sealants relative to joint widths that allow optimum sealant movement capability.

1. Do not leave gaps between ends of sealant backings.

2. Do not stretch, twist, puncture, or tear sealant backings.

3. Remove absorbent sealant backings that have become wet before sealant application, and replace them with dry materials.

D. Install sealants using proven techniques that comply with the following and at the same time backings are installed:

1. Place sealants so they directly contact and fully wet joint substrates.

2. Completely fill recesses in each joint configuration.

3. Produce uniform, cross-sectional shapes and depths relative to joint widths that allow optimum sealant movement capability.

E. Tooling of Nonsag Sealants: Immediately after sealant application and before skinning or curing begins, tool sealants according to requirements specified in subparagraphs below to form smooth, uniform beads of configuration indicated; to eliminate air pockets; and to ensure contact and adhesion of sealant with sides of joint.

1. Remove excess sealant from surfaces adjacent to joints.

2. Use tooling agents that are approved in writing by sealant manufacturer and that do not discolor sealants or adjacent surfaces.

3. Provide concave joint profile in accordance with Figure 8A in ASTM C1193 unless otherwise indicated.

F. Clean off excess sealant or sealant smears adjacent to joints as the Work progresses by methods and with cleaning materials approved in writing by manufacturers of joint sealants and of products in which joints occur.

G. Protect joint sealants during and after curing period from contact with contaminating substances and from damage resulting from construction operations or other causes so sealants are without deterioration or damage at time of Substantial Completion. If, despite such protection, damage or deterioration occurs, cut out, remove, and repair damaged or deteriorated joint sealants immediately so installations with repaired areas are indistinguishable from original work.

3.03 JOINT-SEALANT SCHEDULE

A. Exterior joints in horizontal traffic surfaces subject to water immersion:

1. Joint Locations:

a. Joints in pedestrian plazas.

2. Joint Sealant: Urethane, immersible, S, P, 25, T, NT, I.

3. Joint-Sealant Color: As selected by Architect from manufacturer's full range of colors.

B. Exterior joints in vertical surfaces and horizontal nontraffic surfaces:

1. Joint Locations:

a. Control and expansion joints in unit masonry.

2. Joint Sealant: Urethane, S, NS, 25, NT.

3. Joint-Sealant Color: As selected by Architect from manufacturer's full range of colors.

YWCA Enclosed Parking 079200 - 3 JOINT SEALANTS

END OF SECTION 079200

YWCA Enclosed Parking 079200 - 4 JOINT SEALANTS

SECTION 099113 - EXTERIOR PAINTING

1.01 SUMMARY

A. Section Includes:

1. Primers.

2. Finish coatings.

1.02 QUALITY ASSURANCE

A. Mockups: Apply mockups of each paint system indicated and each color and finish selected to verify selections made under Sample submittals, to demonstrate aesthetic effects, and to set quality standards for materials and execution.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Behr Paint Company; Behr Process Corporation.

2. Benjamin Moore & Co.

3. Kelly-Moore Paint Company Inc.

4. PPG Paints.

5. Pratt & Lambert.

6. Sherwin-Williams Company (The).

7. Valspar Corporation (The).

2.02 PAINT PRODUCTS, GENERAL

A. Material Compatibility:

1. Provide materials for use within each paint system that are compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer based on testing and field experience.

2. For each coat in a paint system, provide products recommended in writing by topcoat manufacturer for use in paint system and on substrate indicated.

B. Colors: As selected by Architect from manufacturer's full range.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify suitability of substrates, including surface conditions and compatibility, with finishes and primers.

B. Proceed with coating application only after unsatisfactory conditions have been corrected.

1. Application of coating indicates acceptance of surfaces and conditions.

3.02 PREPARATION

A. Comply with manufacturer's written instructions applicable to substrates and paint systems indicated.

YWCA Enclosed Parking 099113 - 1 EXTERIOR PAINTING http://www.specagent.com/LookUp/?ulid=13985&mf=&src=wd http://www.specagent.com/LookUp/?uid=123457173994&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457173995&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457174001&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457174003&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457174004&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457174007&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123457174008&mf=04&src=wd

B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection.

C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease, and incompatible paints and encapsulants.

1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce paint systems specified in this Section.

3.03 INSTALLATION

A. Apply paints in accordance with manufacturer's written instructions.

B. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections.

Cut in sharp lines and color breaks.

3.04 CLEANING AND PROTECTION

A. After completing paint application, clean spattered surfaces. Remove spattered paints by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.

B. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition.

C. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces.

3.05 EXTERIOR PAINTING SCHEDULE

A. Concrete Masonry Unit Substrates:

1. Acrylic System :

a. Intermediate Coat: Matching topcoat.

b. Topcoat: Exterior latex paint, low sheen.

1) Loxon Vertical Concrete Stain, A31 Series by Sherwin Williams

B. Steel and Iron Substrates:

1. Alkyd System :

a. Prime Coat: Shop primer specified in Section in which substrate is specified.

b. Intermediate Coat: Matching topcoat.

c. Topcoat: Exterior alkyd enamel, semigloss.

1) Industrial Enamel by Sherwin Williams

C. Exterior Pavement Striping Paint

1. One Coat

END OF SECTION 099113

YWCA Enclosed Parking 099113 - 2 EXTERIOR PAINTING

SECTION 312000 - EARTH MOVING

1.01 SUMMARY

A. Section Includes:

1. Preparing subgrades for pavements.

2. Excavating and backfilling for buildings and structures.

1.02 DEFINITIONS

A. Backfill: Soil material used to fill an excavation.

1. Initial Backfill: Backfill placed beside and over pipe in a trench, including haunches to support sides of pipe.

2. Final Backfill: Backfill placed over initial backfill to fill a trench.

B. Borrow Soil: Satisfactory soil imported from off-site for use as fill or backfill.

C. Excavation: Removal of material encountered above subgrade elevations and to lines and dimensions indicated.

1. Authorized Additional Excavation: Excavation below subgrade elevations or beyond indicated lines and dimensions as directed by Architect. Authorized additional excavation and replacement material will be paid for according to Contract provisions for changes in the Work.

2. Unauthorized Excavation: Excavation below subgrade elevations or beyond indicated lines and dimensions without direction by Architect. Unauthorized excavation, as well as remedial work directed by Architect, shall be without additional compensation.

D. Fill: Soil materials used to raise existing grades.

E. Structures: Buildings, footings, foundations, retaining walls, slabs, tanks, curbs, mechanical and electrical appurtenances, or other man-made stationary features constructed above or below the ground surface.

F. Subgrade: Uppermost surface of an excavation or the top surface of a fill or backfill immediately below subbase, drainage fill, drainage course, or topsoil materials.

G. Utilities: On-site underground pipes, conduits, ducts, and cables as well as underground services within buildings.

1.03 FIELD CONDITIONS

A. Utility Locator Service: Notify utility locator service for area where Project is located before beginning earth-moving operations.

PART 2 PRODUCTS

2.01 SOIL MATERIALS

A. General: Provide borrow soil materials when sufficient satisfactory soil materials are not available from excavations.

B. Satisfactory Soils: Soil Classification Groups GW, GP, GM, SW, SP, and SM according to ASTM D2487, or a combination of these groups; free of rock or gravel larger than 2 inches in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter.

YWCA Enclosed Parking 312000 - 1 EARTH MOVING

1. Liquid Limit: 40 percent, maximum.

2. Plasticity Index: range of 5-15.

C. Unsatisfactory Soils: Soil Classification Groups GC, SC, CL, ML, OL, CH, MH, OH, and PT according to ASTM D2487, or a combination of these groups.

1. Unsatisfactory soils also include satisfactory soils not maintained within 2 percent of optimum moisture content at time of compaction.

D. Subbase Material: Naturally or artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM D2940/D2940M; with at least 90 percent passing a 1-1/2-inch sieve and not more than 12 percent passing a No. 200 sieve.

E. Base Course: Naturally or artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM D2940/D2940M; with at least 95 percent passing a 1-1/2-inch sieve and not more than 8 percent passing a No. 200 sieve.

F. Engineered Fill: Naturally or artificially graded mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM D2940/D2940M; with at least 90 percent passing a 1-1/2-inch sieve and not more than 12 percent passing a No. 200 sieve.

PART 3 EXECUTION

3.01 PREPARATION

A. Protect structures, utilities, sidewalks, pavements, and other facilities from damage caused by settlement, lateral movement, undermining, washout, and other hazards created by earth-moving operations.

B. Protect and maintain erosion and sedimentation controls during earth-moving operations.

C. Protect subgrades and foundation soils from freezing temperatures…