LRWRP_Design_Report_Appendix_C.pdf

PDF 29 MB Posted

Attached to
HEADWORKS and INFLUENT METER IMPROVEMENTS PROJECT
Solicitation number
2025-RFP-015DW
Issued by
Santa Barbara County, Long Beach City, California

About this file

The document is a technical design report appendix for the Lompoc Regional Wastewater Reclamation Plant, specifically focusing on pump specifications for the Influent Pumping Station. The file contains detailed engineering drawings and pump data sheets for two pump models: a Fairbanks Morse 60 Hz pump and a Morris Pumps model, both designed for wastewater handling. The pumps are part of the City of Lompoc's Headworks and Influent Meter Improvements Project, with bid proposals being accepted until 3:00 pm on Monday, June 30, 2025, and proposal validity set for 90 calendar days after the bid opening date.

The pump specifications include detailed performance metrics such as flow rates (5,210 US gpm for Fairbanks Morse, 7.5 mgd for Morris Pumps), head measurements, efficiency ratings, and motor specifications. The design documents provide technical details on inlet piece construction, including steel plate requirements, fabrication specifications, and installation guidelines. While specific budget or funding sources are not explicitly detailed in this appendix, the document appears to be a critical technical component supporting the municipal infrastructure improvement project for Lompoc's wastewater treatment facility.

View the file

Other files

File Type Posted
LRWRP_Design_Report_Chapter_10.pdf PDF
LRWRP_Design_Report_Chapter_8.pdf PDF
LRWRP_Design_Report_Chapter_3.pdf PDF
LRWRP_Design_Report_Chapter_7.pdf PDF
LRWRP_Design_Report_Chapter_8.pdf PDF
LRWRP_Design_Report_Chapter_9.pdf PDF
LRWRP_Design_Report_Chapter_3.pdf PDF
LRWRP_Design_Report_Chapter_4.pdf PDF
LRWRP_Design_Report_TOC.pdf PDF
LRWRP_Design_Report_Cover_Page.pdf PDF
Lompoc_Salts_Mgt_Plan_010611.pdf PDF
LRWRP_Design_Report_Chapter_3.pdf PDF
LRWRP_Design_Report_Chapter_4.pdf PDF
LRWRP_Design_Report_Chapter_5.pdf PDF
LRWRP_Design_Report_TOC.pdf PDF
LRWRP_Design_Report_Chapter_9.pdf PDF
LRWRP_Design_Report_Cover_Page.pdf PDF
Lompoc_Salts_Mgt_Plan_010611.pdf PDF
LRWRP_Design_Report_Chapter_10.pdf PDF
LRWRP_Design_Report_Appendix_D.pdf PDF
LRWRP_Design_Report_Appendix_E.pdf PDF
LRWRP_Design_Report_Appendix_A.pdf PDF
LRWRP_Design_Report_Chapter_1.pdf PDF
Vol.II_Appendices.pdf PDF
LRWRP_Design_Report_Appendix_D.pdf PDF
LRWRP_Design_Report_Chapter_1.pdf PDF
LRWRP_Design_Report_Chapter_2.pdf PDF
Lompoc_Wastewater_Master_Plan_Volume_II_-_Appendices.pdf PDF
Vol.II_Appendices.pdf PDF
LRWRP_Design_Report_Chapter_1.pdf PDF
LRWRP_Design_Report_Chapter_2.pdf PDF
Lompoc_Wastewater_Master_Plan_Volume_I_-_Report.pdf PDF
LRWRP_Design_Report_Appendix_F.pdf PDF
LRWRP_Design_Report_Chapter_2.pdf PDF
Vol.I_MasterPlan.pdf PDF
LRWRP_Design_Report_Appendix_F.pdf PDF
Vol.I_MasterPlan.pdf PDF
LRWRP_Design_Report_Appendix_A.pdf PDF
LRWRP_Design_Report_Appendix_F.pdf PDF
Lompoc_Wastewater_Master_Plan.pdf PDF
Lompoc_Wastewater_Master_Plan_Volume_III_-_Executive_Summary.pdf PDF
LRWRP_Design_Report_Appendix_B.pdf PDF
LRWRP_Design_Report_Appendix_C.pdf PDF
LRWRP_Design_Report_Appendix_D.pdf PDF
LRWRP_Design_Report_Appendix_E.pdf PDF
Consultant_Services_Agreement_2025.doc DOC document
Consultant_Services_Agreement_2025.doc DOC document
Consultant_Services_Agreement_2025.doc DOC document
INDEMNITY_AND_INSURANCE_REQUIREMENTS.docx DOCX document
INDEMNITY_AND_INSURANCE_REQUIREMENTS.docx DOCX document
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX C

Alternative A - Existing Pumping Station

PLAN AT EL 52.0

SCALE : I/; = 1' 0

I i

P 7 . { d AND C A L D W E L L ' w S 337 M LOMPOC REGIONAL

APTROYED'

CONSULTING ENGINEES

Y ? l SAN FRAMCISCO. ALHAWLA, wmauu ,MAR.1974 ( WASTEWATER RECLAMATION PLANT

FABRICATED PUMP I

SECTION @ @ SEE. DWO 5205

SCALE a '/s" = 1'-0

SEE

SCALE : I// = 1'- 0

SCALE : l/al= 1'-0 jl-

,J

SAN FRANCISCO - ALMA

PLAN AT EL 68.0

SCALE8 '4'' = 1'- 0

I FOR CONi

SEE MTG 69 PLAN AT EL 96.0

SCALE: 1/4''= 1'-0

THICKENER

I

FMPC

Brant Williams Lompoc Shafted Non Clog Option

-,I y: 111408A

PUMP DATA SHEET

Fairbanks Morse Pump, 60 Hz

Design Point: Flow: 521 0 US gprn Head: 29 ft

I pump: 5700ANGLEFLO - 900 Size: 14"5711 (A)

Speed: 885 rpm Dia: 14.9375 in limits: Temperature: 150 "F

Pressure: 50 psig

.Fpecific Speed: Ns: 4135 bimensions: Suction: 14 in

Sphere size: 5.25 in Power: --- bhp

Nss: 8653

Discharge: 14 in

.Motor: 50 hp Speed: 900 Frame: 404T

1 NEMA Standard TEFC Enclosure sized for Max Power on Design Curve

---- Data Point ---- Flow: 5210 US gprn

Head: 29.4 ft

Eff: 82%

Power: 47.3 bhp

NPSHr: 11.4 ft

- Design Curve --i ahutoff Head: 46.6 ft

Shutoff dP: 20.2 psi

Min Flow: 1500 US gprn

BEP: 82% eff @ 5492 US gprn

NOL Pwr: 47.6 bhp @ 5492 US gprn

-- Max Curve -- Max Pwr: 98.8 bhp

@ 8240 US gprn

Flow Speed

USgpm rPm 6252 885 521 0 885 4168 885 3126 885 2084 885

H20ptimize ver: 6.041 1 011 4/04

Selection file: (untitled)

Catalog: FMCENT6O.MPC v 2.0

Fluid: Water Temperature: 60 "F

SG: 1

Viscosity: 1 .I 22 CP Vapor pressure: 0.2568 psia Aim pressure: 14.7 psia

NPSHa: --- ft Piping: System: ---

Suction: -- in Discharge: -- in

US gpm two 1600 2400 3200 4000 4800 5600 6400 7200

--- PERFORMANCE EVALUATION ---

Head Pump Power NPSHr Motor Motor Hrslyr Cost ft %eff bhp ft %eff kW /kwh

24 8 1 46.8 14.9

29.4 82 47.3 11.4

33.5 78 45.3 . 9.54 37 67 43.3 9

39.9 51 40.9 9

NEW PAGE

CO-

N

7- \NOTES - WM) INLET PIECES:

'1. STEEL PLATE SHALL CONFORM TO THE REQUIREK~S OF ASTM. A36 OR A W . GRADE C .

2. PLATE THICKNESS SHALL BE 3/8". WCEPT WHERE NOTED.

C54 INl.67

3. ALL ,FABRICATIWJ SHALL BE I N ACcEDANCE W/ AWWA SPECIFICATION C201..

6. CONTRACTOR SHALL 'PROVIDE bJi NECESSARY SUPPORTS AEP) INTERNAL BRACIffi TO

PREVENT DAMAGE OR DISTORTION OF IN-ET PIECES WRING WURMO OF THE FWATION

SUB. AFTER CONCRETE ARWND INLET PIECES HAS CURED. FILL ALL VOID SPACES

?EN WRm AND STEEL W/ GROUT UMER PRESSURE. .

7. REPLACE STEEL PLUGS AFTER GROUTING AM3 GRIND SMOOTH.

SHALL BE F I R D COATED. ALL WORK SHALL

BE I N ACCORDANCE W/

9. PROVIM CMILING SF8

DETAIL @

SCALE: I h"= 1'-0

S E C T I O N @ a S C A L E : 3/eU=I'-0

PUMP 'BASE AND INLET PIECE

P L A N

S C A L E : I%* 8 1'-0

STEEL SO66 PLATE .THICKNESS Y L ~ G T H AS R W ~ ' BY M F ~

SECTION @

SCALE: 1 1/2"= 1'-0

SCALE: I I/$= ~ ' f o f HIS DRAWING REDUCED

TO HALF SIZE

INFLUENT PUMPING STATION C REGIONAL .

RECLAMATION PLANT . PLANS, SECTION AND DETAIL

-ompoc Treatment Plant PUMP DATA SHEET

Morris Pumps, Aurora, IL

Selection list: ---rch Criteria:

,:low: 7.5 mgd Head: 30 ft Tolerance: -- % of head

Fluid: Water Temperature: 60 OF

SG: 1

Viscosity: 1 .I 05 CP Vapor pressure: 0.2563 psi a Atm pressure: 14.7 psi a

NPSHa: --ft

Advanced Criteria:

Preferred Operating Area: --- Secondary Operating Point: -- Max temperature: - "F Max suction pressure: - psi g Max sphere size: -- in Max power: --- bhp Max suction specific speed: --- (Nss) Min trim: -- % of max diameter Min head rise: -- % to shutoff

Curve Corrections: none

I ---- Data Point ----

Flow: 7.5 mgd

Head: 30.1 ft

Eff: 81%

Power: 48.5 bhp

NPSHr: 10.6 ft

I -- Design Cu we --

Shutoff Head: 53.1 ft

Shutoff dP: 23 psi

Min Flow: -- mgd

BEP: 85% eff @ 6.13 mgd

NOL Pwr: 48.6 bhp @ 7.96 mgd

Catalog: 7100 Heavy Duty Wastewater 60Hz vers .I

Pump: 1214193V Type: 7100EC Synch speed: 720 rpm Speed: 700 rprn Dia: 19.12 in Curve no.: BM-10648

Specific Speeds Ns: 3023

Dimensions:

Suction: 14 in

Nss: 10109

Pump Limits:

Temperature: 150 "F Pressure: 67 psi g Sphere size: 3.9 in Power: -- bhp

Motor: -- h~

Discharge: 12 in

I Max Pwr: 48.6 bhp @ 7.96 mgd

Speed: -- Frame: -- Standard: NEMA Enclosure: TEFC Sizing criteria: Max Power on Design Curve

PumpfinderPlus vers 7.1