- Solicitation number
- S-24800-00006295
- Issued by
- Multnomah County, Oregon
About this file
This document is a Request for Quote (RFQ) for the inspection of boilers at the Oregon National Guard Air National Guard (PANG) in various buildings located across Multnomah County and the City of Portland. The project requires all labor and materials as detailed in the RFQ. Bidders are requested to provide unit pricing for the listed boilers, which include details such as manufacturer, model, serial number, fuel type, operating pressure, relief valve pressure, burner information, and installation year. Bids should be submitted with pricing in the last column of the provided boiler list.
The contract term and any renewal options are not specified. The RFQ does not mention any set-asides, incumbent contractors, funding requirements, or other salient pricing or financial information. Bidders are advised to review the complete RFQ document for full details and requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ Boiler Inspections 23-006Q final for posting.pdf | ||
| List of UPVs 2023 final for posting.xlsx | XLSX spreadsheet | |
| spider box bid.pdf | ||
| surplus vehicle sale notice.docx | DOCX document | |
| Abstract of Bids 23-006Q final for posting.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| PANG BOILER LIST | Total $$ | ||||||||||||||||
| $0.00 | |||||||||||||||||
| BLDG | Manufacture | Model | S/N | Fuel | Operating Press | Relief Valve | Op. Control | High Limit | Burner Make | Burner Model # | Input But's | National Board # | Comments | Installed | Notes | BID Price $ | |
| 115 | Burnham | FB12 | CP34000081 | Nat. Gas | 23 psi | 30 psi | 165-190 | 210 | Power Flame | J15A-10 | 700,000 | Unable to find NB# | 1985 | ||||
| 135 | B1 | Hydrotherm | KN4 | KN-08-2115 | Nat. Gas | 25 psi | 30 psi | Varible | 210 | 399,000 | Unable to find NB# | 2009 | |||||
| 135 | B2 | Hydrotherm | KN4 | KN-08-2119 | Nat. Gas | 25 psi | 30 psi | Varible | 210 | 399,000 | Unable to find NB# | 2009 | |||||
| 140 | B1 | Weil McClain | EGH-125 | CP4770518 | Nat. Gas | 25 psi | 50 psi | 180 | 200 | 550,000 | Unable to find NB# | Natural Draft | 2006 | RV-3/4" 950,000 BTUH | |||
| 140 | B2 | Weil McClain | EGH-125 | CP2631399 | Nat. Gas | 25 psi | 50 psi | 180 | 200 | 550,000 | Unable to find NB# | Natural Draft | 1994 | RV-3/4" 950,000 BTUH | |||
| 140 | N | Burnham | P209A-WNI | 17274395 | Nat. Gas | 20 psi | 30 psi | 180 | 205 | 266,000 | Unable to find NB# | Natural Draft | 1992 | ||||
| 142 | Fulton | PW-1000 | BG983018 | Nat. Gas | 20 psi | 160 psi | Variable | 205 | 1,000,000 | 97390 | 2006 | RV-3/4" 3,879,000 BTUH | |||||
| 145 | Raypac | H10724 | 405222398 | Nat. Gas | 35 psi | 125 psi | 180 | 200 | 726,000 | 222398 | Natural Draft | 2008 | |||||
| 155 | Lochinvar | KBN400 | 1644103757098 | Nat. Gas | 15 psi | 50 psi | Variable | 210 | 399,000 | 369155 | 2016 | RV-3/4" 697,000 BTUH | |||||
| 165 | B1 | Lochinvar | FTX500N | 1902113160513 | Nat. Gas | 45 psi | 50 psi | Variable | 210 | 500,000 | 95319 | 2019 | RV-3/4" 697,000 BTUH | ||||
| 165 | B2 | Lochinvar | FTX500N | 1839111967719 | Nat. Gas | 45 psi | 50 psi | Variable | 210 | 500,000 | 326878 | 2019 | RV-3/4" 697,000 BTUH | ||||
| 170 | Weil McClain | M-48-WIR8-G-05 | G242-6243 | Nat. Gas | 18 psi | 30 psi | 175 | 210 | Gorden Piatt | R8-G-05 | 1,010,000 | Unable to find NB# | 1988 | ||||
| 180 | Thermal Solutions | EVA0750BN1-UCCM | 64700010 | Nat. Gas | 40 psi | 150 psi | Varible | 250 | 750,000 | AR-635382 | 2006 | obsolete - don't include | |||||
| 250 | Lochinvar | FTX725N | 1943116748503 | Nat. Gas | 2019 | ||||||||||||
| 255 | B1 | Parker | T-760 | 43452 | Nat. Gas | 15 psi | 30 psi | 160 | 200 | 760,000 | 43452 | Natural Draft | 1993 | ||||
| 255 | B2 | Parker | T-760 | 43453 | Nat. Gas | 15 psi | 30 psi | 160 | 200 | 760,000 | 43453 | Natural Draft | 1993 | ||||
| 265 | Weil McClain | H1676W | CP887441 | Nat. Gas | 25 psi | 30 psi | 150-170 | 200 | Gorden Piatt | R6.1-G0-03 | 504,000 | Unable to find NB# | 1990 | ||||
| 270 | Rite | 48WG | 9022039 | Nat. Gas | 25 psi | 30 psi | 150-200 | No Lockout | Power Flame | J15A-10 | 714,000 | 7813 | 1990 | ||||
| 275 | Weil McClain | 488 | CP2666014 | Nat. Gas | 20 psi | 30 psi | 165 | 210 | Gorden Piatt | R8-G-05 | 1,101,000 | Unable to find NB# | 1991 | ||||
| 304 | N | Raypac | H10624 | 4052222399 | Nat. Gas | 35 psi | 125 psi | 190 | 225 | 627,000 | 222399 | Natural Draft | 2009 | ||||
| 304 | S | Raypac | H10624 | 4052222421 | Nat. Gas | 35 psi | 60 psi | 190 | 225 | 627,000 | Tag Melted | Natural Draft | 2009 | ||||
| 310 | Weil McClain | EGH-85-P1 | CP1481754 | Nat. Gas | 23 psi | 30 psi | 160 | 185 | 350,000 | Unable to find NB# | Natural Draft | 1987 | |||||
| 360 | Weil McClain | H688WS | CP1196096 | Nat. Gas | 23 psi | 30 psi | 150-170 | 210 | Gorden Piatt | R8.2-C0-07 | 1,703,000 | Unable to find NB# | 1986 | ||||
| 365 | Weil McClain | H688WS | CP1159944 | Nat. Gas | 23 psi | 30 psi | 150-170 | 210 | Gorden Piatt | R8.2-C0-07 | 1,703,000 | Unable to find NB# | 1986 | ||||
| 400 | Lochinvar | FBN1251 | 1721106248374 | Nat. Gas | 28 psi | 50 psi | Varible | 210 | 1,250,000 | 240659 | 2018 | ||||||
| 455 | B1 | Newtherm Laars | NTH600NJX2 | 1G12215715 | Nat. Gas | 50 psi | 75 psi | Varible | 210 | 600,000 | 215715 | 2012 | |||||
| 455 | B2 | Newtherm Laars | NTH600NJX2 | 1G12215670 | Nat. Gas | 50 psi | 75 psi | Varible | 210 | 600,000 | 215670 | 2012 | |||||
| 485 | Teledyne Laars | HH0400CN12KBACX | A98CL0132 | Nat. Gas | 50 psi | 75 psi | 140 | 210 | 400,000 | 162483 | Natural Draft | 1998 | |||||
| 491 | Peerless | SC-07-WP | 325322-200009 | Nat. Gas | 23 psi | 50 psi | 180 | 210 | Gorden Piatt | S4.2-G-03 | 577,000 | Unable to find NB# | 2001 | RV-3/4" 950,000 BTUH | |||
| BIDDERS: PLEASE INSERT YOUR UNIT PRICE IN THE LAST COLUMN |
AND RETURN BOTH SHEETS WITH YOUR PRICING PROPOSAL