LINE ITEM DC RADIATION QA DEVICE.xlsx

XLSX spreadsheet 11 KB Posted

Attached to
6525--DC Quantum Electrodynamics and in-vivo dosimetry device rfq
Solicitation number
36C24526Q0619
Issued by

About this file

This is a line item detail spreadsheet for a radiation quality assurance device procurement at the Washington DC VA Medical Center. The spreadsheet identifies six distinct line items required for the solicitation, totaling one unit each. The items include: (1) a wireless RF IVD system with four expandable channels and control module featuring PC software with Microsoft SQL patient database, automatic correction factors, Record and Verify interface, and security features including patient data encryption and audit controls; (2) a QED semiconductor diode device measuring particles and radiation in electron radiation therapy with a 3-meter cable; (3) a clinical diode detector for in-vivo dosimetry detecting real-time dose tracking for photon energy beams ranging from 6 to 12 MV with a 3-meter cable; (4) a flat silicon diode detector for in-vivo dosimetry and quality assurance in high-energy photon treatments measuring 15-25 MV with a 3-meter cable; (5) a specialized cylindrical semiconductor diode detector calibrated for intermediate megavoltage photon beams spanning 6 to 12 MV with a 3-meter cable; and (6) a MultiMet Winston-Lutz device for single-isocenter multiple-met SRS treatments with off-axis QA targeting capability up to 7 centimeters off-axis within 0.1 millimeter accuracy and support for spherical targets of 5 millimeters in diameter.

The related RFQ (36C24526Q0619) specifies submission requirements including completed SF1449 forms, company information with CAGE and UEI codes, contract administration data, price/cost schedule, and delivery schedule information via the provided Excel worksheet. The solicitation closes on Wednesday, July 22, 2026, at 12:00 PM EST with late submissions not accepted. All quotes must be submitted FOB Destination; quotes submitted FOB Origin or FOB Destination Prepaid and Ship will be deemed noncompliant and result in vendor disqualification. This is a single-award solicitation for an unrestricted purchase under NAICS 334519 and PSC code 6525, with the government reserving the right to conduct one-on-one discussions with quoters and to award all or none of the items.

View the file

Other files

File Type Posted
36C24526Q0619_1.docx DOCX document
36C24526Q0619 RFQ.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

ITEM NUMBERQTYVA SON DESCRIPTIONVENDOR PART NAME/DESCRIPTIONPART NUMBERMANUFACTURER NAMEPLACE OF MANUFACTUREPRICETOTAL
00011Wireless option RF IVD includes four channels, expandable to 52 channels, and standard control module with PC software VA TRM Software includes Microsoft SQL patient database, automatic correction factors, Record and Verify interface, as well as patient data encryption, login monitoring, event tracking, and audit control.
00021measure particles and radiation in Quantum Electrodynamics device medical QED semiconductor diodes used in electron radiation therapy. (3m Cable/Negative)
00031a clinical diode detector for in-vivo dosimetry in radiation therapy. Detects real time dose tracking photon energy beams ranging from 6 to 12 MV with a (3m CableNegative)
00041a flat silicon diode detector for in vivo dosimetry and radiation therapy quality assurance high-energy photon treatments measures 15-25MV exact radiation dose delivered to patients with a (3m Cable/Negative).
000516-12 MV specialized cylindrical semiconductor diode Detector Calibrated specifically for intermediate megavoltage photon beams spanning 6 MV to 12 MV with a (3m Cable/Negative)
00061MultiMet- Winston-Lutz device single-isocenter multiple-met SRS treatments, more stringent off-axis QA targets up to 7 cm off-axis within 0.1 mm accuracy to - reduced phantom placement errors spherical targets (5 mm in diameter) set at precise locations .

File details come from the government source that posted it. Updated .