LH_VOLUME 04_Revised_RTA_2023-03-01.pdf
PDF 18 MB Posted
- Attached to
- LINCOLN HALL RENOVATION, BLDG. 607 Federal contract opportunity
- Solicitation number
- W912DS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912DS23R0009.pdf | ||
| Vol 3 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf | ||
| LH_VOLUME 01_Revised_RTA_2023-03-01.pdf | ||
| LH_VOLUME 02_Revised_RTA_2023-03-01.pdf | ||
| JA 009-23 Avaya Switch.pdf | ||
| JA 011-23 Ventrol AHU.pdf | ||
| JA 012-23 Identiv Card Access System.pdf | ||
| JA 013-23 Monaco.pdf | ||
| JA 014-23 Shark Meter.pdf | ||
| JA 006-23 Belden Brick.pdf | ||
| Vol 1 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf | ||
| Vol 2 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf | ||
| LH_VOLUME 03_Revised_RTA_2023-03-01.pdf | ||
| JA 007-23 Distributed Antenna System.pdf | ||
| JA 010-23 Best Hardware Lock Cylinders and Cores.pdf | ||
| JA 008-23-Ruabon Quarry Tile.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
D
C
B
A
US Army Corps of Engineers ®
USMA BUILDING 607 LINCOLN HALL RENOVATION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
CIVIL LANDSCAPE STRUCTURAL ARCHITECTURE INTERIORS
FIRE PROTECTION
LIFE SAFTEY
PLUMBING
MECHANICAL
ELECTRICAL
TELECOM
SECURITY
HAZMAT
NO SEAL
SHEETS ARE FOR
BIDDING AND
INFORMATION
ONLY
D3296400
REVISED RTA SUBMISSION
03/01/2023
ISSUE DATE: 01 MARCH 2023
WEST POINT, NY
CONTRACT NUMBER : W912DS-19-C-0031-L
SOLICITATION NUMBER : W912DS-19-R-0014
G-041
C O
V E
R S
H E
E T
V
O L U
M E
F O
U R
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
VOLUME FOUR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
G-042
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
O N
E A
N D
T W
O
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
NUMBER DRAWING NAME
LIFE SAFETY
LS001 LIFE SAFETY CODE SUMMARY
LS101 LEVEL B3 FLOOR PLAN - LIFE SAFETY
LS102 LEVEL B2 FLOOR PLAN - LIFE SAFETY
LS103 LEVEL B1 FLOOR PLAN - LIFE SAFETY
LS104 LEVEL 1 FLOOR PLAN - LIFE SAFETY
LS105 LEVEL 2 FLOOR PLAN - LIFE SAFETY
LS106 LEVEL 3 FLOOR PLAN - LIFE SAFETY
LS107 LEVEL 4 FLOOR PLAN - LIFE SAFETY
HAZARDOUS
H-101 LEVEL B3 HAZMAT PLAN
H-102 LEVEL B2 HAZMAT PLAN
H-103 LEVEL B1 HAZMAT PLAN
H-104 LEVEL 1 HAZMAT PLAN
H-105 LEVEL 2 HAZMAT PLAN
H-106 LEVEL 3 HAZMAT PLAN
H-107 LEVEL 4 HAZMAT PLAN
CIVIL
C-001 GENERAL NOTES
C-002 GENERAL NOTES, LEGEND, AND ABBREVIATIONS
BB501 SOIL BORING LOG
C-101 EXISTING CONDITIONS PLAN
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CS102 TRUCK ACCESS PLAN
CS103 CONSTRUCTION LOGISTICS PLAN
CG101 GRADING AND DRAINAGE PLAN
CG102 SOIL EROSION PLAN
CU101 UTILITY PLAN
C-201 DRAINAGE PROFILE
C-501 CONSTRUCTION DETAILS
C-502 CONSTRUCTION DETAILS
C-503 CONSTRUCTION DETAILS
C-504 CONSTRUCTION DETAILS
C-505 CONSTRUCTION DETAILS
C-506 CONSTRUCTION DETAILS
LANDSCAPE
L-101 LANDSCAPE PLAN
L-501 LANDSCAPE DETAILS
L-502 LANDSCAPE DETAILS
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES
S-002 STRUCTURAL ABBREVIATIONS, SYMBOLS, LEGEND
S-010 LOAD PLANS
S-011 SNOW AND WIND LOADING PLANS
SD101 LEVEL B3 DEMOLITION PLAN
SD102 LEVEL B2 DEMOLITION PLAN
SD103 LEVEL B1 DEMOLITION PLAN
SD104 LEVEL 1 DEMOLITION PLAN
SD105 LEVEL 2 DEMOLITION PLAN
SD106 LEVEL 3 DEMOLITION PLAN
SD107 LEVEL 4/ROOF DEMOLITION PLAN - SOUTH WING
SD108 ROOF DEMOLITION PLAN - NORTH WING AND TOWER
SD401 LARGE SCALE VIEWS
SD402 LARGE SCALE VIEWS
S-101 LEVEL B3 FLOOR PLAN
S-102 LEVEL B2 FLOOR PLAN
S-103 LEVEL B1 FLOOR PLAN
S-104 LEVEL1 FLOOR PLAN
S-105 LEVEL2 FLOOR PLAN
S-106 LEVEL3 FLOOR PLAN
S-107 LEVEL 4/ROOF PLAN - SOUTH WING
S-108 ROOF PLAN - NORTH WING AND TOWER
S-201 ELEVATIONS
S-401 LARGE SCALE VIEWS
S-402 LARGE SCALE VIEWS
S-403 LARGE SCALE VIEWS
S-404 LARGE SCALE VIEWS
S-501 TYPICAL DETAILS - FOUNDATIONS, WALLS, SLABS-ON-GRADE, SLABS
S-502 TYPICAL DETAILS - DEVELOPMENT LENGTHS, POST-INSTALLED ANCHORS, STEEL BEAMS
S-503 TYPICAL DETAILS - STEEL BEAMS AND LINTELS
S-504 TYPICAL DETAILS - STEEL BEAMS AND LINTELS
S-505 TYPICAL DETAILS - STEEL DETAILS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
INDEX OF DRAWINGS - VOLUME ONE INDEX OF DRAWINGS - VOLUME TWO
NUMBER DRAWING NAME
A-511 EXTERIOR DETAILS
A-512 EXTERIOR DETAILS
A-513 EXTERIOR DETAILS
A-514 EXTERIOR DETAILS
A-521 WINDOW DETAILS
A-522 WINDOW DETAILS
A-523 WINDOW DETAILS
A-531 ROOF DETAILS
A-532 ROOF DETAILS
A-533 STAIR TOWER ATTIC ACCESS DETAILS
A-541 EXTERIOR GUARDRAIL AND HANDRAIL DETAILS
A-542 RETAIL STORE STAIR DETAILS
A-543 RETAIL STORE STAIR DETAILS
A-545 INTERIOR STAIR DETAILS
A-546 INTERIOR STAIR DETAILS
A-551 CEILING DETAILS
A-552 TV STUDIO CEILING AND PARTITION DETAILS
A-553 TV STUDIO CEILING DETAILS
A-554 TV STUDIO CEILING DETAILS
A-561 MILLWORK DETAILS - CAFE
A-562 MILLWORK DETAILS - BRIEFING ROOM
A-563 MILLWORK DETAILS - TYPICAL
A-564 MILLWORK DETAILS - TYPICAL
A-601 PARTITION TYPES
A-602 PARTITION TYPES
A-604 DOOR SCHEDULE AND DETAILS
A-605 DOOR SCHEDULE AND DETAILS
A-606 GLAZED PARTITION AND DOOR DETAILS
A-607 DOOR DETAILS
A-608 DOOR DETAILS
A-609 EXTERIOR DOOR DETAILS
A-610 EXTERIOR DOOR DETAILS
A-615 WINDOW TYPES AND SCHEDULE
A-620 INTERIOR ALUMINUM FRAME SYSTEM
A-621 INTERIOR ALUMINUM FRAME SYSTEM
A-901 EXTERIOR RESTORATION ELEVATIONS
A-902 EXTERIOR RESTORATION ELEVATIONS
A-903 EXTERIOR RESTORATION ELEVATIONS
A-904 EXTERIOR RESTORATION ELEVATIONS
A-905 EXTERIOR RESTORATION ELEVATIONS
A-906 EXTERIOR RESTORATION ELEVATIONS
A-907 EXTERIOR RESTORATION ELEVATIONS
ARCHITECTURAL SIGNAGE
AG001 SITE SIGNAGE PLAN
AG101 LEVEL B3 FLOOR PLAN -SIGNAGE
AG102 LEVEL B2 FLOOR PLAN - SIGNAGE
AG103 LEVEL B1 FLOOR PLAN - SIGNAGE
AG104 LEVEL 1 FLOOR PLAN - SIGNAGE
AG105 LEVEL 2 FLOOR PLAN - SIGNAGE
AG106 LEVEL 3 FLOOR PLAN - SIGNAGE
AG107 LEVEL 4 FLOOR PLAN - SIGNAGE
AG201 SIGNAGE - EXTERIOR SIGN ELEVATIONS
AG202 SIGNAGE - INTERIOR SIGN ELEVATIONS
AG203 SIGNAGE - INTERIOR SIGN ELEVATIONS
AG501 SIGNAGE LAYOUTS
AG502 SIGNAGE LAYOUTS
AG601 SIGNAGE SCHEDULE
INTERIOR
I-101 LEVEL B3 FLOOR PLAN - FINISH
I-102 LEVEL B2 FLOOR PLAN - FINISH
I-103 LEVEL B1 FLOOR PLAN - FINISH
I-104 LEVEL 1 FLOOR PLAN - FINISH
I-105 LEVEL 2 FLOOR PLAN - FINISH
I-106 LEVEL 3 FLOOR PLAN - FINISH
I-107 LEVEL 4 FLOOR PLAN - FINISH
I-111 LEVEL B3 FLOOR PLAN - FURNITURE
I-112 LEVEL B2 FLOOR PLAN - FURNITURE
I-113 LEVEL B1 FLOOR PLAN - FURNITURE
I-114 LEVEL 1 FLOOR PLAN - FURNITURE
I-115 LEVEL 2 FLOOR PLAN - FURNITURE
I-116 LEVEL 3 FLOOR PLAN - FURNITURE
I-117 LEVEL 4 FLOOR PLAN - FURNITURE
I-400 ENLARGED FINISH FLOOR PLANS - CORRIDORS
I-401 ENLARGED FINISH FLOOR PLANS - CORRIDORS, CAFE, RESTROOMS
I-402 ENLARGED FINISH FLOOR PLANS - RETAIL STORE, CORRIDOR
I-403 ENLARGED FINISH FLOOR PLANS - CORRIDORS
I-404 ENLARGED FINISH FLOOR PLANS - CENTRAL STAIR
I-405 ENLARGED FINISH FLOOR PLANS - CENTRAL STAIR, BREAK ROOMS
I-406 ENLARGED FINISH FLOOR PLANS - PHOTO STUDIO
I-500 INTERIOR DETAILS
I-501 INTERIOR DETAILS
I-600 COLOR MATERIAL LEGEND
I-601 COLOR MATERIAL LEGEND
I-602 FINISH MATERIAL SCHEDULE
I-603 FINISH MATERIAL SCHEDULE
I-604 FINISH MATERIAL SCHEDULE
NUMBER DRAWING NAME
ARCHITECTURAL
A-001 ABBREVIATIONS, MOUNTING HEIGHTS, AND SYMBOLS
AD101 LEVEL B3 DEMOLITION PLAN
AD102 LEVEL B2 DEMOLITION PLAN
AD103 LEVEL B1 DEMOLITION PLAN
AD104 LEVEL 1 DEMOLITION PLAN
AD105 LEVEL 2 DEMOLITION PLAN
AD106 LEVEL 3 DEMOLITION PLAN
AD107 LEVEL 4 DEMOLITION PLAN
AD108 ROOF DEMOLITION PLAN
A-101 LEVEL B3 FLOOR PLAN
A-102 LEVEL B2 FLOOR PLAN
A-103 LEVEL B1 FLOOR PLAN
A-104 LEVEL 1 FLOOR PLAN
A-105 LEVEL 2 FLOOR PLAN
A-106 LEVEL 3 FLOOR PLAN
A-107 LEVEL 4 FLOOR PLAN
A-108 ROOF PLAN
A-111 LEVEL B3 REFLECTED CEILING PLAN
A-112 LEVEL B2 REFLECTED CEILING PLAN
A-113 LEVEL B1 REFLECTED CEILING PLAN
A-114 LEVEL 1 REFLECTED CEILING PLAN
A-115 LEVEL 2 REFLECTED CEILING PLAN
A-116 LEVEL 3 REFLECTED CEILING PLAN
A-117 LEVEL 4 REFLECTED CEILING PLAN
A-201 SOUTH WING ELEVATIONS
A-202 SOUTH WING ELEVATIONS
A-203 NORTH WING AND TOWER ELEVATIONS
A-204 NORTH WING AND TOWER ELEVATIONS
A-205 ENLARGED ELEVATIONS - PENTHOUSE AND SALLY PORT
A-206 ENLARGED EXTERIOR ELEVATIONS, RETAINING WALLS
A-211 EXTERIOR WALL TYPICAL CONDITION PHOTOS
A-212 EXTERIOR WALL TYPICAL CONDITIONS PHOTOS
A-301 SOUTH WING BUILDING SECTION
A-302 SOUTH AND NORTH WING BUILDING SECTIONS
A-303 NORTH WING BUILDING SECTIONS
A-311 PARTIAL BUILDING SECTIONS
A-321 EXTERIOR WALL/ROOF SECTIONS PENTHOUSE
A-322 SHAFT SECTIONS
A-401 ENLARGED RESTROOM FLOOR PLANS
A-402 LEVEL B2 - ENLARGED CENTRAL STAIR FLOOR PLANS
A-403 LEVEL 1 AND 2 - ENLARGED CENTRAL STAIR FLOOR PLANS
A-404 LEVEL 3 AND 4 - ENLARGED CENTRAL STAIR FLOOR PLANS
A-405 ENLARGED CENTRAL STAIR RCPS
A-406 INTERIOR STAIRS ENLARGED PLANS & SECTIONS
A-407 ELEVATOR FLOOR PLANS, SECTIONS AND ELEVATIONS
A-411 CENTRAL STAIR TOWER SECTIONS/ELEVATIONS
A-412 CENTRAL STAIR LOBBY ELEVATIONS
A-413 CENTRAL STAIR LOBBY ELEVATIONS
A-414 CENTRAL STAIR LOBBY ELEVATIONS
A-415 CENTRAL STAIR LOBBY ELEVATIONS
A-421 CAFE ENLARGED PLANS AND ELEVATIONS
A-423 RETAIL STORE ENLARGED PLANS
A-424 RETAIL STORE ENLARGED PLANS
A-425 RETAIL STORE ELEVATIONS
A-426 RETAIL STORE ELEVATIONS AND DETAILS
A-427 RETAIL STORE DISPLAY WINDOW ELEVATIONS
A-428 RETAIL STORE PERSPECTIVE VIEWS AND DETAILS
A-429 ENLARGED BRIEFING ROOM PLANS AND ELEVATIONS
A-430 ENLARGED TV STUDIO PLANS
A-431 ENLARGED TV STUDIO SECTIONS/ELEVATIONS
A-432 INTERIOR ELEVATIONS - TV STUDIO
A-433 ENLARGED BREAK ROOM PLANS AND ELEVATIONS
A-434 ENLARGED CONFERENCE ROOM PLANS AND ELEVATIONS
A-435 ENLARGED CONFERENCE ROOM PLANS AND ELEVATIONS
A-436 OPEN OFFICE ENLARGED EXTERIOR WALL ELEVATIONS
A-437 OPEN OFFICE ENLARGED EXTERIOR WALL ELEVATIONS
A-439 ENLARGED PHOTO STUDIO PLANS AND ELEVATIONS
A-440 ENLARGED CHANGING ROOM PLANS AND ELEVATIONS
NUMBER DRAWING NAME
GENERAL
G-011 COVER SHEET - VOLUME ONE
G-012 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-013 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
NUMBER DRAWING NAME
GENERAL
G-021 COVER SHEET - VOLUME TWO
G-022 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-023 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
G-043
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
T H
R E
E A
N D
F O
U R
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
NUMBER DRAWING NAME
MECHANICAL
M-001 HVAC LEGEND
M-002 HVAC LEGEND
MD101 LEVEL B3 DEMOLITION PLAN - HVAC
MD102 LEVEL B2 DEMOLITION PLAN - HVAC
MD103 LEVEL B1 DEMOLITION PLAN - HVAC
MD104 LEVEL 1 DEMOLITION PLAN - HVAC
MD105 LEVEL 2 DEMOLITION PLAN - HVAC
MD106 LEVEL 3 DEMOLITION PLAN - HVAC
MD107 LEVEL 4 DEMOLITION PLAN - HVAC
MD108 ROOF DEMOLITION PLAN - HVAC
MH101 LEVEL B3 FLOOR PLAN - DUCTWORK
MH102 LEVEL B2 FLOOR PLAN - DUCTWORK
MH103 LEVEL B1 FLOOR PLAN - DUCTWORK
MH104 LEVEL 1 FLOOR PLAN - DUCTWORK
MH105 LEVEL 2 FLOOR PLAN - DUCTWORK
MH106 LEVEL 3 FLOOR PLAN - DUCTWORK
MH107 LEVEL 4 FLOOR PLAN - DUCTWORK
MH108 ROOF PLAN - DUCTWORK
MP101 LEVEL B3 FLOOR PLAN - PIPING
MP102 LEVEL B2 FLOOR PLAN - PIPING
MP103 LEVEL B1 FLOOR PLAN - PIPING
MP104 LEVEL 1 FLOOR PLAN - PIPING
MP105 LEVEL 2 FLOOR PLAN - PIPING
MP106 LEVEL 3 FLOOR PLAN - PIPING
MP107 LEVEL 4 FLOOR PLAN - PIPING
MP108 ROOF PLAN - PIPING
M-301 MECHANICAL SECTIONS - HVAC SHAFTS
M-302 MECHANICAL SECTIONS
M-303 MECHANICAL SECTIONS
M-401 HVAC ENLARGED PLANS
M-402 HVAC ENLARGED PLANS
M-501 HVAC DETAILS
M-502 HVAC DETAILS
M-503 HVAC DETAILS
M-504 HVAC DETAILS
M-505 HVAC DETAILS
M-506 HVAC DETAILS
M-507 HVAC DETAILS
M-601 HVAC SCHEDULES
M-602 HVAC SCHEDULES
M-603 HVAC SCHEDULES
M-604 HVAC SCHEDULES
M-605 HVAC SCHEDULES
M-701 STEAM AND HOT WATER FLOW DIAGRAM
M-702 CHILLED WATER FLOW DIAGRAMS - CAMPUS CHW AND CHILLED BEAM LOOP
M-703 HYDRONIC FLOW DIAGRAM - LEVEL B2 AND B3
M-704 HYDRONIC FLOW DIAGRAM - LEVEL B1
M-705 HYDRONIC FLOW DIAGRAM - LEVEL 1
M-706 HYDRONIC FLOW DIAGRAM - LEVEL 2
M-707 HYDRONIC FLOW DIAGRAM - LEVEL 3
M-708 HYDRONIC FLOW DIAGRAM - LEVEL 4 AND ROOF
M-709 AIRFLOW RISER DIAGRAM - DOAS-1
M-710 AIRFLOW RISER DIAGRAM - DOAS-2
M-711 AIRFLOW RISER DIAGRAM - MAU-1
M-801 CONTROL SCHEMATIC SYMBOLS, ABBREVIATIONS AND ACRONYMS
M-802 HVAC CONTROL DIAGRAM
M-803 HVAC CONTROL DIAGRAM
M-804 HVAC CONTROL DIAGRAM
M-805 HVAC CONTROL DIAGRAM
M-806 HVAC CONTROL DIAGRAM
M-807 HVAC CONTROL DIAGRAM
M-808 HVAC CONTROL DIAGRAM
M-809 HVAC CONTROL DIAGRAM
M-810 HVAC CONTROL DIAGRAM
M-811 HVAC CONTROL DIAGRAM
M-812 HVAC CONTROL DIAGRAM
M-813 HVAC CONTROL DIAGRAM
M-814 HVAC CONTROL DIAGRAM
M-815 HVAC CONTROL DIAGRAM
M-816 HVAC CONTROL DIAGRAM
M-817 HVAC CONTROL DIAGRAM
M-818 HVAC CONTROL DIAGRAM
M-819 HVAC CONTROL DIAGRAM
M-820 HVAC CONTROL DIAGRAM
M-821 HVAC CONTROL DIAGRAM
M-822 HVAC CONTROL DIAGRAM
M-823 HVAC CONTROL DIAGRAM
M-824 HVAC CONTROL POINTS SCHEDULE
M-825 HVAC CONTROL POINTS SCHEDULE
M-826 HVAC CONTROL POINTS SCHEDULE
M-827 HVAC CONTROL POINTS SCHEDULE
M-828 HVAC CONTROL POINTS SCHEDULE
M-829 HVAC CONTROL POINTS SCHEDULE
M-830 HVAC CONTROL POINTS SCHEDULE
M-831 HVAC CONTROL POINTS SCHEDULE
M-832 HVAC CONTROL POINTS SCHEDULE
M-833 HVAC CONTROL POINTS SCHEDULE
M-834 HVAC CONTROL POINTS SCHEDULE
M-835 HVAC CONTROL POINTS SCHEDULE
M-836 HVAC CONTROL POINTS SCHEDULE
M-837 HVAC CONTROL POINTS SCHEDULE
M-838 HVAC CONTROL POINTS SCHEDULE
M-839 HVAC CONTROL POINTS SCHEDULE
M-840 HVAC CONTROL POINTS SCHEDULE
M-841 HVAC CONTROL POINTS SCHEDULE
M-842 HVAC CONTROL POINTS SCHEDULE
M-843 HVAC CONTROL POINTS SCHEDULE
M-844 HVAC CONTROL POINTS SCHEDULE
M-845 UMCS SCHEDULES
M-846 THERMOSTAT SCHEDULE
M-847 THERMOSTAT SCHEDULE
M-848 VALVE & DAMPER SCHEDULES
NUMBER DRAWING NAME
FIRE ALARM
FA001 FIRE ALARM - SYMBOLS, ABBREVIATIONS, GENERAL NOTES, AND MASS NOTIFICATION
FD101 LEVEL B3 DEMOLITION PLAN - FIRE ALARM
FD102 LEVEL B2 DEMOLITION PLAN - FIRE ALARM
FD103 LEVEL B1 DEMOLITION PLAN - FIRE ALARM
FD104 LEVEL 1 DEMOLITION PLAN - FIRE ALARM
FD105 LEVEL 2 DEMOLITION PLAN - FIRE ALARM
FD106 LEVEL 3 DEMOLITION PLAN - FIRE ALARM
FD107 LEVEL 4 DEMOLITION PLAN - FIRE ALARM
FA101 LEVEL B3 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA102 LEVEL B2 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA103 LEVEL B1 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA104 LEVEL 1 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA105 LEVEL 2 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA106 LEVEL 3 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA107 LEVEL 4 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA108 ROOF PLAN - FIRE ALARM PLAN AND MASS NOTIFICATION
FA701 FIRE ALARM AND MASS NOTIFICATION DETAILS
FA702 FIRE ALARM AND MASS NOTIFICATION DETAILS
FA703 FIRE ALARM AND MASS NOTIFICATION DETAILS
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION - SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
FD111 LEVEL B3 DEMOLITION PLAN - FIRE SUPPRESSION
FD112 LEVEL B2 DEMOLITION PLAN - FIRE SUPPRESSION
FD113 LEVEL B1 DEMOLITION PLAN - FIRE SUPPRESSION
FD114 LEVEL 1 DEMOLITION PLAN - FIRE SUPPRESSION
FD115 LEVEL 2 DEMOLITION PLAN - FIRE SUPPRESSION
FD116 LEVEL 3 DEMOLITION PLAN - FIRE SUPPRESSION
FD117 LEVEL 4 DEMOLITION PLAN - FIRE SUPRESSION
FX101 LEVEL B3 FLOOR PLAN - FIRE SUPPRESSION
FX102 LEVEL B2 FLOOR PLAN - FIRE SUPPRESSION
FX103 LEVEL B1 FLOOR PLAN - FIRE SUPPRESSION
FX104 LEVEL 1 FLOOR PLAN - FIRE SUPPRESSION
FX105 LEVEL 2 FLOOR PLAN - FIRE SUPPRESSION
FX106 LEVEL 3 FLOOR PLAN - FIRE SUPPRESSION
FX107 LEVEL 4 FLOOR PLAN - FIRE SUPPRESSION
FX108 ROOF PLAN - FIRE SUPPRESSION PLAN
FX501 FIRE SUPPRESSION DETAILS
FX502 FIRE SUPPRESSION DETAILS
PLUMBING
P-001 PLUMBING ABBREVIATIONS, SYMBOLS AND GENERAL NOTES
PD101 LEVEL B3 DEMOLITION PLAN - PLUMBING
PD102 LEVEL B2 DEMOLITION PLAN - PLUMBING
PD103 LEVEL B1 DEMOLITION PLAN - PLUMBING
PD104 LEVEL 1 DEMOLITION PLAN - PLUMBING
PD105 LEVEL 2 DEMOLITION PLAN - PLUMBING
PD106 LEVEL 3 DEMOLITION PLAN - PLUMBING
PD107 LEVEL 4 DEMOLITION PLAN - PLUMBING
PD108 ROOF DEMOLITION PLAN - PLUMBING
P-101 LEVEL B3 FLOOR PLAN - PLUMBING
P-102 LEVEL B2 FLOOR PLAN - PLUMBING
P-103 LEVEL B1 FLOOR PLAN - PLUMBING
P-104 LEVEL 1 FLOOR PLAN - PLUMBING
P-105 LEVEL 2 FLOOR PLAN - PLUMBING
P-106 LEVEL 3 FLOOR PLAN - PLUMBING
P-107 LEVEL 4 FLOOR PLAN - PLUMBING
P-108 ROOF PLAN - PLUMBING
P-401 TOILET ENLARGED PLANS
P-402 TOILET ENLARGED PLANS
P-403 ENLARGED PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-503 PLUMBING DETAILS
P-604 SCHEDULES
P-701 DOMESTIC WATER RISER DIAGRAMS
P-702 SANITARY AND VENT RISER DIAGRAMS
P-703 STORM WATER RISER DIAGRAMS
INDEX OF DRAWINGS - VOLUME THREE INDEX OF DRAWINGS - VOLUME FOUR
NUMBER DRAWING NAME
TELECOMMUNICATIONS
T-001 SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
TD101 LEVEL B3 COMMUNICATION DEMOLITION PLAN
TD102 LEVEL B2 COMMUNICATIONS DEMOLITION PLAN
TD103 LEVEL B1 COMMUNICATIONS DEMOLITION PLAN
TD104 LEVEL 1 - COMMUNICATIONS DEMOLITION PLAN
TD105 LEVEL 2 - COMMUNICATIONS DEMOLITION PLAN
TD106 LEVEL 3 - COMMUNICATIONS DEMOLITION PLAN
TD107 LEVEL 4 - COMMUNICATIONS DEMOLITION PLAN
TS101 PARTIAL TELECOM SITE PLAN
TS102 PARTIAL TELECOM SITE PLAN
T-101 LEVEL B3 FLOOR PLAN - COMMUNICATIONS
T-102 LEVEL B2 FLOOR PLAN - COMMUNICATIONS
T-103 LEVEL B1 FLOOR PLAN - COMMUNICATIONS
T-104 LEVEL 1 FLOOR PLAN - COMMUNICATIONS
T-105 LEVEL 2 FLOOR PLAN - COMMUNICATIONS
T-106 LEVEL 3 FLOOR PLAN - COMMUNICATIONS
T-107 LEVEL 4 FLOOR PLAN - COMMUNICATIONS
TY101 LEVEL B3 FLOOR PLAN - SECURITY
TY102 LEVEL B2 FLOOR PLAN - SECURITY
TY103 LEVEL B1 FLOOR PLAN - SECURITY
TY104 LEVEL 1 FLOOR PLAN - SECURITY
TY105 LEVEL 2 FLOOR PLAN - SECURITY
TY106 LEVEL 3 FLOOR PLAN - SECURITY
TY107 LEVEL 4 FLOOR PLAN - SECURITY
TY501 SECURITY DOOR AND CAMERA DETAILS
TY601 SECURITY PATHWAY DIAGRAM
T-201 RACK ELEVATIONS
T-202 RACK ELEVATIONS
T-203 RACK ELEVATIONS
T-204 RACK ELEVATIONS
T-401 ENLARGED TELECOM ROOM PLANS
T-402 ENLARGED TELECOM ROOM PLANS
T-403 ENLARGED TELECOM ROOM PLANS
T-404 ENLARGED TELECOM ROOM PLANS
T-501 COMMUNICATIONS OUTLET DETAILS
T-502 COMMUNICATIONS DETAILS
T-503 GROUNDING AND BONDING DETAILS
T-504 CABLE TRAY DETAILS
T-600 VOICE AND DATA OSP ONE-LINE DIAGRAM
T-601 NIPR VOICE AND DATA ONE-LINE DIAGRAM
T-602 WREN AND WAP DATA ONE-LINE DIAGRAM
T-603 F-DAS, C-DAS AND CLOCK ONE-LINE DIAGRAM
T-604 TELECOM BONDING AND GROUNDING ONE-LINE DIAGRAM
NUMBER DRAWING NAME
ELECTRICAL
E-001 GENERAL NOTES, AND ABBREVIATIONS
E-002 SYMBOLS
ED100 SITE DEMOLITION PLAN
ED101 LEVEL B3 DEMOLITION PLAN
ED102 LEVEL B2 DEMOLITION PLAN
ED103 LEVEL B1 DEMOLITION PLAN
ED104 LEVEL 1 DEMOLITION PLAN
ED105 LEVEL 2 DEMOLITION PLAN
ED106 LEVEL 3 DEMOLITION PLAN
ED107 LEVEL 4 DEMOLITION PLAN
ED108 ROOF DEMOLITION PLAN
ED601 DEMOLITION - RISER DIAGRAM
EL101 LEVEL B3 LIGHTING PLAN
EL102 LEVEL B2 LIGHTING PLAN
EL103 LEVEL B1 LIGHTING PLAN
EL104 LEVEL 1 LIGHTING PLAN
EL105 LEVEL 2 LIGHTING PLAN
EL106 LEVEL 3 LIGHTING PLAN
EL107 LEVEL 4 LIGHTING PLAN
EL108 ROOF LIGHTING PLAN
EL701 LUMINAIRE SCHEDULE
EL702 LIGHTING CONTROL SCHEDULES
EL703 LIGHTING CONTROL SCHEDULES
ES100 SITE PLAN
EP101 LEVEL B3 POWER PLAN
EP102 LEVEL B2 POWER PLAN
EP103 LEVEL B1 POWER PLAN
EP104 LEVEL 1 POWER PLAN
EP105 LEVEL 2 POWER PLAN
EP106 LEVEL 3 POWER PLAN
EP107 LEVEL 4 POWER PLAN
EP108 ELECTRICAL ROOF POWER PLAN
EP401 ELARGED POWER PLANS
EP402 ENLARGED POWER PLANS
EM101 ELECTRICAL LEVEL B3 EQUIPMENT PLAN
EM102 ELECTRICAL LEVEL B2 EQUIPMENT PLAN
EM103 ELECTRICAL LEVEL B1 EQUIPMENT PLAN
EM104 ELECTRICAL LEVEL 1 EQUIPMENT PLAN
EM105 ELECTRICAL LEVEL 2 EQUIPMENT PLAN
EM106 ELECTRICAL LEVEL 3 EQUIPMENT PLAN
EM107 ELECTRICAL LEVEL 4 EQUIPMENT PLAN
EM108 ELECTRICAL ROOF EQUIPMENT PLAN
EM701 MECHANICAL EQUIPMENT SCHEDULE
EG101 LEVEL B1 GROUNDING PLAN
EG102 ROOF LIGHTNING PROTECTION PLAN
EG601 GROUNDING RISER DIAGRAM
E-501 DETAILS
E-502 DETAILS
E-503 DETAILS
E-504 DETAILS
E-505 DETAILS
E-601 SINGLE LINE DIAGRAM
E-602 POWER RISER DIAGRAM
E-700 ELECTRICAL PANEL SCHEDULE INDEX
E-701 ELECTRICAL PANEL SCHEDULES
E-702 ELECTRICAL PANEL SCHEDULES
E-703 ELECTRICAL PANEL SCHEDULES
E-704 ELECTRICAL PANEL SCHEDULES
E-705 ELECTRICAL PANEL SCHEDULES
E-706 ELECTRICAL PANEL SCHEDULES
E-707 ELECTRICAL PANEL SCHEDULES
E-708 ELECTRICAL PANEL SCHEDULES
E-709 ELECTRICAL PANEL SCHEDULES
E-710 ELECTRICAL PANEL SCHEDULES
E-711 ELECTRICAL PANEL SCHEDULES
E-712 ELECTRICAL PANEL SCHEDULES
E-713 ELECTRICAL PANEL SCHEDULES
E-714 ELECTRICAL PANEL SCHEDULES
NUMBER DRAWING NAME
GENERAL
G-041 COVER SHEET - VOLUME FOUR
G-042 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-043 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
NUMBER DRAWING NAME
GENERAL
G-031 COVER SHEET - VOLUME THREE
G-032 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-033 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
AFF ABOVE FINISHED FLOOR
ANN ANNUNCIATOR
ARCH ARCHITECTURAL
AS AMMETER SWITCH
ASYM ASYMMETRICAL
ATS AUTOMATIC TRANSFER SWITCH
AV AUDIO AND VISUAL
BATT BATTERY
BB BACKBONE
BBV BACKBONE VOICE
BEPB BUILDING ENTRANCE PROTECTION BLOCKS
BKR BREAKER
BLDG BUILDING
C CONDUIT
CAB CABINET
CAT CATEGORY
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
CLP CITY LIGHT AND POWER (THE UTILITY COMPANY)
COMM COMMUNICATIONS
CONST CONSTRUCTION
CONT CONTROL
CPT CONTROL POWER TRANSFORMER
CT COUNTER TOP
DELTA CONNECTED
DB DISTRIBUTION BOARD
DIST DISTRIBUTION
DS DISCONNECT SWITCH
DPW DIRECTORATE OF PUBLIC WORKS
DWG DRAWING
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EGB ELECTRICAL GROUND BUS
EMGB ELECTRICAL MAIN GROUND BUS
EMER EMERGENCY
EQPT EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FDR FEEDER
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FO FIBER OPTIC
FT FOOT
G GROUND
EGB ELECTRICAL GROUND BUS
GFI GROUND FAULT CIRCUIT INTERRUPTER
H HOT (UNSWITCHED)
HTR HEATER
HVAC HEATING, VENTILATION AND AIR CONDITIONING
IDS INTRUSION DETECTION SYSTEM
JB JUNCTION BOX
LC LIGHTING CONTACTOR
LTG LIGHTING
MCB MAIN CIRCUIT BREAKER
MECH MECHANICAL
MFR MANUFACTURER
MH MOUNTING HEIGHT
MLO MAIN LUGS ONLY
MMF MULTI MODE FIBER
MTD MOUNTED
N NEUTRAL
NC NORMALLY CLOSED
NF NON FUSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOAD
PB PULL BOX
PC PERSONAL COMPUTER
PLAS PLASTIC
PNL PANEL
PR PAIR
PWR POWER
QTY QUANTITY
RAF RAISED ACCESS FLOOR
RECP RECEPTACLE
REQD REQUIRED
REX REQUEST TO EXIT
RM ROOM
RSC RIGID STEEL CONDUIT
SCRT SECURITY
SECT SECTION
SN SOLID NEUTRAL
SPD SURGE PROTECTIVE DEVICE
SPEC SPECIFICATION
ST SHUNT TRIP
SURF SURFACE
SW SWITCH
SYM SYMMETRICAL
SYS SYSTEMS
TEL TELEPHONE
TELCOM TELECOMMUNICATIONS
TGB TELECOM GROUND BUS
TMGB TELECOM MAIN GROUND BUS
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
VD VOLTAGE DROP
VFD VARIABLE FREQUENCY DRIVE
VT VOLTAGE TRANSFORMER
XFMR TRANSFORMER
XFR TRANSFER
Y WYE CONNECTED
ELECTRICAL ABBREVIATIONS
ALL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT.
LIGHTING CONTROL ZONE DESIGNATIONS INDICATE WHICH DEVICES CONTROL WHICH GROUPS OF FIXTURES. WHERE LOCAL SWITCHES AND DIMMERS ARE SHOWN, OR WHERE NO CONTROL ZONE DESIGNATION IS INDICATED, LOCAL
CONTROL DEVICES SHALL ONLY CONTROL FIXTURES IN THEIR RESPECTIVE ROOMS OR AREAS.
COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH LOCATION OF EQUIPMENT, PIPING, AND DUCTWORK.
SEE EQUIPMENT CONNECTION SCHEDULE AND SINGLE LINE DIAGRAM FOR WIRE SIZES, CONDUIT SIZES, AND DEVICE
RATINGS NOT SHOWN ON POWER PLANS.
EACH BRANCH CIRCUIT SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR, UNLESS OTHERWISE NOTED.
MOUNTING HEIGHTS FOR CEILING MOUNTED FIXTURES OR DEVICES ARE TO BOTTOM OF FIXTURES OR DEVICES, UNLESS
OTHERWISE NOTED.
MOUNTING HEIGHTS FOR WALL MOUNTED FIXTURES OR DEVICES ARE TO CENTER LINE OF OUTLET BOXES, UNLESS
OTHERWISE NOTED.
FOR MOUNTING HEIGHTS AND EXACT LOCATION OF DEVICES, REFER TO ARCHITECTURAL ELEVATIONS. IF NOT DETAILED ON ARCHITECTURAL ELEVATIONS, THEN USE REQUIREMENTS AS FOLLOWS. MOUNTING HEIGHTS ARE ABOVE FINISHED
FLOOR AND TO CENTERLINE OF DEVICE, UNLESS OTHERWISE NOTED:
WALL AND END MOUNTED EXIT SIGNS
LIGHTING SWITCHES
OCCUPANCY SENSOR SWITCH
WALL MOUNTED OCCUPANCY SENSORS
GENERAL PURPOSE RECEPTACLES
COUNTER TOP RECEPTACLES (CT)
FURNITURE JUNCTION BOXES
MONITOR (M)
LED SINAGE (L)
CLOCK (C)
WALL PHONE RECEPTACLE
96-INCHES
48-INCHES
48-INCHES
96-INCHES
18-INCHES
8-INCHES ABOVE COUNTER
18-INCHES
MOUNT AT CENTERLINE BEHIND EQUIPMENT
MOUNT AT CENTERLINE BEHIND EQUIPMENT
MOUNT AT CENTERLINE BEHIND EQUIPMENT
48-INCHES
ELECTRICAL GENERAL NOTES
UTILIZE TWO PIECE CONDUIT CLAMPS FOR CONDUIT RUNS ON SLAB TO MAINTAIN A MINIMUM 1/4-INCHES GAP BETWEEN
CONDUIT AND CONCRETE.
CRITICAL EQUIPMENT ITEMS THAT ARE INHERENTLY INFLEXIBLE SHALL BE BRACED OR STIFFENED SO THAT THE LOWEST INTERNAL NATURAL FREQUENCY IS GREATER THAN TWO TIMES THE MOUNT SYSTEM NATURAL FREQUENCY.
ALL SUSPENDED ITEMS OF THE WORK EXCEEDING 14 KILOGRAMS IN WEIGHT SHALL BE ANCHORED TO RESIST A HORIZONTAL LOAD EQUAL TO 0.5 TIMES THE COMPONENT WEIGHT APPLIED SIMULTANEOUSLY WITH A VERTICAL DOWNWARD LOAD OF 1.5 TIMES THE COMPONENT WEIGHT IN ACCORDANCE WITH UFC-4-010-01. THIS REQUIREMENT DOES NOT PRECLUDE REQUIREMENTS FOR SEISMIC ANCHORAGE IN ACCORDANCE WITH ASCE-7-05 AND THE PROJECT
SPECIFICATIONS.
USE COMMON GANG BOX WITH SEPARATION BETWEEN POWER AND TELECOM SECTIONS OR COMMON MOUNTING BRACKET SO THAT POWER AND TELECOM BOXES ARE NEATLY ALIGNED AND GROUPED WHERE POWER AND TELECOM OUTLETS ARE
SHOWN ADJACENT TO EACH OTHER.
WHERE OUTLETS AND DEVICES ARE IN HALF-WALLS OR WALLS WITH TRANSOMS, ROUTE CONDUITS FROM BELOW WITHIN
WALL.
STEPDOWN TRANSFORMERS MUST BE LABELED TO IDENTIFY THE LOCATION OF THE DISCONNECTING MEANS.
PROVIDE OFFSETS, TRANSITIONS, AND PULL BOXES AS NECESSARY TO ROUTE CONDUITS TO NOT INTERFERE WITH OTHER
CONDUITS AND SERVICES ABOVE CEILING AND UNDER RAISED ACCESS FLOOR.
FURNISH LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE PROPER AND COMPLETE INSTALLATION OF
ALL ELECTRIC WORK SHOWN ON THE DRAWINGS AND AS HEREIN SPECIFIED.
ALL ITEMS NOT SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE ELECTRICAL INSTALLATION, SHALL BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT.
CLEAN AT THE END OF EACH DAY ALL AREAS WORKED IN. EMPTY BOXES, RUBBISH, AND OTHER MATERIALS OF NO USE
SHALL BE REMOVED FROM THE SITE.
COORDINATE WORK SO THAT IT DOES NOT INTERFERE WITH THE WORK OF OTHER TRADES. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT HIS WORK IS INSTALLED IN A TIMELY MANNER.
ALL CUTTING, PATCHING AND FIRE STOPPING FOR ELECTRICAL INSTALLATION SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
ELECTRICAL ARRANGEMENTS AND LOCATIONS OF EQUIPMENT SHALL BE VERIFIED IN FIELD.
ALL WORK SHALL BE NEW, UNLESS NOTED OTHERWISE.
WHERE WIRING IS NOT IDENTIFIED, IT SHALL BE 2#12 (PHASE & NEUTRAL) CONDUCTORS AND 1#12 INSULATED GROUND IN 3/4
INCHES CONDUIT.
ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) AND SHALL BE IN A NEAT
PROFESSIONAL WORKMAN LIKE MANNER.
FURNISH AND INSTALL TESTED AND LISTED FIRESTOPPING SYSTEMS, COMBINATION OF MATERIALS, OR DEVICES TO FORM AN EFFECTIVE BARRIER AGAINST THE SPREAD OF FLAME, SMOKE AND GASES, AND MAINTAIN THE INTEGRITY OF FIRE RESISTANCE RATED WALLS, PARTITIONS, FLOORS, AND CEILING-FLOOR ASSEMBLIES, INCLUDING THROUGH-PENETRATIONS BY CONDUITS. FIRESTOPPING MATERIALS SHALL PROVIDE FIRE RESISTANCE RATING IN ACCORDANCE WITH ASTM E814 OR
UL 1479.
PROVIDE LABELS FOR ALL OUTLETS, INDICATING SOURCE PANELBOARD AND CIRCUIT NUMBER.
PROVIDE EQUIPMENT PAD FOR FLOOR MOUNTED EQUIPMENT. REFER TO STRUCTURAL DRAWINGS FOR EQUIPMENT PAD
DETAILS.
THE ELECTRICAL DISTRIBUTION SYSTEM HAS BEEN PRIVATIZED THROUGH THE ARMY'S UTILITY PRIVATIZATION (UP) INITIATIVE. THE ELECTRICAL SYSTEM OWNER (SO) IS CITY LIGHT AND POWER AWP, LLC (CLP). ALL WORK IMPACTING THE UTILITY ELECTRICAL DISTRIBUTION SYSTEM MUST BE COORDINATED WITH CLP. REFER TO CLP'S SERVICE CONNECTION
MANUAL FOR REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
E-001
G
EN
ER
AL
N O
TE
S, A N
D A
BB
R
EV
IA
TI
O
N S
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RACEWAYS AND WIRES
SWITCHES AND CONTROLSRECEPTACLES
SUBSCRIPTS: A1b = TYPE A, CIRCUIT 1, CONTROL ZONE b
RECESSED OR SURFACE 1 X 4 FIXTURE
WALL MOUNTED FIXTURE
EMERGENCY FIXTURE
RECESSED, CEILING OR PENDANT FIXTURE
LIGHTING FIXTURES
OCCUPANCY SENSOR, CEILING MOUNTED
SUBSCRIPTS NEXT TO RECEPTACLES, WHERE APPLICABLE: 1b = CIRCUIT 1, CONTROL ZONE b. POWER, P=PROJECTOR, GFI = GROUND FAULT INTERRUPTER, WP = WEATHERPROOF WHILE IN USE COVER, CT = COUNTER TOP HEIGHT, S = SPLIT WIRED SWITCHED, F = FLUSH FLOOR, SM = SURFACE MOUNT FLOOR, M = MONITOR, C = CONTROLLED, L = LED SIGNAGE, W = WALL PHONE RECEPTACLE, "+" = ABOVE COUNTER TOP RECEPTACLE
DUPLEX RECEPTACLE
SINGLE RECEPTACLE
QUADRUPLEX RECEPTACLE
SPECIAL RECEPTACLE, NEMA L5-50R
DUPLEX GFCI TYPE RECEPTACLE
DUPLEX CEILING RECEPTACLE
SUBSCRIPTS: 3b = TYPE 3, CONTROL ZONE b
3 = 3-WAY, 2 = DOUBLE POLE, 4 = 4 WAY,
D = LOW VOLTAGE DIMMER, K = KEY OPERATED, XP =
EXPLOSION PROOF, T = TIMER OPERATED,
L = LOW VOLTAGE, OC = OCCUPANCY SENSOR, F = FUSED, P
= PILOT LIGHT, M = MANUAL MOTOR STARTER
TIME CLOCK
PUSHBUTTON OR CONTROL STATION
PHOTOELECTRIC RELAY
CONTACTOR
MOTOR STARTER
COMBINATION MOTOR STARTER AND DISCONNECT SWITCH
COMBINATION MOTOR STARTER AND MOTOR CIRCUIT PROTECTOR
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
CONDUIT OR CABLE (RUN AS INDICATED)
CONDUIT OR CABLE TURNING UP
CONDUIT OR CABLE TURNING DOWN
CONDUIT CAPPED
OUTLET BOX WITH BLANK COVER
JUNCTION BOX CEILING MOUNTED
PULL BOX
SURFACE OR PENDANT STRIP FIXTURE
EMERGENCY FIXTURE
VACANCY SENSOR, CEILING MOUNTED
PRE-WIRED CONTROL PANEL
RECESSED, CEILING OR PENDANT HID WITH QUARTZ RE-STRIKE
EMERGENCY FIXTURE
WALL MOUNTED FIXTURE
SHADING INDICATES ILLUMINATED FACE OF EXIT SIGN
ARROW INDICATES EXIT SIGN DIRECTIONAL ARROW
WALL MOUNTED EXIT SIGN
CEILING OR PENDANT MOUNTED EXIT SIGN
SPOTLIGHT, ARROW INDICATES DIRECTION OF AIM
FLOODLIGHT
BATTERY PACK WITH HEADS
WALL WASHER
LINEAR WALL WASHER
ILLUMINATED BOLLARD
RECESSED OR SURFACE 2 X 4 FIXTURE
RECESSED OR SURFACE 2 X 2 FIXTURE
EMERGENCY FIXTURE
PENDANT LINEAR FIXTURE
QUADRUPLEX CEILING RECEPTACLE
SPECIAL PURPOSE RECEPTACLE, 120V, 20A, 1P, 3W, NEMA L5-20R MOUNTED TO CABLE TRAY
DISTRIBUTION EQUIPMENT
208/120V PANELBOARD
EMERGENCY LIGHTING PANELBOARD
480/277V PANELBOARD
EMERGENCY LIGHTING INVERTER
SWITCHBOARD
TRANSFORMER
MANUAL CONTROL STATION FOR LIGHTS. REFER TO LIGHTING CONTROL
ROOM SCHEDULE FOR REQUIRED CONTROL FEATURES FOR EACH ROOM.
3b
VARIABLE FREQUENCY DRIVE
JUNCTION BOX WALL MOUNTED
JUNCTION BOX FLOOR MOUNTED
ELECTRICAL SYMBOLS
RECESSED OR SURFACE 2 X 2 EMERGENCY FIXTURE
BURIED GROUNDING ELECTRODE
LIGHTNING PROTECTION CONDUCTOR
LIGHTNING PROTECTION CONDUCTOR, CHANGE IN ELEVATION
WELDED CONNECTION
BOLTED CONNECTION
GROUND ROD WITH WELDED CONNECTION
LIGHTNING PROTECTION AIR TERMINAL (LIGHTNING ROD)
GROUND ROD WITH TEST WELL
ELECTRICAL GROUND BUS (EGB); ELECTRICAL MAIN GROUND
BUS (EMGB)
GROUND
GROUNDING AND LIGHTNING PROTECTION
ROADWAY OR PARKING LOT STANDARD
POST TOP WALKWAY OR PARKING LOT STANDARD
BUILDING MOUNTED WALLPACK
LIGHTING TRACK WITH FIXTURES
DOCK LIGHT
STEP OR AISLE LIGHT
A
P
JUNCTION BOX WITH FLEXIBLE WHIP TO FURNITURE BASE POWER FEED
MECHANICAL EQUIPMENT
MOTOR
PE
VFD
PWCP
CONDUIT OR CABLE BELOW RAISED FLOOR
CONDUIT OR CABLE BELOW SLAB, IN SLAB OR UNDERGROUND
B
J
J
J
PB
ONE-LINE DIAGRAMS
FUSED CUTOUT
TRANSFORMER
(XX)
CURRENT TRANSFORMER
VOLTAGE TRANSFORMER
PANELBOARD
DISCONNECT SWITCH, 30 = AMPERE RATING
FUSE, (20) = AMPERE RATING
(20)
MOLDED CASE CIRCUIT BREAKER, 20 = TRIP RATING
DRAWOUT CIRCUIT BREAKER, 600 = TRIP RATING
SHUNT TRIPST
GROUND FAULT RELAYG
GROUND FAULT PROTECTIONGFP
SURGE PROTECTIVE DEVICESPD
AUTOMATIC OR MANUAL TRANSFER SWITCH
LIGHTNING ARRESTER
ELECTRICAL METER:M M = UTILITY METER
V = VOLT METER
W = WATT METER
PLUG-IN DISCONNECT SWITCH, FUSED 30 = SWITCH AMPERE
RATING (20) = FUSE AMPERE RATING
MOTOR STARTER, SINGLE SPEED 0 = STARTER SIZE
(20)
ALTERNATING MOTOR CONTROLLERALT
KIRK KEY INTERLOCK
BATTERY+ -
HOMERUN, N4-PNL-LA5-1A = PANEL DESTINATION, 2,4,6 = CIRCUITS
N4-PNL-LA5-1A:2,4,6
220V, 16A, SCHUKO TYPE F, 2 GANG SOCKET OUTLET
M
DUPLEX RECEPTACLE ABOVE COUNTER. MOUNT THE RECEPTACLE 6" ABOVE FINISHED COUNTER
B SPECIAL PURPOSE RECEPTACLE, 208V, 20A, 2P, 3W, NEMA L6-20R MOUNTED TO CABLE TRAY
FLUSH POKE-THROUGH WITH QUADRUPLEX OR DUPLEX POWER RECEPTACLE,
20A, 125V AC. LOCATE BASED ON ACTUAL FURNITURE LAYOUTS. POKE-THROUGH
MUST ACCOMODATE COMBINATION OF POWER, AND TELECOM DEVICES AT
LOCATIONS SHOWN. COORDINATE WITH TELECOM DRAWINGS FOR REQUIRED
TELECOM DEVICES.
ENCLOSED MOLDED CASE CIRCUIT BREAKER, 20 = TRIP RATING
A1b 1b
INV-1
LOAD-OPERABLE MANUAL SELECTOR SWITCH
G
LP
LP
+ DUPLEX GFCI RECEPTACLE ABOVE COUNTER, MOUNT THE RECEPTACLE 6" ABOVE FINISHED COUNTER
V
O
AUTOMATICALLY SWITCHED RECEPTACLE, RECEPTACLE CONTROLLED BY ROOM OCCUPANCY
SENSOR, OR VACANCY SENSOR
INDICATES EMERGENCY LIGHT FIXTURE(E)
SPECIAL PURPOSE RECEPTACLE, 120V, 20A, 1P, 3W, NEMA L5-30R MOUNTED TO CABLE TRAYC
K
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
E-002
SY
M
BO
LS
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
M
AR
K D
E
SC
R
IP
TI
O
N D
M
W
W
W
M
CB
E
CB
M
W
W
W W
S
W
W
EEE
W
CB
CULLUM HALL
BUILDING 605
4 STORY STONE
MASONRY
BUILDING
LINCOLN HALL
BUILDING 607
4 STORY STONE
MASONRY
BUILDING
LINCOLN HALL
BUILDING 607
5 STORY STONE
MASONRY
BUILDING
SD
SD
D
8" P V
C 8" P
V C
6" STEEL
6"
STEEL
C
E E E E E E E E E E E E E E E
E E
E E
E E
E
DN
W
E
W
E
ES
ES
EE
G G
G
C
S
APPROXIMATE LOCATION OF
EXISTING UNDERGROUND
UTILITY TUNNEL.
EE
EXTENT OF DEMOLITION
DEMOLISH ELECTRIC UTILITY
PRIMARY SERVICE BACK TO
EXISTING TO REMAIN UTILITY
MANHOLE, MH-27
E
EEEEEEE
E E
E
EEEEEEEEEEEEEEEEEE
E
E
MH-27
EXISTING TO REMAIN ELECTRIC
UTILITY MANHOLE
M-28
ES
ES
ES
ES
ES
ES
DA
TE
MA
RK
DE
SC
RI
PT
IO
N
DR
AW
N
BY
DE
SI
GN
ED
B Y:
SU
BM
IT
TE
D
BY
SI
ZE
CH
EC
KE
D
BY
IS
SU
E
DA
TE
CO
NT
RA
CT
N O.
SO
LIC
IT
AT
IO
N
NO
FI
LE
N
UM
BE
R:
SHEET ID
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
US Army Corps of Engineers
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N
EW
Y O
R K
W
2D S-
-C
-0
1- L
M
AR
C
H
AN
SI
D
W
2D S-
-R
-0
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
REVISED RTA SUBMISSION 3/1/2023
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
30' 60'0
N
A1 SITE DEMOLITION PLAN
SCALE: 1"=20'
YSYS
SI
TE
D
EM
O
LI
TI
O
N P
LA
N
ED100
GENERAL SHEET NOTES
1. COORDINATE ALL PRIMARY DEMOLITION WORK WITH CLP.
2. CITY LIGHT AND POWER (CLP) WILL BE RESPONSIBLE FOR
DISCONNECTING AND REMOVING THE EXISTING PRIMARY
CABLE FROM LINCOLN HALL TO MANHOLE MH-27.
3. CONTRACTOR WILL BE RESPONSIBLE FOR DEMOLISHING
CONDUITS, DUCTBANK, AND MANHOLES BETWEEN LINCOLN
HALL AND MH-27. REFER TO CIVIL PLANS FOR EXTENT OF
DUCTBANK DEMOLITION.
4. CONTRACTOR WILL BE RESPONSIBLE FOR DEMOLISHING
ALL SERVICE EQUIPMENT FROM LINCOLN HALL.
COORDINATE WITH CLP TO DE-ENERGIZE PRIMARY LINE.
5. UTILITY SERVICE CONDUITS THAT ARE RUN UNDER THE
FOOTPRINT OF THE BUILDING, THROUGH UNEXCAVATED
AREA SHALL BE ABANDONED IN PLACE. ABANDONED
CONDUCTORS SHALL BE TAGGED AND PROPERLY
IDENTIFIED AS DE-ENERGIZED.
6. COORDINATE WORK WITH CIVIL DEMOLITION PLANS.
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
CL S
CL N
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED101
LE
VE
L B3
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL B3 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
CL S
CL N
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED102
LE
VE
L B2
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL B2 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED103
LE
VE
L B1
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL B1 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED104
LE
VE
L
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL 1 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
CL S
CL N
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED105
LE
VE
L
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL 2 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED106
LE
VE
L
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL 3 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
CL S
CL N
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
MECHANICAL EQUIPMENT, DISCONNECTING MEANS AND CONTROL
DEVICES, AND WIRES AND CONDUITS WITHIN THE HATCHED AREA.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED107
LE
VE
L
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL 4 DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET ESD100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
3. REFER TO DRAWING SHEET ED601 FOR ELECTRICAL DEMOLITION RISER
DIAGRAM.
1. DEMOLISH ALL ELECTRICAL EQUIPMENT AND DEVICES, LUMINAIRES
(INTERIOR AND EXTERIOR) AND CONTROL DEVICES, CONNECTIONS TO
EQUIPMENT, DISCONNECTING MEANS AND CONTROL DEVICES, AND
WIRES AND CONDUITS WITHIN THE HATCHED AREA.
2. THERE IS NO LIGHTNING PROTECTION SYSTEM ON THE EXISTING ROOF.
DEMOLITION KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED108
R O
O F
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 ROOF DEMOLITION PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
3RD BASEMENT (B3 LEVEL)
2ND BASEMENT (B2 LEVEL)
1ST BASEMENT (B1 LEVEL)
1ST FLOOR (LEVEL 1)
2ND FLOOR (LEVEL 2)
3RD FLOOR (LEVEL 3)
4TH FLOOR (LEVEL 4)
4TH FLOOR ROOF (NORTH WING)
3RD FLOOR ATTIC (SOUTH WING)
DBH
1200A
HV-SW
T2
DBL
FA
CONTL
PANEL
LPL1BS
LPL
2BS
LPL1S
LPL2S
LPL3S
LPL1BN
LPH-2B
LPL1N
LPL2N
LPL3N
LPL4N
LPH1B
LPH1
LPH2
LPH3
LPH4
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
MAIN
ELECTRICAL
ROOM
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
T1
750KVA
4.16KV-
480/277
INCOMING 5KV CABLE IN
4" 2-WAY DUCT BANK
UTILITY TUNNEL
PP-2B LBH-
S&E
LPL-
3BN
LPH-3B
FIRE
PUMP
PP-3B
CHILLER
LPL2BN
MECHANICAL ROOM
MECHANICAL ROOM
MECHANICAL ROOM
UNIT SUBSTATION
UTILITY MANHOLE
(MH. 28) UTILITY MANHOLE
(MH. 27)
TO REMAIN
M
JOCKY
PUMP
ELEV
EXTENT OF
DEMOLITION
1 2
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO DRAWING SHEET E-602 FOR ELECTRICAL RISER DIAGRAMS.
3. REFER TO DRAWING SHEET E-601 FOR FEEDER SCHEDULE.
4. REFER TO E-700 SERIES DRAWINGS FOR ELECTRICAL PANEL SCHEDULES.
5. REFER TO DRAWING SHEET ED100 FOR ELECTRICAL SITE DEMOLITION
PLAN.
6. REFER TO DRAWING SHEET ES100 FOR NEW WORK ELECTRICAL SITE
PLAN.
7. DEMOLISH THE ELECTRICAL SYSTEM IN ITS ENTIRETY, INCLUDING THE
UTILITY SERVICE, BACK TO THE ELECTRICAL UITILITY MANHOLE ON THE
EAST SIDE OF THE BUILDING. REFER TO ELECTRICAL SITE DEMOLITION
PLAN ED100 FOR LOCATION OF THE UTILITY MANHOLE.
DEMOLITION KEYNOTES#
1. CITY LIGHT AND POWER (CLP) WILL BE RESPONSIBLE FOR DISCONNECTING
THE EXISTING PRIMARY CABLE FROM LINCOLN HALL TO MANHOLE MH-27.
2. CONTRACTOR WILL BE RESPONSIBLE FOR DEMOLISHING CONDUITS,
DUCTBANK, AND MANHOLES BETWEEN LINCOLN HALL AND MANHOLE MH-27.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
ED601
D E
M O
LI
TI
O N
R
IS
ER
D
IA
G R
AM
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
NTS1 DEMOLITION - RISER DIAGRAM
M
AR
K D
E
SC
R
IP
TI
O
N D
PRINTING/LAMINATING
STORAGE
B302
AV/EVENT
STORAGE
B304
RECYCLING
ROOM
B306
STAIR B
XB3-102
MECHANICAL
XB301
UNEXCAVATED
AREA
UNEXCAVATED
AREA
UNEXCAVATED
UNEXCAVATED
AREA
ELECTRICAL
B303
J(E) J
J J
J J J(E) J J(E)
J
J
J(E)
J(E)
J
J
J(E)
J J
J
J
J
J(E)
J
LOADING AREA
B301
CORRIDOR
B300A
UTILITY TUNNEL
UTILITY TUNNEL
XB300
C
JJ(E)
C C C(E)
W2 W2 W2 W2 W2
W1(E)
J J
B1(E)
B1(E)B1(E)
MECHANICAL
B305
EGRESS
CORRIDOR
B307
B1(E)
W3(E)
W3(E)
B1
C C(E) C C
B1 B1
J
J
J
X
X
X
X
G1(E)
2 2
2 2
2 2 2
X
19 19
EXISTING
ELEVATOR
SHAFT
212121 4 4 4 4 4
W2(E)
X 19
X 19
W2(E)W2(E)W2(E)
MECHANICAL
UNEXCAVATED
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO SHEET EL701 FOR LUMINAIRE SCHEDULE.
3. REFER TO EL702 FOR LIGHTING CONTROL ROOM SCHEDULE.
4. UNLESS OTHERWISE NOTED, ALL NORMAL LIGHT FIXTURES MUST BE
CIRCUITED TO PANEL HNB3.
5. UNLESS OTHERWISE NOTED, ALL EMERGENCY LIGHT FIXTURES AND EXIT
LIGHTS MUST BE CIRCUITED TO PANEL HB3-E.
6. ALL LIGHT FIXTURES TO BE MOUNTED 8'-0" AFF, UNLESS OTHERWISE
NOTED.
KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
EL101
LE
VE
L B3
L
IG
H
TI
N G
P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL B3 LIGHTING PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
1 INSTALL LIGHT FIXTURES IN THIS ROOM AT 7'-6"AFF TO BOTTOM OF LIGHT.
2 INSTALL LIGHT FIXTURES IN THIS ROOM AT 4'-0" AFF.
3 INSTALL LIGHT FIXTURES IN THIS ROOM 7'-0" AFF TO BOTTOM OF LIGHT.
4 INSTALL LIGHT FIXTURES IN THIS ROOM VERTICALLY AT 6'-0" AFF TO CENTER OF LIGHT.
STORAGE
B214
STAIR A
XB-201
BREAK ROOM
B213
WOMEN'S
RESTROOM
B211
EXISTING
CLOSET
B210
MULTI-MEDIA
ARCHIVE
B232
MECHANICAL
B233
STAIR B
XB2-102
STORAGE
B236
CUSTODIAL
B231
JAN CLOSET
B216
OFFICE
B222
CLIENT
SERVICES OPEN
OFFICE
B220
UNEXCAVATED
ELECTRICAL
CLOSET
B235
MEN'S
RESTROOM
B212
TELECOM
B237
STORAGE
B238
CORRIDOR
B2100B
CENTRAL STAIR
/ ENTRANCE
B201
J
J
J J
J
J
J
J(E)
J
J(E)
J
J(E)
J
G G G G G
G
G
G G
G
G
OFFICE
B226
OFFICE
B225
OFFICE
B224
OFFICE
B223
CORRIDOR
B2100A
OFFICE
B221
EXISTING
ELEVATOR
SHAFT
J
JJ(E)
J(E)
J
J(E)
J J
J
B
B B B(E)
B1(E) B1 B1 B1(E) B1 B1 B1(E) B1 B1 B1(E)J
J
J
J
B1(E)
B1
C(E)
C
C
C
C
C(E)
B1(E) B1 B1(E) J(E)
B1
B1(E)
B1
B1
B1(E)
B1
B1(E)
J
J(E)
J
J
J
A
AA
A A
A A
W1(E)
W1(E)
W1(E)
F
F
F
F
F
F
J
J
J
J(E)
J
J
J
J A A A A
J
G
G1(E)
W3(E)
W3(E)
B1
J(E)
J
W1(E)
A A(E)
AA
XX
X
X
X
J
X
W1(E)
X
ELECTRICAL
CLOSET
B215
X
3 3
2 2
2 2
4444444
6 6
J(E) 3 M M
13 13 13 13 13
13 13
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO SHEET EL701 FOR LUMINAIRE SCHEDULE.
3. REFER TO EL702 FOR LIGHTING CONTROL ROOM SCHEDULE.
4. UNLESS OTHERWISE NOTED, ALL NORMAL LIGHT FIXTURES MUST BE
CIRCUITED TO PANEL HNB2.
5. UNLESS OTHERWISE NOTED, ALL EMERGENCY LIGHT FIXTURES AND EXIT
LIGHTS MUST BE CIRCUITED TO PANEL HB2-E.
6. ALL LIGHT FIXTURES TO BE MOUNTED 8'-0" AFF, UNLESS OTHERWISE
NOTED.
KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
EL102
LE
VE
L B2
L
IG
H
TI
N G
P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL B2 LIGHTING PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
1 INSTALL LIGHT FIXTURES IN THIS ROOM AT 7'-6"AFF TO BOTTOM OF LIGHT.
2 INSTALL LIGHT FIXTURES IN THIS ROOM VERTICALLY AT 6'-0" AFF TO CENTER OF LIGHT.
3 INSTALL LIGHT FIXTURES IN THIS ROOM AT 7'-0" AFF TO TOP OF LIGHT.
OFFICE
B114
OFFICE
B152
OFFICE
B113
OFFICE
B115
OFFICE
B153
OFFICE
B144
OFFICE
B111
FIRE
PROTECTION
B106
STAIR A
XB1-101
OFFICE
B151
OFFICE
B141
OFFICE
B142
MEN'S
RESTROOM
B174
RECEIVING
B164
STAIR B
XB1-102
WOMEN'S
RESTROOM
B173
ELECTRICAL
CLOSET
B171
CORRIDOR
B100B
FIRE
PROTECTION
B105
OFFICE
B116
OFFICE
B112
COLLABORATIVE
SPACE
B120
WAITING AREA
B102
CENTRAL STAIR
B101
CORRIDOR
B1100A
EXISTING
ELEVATOR
SHAFT
ELECTRICAL
CLOSET
B107
AD LAW
CORRIDOR
B110
OPEN OFFICE
B140
AD LAW
CORRIDOR
B150
OFFICE
B154
OFFICE
B131
OFFICE
B134
OFFICE
B133
OFFICE
B132
MIL JUSTICE
OPEN OFFICE
B130
BREAK ROOM
B135
CORRIDOR
TELECOM
B172
J(E)
J J
J J
J
J
G
OFFICE
B143
OFFICE
B155
B(E) B B B(E) B B B(E) B B
B(E)
B B1(E)
J
J
J
J J(E)
B1(E)
B1
B1(E)
B(E)BBB(E)BBB
B B B(E) B B B(E)
J
JJ
B(E)
B
C
A
A
A
A
A
A
A A A
A
A
B
A
M
M
W1(E)
W1(E)
F
C C(E)
CC C(E)
FF
FFF
A
A A
BB(E) B
B(E)
B
A
AA
AAAA
A A A A
A
A
J J J(E)
J(E)J(E)J
B1
B1(E)
AA
A
A
A A A A A A A A
AV/EVENT
STORAGE
B165
A/V STAFF &
PHOTO EDITING
SUITE
B159
OFFICE
B158
OFFICE
B157
A/V STAFF &
PHOTO EDITING
SUITE
B156
D1
D1(E)
D1(E)
D1
D1
D1 D1
D1(E)
D1D1
W3(E)
W3(E)
JANITOR'S
CLOSET
B108
A A
A
B B
B
BB(E)
B(E) B
B
B(E) B
BB
B
A
A A
A
A
D1
D1(E)
J(E)
D1(E)
D1
B(E) B
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
2 2
W1(E)
W1(E)
X
2 2
B
2 2
2 2
1 1
2 2
2 2
2 2
2 2
2 2
3 3
4444444
6 6
6 6 6
6 6
6 6 6
3 6
8 8 8
8 8 8 8 8 8 8 8 8
8 8
8 8 8
8 8
88 8 8
8 8
8 8 8
B(E) B
J
J
J
4C
C
A(E)
A
A
GENERAL NOTES
1. REFER TO DRAWING SHEETS E-001, AND E-002 FOR ELECTRICAL
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
2. REFER TO SHEET EL701 FOR LUMINAIRE SCHEDULE.
3. REFER TO EL702 FOR LIGHTING CONTROL ROOM SCHEDULE.
4. UNLESS OTHERWISE NOTED, ALL NORMAL LIGHT FIXTURES MUST BE
CIRCUITED TO PANEL HNB1.
5. UNLESS OTHERWISE NOTED, ALL EMERGENCY LIGHT FIXTURES AND EXIT
LIGHTS MUST BE CIRCUITED TO PANEL HB1-E
6. ALL LIGHT FIXTURES TO BE MOUNTED 8'-0" AFF, UNLESS OTHERWISE
NOTED.
KEYNOTES#
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M B
ER
1 2 3 4 5
D
C
B
A
EL103
LE
VE
L B1
L
IG
H
TI
N G
P
LA
N
BU
IL
D
IN
G S
5/
R
EN
O
VA
TI
O
N
LI
N
C O
LN
H
AL
L
LI
N
C O
LN
H
AL
L
W
ES
T
PO
IN
T, N E
W Y
O R
K
D . P
AX
TO
N
D . P
AX
TO
N
Y.
S
O
LO
M O
N
M
A R
C H
W
2D S-
-R
-0
W
2D S-
-C
-0
1- L
REVISED RTA SUBMISSION 3/1/2023
1/8" = 1'-0"C1 LEVEL B1 LIGHTING PLAN
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
1 INSTALL LIGHT FIXTURES IN THIS ROOM 7'-0" AFF TO BOTTOM OF LIGHT.
2 INSTALL LIGHT FIXTURES IN THIS ROOM AT 7'-6"AFF TO BOTTOM OF LIGHT.
3 INSTALL LIGHT FIXTURES IN THIS ROOM VERTICALLY AT 6'-0" AFF TO CENTER OF LIGHT.
4 INSTALL LIGHT FIXTURE IN THIS ROOM AT 6'-6"AFF TO CENTERLINE OF LIGHT.
5 EXTERIOR LIGHT CIRCUITED TO PANEL HNB2.
OFFICE
OFFICE
OFFICE
OFFICE
INTERVIEW
ROOM
INTERVIEW
ROOM
RECEPTION
STAIR A
X1-101
VISITOR
BRIEFING ROOM
MEN'S
RESTROOM
WOMEN'S
RESTROOM
STAIR B
X1-102
RETAIL STORE
SUPPLY CLOSET
ELECTRICAL
CLOSET
OFFICE
OFFICE
OFFICE
ELECTRICAL
CLOSET
CORRIDOR
100B
CORRIDOR
100C
SERVICE
ELEVATOR
TELECOM
RETAIL OPEN
OFFICE
WAITING AREA
CENTRAL
STAIR/ENTRY
INTERVIEW
ROOM
BREAK ROOM
STORAGE
ADMISSIONS
OPEN OFFICE
ADMISSIONS
OPEN OFFICE
EXISTING
ELEVATOR
SHAFT
CORRIDOR
100A
CORRIDOR
100B
A
B
B
B1(E)
A
K
B1
F M
J
J
J(E)
J(E)
J
J(E)
C C C(E)
G1(E)
OFFICE
CORRIDOR
CAFE
B B(E) B B B(E) B
B1B1(E) B1(E) B1 B1(E) B1 B1(E) B1 B1(E)
J J
J J
A A
A
B B(E)
This is the start of the file's text. The full file is on GovTribe.