LH_VOLUME 01_Revised_RTA_2023-03-01.pdf
PDF 21 MB Posted
- Attached to
- LINCOLN HALL RENOVATION, BLDG. 607 Federal contract opportunity
- Solicitation number
- W912DS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Vol 1 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf | ||
| Vol 2 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf | ||
| LH_VOLUME 03_Revised_RTA_2023-03-01.pdf | ||
| LH_VOLUME 04_Revised_RTA_2023-03-01.pdf | ||
| JA 007-23 Distributed Antenna System.pdf | ||
| JA 010-23 Best Hardware Lock Cylinders and Cores.pdf | ||
| W912DS23R0009.pdf | ||
| Vol 3 WP Lincoln Hall Revised RTA Specifications 1 MAR 2023.pdf | ||
| LH_VOLUME 02_Revised_RTA_2023-03-01.pdf | ||
| JA 009-23 Avaya Switch.pdf | ||
| JA 011-23 Ventrol AHU.pdf | ||
| JA 012-23 Identiv Card Access System.pdf | ||
| JA 013-23 Monaco.pdf | ||
| JA 014-23 Shark Meter.pdf | ||
| JA 006-23 Belden Brick.pdf | ||
| JA 008-23-Ruabon Quarry Tile.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
D
C
B
A
US Army Corps of Engineers ®
USMA BUILDING 607 LINCOLN HALL RENOVATION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
CIVIL LANDSCAPE STRUCTURAL ARCHITECTURE INTERIORS
FIRE PROTECTION
LIFE SAFTEY
PLUMBING
MECHANICAL
ELECTRICAL
TELECOM
SECURITY
HAZMAT
NO SEAL
SHEETS ARE FOR
BIDDING AND
INFORMATION
ONLY
D3296400
REVISED RTA SUBMISSION
03/01/2023
ISSUE DATE: 01 MARCH 2023
WEST POINT, NY
CONTRACT NUMBER : W912DS-19-C-0031-L
SOLICITATION NUMBER : W912DS-19-R-0014
G-011
C O
V E
R S
H E
E T
V
O L U
M E
O N
E
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
LINCO
LN HALL
VOLUME ONE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
G-012
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
O N
E A
N D
T W
O
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
NUMBER DRAWING NAME
LIFE SAFETY
LS001 LIFE SAFETY CODE SUMMARY
LS101 LEVEL B3 FLOOR PLAN - LIFE SAFETY
LS102 LEVEL B2 FLOOR PLAN - LIFE SAFETY
LS103 LEVEL B1 FLOOR PLAN - LIFE SAFETY
LS104 LEVEL 1 FLOOR PLAN - LIFE SAFETY
LS105 LEVEL 2 FLOOR PLAN - LIFE SAFETY
LS106 LEVEL 3 FLOOR PLAN - LIFE SAFETY
LS107 LEVEL 4 FLOOR PLAN - LIFE SAFETY
HAZARDOUS
H-101 LEVEL B3 HAZMAT PLAN
H-102 LEVEL B2 HAZMAT PLAN
H-103 LEVEL B1 HAZMAT PLAN
H-104 LEVEL 1 HAZMAT PLAN
H-105 LEVEL 2 HAZMAT PLAN
H-106 LEVEL 3 HAZMAT PLAN
H-107 LEVEL 4 HAZMAT PLAN
CIVIL
C-001 GENERAL NOTES
C-002 GENERAL NOTES, LEGEND, AND ABBREVIATIONS
BB501 SOIL BORING LOG
C-101 EXISTING CONDITIONS PLAN
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CS102 TRUCK ACCESS PLAN
CS103 CONSTRUCTION LOGISTICS PLAN
CG101 GRADING AND DRAINAGE PLAN
CG102 SOIL EROSION PLAN
CU101 UTILITY PLAN
C-201 DRAINAGE PROFILE
C-501 CONSTRUCTION DETAILS
C-502 CONSTRUCTION DETAILS
C-503 CONSTRUCTION DETAILS
C-504 CONSTRUCTION DETAILS
C-505 CONSTRUCTION DETAILS
C-506 CONSTRUCTION DETAILS
LANDSCAPE
L-101 LANDSCAPE PLAN
L-501 LANDSCAPE DETAILS
L-502 LANDSCAPE DETAILS
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES
S-002 STRUCTURAL ABBREVIATIONS, SYMBOLS, LEGEND
S-010 LOAD PLANS
S-011 SNOW AND WIND LOADING PLANS
SD101 LEVEL B3 DEMOLITION PLAN
SD102 LEVEL B2 DEMOLITION PLAN
SD103 LEVEL B1 DEMOLITION PLAN
SD104 LEVEL 1 DEMOLITION PLAN
SD105 LEVEL 2 DEMOLITION PLAN
SD106 LEVEL 3 DEMOLITION PLAN
SD107 LEVEL 4/ROOF DEMOLITION PLAN - SOUTH WING
SD108 ROOF DEMOLITION PLAN - NORTH WING AND TOWER
SD401 LARGE SCALE VIEWS
SD402 LARGE SCALE VIEWS
S-101 LEVEL B3 FLOOR PLAN
S-102 LEVEL B2 FLOOR PLAN
S-103 LEVEL B1 FLOOR PLAN
S-104 LEVEL1 FLOOR PLAN
S-105 LEVEL2 FLOOR PLAN
S-106 LEVEL3 FLOOR PLAN
S-107 LEVEL 4/ROOF PLAN - SOUTH WING
S-108 ROOF PLAN - NORTH WING AND TOWER
S-201 ELEVATIONS
S-401 LARGE SCALE VIEWS
S-402 LARGE SCALE VIEWS
S-403 LARGE SCALE VIEWS
S-404 LARGE SCALE VIEWS
S-501 TYPICAL DETAILS - FOUNDATIONS, WALLS, SLABS-ON-GRADE, SLABS
S-502 TYPICAL DETAILS - DEVELOPMENT LENGTHS, POST-INSTALLED ANCHORS, STEEL BEAMS
S-503 TYPICAL DETAILS - STEEL BEAMS AND LINTELS
S-504 TYPICAL DETAILS - STEEL BEAMS AND LINTELS
S-505 TYPICAL DETAILS - STEEL DETAILS
NUMBER DRAWING NAME
GENERAL
G-011 COVER SHEET - VOLUME ONE
G-012 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-013 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
INDEX OF DRAWINGS - VOLUME ONE INDEX OF DRAWINGS - VOLUME TWO
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
NUMBER DRAWING NAME
A-511 EXTERIOR DETAILS
A-512 EXTERIOR DETAILS
A-513 EXTERIOR DETAILS
A-514 EXTERIOR DETAILS
A-521 WINDOW DETAILS
A-522 WINDOW DETAILS
A-523 WINDOW DETAILS
A-531 ROOF DETAILS
A-532 ROOF DETAILS
A-533 STAIR TOWER ATTIC ACCESS DETAILS
A-541 EXTERIOR GUARDRAIL AND HANDRAIL DETAILS
A-542 RETAIL STORE STAIR DETAILS
A-543 RETAIL STORE STAIR DETAILS
A-545 INTERIOR STAIR DETAILS
A-546 INTERIOR STAIR DETAILS
A-551 CEILING DETAILS
A-552 TV STUDIO CEILING AND PARTITION DETAILS
A-553 TV STUDIO CEILING DETAILS
A-554 TV STUDIO CEILING DETAILS
A-561 MILLWORK DETAILS - CAFE
A-562 MILLWORK DETAILS - BRIEFING ROOM
A-563 MILLWORK DETAILS - TYPICAL
A-564 MILLWORK DETAILS - TYPICAL
A-601 PARTITION TYPES
A-602 PARTITION TYPES
A-604 DOOR SCHEDULE AND DETAILS
A-605 DOOR SCHEDULE AND DETAILS
A-606 GLAZED PARTITION AND DOOR DETAILS
A-607 DOOR DETAILS
A-608 DOOR DETAILS
A-609 EXTERIOR DOOR DETAILS
A-610 EXTERIOR DOOR DETAILS
A-615 WINDOW TYPES AND SCHEDULE
A-620 INTERIOR ALUMINUM FRAME SYSTEM
A-621 INTERIOR ALUMINUM FRAME SYSTEM
A-901 EXTERIOR RESTORATION ELEVATIONS
A-902 EXTERIOR RESTORATION ELEVATIONS
A-903 EXTERIOR RESTORATION ELEVATIONS
A-904 EXTERIOR RESTORATION ELEVATIONS
A-905 EXTERIOR RESTORATION ELEVATIONS
A-906 EXTERIOR RESTORATION ELEVATIONS
A-907 EXTERIOR RESTORATION ELEVATIONS
ARCHITECTURAL SIGNAGE
AG001 SITE SIGNAGE PLAN
AG101 LEVEL B3 FLOOR PLAN -SIGNAGE
AG102 LEVEL B2 FLOOR PLAN - SIGNAGE
AG103 LEVEL B1 FLOOR PLAN - SIGNAGE
AG104 LEVEL 1 FLOOR PLAN - SIGNAGE
AG105 LEVEL 2 FLOOR PLAN - SIGNAGE
AG106 LEVEL 3 FLOOR PLAN - SIGNAGE
AG107 LEVEL 4 FLOOR PLAN - SIGNAGE
AG201 SIGNAGE - EXTERIOR SIGN ELEVATIONS
AG202 SIGNAGE - INTERIOR SIGN ELEVATIONS
AG203 SIGNAGE - INTERIOR SIGN ELEVATIONS
AG501 SIGNAGE LAYOUTS
AG502 SIGNAGE LAYOUTS
AG601 SIGNAGE SCHEDULE
INTERIOR
I-101 LEVEL B3 FLOOR PLAN - FINISH
I-102 LEVEL B2 FLOOR PLAN - FINISH
I-103 LEVEL B1 FLOOR PLAN - FINISH
I-104 LEVEL 1 FLOOR PLAN - FINISH
I-105 LEVEL 2 FLOOR PLAN - FINISH
I-106 LEVEL 3 FLOOR PLAN - FINISH
I-107 LEVEL 4 FLOOR PLAN - FINISH
I-111 LEVEL B3 FLOOR PLAN - FURNITURE
I-112 LEVEL B2 FLOOR PLAN - FURNITURE
I-113 LEVEL B1 FLOOR PLAN - FURNITURE
I-114 LEVEL 1 FLOOR PLAN - FURNITURE
I-115 LEVEL 2 FLOOR PLAN - FURNITURE
I-116 LEVEL 3 FLOOR PLAN - FURNITURE
I-117 LEVEL 4 FLOOR PLAN - FURNITURE
I-400 ENLARGED FINISH FLOOR PLANS - CORRIDORS
I-401 ENLARGED FINISH FLOOR PLANS - CORRIDORS, CAFE, RESTROOMS
I-402 ENLARGED FINISH FLOOR PLANS - RETAIL STORE, CORRIDOR
I-403 ENLARGED FINISH FLOOR PLANS - CORRIDORS
I-404 ENLARGED FINISH FLOOR PLANS - CENTRAL STAIR
I-405 ENLARGED FINISH FLOOR PLANS - CENTRAL STAIR, BREAK ROOMS
I-406 ENLARGED FINISH FLOOR PLANS - PHOTO STUDIO
I-500 INTERIOR DETAILS
I-501 INTERIOR DETAILS
I-600 COLOR MATERIAL LEGEND
I-601 COLOR MATERIAL LEGEND
I-602 FINISH MATERIAL SCHEDULE
I-603 FINISH MATERIAL SCHEDULE
I-604 FINISH MATERIAL SCHEDULE
NUMBER DRAWING NAME
ARCHITECTURAL
A-001 ABBREVIATIONS, MOUNTING HEIGHTS, AND SYMBOLS
AD101 LEVEL B3 DEMOLITION PLAN
AD102 LEVEL B2 DEMOLITION PLAN
AD103 LEVEL B1 DEMOLITION PLAN
AD104 LEVEL 1 DEMOLITION PLAN
AD105 LEVEL 2 DEMOLITION PLAN
AD106 LEVEL 3 DEMOLITION PLAN
AD107 LEVEL 4 DEMOLITION PLAN
AD108 ROOF DEMOLITION PLAN
A-101 LEVEL B3 FLOOR PLAN
A-102 LEVEL B2 FLOOR PLAN
A-103 LEVEL B1 FLOOR PLAN
A-104 LEVEL 1 FLOOR PLAN
A-105 LEVEL 2 FLOOR PLAN
A-106 LEVEL 3 FLOOR PLAN
A-107 LEVEL 4 FLOOR PLAN
A-108 ROOF PLAN
A-111 LEVEL B3 REFLECTED CEILING PLAN
A-112 LEVEL B2 REFLECTED CEILING PLAN
A-113 LEVEL B1 REFLECTED CEILING PLAN
A-114 LEVEL 1 REFLECTED CEILING PLAN
A-115 LEVEL 2 REFLECTED CEILING PLAN
A-116 LEVEL 3 REFLECTED CEILING PLAN
A-117 LEVEL 4 REFLECTED CEILING PLAN
A-201 SOUTH WING ELEVATIONS
A-202 SOUTH WING ELEVATIONS
A-203 NORTH WING AND TOWER ELEVATIONS
A-204 NORTH WING AND TOWER ELEVATIONS
A-205 ENLARGED ELEVATIONS - PENTHOUSE AND SALLY PORT
A-206 ENLARGED EXTERIOR ELEVATIONS, RETAINING WALLS
A-211 EXTERIOR WALL TYPICAL CONDITION PHOTOS
A-212 EXTERIOR WALL TYPICAL CONDITIONS PHOTOS
A-301 SOUTH WING BUILDING SECTION
A-302 SOUTH AND NORTH WING BUILDING SECTIONS
A-303 NORTH WING BUILDING SECTIONS
A-311 PARTIAL BUILDING SECTIONS
A-321 EXTERIOR WALL/ROOF SECTIONS PENTHOUSE
A-322 SHAFT SECTIONS
A-401 ENLARGED RESTROOM FLOOR PLANS
A-402 LEVEL B2 - ENLARGED CENTRAL STAIR FLOOR PLANS
A-403 LEVEL 1 AND 2 - ENLARGED CENTRAL STAIR FLOOR PLANS
A-404 LEVEL 3 AND 4 - ENLARGED CENTRAL STAIR FLOOR PLANS
A-405 ENLARGED CENTRAL STAIR RCPS
A-406 INTERIOR STAIRS ENLARGED PLANS & SECTIONS
A-407 ELEVATOR FLOOR PLANS, SECTIONS AND ELEVATIONS
A-411 CENTRAL STAIR TOWER SECTIONS/ELEVATIONS
A-412 CENTRAL STAIR LOBBY ELEVATIONS
A-413 CENTRAL STAIR LOBBY ELEVATIONS
A-414 CENTRAL STAIR LOBBY ELEVATIONS
A-415 CENTRAL STAIR LOBBY ELEVATIONS
A-421 CAFE ENLARGED PLANS AND ELEVATIONS
A-423 RETAIL STORE ENLARGED PLANS
A-424 RETAIL STORE ENLARGED PLANS
A-425 RETAIL STORE ELEVATIONS
A-426 RETAIL STORE ELEVATIONS AND DETAILS
A-427 RETAIL STORE DISPLAY WINDOW ELEVATIONS
A-428 RETAIL STORE PERSPECTIVE VIEWS AND DETAILS
A-429 ENLARGED BRIEFING ROOM PLANS AND ELEVATIONS
A-430 ENLARGED TV STUDIO PLANS
A-431 ENLARGED TV STUDIO SECTIONS/ELEVATIONS
A-432 INTERIOR ELEVATIONS - TV STUDIO
A-433 ENLARGED BREAK ROOM PLANS AND ELEVATIONS
A-434 ENLARGED CONFERENCE ROOM PLANS AND ELEVATIONS
A-435 ENLARGED CONFERENCE ROOM PLANS AND ELEVATIONS
A-436 OPEN OFFICE ENLARGED EXTERIOR WALL ELEVATIONS
A-437 OPEN OFFICE ENLARGED EXTERIOR WALL ELEVATIONS
A-439 ENLARGED PHOTO STUDIO PLANS AND ELEVATIONS
A-440 ENLARGED CHANGING ROOM PLANS AND ELEVATIONS
NUMBER DRAWING NAME
GENERAL
G-021 COVER SHEET - VOLUME TWO
G-022 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-023 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
G-013
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
T H
R E
E A
N D
F O
U R
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D M
A N
T Y
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
NUMBER DRAWING NAME
MECHANICAL
M-001 HVAC LEGEND
M-002 HVAC LEGEND
MD101 LEVEL B3 DEMOLITION PLAN - HVAC
MD102 LEVEL B2 DEMOLITION PLAN - HVAC
MD103 LEVEL B1 DEMOLITION PLAN - HVAC
MD104 LEVEL 1 DEMOLITION PLAN - HVAC
MD105 LEVEL 2 DEMOLITION PLAN - HVAC
MD106 LEVEL 3 DEMOLITION PLAN - HVAC
MD107 LEVEL 4 DEMOLITION PLAN - HVAC
MD108 ROOF DEMOLITION PLAN - HVAC
MH101 LEVEL B3 FLOOR PLAN - DUCTWORK
MH102 LEVEL B2 FLOOR PLAN - DUCTWORK
MH103 LEVEL B1 FLOOR PLAN - DUCTWORK
MH104 LEVEL 1 FLOOR PLAN - DUCTWORK
MH105 LEVEL 2 FLOOR PLAN - DUCTWORK
MH106 LEVEL 3 FLOOR PLAN - DUCTWORK
MH107 LEVEL 4 FLOOR PLAN - DUCTWORK
MH108 ROOF PLAN - DUCTWORK
MP101 LEVEL B3 FLOOR PLAN - PIPING
MP102 LEVEL B2 FLOOR PLAN - PIPING
MP103 LEVEL B1 FLOOR PLAN - PIPING
MP104 LEVEL 1 FLOOR PLAN - PIPING
MP105 LEVEL 2 FLOOR PLAN - PIPING
MP106 LEVEL 3 FLOOR PLAN - PIPING
MP107 LEVEL 4 FLOOR PLAN - PIPING
MP108 ROOF PLAN - PIPING
M-301 MECHANICAL SECTIONS - HVAC SHAFTS
M-302 MECHANICAL SECTIONS
M-303 MECHANICAL SECTIONS
M-401 HVAC ENLARGED PLANS
M-402 HVAC ENLARGED PLANS
M-501 HVAC DETAILS
M-502 HVAC DETAILS
M-503 HVAC DETAILS
M-504 HVAC DETAILS
M-505 HVAC DETAILS
M-506 HVAC DETAILS
M-507 HVAC DETAILS
M-601 HVAC SCHEDULES
M-602 HVAC SCHEDULES
M-603 HVAC SCHEDULES
M-604 HVAC SCHEDULES
M-605 HVAC SCHEDULES
M-701 STEAM AND HOT WATER FLOW DIAGRAM
M-702 CHILLED WATER FLOW DIAGRAMS - CAMPUS CHW AND CHILLED BEAM LOOP
M-703 HYDRONIC FLOW DIAGRAM - LEVEL B2 AND B3
M-704 HYDRONIC FLOW DIAGRAM - LEVEL B1
M-705 HYDRONIC FLOW DIAGRAM - LEVEL 1
M-706 HYDRONIC FLOW DIAGRAM - LEVEL 2
M-707 HYDRONIC FLOW DIAGRAM - LEVEL 3
M-708 HYDRONIC FLOW DIAGRAM - LEVEL 4 AND ROOF
M-709 AIRFLOW RISER DIAGRAM - DOAS-1
M-710 AIRFLOW RISER DIAGRAM - DOAS-2
M-711 AIRFLOW RISER DIAGRAM - MAU-1
M-801 CONTROL SCHEMATIC SYMBOLS, ABBREVIATIONS AND ACRONYMS
M-802 HVAC CONTROL DIAGRAM
M-803 HVAC CONTROL DIAGRAM
M-804 HVAC CONTROL DIAGRAM
M-805 HVAC CONTROL DIAGRAM
M-806 HVAC CONTROL DIAGRAM
M-807 HVAC CONTROL DIAGRAM
M-808 HVAC CONTROL DIAGRAM
M-809 HVAC CONTROL DIAGRAM
M-810 HVAC CONTROL DIAGRAM
M-811 HVAC CONTROL DIAGRAM
M-812 HVAC CONTROL DIAGRAM
M-813 HVAC CONTROL DIAGRAM
M-814 HVAC CONTROL DIAGRAM
M-815 HVAC CONTROL DIAGRAM
M-816 HVAC CONTROL DIAGRAM
M-817 HVAC CONTROL DIAGRAM
M-818 HVAC CONTROL DIAGRAM
M-819 HVAC CONTROL DIAGRAM
M-820 HVAC CONTROL DIAGRAM
M-821 HVAC CONTROL DIAGRAM
M-822 HVAC CONTROL DIAGRAM
M-823 HVAC CONTROL DIAGRAM
M-824 HVAC CONTROL POINTS SCHEDULE
M-825 HVAC CONTROL POINTS SCHEDULE
M-826 HVAC CONTROL POINTS SCHEDULE
M-827 HVAC CONTROL POINTS SCHEDULE
M-828 HVAC CONTROL POINTS SCHEDULE
M-829 HVAC CONTROL POINTS SCHEDULE
M-830 HVAC CONTROL POINTS SCHEDULE
M-831 HVAC CONTROL POINTS SCHEDULE
M-832 HVAC CONTROL POINTS SCHEDULE
M-833 HVAC CONTROL POINTS SCHEDULE
M-834 HVAC CONTROL POINTS SCHEDULE
M-835 HVAC CONTROL POINTS SCHEDULE
M-836 HVAC CONTROL POINTS SCHEDULE
M-837 HVAC CONTROL POINTS SCHEDULE
M-838 HVAC CONTROL POINTS SCHEDULE
M-839 HVAC CONTROL POINTS SCHEDULE
M-840 HVAC CONTROL POINTS SCHEDULE
M-841 HVAC CONTROL POINTS SCHEDULE
M-842 HVAC CONTROL POINTS SCHEDULE
M-843 HVAC CONTROL POINTS SCHEDULE
M-844 HVAC CONTROL POINTS SCHEDULE
M-845 UMCS SCHEDULES
M-846 THERMOSTAT SCHEDULE
M-847 THERMOSTAT SCHEDULE
M-848 VALVE & DAMPER SCHEDULES
NUMBER DRAWING NAME
FIRE ALARM
FA001 FIRE ALARM - SYMBOLS, ABBREVIATIONS, GENERAL NOTES, AND MASS NOTIFICATION
FD101 LEVEL B3 DEMOLITION PLAN - FIRE ALARM
FD102 LEVEL B2 DEMOLITION PLAN - FIRE ALARM
FD103 LEVEL B1 DEMOLITION PLAN - FIRE ALARM
FD104 LEVEL 1 DEMOLITION PLAN - FIRE ALARM
FD105 LEVEL 2 DEMOLITION PLAN - FIRE ALARM
FD106 LEVEL 3 DEMOLITION PLAN - FIRE ALARM
FD107 LEVEL 4 DEMOLITION PLAN - FIRE ALARM
FA101 LEVEL B3 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA102 LEVEL B2 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA103 LEVEL B1 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA104 LEVEL 1 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA105 LEVEL 2 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA106 LEVEL 3 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA107 LEVEL 4 FLOOR PLAN - FIRE ALARM AND MASS NOTIFICATION
FA108 ROOF PLAN - FIRE ALARM PLAN AND MASS NOTIFICATION
FA701 FIRE ALARM AND MASS NOTIFICATION DETAILS
FA702 FIRE ALARM AND MASS NOTIFICATION DETAILS
FA703 FIRE ALARM AND MASS NOTIFICATION DETAILS
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION - SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
FD111 LEVEL B3 DEMOLITION PLAN - FIRE SUPPRESSION
FD112 LEVEL B2 DEMOLITION PLAN - FIRE SUPPRESSION
FD113 LEVEL B1 DEMOLITION PLAN - FIRE SUPPRESSION
FD114 LEVEL 1 DEMOLITION PLAN - FIRE SUPPRESSION
FD115 LEVEL 2 DEMOLITION PLAN - FIRE SUPPRESSION
FD116 LEVEL 3 DEMOLITION PLAN - FIRE SUPPRESSION
FD117 LEVEL 4 DEMOLITION PLAN - FIRE SUPRESSION
FX101 LEVEL B3 FLOOR PLAN - FIRE SUPPRESSION
FX102 LEVEL B2 FLOOR PLAN - FIRE SUPPRESSION
FX103 LEVEL B1 FLOOR PLAN - FIRE SUPPRESSION
FX104 LEVEL 1 FLOOR PLAN - FIRE SUPPRESSION
FX105 LEVEL 2 FLOOR PLAN - FIRE SUPPRESSION
FX106 LEVEL 3 FLOOR PLAN - FIRE SUPPRESSION
FX107 LEVEL 4 FLOOR PLAN - FIRE SUPPRESSION
FX108 ROOF PLAN - FIRE SUPPRESSION PLAN
FX501 FIRE SUPPRESSION DETAILS
FX502 FIRE SUPPRESSION DETAILS
PLUMBING
P-001 PLUMBING ABBREVIATIONS, SYMBOLS AND GENERAL NOTES
PD101 LEVEL B3 DEMOLITION PLAN - PLUMBING
PD102 LEVEL B2 DEMOLITION PLAN - PLUMBING
PD103 LEVEL B1 DEMOLITION PLAN - PLUMBING
PD104 LEVEL 1 DEMOLITION PLAN - PLUMBING
PD105 LEVEL 2 DEMOLITION PLAN - PLUMBING
PD106 LEVEL 3 DEMOLITION PLAN - PLUMBING
PD107 LEVEL 4 DEMOLITION PLAN - PLUMBING
PD108 ROOF DEMOLITION PLAN - PLUMBING
P-101 LEVEL B3 FLOOR PLAN - PLUMBING
P-102 LEVEL B2 FLOOR PLAN - PLUMBING
P-103 LEVEL B1 FLOOR PLAN - PLUMBING
P-104 LEVEL 1 FLOOR PLAN - PLUMBING
P-105 LEVEL 2 FLOOR PLAN - PLUMBING
P-106 LEVEL 3 FLOOR PLAN - PLUMBING
P-107 LEVEL 4 FLOOR PLAN - PLUMBING
P-108 ROOF PLAN - PLUMBING
P-401 TOILET ENLARGED PLANS
P-402 TOILET ENLARGED PLANS
P-403 ENLARGED PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-503 PLUMBING DETAILS
P-604 SCHEDULES
P-701 DOMESTIC WATER RISER DIAGRAMS
P-702 SANITARY AND VENT RISER DIAGRAMS
P-703 STORM WATER RISER DIAGRAMS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
INDEX OF DRAWINGS - VOLUME THREE INDEX OF DRAWINGS - VOLUME FOUR
NUMBER DRAWING NAME
TELECOMMUNICATIONS
T-001 SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
TD101 LEVEL B3 COMMUNICATION DEMOLITION PLAN
TD102 LEVEL B2 COMMUNICATIONS DEMOLITION PLAN
TD103 LEVEL B1 COMMUNICATIONS DEMOLITION PLAN
TD104 LEVEL 1 - COMMUNICATIONS DEMOLITION PLAN
TD105 LEVEL 2 - COMMUNICATIONS DEMOLITION PLAN
TD106 LEVEL 3 - COMMUNICATIONS DEMOLITION PLAN
TD107 LEVEL 4 - COMMUNICATIONS DEMOLITION PLAN
TS101 PARTIAL TELECOM SITE PLAN
TS102 PARTIAL TELECOM SITE PLAN
T-101 LEVEL B3 FLOOR PLAN - COMMUNICATIONS
T-102 LEVEL B2 FLOOR PLAN - COMMUNICATIONS
T-103 LEVEL B1 FLOOR PLAN - COMMUNICATIONS
T-104 LEVEL 1 FLOOR PLAN - COMMUNICATIONS
T-105 LEVEL 2 FLOOR PLAN - COMMUNICATIONS
T-106 LEVEL 3 FLOOR PLAN - COMMUNICATIONS
T-107 LEVEL 4 FLOOR PLAN - COMMUNICATIONS
TY101 LEVEL B3 FLOOR PLAN - SECURITY
TY102 LEVEL B2 FLOOR PLAN - SECURITY
TY103 LEVEL B1 FLOOR PLAN - SECURITY
TY104 LEVEL 1 FLOOR PLAN - SECURITY
TY105 LEVEL 2 FLOOR PLAN - SECURITY
TY106 LEVEL 3 FLOOR PLAN - SECURITY
TY107 LEVEL 4 FLOOR PLAN - SECURITY
TY501 SECURITY DOOR AND CAMERA DETAILS
TY601 SECURITY PATHWAY DIAGRAM
T-201 RACK ELEVATIONS
T-202 RACK ELEVATIONS
T-203 RACK ELEVATIONS
T-204 RACK ELEVATIONS
T-401 ENLARGED TELECOM ROOM PLANS
T-402 ENLARGED TELECOM ROOM PLANS
T-403 ENLARGED TELECOM ROOM PLANS
T-404 ENLARGED TELECOM ROOM PLANS
T-501 COMMUNICATIONS OUTLET DETAILS
T-502 COMMUNICATIONS DETAILS
T-503 GROUNDING AND BONDING DETAILS
T-504 CABLE TRAY DETAILS
T-600 VOICE AND DATA OSP ONE-LINE DIAGRAM
T-601 NIPR VOICE AND DATA ONE-LINE DIAGRAM
T-602 WREN AND WAP DATA ONE-LINE DIAGRAM
T-603 F-DAS, C-DAS AND CLOCK ONE-LINE DIAGRAM
T-604 TELECOM BONDING AND GROUNDING ONE-LINE DIAGRAM
NUMBER DRAWING NAME
ELECTRICAL
E-001 GENERAL NOTES, AND ABBREVIATIONS
E-002 SYMBOLS
ED100 SITE DEMOLITION PLAN
ED101 LEVEL B3 DEMOLITION PLAN
ED102 LEVEL B2 DEMOLITION PLAN
ED103 LEVEL B1 DEMOLITION PLAN
ED104 LEVEL 1 DEMOLITION PLAN
ED105 LEVEL 2 DEMOLITION PLAN
ED106 LEVEL 3 DEMOLITION PLAN
ED107 LEVEL 4 DEMOLITION PLAN
ED108 ROOF DEMOLITION PLAN
ED601 DEMOLITION - RISER DIAGRAM
EL101 LEVEL B3 LIGHTING PLAN
EL102 LEVEL B2 LIGHTING PLAN
EL103 LEVEL B1 LIGHTING PLAN
EL104 LEVEL 1 LIGHTING PLAN
EL105 LEVEL 2 LIGHTING PLAN
EL106 LEVEL 3 LIGHTING PLAN
EL107 LEVEL 4 LIGHTING PLAN
EL108 ROOF LIGHTING PLAN
EL701 LUMINAIRE SCHEDULE
EL702 LIGHTING CONTROL SCHEDULES
EL703 LIGHTING CONTROL SCHEDULES
ES100 SITE PLAN
EP101 LEVEL B3 POWER PLAN
EP102 LEVEL B2 POWER PLAN
EP103 LEVEL B1 POWER PLAN
EP104 LEVEL 1 POWER PLAN
EP105 LEVEL 2 POWER PLAN
EP106 LEVEL 3 POWER PLAN
EP107 LEVEL 4 POWER PLAN
EP108 ELECTRICAL ROOF POWER PLAN
EP401 ELARGED POWER PLANS
EP402 ENLARGED POWER PLANS
EM101 ELECTRICAL LEVEL B3 EQUIPMENT PLAN
EM102 ELECTRICAL LEVEL B2 EQUIPMENT PLAN
EM103 ELECTRICAL LEVEL B1 EQUIPMENT PLAN
EM104 ELECTRICAL LEVEL 1 EQUIPMENT PLAN
EM105 ELECTRICAL LEVEL 2 EQUIPMENT PLAN
EM106 ELECTRICAL LEVEL 3 EQUIPMENT PLAN
EM107 ELECTRICAL LEVEL 4 EQUIPMENT PLAN
EM108 ELECTRICAL ROOF EQUIPMENT PLAN
EM701 MECHANICAL EQUIPMENT SCHEDULE
EG101 LEVEL B1 GROUNDING PLAN
EG102 ROOF LIGHTNING PROTECTION PLAN
EG601 GROUNDING RISER DIAGRAM
E-501 DETAILS
E-502 DETAILS
E-503 DETAILS
E-504 DETAILS
E-505 DETAILS
E-601 SINGLE LINE DIAGRAM
E-602 POWER RISER DIAGRAM
E-700 ELECTRICAL PANEL SCHEDULE INDEX
E-701 ELECTRICAL PANEL SCHEDULES
E-702 ELECTRICAL PANEL SCHEDULES
E-703 ELECTRICAL PANEL SCHEDULES
E-704 ELECTRICAL PANEL SCHEDULES
E-705 ELECTRICAL PANEL SCHEDULES
E-706 ELECTRICAL PANEL SCHEDULES
E-707 ELECTRICAL PANEL SCHEDULES
E-708 ELECTRICAL PANEL SCHEDULES
E-709 ELECTRICAL PANEL SCHEDULES
E-710 ELECTRICAL PANEL SCHEDULES
E-711 ELECTRICAL PANEL SCHEDULES
E-712 ELECTRICAL PANEL SCHEDULES
E-713 ELECTRICAL PANEL SCHEDULES
E-714 ELECTRICAL PANEL SCHEDULES
NUMBER DRAWING NAME
GENERAL
G-031 COVER SHEET - VOLUME THREE
G-032 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-033 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
NUMBER DRAWING NAME
GENERAL
G-041 COVER SHEET - VOLUME FOUR
G-042 INDEX OF DRAWINGS - VOLUME ONE AND TWO
G-043 INDEX OF DRAWINGS - VOLUME THREE AND FOUR
PUMP
ROOM
B302
MECHANICAL
ROOM
B300
MECHANICAL
ROOM
B301
MECHANICAL
ROOM
B301A
MECHANICAL
ROOM
B305
CL S
CL N
MECHANICAL
XB301
UTILITY TUNNEL
XB300
STAIR B
XB3-102
UNEXCAVATED
AREA
UTILITY TUNNEL
UNEXCAVATED
AREA
UNEXCAVATED
NO PLANNED ABATEMENT OF PLASTER ON B3
REFER TO GENERAL NOTES FOR HAZARDOUS
MATERIAL SCOPE
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-101
L E
V E
L B
H
A Z
M A
T P
L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL B3 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
DEPT.
STORAGE
B212
DEPT.
STORAGE
B213
MECHANICAL
ROOM
B218
DEPT.
STORAGE
B211
ELECTRICAL
ROOM
B210
WOMEN'S
TOILET
B204
CLASSROOM
B203
CLASSROOM
B202
CLASSROOM
B201
CLASSROOM
B200
MEN'S
TOILET
B205
JANITOR'S
CLOSET
B206CL S
CL N
CENTRAL STAIR
/ ENTRANCE
B201
CORRIDOR
B2100A
STAIR B
XB2-102
STAIR A
XB-201
UNEXCAVATED
SOCIAL
SCIENCE
SOCIAL
SCIENCE
ENGLISH
BOUNDARY OF CENTRAL STAIR
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
KEYNOTES #
1. PLASTER THAT IS INSTALLED DIRECTLY ONTO MASONRY ON THE INTERIOR FACE OF THE
EXTERIOR WALL IS SCHEDULED TO REMAIN IN PLACE AND BE ENCAPSULATED BY SPRAY
FOAM INSULATION (OR IN SOME LOCATION BY A FURRED PARTITION). CONTRACTOR
MUST IMPLEMENT APPROPRIATE WORKER PROTECTIONS AND ENVIRONMENTAL
CONTROLS FOR ANY AND ALL ACTIVITIES THAT IMPACT THE EXTERIOR WALL, INCLUDING
BUT NOT LIMITED TO INSTALLING UNDERLAYMENT FOR SPRAY FOAM INSULATION.
2. PLASTER ON THE INTERIOR CORRIDOR WALLS TO BE ABATED FROM BOTH SIDES OF THE
WALL, IN ACCORDANCE WITH OSHA AND EPA REGULATIONS.
3. CEILING PLASTER TO BE ABATED AT AREAS WITH EXPOSED CEILINGS. PLASTER ABOVE
NEW GWB OR ACP CEILINGS THAT EXTENDS ROOM WALL TO ROOM WALL CAN REMAIN
IF ABATEMENT PRECAUTIONS AS INDICATED IN THE GENERAL NOTES ARE TAKEN
DURING CONSTRUCTION. CEILING PLASTER IS REQURED TO BE ABATED WHERE
PARTITIONS ATTACH TO BUILDING STRUCTURE.
4. PLASTER ON WALLS AND DIRECTLY UNDER THE STAIR AND STAIR LANDINGS IN CENTRAL
STAIR TO REMAIN.
5. PLASTER TO REMAIN AT END OF CORRIDOR AND ARCHWAY IN CORRIDOR.
6. CEILING PLASTER IN THE CENTRAL STAIR TO REMAIN UNLESS SMALLER AREAS ARE
REQUIRED TO BE REMOVED FOR INFRASTRUCTURE PLACEMENT. REMOVAL OF PLASTER
MUST FOLLOW PRECAUTIONS DESCRIBED IN GENERAL NOTES THIS SHEET.
7. THE HAZMAT REPORT (2018) INDICATES THAT MOLD WAS IDENTIFIED IN THIS AREA.
REMEDIATE MOLD IN THIS AREA IN ACCORDANCE WITH SPECIFICATION SECTION 02 85 00
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-102
L E
V E
L B
H
A Z
M A
T P
L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL B2 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A
DN
OFFICE
B119
INSTRUCTOR
OFFICE
B118
OFFICE
B120
OFFICE
B117
STORAGE
CLOSET
B116
OFFICE
B115
MEN'S
TOILET
B114
JANITOR'S
CLOSET
B113
WOMEN'S
TOILET
B112
OFFICE
B121
OFFICE
B122
OFFICE
B123
OFFICE
B124
OFFICE
B125
OFFICE
B111
LECTURE
HALL
B101
LECTURE
HALL
B102FACULTY
LOUNGE
B100
OFFICE
B106
OFFICE
B107
OFFICE
B108
OFFICE
B109
OFFICE
B109A
OFFICE
B110
OFFICE
B111A
OFFICE
SUITE
B103
OFFICE
B104
CL S
CL N
STAIR B
XB1-102
CENTRAL STAIR
B101
STAIR A
XB1-101
CORRIDOR
B100B
CORRIDOR
B1100A
STUDENT 4
BOUNDARY OF CENTRAL STAIR
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
KEYNOTES #
1. PLASTER THAT IS INSTALLED DIRECTLY ONTO MASONRY ON THE INTERIOR FACE OF THE
EXTERIOR WALL IS SCHEDULED TO REMAIN IN PLACE AND BE ENCAPSULATED BY SPRAY
FOAM INSULATION (OR IN SOME LOCATION BY A FURRED PARTITION). CONTRACTOR
MUST IMPLEMENT APPROPRIATE WORKER PROTECTIONS AND ENVIRONMENTAL
CONTROLS FOR ANY AND ALL ACTIVITIES THAT IMPACT THE EXTERIOR WALL, INCLUDING
BUT NOT LIMITED TO INSTALLING UNDERLAYMENT FOR SPRAY FOAM INSULATION.
2. PLASTER ON THE INTERIOR CORRIDOR WALLS TO BE ABATED FROM BOTH SIDES OF THE
WALL, IN ACCORDANCE WITH OSHA AND EPA REGULATIONS.
3. CEILING PLASTER TO BE ABATED AT AREAS WITH EXPOSED CEILINGS. PLASTER ABOVE
NEW GWB OR ACP CEILINGS THAT EXTENDS ROOM WALL TO ROOM WALL CAN REMAIN
IF ABATEMENT PRECAUTIONS AS INDICATED IN THE GENERAL NOTES ARE TAKEN
DURING CONSTRUCTION. CEILING PLASTER IS REQURED TO BE ABATED WHERE
PARTITIONS ATTACH TO BUILDING STRUCTURE.
4. PLASTER ON WALLS AND DIRECTLY UNDER THE STAIR AND STAIR LANDINGS IN CENTRAL
STAIR TO REMAIN.
5. PLASTER TO REMAIN AT END OF CORRIDOR AND ARCHWAY IN CORRIDOR.
6. CEILING PLASTER IN THE CENTRAL STAIR TO REMAIN UNLESS SMALLER AREAS ARE
REQUIRED TO BE REMOVED FOR INFRASTRUCTURE PLACEMENT. REMOVAL OF PLASTER
MUST FOLLOW PRECAUTIONS DESCRIBED IN GENERAL NOTES THIS SHEET.
7. THE HAZMAT REPORT (2018) INDICATES THAT MOLD WAS IDENTIFIED IN THIS AREA.
REMEDIATE MOLD IN THIS AREA IN ACCORDANCE WITH SPECIFICATION SECTION 02 85 00
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-103
L E
V E
L B
H
A Z
M A
T P
L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL B1 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A
CONFERENCE
ROOM
DEBATE
ROOM
OFFICE
OFFICE
OFFICE
RECEPTION
OFFICE
SECRETARIES
OFFICE
OFFICE
BREAK
ROOM
COPY
ROOM
107A
OFFICE
CONFERENCE
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
122A
OFFICE
OFFICE
STORAGE
CLOSET
OFFICE
MEN'S
TOILET
JANITOR'S
CLOSET
WOMEN'S
TOILET
CL S
CL N
CENTRAL
STAIR/ENTRY
STAIR A
X1-101
STAIR B
X1-102
CORRIDOR
100A
CORRIDOR
100B
CORRIDOR
100C
BOUNDARY OF CENTRAL STAIR
2 2
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
KEYNOTES #
1. PLASTER THAT IS INSTALLED DIRECTLY ONTO MASONRY ON THE INTERIOR FACE OF THE
EXTERIOR WALL IS SCHEDULED TO REMAIN IN PLACE AND BE ENCAPSULATED BY SPRAY
FOAM INSULATION (OR IN SOME LOCATION BY A FURRED PARTITION). CONTRACTOR
MUST IMPLEMENT APPROPRIATE WORKER PROTECTIONS AND ENVIRONMENTAL
CONTROLS FOR ANY AND ALL ACTIVITIES THAT IMPACT THE EXTERIOR WALL, INCLUDING
BUT NOT LIMITED TO INSTALLING UNDERLAYMENT FOR SPRAY FOAM INSULATION.
2. PLASTER ON THE INTERIOR CORRIDOR WALLS TO BE ABATED FROM BOTH SIDES OF THE
WALL, IN ACCORDANCE WITH OSHA AND EPA REGULATIONS.
3. CEILING PLASTER TO BE ABATED AT AREAS WITH EXPOSED CEILINGS. PLASTER ABOVE
NEW GWB OR ACP CEILINGS THAT EXTENDS ROOM WALL TO ROOM WALL CAN REMAIN
IF ABATEMENT PRECAUTIONS AS INDICATED IN THE GENERAL NOTES ARE TAKEN
DURING CONSTRUCTION. CEILING PLASTER IS REQURED TO BE ABATED WHERE
PARTITIONS ATTACH TO BUILDING STRUCTURE.
4. PLASTER ON WALLS AND DIRECTLY UNDER THE STAIR AND STAIR LANDINGS IN CENTRAL
STAIR TO REMAIN.
5. PLASTER TO REMAIN AT END OF CORRIDOR AND ARCHWAY IN CORRIDOR.
6. CEILING PLASTER IN THE CENTRAL STAIR TO REMAIN UNLESS SMALLER AREAS ARE
REQUIRED TO BE REMOVED FOR INFRASTRUCTURE PLACEMENT. REMOVAL OF PLASTER
MUST FOLLOW PRECAUTIONS DESCRIBED IN GENERAL NOTES THIS SHEET.
7. THE HAZMAT REPORT (2018) INDICATES THAT MOLD WAS IDENTIFIED IN THIS AREA.
REMEDIATE MOLD IN THIS AREA IN ACCORDANCE WITH SPECIFICATION SECTION 02 85 00
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-104
L E
V E
L
H A
Z M
A T
P L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL 1 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
COPY
ROOM
204A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE
ROOM
MEN'S
TOILET
JANITOR'S
CLOSET
WOMEN'S
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CL S
CL N
STAIR B
X2-102
STAIR A
X2-101
CORRIDOR
200A
CENTRAL STAIR
CORRIDOR
200B
BOUNDARY OF CENTRAL STAIR
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
KEYNOTES #
1. PLASTER THAT IS INSTALLED DIRECTLY ONTO MASONRY ON THE INTERIOR FACE OF THE
EXTERIOR WALL IS SCHEDULED TO REMAIN IN PLACE AND BE ENCAPSULATED BY SPRAY
FOAM INSULATION (OR IN SOME LOCATION BY A FURRED PARTITION). CONTRACTOR
MUST IMPLEMENT APPROPRIATE WORKER PROTECTIONS AND ENVIRONMENTAL
CONTROLS FOR ANY AND ALL ACTIVITIES THAT IMPACT THE EXTERIOR WALL, INCLUDING
BUT NOT LIMITED TO INSTALLING UNDERLAYMENT FOR SPRAY FOAM INSULATION.
2. PLASTER ON THE INTERIOR CORRIDOR WALLS TO BE ABATED FROM BOTH SIDES OF THE
WALL, IN ACCORDANCE WITH OSHA AND EPA REGULATIONS.
3. CEILING PLASTER TO BE ABATED AT AREAS WITH EXPOSED CEILINGS. PLASTER ABOVE
NEW GWB OR ACP CEILINGS THAT EXTENDS ROOM WALL TO ROOM WALL CAN REMAIN
IF ABATEMENT PRECAUTIONS AS INDICATED IN THE GENERAL NOTES ARE TAKEN
DURING CONSTRUCTION. CEILING PLASTER IS REQURED TO BE ABATED WHERE
PARTITIONS ATTACH TO BUILDING STRUCTURE.
4. PLASTER ON WALLS AND DIRECTLY UNDER THE STAIR AND STAIR LANDINGS IN CENTRAL
STAIR TO REMAIN.
5. PLASTER TO REMAIN AT END OF CORRIDOR AND ARCHWAY IN CORRIDOR.
6. CEILING PLASTER IN THE CENTRAL STAIR TO REMAIN UNLESS SMALLER AREAS ARE
REQUIRED TO BE REMOVED FOR INFRASTRUCTURE PLACEMENT. REMOVAL OF PLASTER
MUST FOLLOW PRECAUTIONS DESCRIBED IN GENERAL NOTES THIS SHEET.
7. THE HAZMAT REPORT (2018) INDICATES THAT MOLD WAS IDENTIFIED IN THIS AREA.
REMEDIATE MOLD IN THIS AREA IN ACCORDANCE WITH SPECIFICATION SECTION 02 85 00
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-105
L E
V E
L
H A
Z M
A T
P L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL 2 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A
MEN'S
TOILET
JANITOR'S
CLOSET
WOMEN'S
TOILET
OFFICE
COPY
ROOM
OFFICE
OFFICE
OFFICE
323A
OFFICE
CONFERENCE
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
310A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
BREAK
ROOM
OFFICE
OFFICE
CL S
CL N
BOUNDARY OF CENTRAL STAIR
2 2
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
KEYNOTES #
1. PLASTER THAT IS INSTALLED DIRECTLY ONTO MASONRY ON THE INTERIOR FACE OF THE
EXTERIOR WALL IS SCHEDULED TO REMAIN IN PLACE AND BE ENCAPSULATED BY SPRAY
FOAM INSULATION (OR IN SOME LOCATION BY A FURRED PARTITION). CONTRACTOR
MUST IMPLEMENT APPROPRIATE WORKER PROTECTIONS AND ENVIRONMENTAL
CONTROLS FOR ANY AND ALL ACTIVITIES THAT IMPACT THE EXTERIOR WALL, INCLUDING
BUT NOT LIMITED TO INSTALLING UNDERLAYMENT FOR SPRAY FOAM INSULATION.
2. PLASTER ON THE INTERIOR CORRIDOR WALLS TO BE ABATED FROM BOTH SIDES OF THE
WALL, IN ACCORDANCE WITH OSHA AND EPA REGULATIONS.
3. CEILING PLASTER TO BE ABATED AT AREAS WITH EXPOSED CEILINGS. PLASTER ABOVE
NEW GWB OR ACP CEILINGS THAT EXTENDS ROOM WALL TO ROOM WALL CAN REMAIN
IF ABATEMENT PRECAUTIONS AS INDICATED IN THE GENERAL NOTES ARE TAKEN
DURING CONSTRUCTION. CEILING PLASTER IS REQURED TO BE ABATED WHERE
PARTITIONS ATTACH TO BUILDING STRUCTURE.
4. PLASTER ON WALLS AND DIRECTLY UNDER THE STAIR AND STAIR LANDINGS IN CENTRAL
STAIR TO REMAIN.
5. PLASTER TO REMAIN AT END OF CORRIDOR AND ARCHWAY IN CORRIDOR.
6. CEILING PLASTER IN THE CENTRAL STAIR TO REMAIN UNLESS SMALLER AREAS ARE
REQUIRED TO BE REMOVED FOR INFRASTRUCTURE PLACEMENT. REMOVAL OF PLASTER
MUST FOLLOW PRECAUTIONS DESCRIBED IN GENERAL NOTES THIS SHEET.
7. THE HAZMAT REPORT (2018) INDICATES THAT MOLD WAS IDENTIFIED IN THIS AREA.
REMEDIATE MOLD IN THIS AREA IN ACCORDANCE WITH SPECIFICATION SECTION 02 85 00
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-106
L E
V E
L
H A
Z M
A T
P L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL 3 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A
MEN'S
TOILET
JANITOR'S
CLOSET
WOMEN'S
TOILET
OFFICE
FAULKNER
LIBRARY
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CL S
CL N
WILLIAM
FOR SOUTH WING
ROOF -REFER TO
AD108 FOR
INFORMATION ON
ROOF SYSTEMS
BOUNDARY OF CENTRAL STAIR
GENERAL NOTES
1. WARNING! PLASTER CONTAINS ASBESTOS. WORKER PROTECTIONS AND
ENVIRONMENTAL CONTROLS MUST BE IN PLACE PRIOR TO PERFORMING ANY WORK THAT
WILL IMPACT SUSPECT ASBESTOS CONTAINING MATERIALS (ACM)
2. THE CONTRACTOR MAY, AT HIS EXPENSE, PERFORM TESTING TO EXCLUDE MATERIALS
FROM CONSIDERATION AS ACM
3. ANY SUSPICIOUS MATERIAL SHOULD BE ASSUMED TO BE ACM UNTIL IT IS TESTED
4. ANY MATERIAL LISTED IN THE HAZMAT REPORT AS ACM, AND THAT IS SCHEDULED FOR
DEMOLITION AS ACM MUST BE REMEDIATED IN ACCORDANCE WITH APPLICABLE FEDERAL
AND STATE REGULATIONS
5. LEAD BASED PAINT PRESENT IN AREAS INDICATED IN HAZMAT REPORT. WORKER
PROTECTION IS REQUIRED.
6. MOLD WAS FOUND TO BE PRESENT IN LATEST HAZMAT REPORT (2018) AS INCLUDED IN
SPECIFICATIONS. CONTRACTOR MUST PERFORM VISUAL INSPECTION TO DETERMINE IF
ADDITIONAL MOLD IS PRESENT, AND REMEDIATE ANY INSTANCES OF MOLD IDENTIFIED.
CORRECTIVE ACTIONS MUST MITIGATE WATER INTRUSION OR SOURCE OF MOISTURE IN
MOLD-AFFECTED AREAS PRIOR TO RECONSTRUCTION.
7. PLASTER CEILING ABATEMENT IN THE CENTRAL STAIR ON THE FIRST FLOOR WILL BE
ABOVE COFFERED CEILING ELEMENTS TO REMAIN. WITH ABATEMENT ENSURE THAT
EXISTING ELEMENTS TO REMAIN ARE NOT DAMAGED OR REMOVED.
KEYNOTES #
1. PLASTER THAT IS INSTALLED DIRECTLY ONTO MASONRY ON THE INTERIOR FACE OF THE
EXTERIOR WALL IS SCHEDULED TO REMAIN IN PLACE AND BE ENCAPSULATED BY SPRAY
FOAM INSULATION (OR IN SOME LOCATION BY A FURRED PARTITION). CONTRACTOR
MUST IMPLEMENT APPROPRIATE WORKER PROTECTIONS AND ENVIRONMENTAL
CONTROLS FOR ANY AND ALL ACTIVITIES THAT IMPACT THE EXTERIOR WALL, INCLUDING
BUT NOT LIMITED TO INSTALLING UNDERLAYMENT FOR SPRAY FOAM INSULATION.
2. PLASTER ON THE INTERIOR CORRIDOR WALLS TO BE ABATED FROM BOTH SIDES OF THE
WALL, IN ACCORDANCE WITH OSHA AND EPA REGULATIONS.
3. CEILING PLASTER TO BE ABATED AT AREAS WITH EXPOSED CEILINGS. PLASTER ABOVE
NEW GWB OR ACP CEILINGS THAT EXTENDS ROOM WALL TO ROOM WALL CAN REMAIN
IF ABATEMENT PRECAUTIONS AS INDICATED IN THE GENERAL NOTES ARE TAKEN
DURING CONSTRUCTION. CEILING PLASTER IS REQURED TO BE ABATED WHERE
PARTITIONS ATTACH TO BUILDING STRUCTURE.
4. PLASTER ON WALLS AND DIRECTLY UNDER THE STAIR AND STAIR LANDINGS IN CENTRAL
STAIR TO REMAIN.
5. PLASTER TO REMAIN AT END OF CORRIDOR AND ARCHWAY IN CORRIDOR.
6. CEILING PLASTER IN THE CENTRAL STAIR TO REMAIN UNLESS SMALLER AREAS ARE
REQUIRED TO BE REMOVED FOR INFRASTRUCTURE PLACEMENT. REMOVAL OF PLASTER
MUST FOLLOW PRECAUTIONS DESCRIBED IN GENERAL NOTES THIS SHEET.
7. THE HAZMAT REPORT (2018) INDICATES THAT MOLD WAS IDENTIFIED IN THIS AREA.
REMEDIATE MOLD IN THIS AREA IN ACCORDANCE WITH SPECIFICATION SECTION 02 85 00
LEGEND
CEILING PLASTER TO BE ABATED - REFER TO KEYNOTE 3
PLASTER TO BE ABATED AT CORRIDOR WALLS - REFER TO KEYNOTE 2
PLASTER TO REMAIN AT EXTERIOR/INTERIOR WALLS - REFER TO KEYNOTE 1
CEILING PLASTER TO REMAIN - REFER TO KEYNOTE 6
MOLD TO BE REMEDIATED - REFER TO KEYNOTE 7
HAZMAT DRAWINGS ARE INCLUDED FOR BIDDING PURPOSES AND TO
CONVEY DESIGN INTENT. HAZMAT ABATEMENT TO BE PERFORMED IN
ACCORDANCE WITH HAZMAT SPECIFICATIONS
N
8'4' 16'0
SCALE: 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
H-107
L E
V E
L
H A
Z M
A T
P L A
N
B U
IL
D
IN
G
S
/6
R
E N
O V
A T
IO
N
L
IN
C O
L N
H A
L L
L
IN
C O
L N
H A
L L
W E
S T
P O
IN
T
N
E W
Y O
R K
A F
L O
R A
A F
L O
R A
D S
T E
L T
Z E
R
M
A R
C H
W D
S -1
-R
-0
W D
S -1
-C
-0 -L
REVISED RTA SUBMISSION 03/01/2023
1/8" = 1'-0" C1
LEVEL 4 HAZMAT PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A
M
M c K
E E
V E
R
D
P
A T
E L
J
K
U R
N A
T H
G E
N E
R A
L
N
O T
E S
C I V
I L
C-001
D A
T E
M A
R K
D E
S C
R I P
T I O
N
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
I S
S U
E
D
A T
E
C O
N T
R A
C
N
O
S O
L I C
I T
A T
I O
N
N
O
F I L
U M
B E
R
SHEET ID
F I
A M
E
U S
A
R M
Y
C
O R
S
F
E
N G
I N
E E
R S
US Army Corps of Engineers
L I N
C O
H
L L
W E
I N
T
N
W
Y
R
K
W D
S C
L
M
A R
A N
S I
D
W D
S R
B U
I L D
I N
G
R
E N
O V
A T
I O
N
L I N
C O
REVISED RTA SUBMISSION 3/1/2023
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
CIVIL/SITE CONSTRUCTION GENERAL NOTES:
1. THESE PLANS REFERENCE LOCATION AND TOPOGRAPHIC SURVEY PREPARED BY:
NAME: MJ ENGINEERING AND LAND SURVEYING, P.C.
1533 CRESCENT ROAD
CLIFTON PARK, NY 12065
PHONE: (518) 371-0799
DATED: 01/16/2020
HORIZONTAL DATUM: NORTH AMERICAN DATUM 1983 (NAD83) PROJECTED ON THE NEW YORK STATE PLANE COORDINATE SYSTEM (EAST ZONE)
VERTICAL DATUM: NORTH AMERICAN VERTICAL DATUM 1988 (NAVD 88)
REFERENCE CONTROL POINT IS CONTINUOUSLY OPERATING REFERENCE STATION (CORS) NEWBURGH CORS ARP (NYNB)
2. PROVIDE IMPROVEMENTS IN ACCORDANCE WITH THE UNIFIED FACILITIES GUIDE SPECIFICATIONS AND AS SPECIFIED IN THE CONTRACT DOCUMENTS, DRAWINGS, AND APPENDICES.
3. PRIOR TO ANY CONSTRUCTION, PROVIDE A PHASING PLAN INCLUSIVE OF A WRITTEN SEQUENCE OF CONSTRUCTION AND PLANS SHOWING PHASED WORK AREAS, STOCKPILE AREAS, WORKER PARKING AREAS, TRAILER LOCATION, MATERIAL STORAGE AREAS, MAINTAINED SITE ENTRANCE LOCATION, PORTABLE SANITARY STATIONS, HAUL ROUTES AND ALL OTHER
NECESSARY CONTRACTOR CONSTRUCTION AREAS. ALL MATERIAL STORAGE AND CONTRACTOR OPERATIONS MUST BE LOCATED WITHIN THE LIMIT OF DISTURBANCE IDENTIFIED ON THE
PLANS. SUBMIT PHASING PLAN TO THE CONTRACTING OFFICER FOR REVIEW AND APPROVAL. CONTRACTOR MUST FOLLOW THE HAUL ROUTE AS DEPICTED ON SHEET CS102 "TRUCK
ACCESS PLAN".
4. PROVIDE PROPER AND SUFFICIENT CONSTRUCTION PROTECTION TO THE WORKERS AND ALL PERSONNEL ONSITE. OSHA EM 385-1-1, AND OTHER FEDERAL, STATE, AND LOCAL CODES
MUST BE FOLLOWED.
5. WORK AND MATERIAL MUST MEET THE REQUIREMENTS OF THE UNITED FACILITIES CRITERIA (UFC), LOCAL, STATE, AND FEDERAL LAWS, STATUTES, RULES, AND REGULATIONS.
6. PERFORM WORK IN A SAFE AND CAUTIOUS MANNER IN ACCORDANCE WITH EM 385-1-1.
7. QUANTITIES SHOWN HEREIN ARE APPROXIMATE AND FOR GENERAL INFORMATION ONLY. VERIFY ALL QUANTITIES AND PROVIDE SUPERINTENDENCE, MATERIAL, LABOR, SURVEYING, AND
COORDINATION NECESSARY TO CONSTRUCT THE PROJECT COMPLETE AND AS GENERALLY INTENDED IN THE CONTRACT DOCUMENTS. CONTRACTOR MUST PROVIDE COORDINATION WITH
CONTRACTING OFFICER, USMA AUTHORITIES, AND UTILITIES FOR ALL INTERFACING REQUIRED BY THE PROJECT.
8. AT NO COST TO THE GOVERNMENT, DISTURBED AREAS MUST BE RESTORED AS INDICATED ON THE CONTRACT DRAWINGS AND COMPLY WITH THE CONTRACT SPECIFICATIONS.
9. IMPLEMENT AND MAINTAIN ALL SOIL EROSION CONTROL STRUCTURES AND MEASURES THROUGHOUT CONSTRUCTION. FOLLOW NYSDEC SOIL EROSION AND SEDIMENT
CONTROL REQUIREMENTS. MODIFICATIONS TO THE SEQUENCE OF CONSTRUCTION MUST BE SUBMITTED TO THE CONTRACTING OFFICER FOR REVIEW AND PROCESSING FOR
APPROVAL. MODIFICATIONS WILL INCUR ADDITIONAL REVIEW PERIODS AS REQUIRED TO PROCESS APPROVALS. REFERENCE SPECIFICATION SECTIONS AND SOIL EROSION NOTES.
10. IN CASE OF DISCREPANCIES BETWEEN THESE PLANS AND THE PROJECT SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT MUST APPLY.
11. SUBMISSIONS REQUIRED FOR DOCUMENTATION OF CONFORMANCE TO THE CONTRACT PLANS, DOCUMENTS, AND SPECIFICATIONS MUST BE PROVIDED TO THE
CONTRACTING OFFICER FOR DISTRIBUTION TO THE APPROPRIATE REVIEWER.
12. INGRESS AND EGRESS TO AND FROM THE CONSTRUCTION SITE MUST BE KEPT READILY ACCESSIBLE AND UNOBSTRUCTED AT ALL TIMES. CONSTRUCTION EQUIPMENT MUST NOT
OBSTRUCT ROADWAYS AND/OR PASSAGEWAYS UNLESS PRE-APPROVAL IS REQUESTED AND APPROVED FROM THE COR 14 DAYS PRIOR TO NEED (FOR ITS SUBMISSION TO USMA AN DPW).
NO PARKING OR STOPPING ALONG INGRESS-EGRESS ROUTE MUST BE PERMITTED.
13. MAINTAIN THE CONSTRUCTION SITE AND THE AREAS OF WORK DAILY WHILE PERFORMING THIS CONTRACT. CONSTRUCTION DEBRIS MUST BE REMOVED FROM THE CONSTRUCTION SITE
ON A DAILY BASIS. NO BURNING OF DEBRIS OR USE OF EXPLOSIVES MUST BE PERMITTED.
14. PREPARE, LAYOUT, AND INSTALL WORK IN SUCH A MANNER AS NOT TO DELAY OR INTERFERE WITH THE PROGRESS OF OTHER INSTALLATION CONTRACT WORK AND/OR ANY
WORK DESIGNATED TO BE PERFORMED UNDER ANY OTHER CONTRACT ON THE INSTALLATION AND/OR ANY OTHER WORK IN PROGRESS ON THE INSTALLATION.
15. THE CONTRACTOR MUST PROVIDE ALL TESTING SERVICES AND SUBMIT, TO THE CONTRACTING OFFICER FOR REVIEW AND APPROVAL, A LIST OF ALL TESTS TO BE PERFORMED BY EACH
TESTING SERVICE.
16. QUALITY CONTROL INSPECTION AND TESTING MUST BE MADE BY A USACE-APPROVED LABORATORY UNDER CONTRACT TO THE CONTRACTOR. COPIES OF REPORTS AND TESTING
RESULTS ASSOCIATED WITH THE CONTRACTOR'S QUALITY CONTROL PROGRAM MUST BE SUBMITTED TO THE CONTRACTING OFFICER.
17. ILLUMINATE AND PROTECT ALL ELEMENTS COMPLETED OR PARTIALLY COMPLETED AND ALSO APPLY THE SAME TO EXCAVATED TRENCHES AND OPENINGS DURING PERIODS OF LOW
LIGHT TO PROTECT AGAINST INJURY TO WORKERS, PEDESTRIANS, WILDLIFE, ETC. CONSTRUCTION LIGHTING MUST BE KEPT TO A MINIMUM ALL DAY AND ALL NIGHT.
18. DO NOT SCALE DRAWINGS. DETAILS, NOTES, AND THE LIKE ARE TYPICAL AND APPLY IN GENERAL TO SIMILAR CONDITIONS.
19. BY SUBMITTING A PROPOSAL OR AGREEMENT TO PERFORM WORK, THE CONTRACTOR AGREES THAT THEY ARE SKILLED AND EXPERIENCED IN THE USE AND INTERPRETATION
OF PLANS AND SPECIFICATIONS, THEY HAVE CAREFULLY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .