This document is an LBP (Lead-Based Paint) Testing Data Sheet for a Shoppette facility located in Building 9464. The testing was conducted on 5/14/2025 using a Viken/Pb200e XRF (X-ray fluorescence) instrument with serial number 2759, operated by inspectors Frank Lujan and Paul Rodriguez. The data sheet shows three test locations on metal fascia (east, north, and south), all of which tested negative for lead-based paint with readings of 0.1, 0.0, and 0.0 mg/cm² respectively. The testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm² by X-ray fluorescence, with calibration readings confirming the instrument's accuracy.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LBP TESTING DATA SHEET

Facility Information: Shoppette Facility Name: Building Number: 9464 XRF Model and M/N:

Viken/Pb200e Date of Assessment: 5/14/2025

XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez

Data Sheet

SA

M

PL

E

ID

SU

BS

TR

AT

E

CO

M

P0 N

EN

T

CO

LO

R O

F

CO

M

PO

N

EN

T

TE

ST

L O

CA

TI

O N

DE

SC

RI

PT

IO

XR

F

RE

AD

IN

G

(m g/ cm ²)

CL

AS

SI

FI

CA

TI

CO

DI

TI

N/A N/A N/A Calibration (< 0.00) 0 ACCEPTABLE N/A N/A N/A N/A Calibration (0.8 to 1.2) 1.0 ACCEPTABLE N/A LBP-01 Metal Fascia Brown East .1 NEGATIVE INTACT LBP-02 Metal Fascia Brown North .0 NEGATIVE INTACT LBP-03 Metal Fascia Brown South .0 NEGATIVE INTACT

NOTES:

DPW-ED conforms to Texas Department of State Health Services lead measurement standard, 1.0mg/cm2 by X-ray fluorescence.

File details come from the government source that posted it. Updated .