This is a technical drawing and site plan markup document prepared by the City of Orlando Water Reclamation Division for the Lakeside Drive Over Lake Rowena/Lake Sue Pipe Culvert Repair project in Orange County, Florida. The document, marked up on July 30, 2024 by Rudy Mulamba, E.I., depicts the existing infrastructure conditions and utility locations for a pipe culvert repair project involving a 120-inch diameter corrugated metal pipe (CMP) culvert beneath Lakeside Drive. The site plan identifies the project location adjacent to Lakes Rowena and Sue, with contractor staging area designated at Beeman Park, and access to the project site restricted to waterway access via barge only with no roadway closures permitted. The technical drawings include detailed elevation data, invert measurements for existing pipes (including 18-inch and 12-inch reinforced concrete pipe and 12-inch vitrified clay pipe), riprap revetment specifications, existing wall locations, and utility markings using standardized color codes: red for utilities to be removed or relocated, green for utilities to remain in place, and brown for new utilities. A 3-inch PVC sewer force main operated by the City of Orlando is identified as an existing utility to remain in place.
The markup document serves as a reference drawing for design and bidding purposes and explicitly disclaims that all information, including utility locations, invert elevations, pipe materials, and sizing, requires field verification and cannot be used for construction planning without on-site confirmation. The document specifies that contractor staging plans must be submitted to the County for approval and notes that vessel traffic through the canal system must be maintained throughout the construction period. The project carries an estimated cost of $628,577.09, with sealed bids due electronically through the OpenGov e-Procurement Platform by 4:00 p.m. EST on Thursday, March 26, 2026, and a non-mandatory pre-bid meeting scheduled for March 5, 2026 at 1:30 p.m. Contractors must achieve substantial completion within 150 consecutive calendar days and final completion within 180 consecutive calendar days from the Notice to Proceed, with liquidated damages of $500 per day for delays beyond the final completion deadline.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
FLORIDA
GOVERNMENT
ORANGE COUNTY
SHEET NO.
REF. DWG. NO.SHEET TITLE:
PROJECT NAME:
BRIDGE NO. ???????
ORLANDO, FL. 32817
11723 ORPINGTON ST. SUITE 100
SINGHOFEN HALFF
P.E. LICENSE NUMBER 51373
ROBERT GAYLORD, P.E.
PIPE CULVERT REPAIR
LAKESIDE DRIVE OVER LAKE ROWENA/LAKE SUE
N
AND SITE ACCESS LOCATION
CONTRACTOR STAGING AREA
BEEMAN PARK
SHALL SUBMIT STAGING PLAN TO COUNTY FOR APPROVAL.
CONTRACTOR STAGING AREA SHALL BE AT BEEMAN PARK. CONTRACTOR 3.
ACCESS TO PROJECT SITE SHALL BE VIA BARGE.2.
NO ROADWAY CLOSURES WILL BE ALLOWED.1.
NOTES:
LAKESIDE DR
L A
K E
S
H O
R E
D
LAKESIDE DR
SUE AVE
ROWENA AVE
B U
M B
Y
S
T
LEU RD
W O
O D
L A
W N
RIDGE AVE
WOODSIDE AVE
L A
K E
S
U
LAKE SUE
LAKE ROWENA
PROJECT SITE
SITE PLAN
zur32601 Text Box *The information depicted in this PDF markup, including utility locations, invert elevations, pipe material, pipe sizing, and service lateral locations, contain third party information for reference purposes only. Field verification is required for exact locations, inverts, materials, sizing, lengths, and rim elevations. The information included in this markup shall not be used by the recipient for preparation of construction plans or otherwise used for construction without field verification of the information.
Mul35963 Text Box Plans to be marked up using the following color codes:
RED: Existing Utilities that are to be:
(a) To be removed or relocated horizontally or
(b) To be placed out-of-service (deactivated) but left in place.
GREEN: Existing Utilities to remain in place with no adjustment.
BROWN: New Utilities zur32601 Text Box Mark-Up City of Orlando Water Reclamation Division by: Rudy Mulamba, E.I.
7/30/2024
.5
.3
.6
.1
.8
.7
.2
.4
.2
.0
.1
.7
.9
.5
.7
.3
.0
.6
.6
.2
74.07
74.17 .9
74.98 .9
.9
.1
.2
.1
.3
.3 573.24
.3
.1
.0
.9
74.99
.8
.0
.8
7 7 .1
75.65 .5
.6
75.48
72.38
.7
.3
.9
.4
72.57
70.49 .9
70.09 .5 1 74.96
.7
.7
.0
74.67
.8
70.33
69.47
.2
74.11
.4
73.51
.4
.3
.3 3 74.09
.5
.6
77.91
.9
.6
.5
.0
75.94
75.73
75.7675.83
75.88
.6
.2
.4
74.43
74.40
.1
.7
73.33
73.15
.9
73.20
73.3373.21
73.20
.2
.2
.9
.3
.4
74.53
74.43
78.57
.5
78.60
.6
.5
.3
.5
.4
.1
.7
74.70
74.71
.2
.0
.8
.3
.8
.8
.9
.1
.3
.5
.9
.4
.5
.0
.8
.7
.1
.6
.5
.1
.5
.8
.3
.0
.1
W A
T E
R
78.93
78.93
79.14
79.09
.0
.2
.7
.6
.9
.7
.7
.9
.5
.7
.9
.5
.7
.9
.5
I N
V E
R T
.6
O B
V E
R T
.0
C
M P
I N
V E
R T
.7
O B
V E
R T
.0
C
M P
I N
V E
R T
.5
O B
V E
R T
.0
C
M P
H E
D G
E
H E
D G
E
H E
D G
E
A S
P H
A L T
P
A T
C H
I N
V E
R T
R
C P
W I T
H L
I N
E R
.2
I N
V E
R T
R
C P
W I T
H L
I N
E R
.8
I N
V E
R T
V
C P
.8
' IR
O N
F E
N C
E
' V
IN
Y
L F
E N
C E
R I P
R
A P
R I P
R
A P
' W
ID
E
M A
S O
N R
Y W
A L
L
R I P
R
A P
R I P
R
A P
C A
N A
L
W
T O
P O
F W
A T
E R
.8
E L
E V
A T
IO
N
.2
S E
A S
O N
A L
H
IG
H W
A T
E R
M A
R K
RIP RAP
W
E D
G E
O F
P A
V E
M E
N T
101+00
W
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
FLORIDA
GOVERNMENT
ORANGE COUNTY
SHEET NO.
REF. DWG. NO.SHEET TITLE:
PROJECT NAME:
BRIDGE NO. ???????
ORLANDO, FL. 32817
11723 ORPINGTON ST. SUITE 100
SINGHOFEN HALFF
P.E. LICENSE NUMBER 51373
ROBERT GAYLORD, P.E.
PIPE CULVERT REPAIR
LAKESIDE DRIVE OVER LAKE ROWENA/LAKE SUE
N
EXISTING 120" CMP
EXISTING GRADE
CONSTRUCTION BASELINE
L A
K E S
ID
E X I S
T I N
G
R C P
E X I S
T I N
G
R C P
E X I S
T I N
G
V C P
EX. WALL
EX. WALL
E X
W A
L L
EX. WALL
EX. WALL
PLAN & PROFILE
Mul35963 Line
Mul35963 Callout City of Orlando
3" PVC
Sewer Force Main (to remain) zur32601 Text Box *The information depicted in this PDF markup, including utility locations, invert elevations, pipe material, pipe sizing, and service lateral locations, contain third party information for reference purposes only. Field verification is required for exact locations, inverts, materials, sizing, lengths, and rim elevations. The information included in this markup shall not be used by the recipient for preparation of construction plans or otherwise used for construction without field verification of the information.
Mul35963 Text Box Plans to be marked up using the following color codes:
RED: Existing Utilities that are to be:
(a) To be removed or relocated horizontally or
(b) To be placed out-of-service (deactivated) but left in place.
GREEN: Existing Utilities to remain in place with no adjustment.
BROWN: New Utilities
| df-LD-Layout1-Default-000 |
| Untitled |
File details come from the government source that posted it. Updated .