LakesideDr_(City_of_Orlando_WRD_Mark-Up).pdf
PDF 593 KB Posted
- Solicitation number
- Y26-731
- Issued by
- Orange County, Orlando City, Florida
About this file
This is a project markup document and specification file prepared by Singhofen Halff for the City of Orlando Water Reclamation Division in collaboration with Orange County, Florida, for the Lakeside Drive Over Lake Rowena/Lake Sue Pipe Culvert Repair project. The project involves repair work on existing pipe culverts, including a 120-inch corrugated metal pipe (CMP) and associated smaller pipes (18-inch reinforced concrete pipe, 12-inch reinforced concrete pipe, and 12-inch vitrified clay pipe) located beneath Lakeside Drive spanning Lake Rowena and Lake Sue in Orlando, Florida. The document includes site plans, elevation profiles, utility markups, and construction specifications indicating that contractor staging will occur at Beeman Park with access to the project site via barge, and no roadway closures are permitted. The sealed bid submission deadline is 4:00 pm EST on Thursday, March 26, 2026, with questions due by Wednesday, March 11, 2026 at 5:00 pm EST. Electronic bid submissions are required through the OpenGov e-Procurement Platform.
The estimated project cost is $628,577.09. The markup document uses color-coded utility notations indicating existing utilities to be removed or relocated (red), existing utilities to remain in place (green), and new utilities (brown). Existing utilities identified include a 3-inch PVC sewer force main operated by the City of Orlando Water Reclamation Division that is to remain in service. Field verification is required for exact utility locations, invert elevations, pipe materials, sizing, lengths, and rim elevations prior to construction. The document explicitly prohibits use of the provided markup information for construction planning without independent field verification.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
FLORIDA
GOVERNMENT
ORANGE COUNTY
SHEET NO.
REF. DWG. NO.SHEET TITLE:
PROJECT NAME:
BRIDGE NO. ???????
ORLANDO, FL. 32817
11723 ORPINGTON ST. SUITE 100
SINGHOFEN HALFF
P.E. LICENSE NUMBER 51373
ROBERT GAYLORD, P.E.
PIPE CULVERT REPAIR
LAKESIDE DRIVE OVER LAKE ROWENA/LAKE SUE
N
AND SITE ACCESS LOCATION
CONTRACTOR STAGING AREA
BEEMAN PARK
SHALL SUBMIT STAGING PLAN TO COUNTY FOR APPROVAL.
CONTRACTOR STAGING AREA SHALL BE AT BEEMAN PARK. CONTRACTOR 3.
ACCESS TO PROJECT SITE SHALL BE VIA BARGE.2.
NO ROADWAY CLOSURES WILL BE ALLOWED.1.
NOTES:
LAKESIDE DR
L A
K E
S
H O
R E
D
LAKESIDE DR
SUE AVE
ROWENA AVE
B U
M B
Y
S
T
LEU RD
W O
O D
L A
W N
RIDGE AVE
WOODSIDE AVE
L A
K E
S
U
LAKE SUE
LAKE ROWENA
PROJECT SITE
SITE PLAN
zur32601 Text Box *The information depicted in this PDF markup, including utility locations, invert elevations, pipe material, pipe sizing, and service lateral locations, contain third party information for reference purposes only. Field verification is required for exact locations, inverts, materials, sizing, lengths, and rim elevations. The information included in this markup shall not be used by the recipient for preparation of construction plans or otherwise used for construction without field verification of the information.
Mul35963 Text Box Plans to be marked up using the following color codes:
RED: Existing Utilities that are to be:
(a) To be removed or relocated horizontally or
(b) To be placed out-of-service (deactivated) but left in place.
GREEN: Existing Utilities to remain in place with no adjustment.
BROWN: New Utilities zur32601 Text Box Mark-Up City of Orlando Water Reclamation Division by: Rudy Mulamba, E.I.
7/30/2024
.5
.3
.6
.1
.8
.7
.2
.4
.2
.0
.1
.7
.9
.5
.7
.3
.0
.6
.6
.2
74.07
74.17 .9
74.98 .9
.9
.1
.2
.1
.3
.3 573.24
.3
.1
.0
.9
74.99
.8
.0
.8
7 7 .1
75.65 .5
.6
75.48
72.38
.7
.3
.9
.4
72.57
70.49 .9
70.09 .5 1 74.96
.7
.7
.0
74.67
.8
70.33
69.47
.2
74.11
.4
73.51
.4
.3
.3 3 74.09
.5
.6
77.91
.9
.6
.5
.0
75.94
75.73
75.7675.83
75.88
.6
.2
.4
74.43
74.40
.1
.7
73.33
73.15
.9
73.20
73.3373.21
73.20
.2
.2
.9
.3
.4
74.53
74.43
78.57
.5
78.60
.6
.5
.3
.5
.4
.1
.7
74.70
74.71
.2
.0
.8
.3
.8
.8
.9
.1
.3
.5
.9
.4
.5
.0
.8
.7
.1
.6
.5
.1
.5
.8
.3
.0
.1
W A
T E
R
78.93
78.93
79.14
79.09
.0
.2
.7
.6
.9
.7
.7
.9
.5
.7
.9
.5
.7
.9
.5
I N
V E
R T
.6
O B
V E
R T
.0
C
M P
I N
V E
R T
.7
O B
V E
R T
.0
C
M P
I N
V E
R T
.5
O B
V E
R T
.0
C
M P
H E
D G
E
H E
D G
E
H E
D G
E
A S
P H
A L T
P
A T
C H
I N
V E
R T
R
C P
W I T
H L
I N
E R
.2
I N
V E
R T
R
C P
W I T
H L
I N
E R
.8
I N
V E
R T
V
C P
.8
' IR
O N
F E
N C
E
' V
IN
Y
L F
E N
C E
R I P
R
A P
R I P
R
A P
' W
ID
E
M A
S O
N R
Y W
A L
L
R I P
R
A P
R I P
R
A P
C A
N A
L
W
T O
P O
F W
A T
E R
.8
E L
E V
A T
IO
N
.2
S E
A S
O N
A L
H
IG
H W
A T
E R
M A
R K
RIP RAP
W
E D
G E
O F
P A
V E
M E
N T
101+00
W
DESCRIPTIONDATE DESCRIPTION DATE
REVISIONS
FLORIDA
GOVERNMENT
ORANGE COUNTY
SHEET NO.
REF. DWG. NO.SHEET TITLE:
PROJECT NAME:
BRIDGE NO. ???????
ORLANDO, FL. 32817
11723 ORPINGTON ST. SUITE 100
SINGHOFEN HALFF
P.E. LICENSE NUMBER 51373
ROBERT GAYLORD, P.E.
PIPE CULVERT REPAIR
LAKESIDE DRIVE OVER LAKE ROWENA/LAKE SUE
N
EXISTING 120" CMP
EXISTING GRADE
CONSTRUCTION BASELINE
L A
K E S
ID
E X I S
T I N
G
R C P
E X I S
T I N
G
R C P
E X I S
T I N
G
V C P
EX. WALL
EX. WALL
E X
W A
L L
EX. WALL
EX. WALL
PLAN & PROFILE
Mul35963 Line
Mul35963 Callout City of Orlando
3" PVC
Sewer Force Main (to remain) zur32601 Text Box *The information depicted in this PDF markup, including utility locations, invert elevations, pipe material, pipe sizing, and service lateral locations, contain third party information for reference purposes only. Field verification is required for exact locations, inverts, materials, sizing, lengths, and rim elevations. The information included in this markup shall not be used by the recipient for preparation of construction plans or otherwise used for construction without field verification of the information.
Mul35963 Text Box Plans to be marked up using the following color codes:
RED: Existing Utilities that are to be:
(a) To be removed or relocated horizontally or
(b) To be placed out-of-service (deactivated) but left in place.
GREEN: Existing Utilities to remain in place with no adjustment.
BROWN: New Utilities
| df-LD-Layout1-Default-000 |
| Untitled |
File details come from the government source that posted it. Updated .