7110--Mobile Laboratory Casework Pathology Lab Renov Togus VA Medical Center Augusta ME 04330
Solicitation number
36C24126Q0266
Issued by

About this file

This document is a data sheet and design specification for the renovation of laboratory spaces at the VA Medical Center in Togus, Maine, specifically detailing Phase 2 construction of pathology and laboratory medicine areas. The document includes detailed furniture and equipment schedules for three laboratory rooms: Room 157/157A (Histology), Room 267 (Blood Bank), and Room 269 (Microbiology).

The histology room (157/157A) specifies 50+ pieces of equipment and furniture from manufacturers including Mott Manufacturing, Thermo Scientific, Leica, Sakura, and Fisher Scientific, with items ranging from lab tables with shelves to specialized equipment such as tissue processors, microtomes, cryostats, and automated staining systems. The blood bank room (267) includes approximately 30 items featuring equipment from manufacturers such as Ortho Clinical Diagnostics, Clay Adams, and Helmer, including blood testing systems, centrifuges, plasma thawers and freezers, and incubators. The microbiology room (269) contains roughly 35 items from suppliers including Siemens, Bruker, BD, and Thermo Scientific, with equipment such as automated analyzers (MicroScan, BACTEC, MALDI), incubators for various bacterial cultures, biosafety hoods, and anaerobic chambers. Furnishing and installation codes indicate whether items are contractor-furnished and contractor-installed (CC), VA-furnished and contractor-installed (VC), or VA-furnished and VA-installed (VV), with most specialty equipment marked as existing in current locations (E) and being transferred (T) or repositioned (N) during the renovation phases.

View the file

Other files

File Type Posted
Basis of Design Mott-Optima_Redacted.pdf PDF
36C24126Q0266.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CC - CONTRACTOR-FURNISHED, CONTRACTOR-INSTALLED

VC - VA-FURNISHED, CONTRACTOR-INSTALLED

VV - VA-FURNISHED, VA-INSTALLED

R - RELOCATED

ALL MANUFACTURER/MODELS BASIS OF DESIGN UNLESS

OTHERWISE NOTED.

FURNISHING & INSTALLATION KEY CODES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

ISSUED FOR

CONSTRUCTION

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E PhaseARCHITECT STAMPCONSULTANTS 402-18-620

VA MAINE HEALTHCARE SYSTEM - TOGUS

PATHOLOGY & LABORATORY

MEDICINE RENOVATION

William Pevear Architects, Inc.

872 Massachusetts Ave. Suite 2-9 Cambridge, MA 02139

T: 617.335.5186

Andre Gill Engineering, LLC

40 Overlea Road North Smithfield, RI 02896

T: 401.441.3414

MECH/PLUMB ENGINEER:

Architectural Engineers, Inc.

63 Franklin Street Boston, MA 02110

T: 617.542.0810

ELEC/FP ENGINEER:

Drawing Scale

RSE Associates, Inc.

63 Pleasant Street, Suite 300 Watertown, MA 02472

T: 617.926.9300

STRUCTURAL ENGINEER:

321 4 5 6 7 8

A

B

C

D

E

321 4 5 6 7 8

1 VA CENTER AUGUSTA, ME 04330

02/13/2020

C :\U se rs

\a do rn .W

PA

\D oc um en ts

\V A

To gu s Pa th ol og y an d

La bo ra to ry M ed ic in e

R en ov at io n_ ad or n@ w illi am pe ve a r .c om . rv t 2/

/2

5:

:5

PM

As indicated

AS601A

157/157A HISTOLOGY ROOM

DATA SHEET

BUILDING 200 - LEVEL 1 BUILDING 200 - LEVEL 2

157 Histology - Furniture & Equipment Schedule

EXIST.

LOC.

LOCATION BY PHASE

# TAG CODE DESCRIPTION MANUFACTURER (B.O.D./EXISTING) MODEL (B.O.D./EXISTING)

FURN/INSTALL POWER & IT WATER OTHER

PH1 PH2 PH3

CONST.

COMPL. VC VV CC R RE

G.

EM

ER

G.

UP

S

DA

TA

CO

LD

HO

T

DR

AI

N

PU

R.

EX

H.

GA

S

Furniture -- -- -- (N) (N) 1 A1030 LOCKER BRADLEY LENOX Z-LOCKER 15"WX18"DX72"H - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0721A LAB TBL MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X48" TABLE - + - - - - - - - - - - - - -- -- -- (N) (N) 3 E0721C LAB TBL MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X60" TABLE - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0722B LAB TBL W/SHLV MOTT MANUFACTURING OPTIMA 2100-SQ, 36"X48" TABLE W/ SHELVING - + - - + + + + - - - - - - -- -- -- (N) (N) 1 E0722C LAB TBL W/SHLV MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X60" TABLE W/ SHELVING - + - - + + + + - - - - - - -- -- -- (N) (N) 2 E0722D LAB TBL W/SHLV MOTT MANUFACTURING OPTIMA 2100-SQ, 36"X60" TABLE W/ SHELVING - + - - + + + + - - - - - - -- -- -- (N) (N) 5 E0725C SUSP. CAB. DOOR/DRAWER/WRITING TABLET MOTT MANUFACTURING 1150222 - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0725D SUSP.CAB. DOOR/DRAWER/WRITING TABLET MOTT MANUFACTURING 1250222 - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0726G SUSP. CAB. OPEN SHELF/WRITING TABLET MOTT MANUFACTURING 1350000 - + - - - - - - - - - - - - -- -- -- (N) (N) 3 E0727 SUSP. CPU HOLDER MOTT MANUFACTURING CPU1010 - + - - - - - - - - - - - - -- -- -- (N) (N) 4 F0240 TASK CHAIR ALLSEATING - FOSTER GROUP 18025-WA-FA-F-OCDAN TASK CHAIR - + - - - - - - - - - - - - Specialty Equipment

-- -- -- (N) (N) 2 A5075 SOAP BOBRICK B-26607 - - + - - - - - - - - - - -

-- -- -- (N) (N) 2 A5080 PAPER TWL KIMBERLY CLARK VA TOGUS STANDARD SURFACE MOUNT MANUAL PT - - + - - - - - - - - - - - (E)157 (E) (T) (N) (N) 2 A5106 SHARPS DISPOSAL VARIES SHARPS DISPOSAL - + - + - - - - - - - - - - (E)157 (E) (T) (N) (N) 1 E0948A WASTE CART EXISTING WASTE CART - + - + - - - - - - - - - - (E)157 (E) (T) (N) (N) 1 F2026 REC. BIN EXISTING RECYCLE BIN - + - + - - - - - - - - - - (E)157 (E) (T) (N) (N) 1 L1401 OVEN UC EXISTING OVEN - UC - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 1 L1402 TISSUE PROCESSOR 1 SAKURA TISSUE TEK VIP 5 - + - + - + + + - - - - - - (E)157 (E) (T) (N) (N) 1 L1403 TISSUE PROCESSOR 2 SAKURA TISSUE TEK VIP 6 - + - + - + + + - - - - - - -- -- (T) (N) (N) 1 L1502 CART METRO STARSYS, STANDARD, 24"WX23"DX36"H - + - - - - - - - - - - - - (E)157 (E) (T) (N) (N) 1 L1602 PUR. WATER U/C MILLI-Q WATER FILTRATION SYSTEM - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 1 L1700 BIOSAFETY HOOD EXISTING BIOSAFETY HOOD - + - + - - - - - - - - + - (E)157 (E) (T) (N) (N) 1 L1701 GROSSING STATION GROSSLAB SENIOR - + - + - + + + + + + - + - (E)157 (E) (T) (N) (N) 2 L1801 COMPUTER INSTR. VARIES COMPUTER, DED. TO INST. - + - + - + + + - - - - - - (E)157 (E) (T) (N) (N) 1 L2206 CENTRIFUGE SILENCER S2 110SP - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 1 L2400 MICROSCOPE NIKON MICROSCOPE - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 1 L2401 VORTEXER FISHER SCIENTIFIC MINIROTO - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 2 L2402 WATER BATH EXISTING WATER BATH - + - + - + - - - - - - - (E)157 (E) (T) (N) (N) 1 L2407 HOT PLATE/ STIRRER EXISTING HOT PLATE - + - + - + - - - - - - - (E)157 (E) (T) (N) (N) 1 L2408 AUTO. STAIN. THERMO SCIENTIFIC VERISTAIN GEMINI - + - + - + + + - - + - + - (E)157 (E) (T) (N) (N) 1 L2409 EMBED. W.S. THERMO SCIENTIFIC HISTOSTAR - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 1 L2410 COLD PLATE THERMO SCIENTIFIC HISTOCENTRE 3 - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 2 L2411 CASSETTE PRINTER THERMO PRINTMATE AS - + - + - + + + - - - - - - (E)157 (E) (T) (N) (N) 1 L2412 VORTEXER FISHER SCIENTIFIC MINIROTO - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 1 L2413 OVEN - SMALL EXISTING OVEN - COUNTERTOP - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 2 L2414 MICROTOME LEICA HISTOCORE AUTOCUT - + - + - + - - - - - - - - (E)157 (E) (T) (N) (N) 2 L2415 SAMPLE PROCESSOR CYTYC THINPREP 2000 - + - + - + + - - - - - - - (E)157 (E) (T) (N) (N) 1 L2416 CRYOSTAT LEICA CRYOSTAT - + - + - + + - - - - - - - (E)157 (E) (T) (N) (N) 1 L2600 PUR. WATER RES. U/C MILLI-Q WATER FILTRATION SYSTEM RESERVIOR - + - + - + - - - - - + - - (E)157 (E) (T) (N) (N) 1 L2800 SLIDE PRINTER THERMO SCIENTIFIC SLIDE MATE - + - + - + + + - - - - - - (E)157 (E) (T) (N) (N) 2 L2801 SLIDE PRINTER THERMO SCIENTIFIC SLIDE MATE - + - + - + + + - - - - - - -- -- -- (N) (N) 4 M1015 VOIP PHONE VARIES VOIP TELEPHONE, DESKTOP - + - - - - - + - - - - - - -- -- (T) (N) (N) 4 M1801 NETWORK COMPUTER VARIES DESKTOP COMPUTER - + - - - + + + - - - - - - (E)157 (E) (T) (N) (N) 1 M1830 LABEL PRINTER EXISTING EXISTING - + - + - + + + - - - - - - (E)157 (E) (T) (N) (N) 1 M1841 MFD VARIES MFD - MULTIFUNCTIONAL DEVICE, DESKTOP - + - + - + + + - - - - - - (E)157 (E) (T) (N) (N) 2 M1842 HAND SCANNER EXISTING HAND SCANNER - + - + - - - - - - - - - - (E)157 (E) (T) (N) (N) 1 M2015 FLAMMABLE STRG EXISTING FLAMMABLE STORAGE CABINET - + - + - - - - - - - - - - (E)170 (E) (T) (N) (N) 1 M2015 FLAMMABLE STRG EXISTING FLAMMABLE STORAGE CABINET - + - + - - - - - - - - - - (E)157 (E) (T) (N) (N) 1 R6284 REF. THERMO HALF-HEIGHT REFRIGERATOR - + - + - + - - - - - - - -

157A - Histology Office - Furniture & Equipment Schedule

EXIST.

LOC.

LOCATION BY PHASE

# TAG CODE DESCRIPTION MANUFACTURER (B.O.D./EXISTING) MODEL (B.O.D./EXISTING)

FURN/INSTALL POWER & IT WATER OTHER

PH1 PH2 PH3

CONST.

COMPL. VC VV CC R RE

G.

EM

ER

G.

UP

S

DA

TA

CO

LD

HO

T

DR

AI

N

PU

R.

EX

H.

GA

S

Furniture -- -- -- (N) (N) 1 E0118 ADJ DESK HERMAN MILLER DU6ACS.3072LE - + - - + - - - - - - - - - -- -- -- (N) (N) 1 E0126 WKSTN HERMAN MILLER CANVAS SERIES WORKSTATION - + - - - - - - - - - - - - -- -- -- (N) (N) 1 F0240 TASK CHAIR ALLSEATING - FOSTER GROUP 18025-WA-FA-F-OCDAN TASK CHAIR - + - - - - - - - - - - - - -- -- -- (N) (N) 2 F0420 LAT. FILE CAB. HON H883 36"Wx18"Dx39"H, CHARCOAL - + - - - - - - - - - - - - Specialty Equipment -- -- -- (N) (N) 1 M1015 VOIP PHONE VARIES VOIP TELEPHONE, DESKTOP - + - - - - - + - - - - - - -- -- -- (N) (N) 1 M1801 NETWORK COMPUTER VARIES DESKTOP COMPUTER - + - - - + + + - - - - - - -- -- -- (N) (N) 1 M1825 DESKTOP PRINTER VARIES DESKTOP PRINTER - + - - - + + + - - - - - -

Revision: Date:

PHASE 2

HISTOLOGY

HISTOLOGY

OFFICE

157A

L1700

BIOSAFETY

HOOD

L2411

CASSETTE

PRINTER

M1841

MFD

L1701

GROSSING

STATION

L2416

CRYOSTAT

L2411

CASSETTE

PRINTER

L1403

TISSUE

PROCESSOR

L1402

TISSUE

PROCESSOR

E0948A

WASTE

CART

L2400

MICROSCOPE

M1801

NETWORK

COMPUTER

L2408

AUTO.

STAIN.

L2206

CENTRIFUGE

L2415

SAMPLE

PROCESSOR

L2407

HOT

PLATE/

STIRRER

M1830

LABEL

PRINTER

M1015

VOIP

PHONE

L1602

PUR.

WATER

U/C

L2415

SAMPLE

PROCESSOR

L1401

OVEN UC

E0126

WKSTN

E0118

ADJ

DESK

F0240

TASK

CHAIR

M2015

FLAMMABLE

STRG

M1801

NETWORK

COMPUTER

F2026

REC. BIN

L2410

COLD

PLATE

L2402

WATER

BATH

L2414

MICROTOME

L2409

EMBED.

W.S.

L2413

OVEN -

SMALL

L2402

WATER

BATH

L2801

SLIDE

PRINTER

L2801

SLIDE

PRINTER

L2414

MICROTOME

A5106

SHARPS

DISPOSAL

A5106

SHARPS

DISPOSAL

M1801

NETWORK

COMPUTER

L2800

SLIDE

PRINTER

M1015

VOIP

PHONE

M1801

NETWORK

COMPUTER M1015

VOIP

PHONE

M1015

VOIP

PHONE

F0240

TASK

CHAIR

M1015

VOIP

PHONE

F0240

TASK

CHAIR

F0240

TASK

CHAIR

F0240

TASK

CHAIR

M1801

NETWORK

COMPUTER

L1801

COMPUTER

INSTR.

M1842

HAND

SCANNER

L1801

COMPUTER

INSTR.

M1842

HAND

SCANNER

L2412

VORTEXER

L2401

VORTEXER

F0420

LAT. FILE

CAB.

M2015

FLAMMABLE

STRG

R6284

REF. UC

L1502

CART

A5080

PAPER

TWL

'-7

4 7

/8" 8'-

6"

EDCBA

L2600

PUR.

WATER

RES. U/C

MARKER BOARD

TACK BOARD

F0420

LAT. FILE

CAB.

A5080

PAPER

TWL

A5075

SOAP

E0721C

LAB TBL

B157F E0721A

LAB TBL

B157E

E0721C

LAB TBL

B157H

E0722D

LAB TBL

W/SHLV

B157C

E0722B

LAB TBL

W/SHLV

B157D

E0722C

LAB TBL

W/SHLV

B157B

A1030

LOCKER

E0721C

LAB TBL

B157A

M1825

DESKTOP

PRINTER

(2) VENTED ACID CABINETS BELOW

9'-6 3/4" 1'-10 1/2" 19'-1 1/4" 4 7/8" 8'-2 7/8"

9'-

7/ 8"

14'-1 1/2"

5'-1 3/4" 22'-7 1/4"

'-8

CUTTING/EMBEDDING AREA

E0722D

LAB TBL

W/SHLV

B157A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

ISSUED FOR

CONSTRUCTION

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E PhaseARCHITECT STAMPCONSULTANTS 402-18-620

VA MAINE HEALTHCARE SYSTEM - TOGUS

PATHOLOGY & LABORATORY

MEDICINE RENOVATION

William Pevear Architects, Inc.

872 Massachusetts Ave. Suite 2-9 Cambridge, MA 02139

T: 617.335.5186

Andre Gill Engineering, LLC

40 Overlea Road North Smithfield, RI 02896

T: 401.441.3414

MECH/PLUMB ENGINEER:

Architectural Engineers, Inc.

63 Franklin Street Boston, MA 02110

T: 617.542.0810

ELEC/FP ENGINEER:

Drawing Scale

RSE Associates, Inc.

63 Pleasant Street, Suite 300 Watertown, MA 02472

T: 617.926.9300

STRUCTURAL ENGINEER:

321 4 5 6 7 8

A

B

C

D

E

321 4 5 6 7 8

1 VA CENTER AUGUSTA, ME 04330

02/13/2020

C :\U se rs

\a do rn .W

PA

\D oc um en ts

\V A

To gu s Pa th ol og y an d

La bo ra to ry M ed ic in e

R en ov at io n_ ad or n@ w illi am pe ve a r .c om . rv t 2/

/2

5:

:0

PM

1/2" = 1'-0"

AS601B

157/157A HISTOLOGY ROOM

DATA SHEET

Revision: Date:

VV - VA-FURNISHED, VA-INSTALLED

R - RELOCATED

ALL MANUFACTURER/MODELS BASIS OF DESIGN UNLESS

OTHERWISE NOTED.

FURNISHING & INSTALLATION KEY CODES

BLOOD BANK

R6282

REFRIGERATOR

- 2 DOOR

L2418

TUBE

INC.

R5001

PLASMA

FREEZER

L2802

THERMAL

PRINTER

M1830

LABEL

PRINTER

L2110

BLOOD

TESTING

SYSTEM

L2400

MICROSCOPE

L2417

PLASMA

THAWER

L2402

WATER

BATH L2419

AGGLUT.

VIEWER

L2501

BLOOD

SAMPLE

RACK

L2204

CENTRIFUGE

L2502

PIPETTE

M1801

NETWORK

COMPUTER

R5004

ICE

MACHINE

M1801

NETWORK

COMPUTER

M1015

VOIP

PHONE

F0240

TASK

CHAIR

F0240

TASK

CHAIR

F0240

TASK

CHAIR

L2418

TUBE

INC.

L2419

AGGLUT.

VIEWER

L2501

BLOOD

SAMPLE

RACK

L2204

CENTRIFUGE

L2502

PIPETTE

M1801

NETWORK

COMPUTER

L3400

INST.

MONITOR

M1801

NETWORK

COMPUTER

M1842

HAND

SCANNER

M1842

HAND

SCANNER

M1842

HAND

SCANNER

M1825

DESKTOP

PRINTER

F0420

LAT. FILE

CAB.

26'-3 1/8"

R6010

INCUBATOR

F0418

PT CARD

FILE

CAB.

L2205

CENTRIFUGE

F0420

LAT. FILE

CAB.

F0420

LAT. FILE

CAB.

EDCB

C267C 0"W x 24"D

FH - 11

M1842

HAND

SCANNER

E0721C

LAB TBL

B267E

E0722A

LAB TBL

W/SHLV

B267D

E0722AH

LAB TBL

W/SHLV

HYD

B267C

E0722AH

LAB TBL

W/SHLV

HYD

B267A

E0722A

LAB TBL

W/SHLV

'-1

E0722A

LAB TBL

W/SHLV

B267B

E0721C

LAB TBL

B267E

E0721A

LAB TBL

B267F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

ISSUED FOR

CONSTRUCTION

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E PhaseARCHITECT STAMPCONSULTANTS 402-18-620

VA MAINE HEALTHCARE SYSTEM - TOGUS

PATHOLOGY & LABORATORY

MEDICINE RENOVATION

William Pevear Architects, Inc.

872 Massachusetts Ave. Suite 2-9 Cambridge, MA 02139

T: 617.335.5186

Andre Gill Engineering, LLC

40 Overlea Road North Smithfield, RI 02896

T: 401.441.3414

MECH/PLUMB ENGINEER:

Architectural Engineers, Inc.

63 Franklin Street Boston, MA 02110

T: 617.542.0810

ELEC/FP ENGINEER:

Drawing Scale

RSE Associates, Inc.

63 Pleasant Street, Suite 300 Watertown, MA 02472

T: 617.926.9300

STRUCTURAL ENGINEER:

321 4 5 6 7 8

A

B

C

D

E

321 4 5 6 7 8

1 VA CENTER AUGUSTA, ME 04330

02/13/2020

C :\U se rs

\a do rn .W

PA

\D oc um en ts

\V A

To gu s Pa th ol og y an d

La bo ra to ry M ed ic in e

R en ov at io n_ ad or n@ w illi am pe ve a r .c om . rv t 2/

/2

5:

:2

PM

As indicated

AS605

267 BLOOD BANK ROOM DATA

SHEET

SCALE:

1A RDS Axon - 267 - Blood Bank

BUILDING 200 - LEVEL 1 BUILDING 200 - LEVEL 2

267 - Blood Bank - Furniture & Equipment Schedule

EXIST.

LOC.

LOCATION BY PHASE

# TAG CODE DESCRIPTION MANUFACTURER (B.O.D./EXISTING) MODEL (B.O.D./EXISTING)

FURN/INSTALL POWER & IT WATER OTHER

PH1 PH2 PH3

CONST.

COMPL. VC VV CC R RE

G.

EM

ER

G.

UP

S

DA

TA

CO

LD

HO

T

DR

AI

N

PU

R.

EX

H.

GA

S

Furniture -- (T) (T) (N) (N) 1 E0721A LAB TBL MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X48" TABLE - + - - - - - - - - - - - - -- (T) (T) (N) (N) 1 E0721C LAB TBL MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X60" TABLE - + - - - - - - - - - - - - -- (T) (T) (N) (N) 2 E0722A LAB TBL W/SHLV MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X48" TABLE W/ SHELVING - + - - - + + + - - - - - - -- (T) (T) (N) (N) 2 E0722AH LAB TBL W/SHLV HYD MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X48" TABLE W/ SHELVING, HYD.

ADJ.

-- (T) (T) (N) (N) 1 E0723C SUSP. CAB. 1-DOOR/WRITING TABLET MOTT MANUFACTURING 1150011 - + - - - - - - - - - - - - -- (T) (T) (N) (N) 2 E0723E SUSP. CAB. 1-DOOR/WRITING TABLET MOTT MANUFACTURING 1250011 - + - - - - - - - - - - - - -- (T) (T) (N) (N) 2 E0724C SUSP. CAB. 4-DRAWER/WRITING TABLET MOTT MANUFACTURING 1150066 - + - - - - - - - - - - - - -- (T) (T) (N) (N) 3 E0727 SUSP. CPU HOLDER MOTT MANUFACTURING CPU1010 - + - - - - - - - - - - - - -- (T) (T) (N) (N) 3 F0240 TASK CHAIR ALLSEATING - FOSTER GROUP 18025-WA-FA-F-OCDAN TASK CHAIR - + - - - - - - - - - - - - -- (T) (T) (N) (N) 1 F0418 PT CARD FILE CAB. HON H19723R - + - - - - - - - - - - - - -- (T) (T) (N) (N) 3 F0420 LAT. FILE CAB. HON H883 36"Wx18"Dx39"H, CHARCOAL - + - - - - - - - - - - - - Specialty Equipment

-- -- -- (N) (N) 1 A5075 SOAP BOBRICK B-26607 - - + - - - - - - - - - - -

-- -- -- (N) (N) 1 A5080 PAPER TWL KIMBERLY CLARK VA TOGUS STANDARD SURFACE MOUNT MANUAL PT - - + - - - - - - - - - - - (E)266 (T) (T) (N) (N) 1 L2110 BLOOD TESTING SYSTEM ORTHO CLINICAL DIAGNOSTICS WORKSTATION - + - + - + + - - - - - - - (E)266 (T) (T) (N) (N) 2 L2204 CENTRIFUGE CLAY ADAMS SEROFUGE 2001 - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 1 L2205 CENTRIFUGE GFMD SILENCER - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 1 L2400 MICROSCOPE NIKON MICROSCOPE - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 1 L2402 WATER BATH CMS 392-134 - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 1 L2417 PLASMA THAWER CYTOTHERM D4 - + - + - + - - - - + - - - (E)266 (T) (T) (N) (N) 2 L2418 TUBE INC. ORTHO CLINICAL DIAGNOSTICS ID-MICRO TYPING SYSTEM, INCUBATOR - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 2 L2419 AGGLUT. VIEWER CLAY ADAMS AGGLUTINATION VIEWER - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 2 L2501 BLOOD SAMPLE RACK EXISTING SAMPLE RACK - + - + - - - - - - - - - - (E)266 (T) (T) (N) (N) 2 L2502 PIPETTE EXISTING PIPETTE ON STAND - + - + - - - - - - - - - - (E)266 (T) (T) (N) (N) 1 L2802 THERMAL PRINTER ZEBRA Z4MPLUS - + - + - + - + - - - - - - (E)266 (T) (T) (N) (N) 1 L3400 INST. MONITOR HELMER INSTRUMENT MONITOR - + - + - + + + - - - - - - -- (T) (T) (N) (N) 1 M1015 VOIP PHONE VARIES VOIP TELEPHONE, DESKTOP - + - - - - - + - - - - - - -- (T) (T) (N) (N) 4 M1801 NETWORK COMPUTER VARIES DESKTOP COMPUTER - + - - - + + + - - - - - - -- (T) (T) (N) (N) 1 M1825 DESKTOP PRINTER VARIES DESKTOP PRINTER - + - - - + + + - - - - - - (E)266 (T) (T) (N) (N) 1 M1830 LABEL PRINTER ZEBRA GX420 - + - + - + + + - - - - - - (E)266 (T) (T) (N) (N) 4 M1842 HAND SCANNER EXISTING HAND SCANNER - + - + - - - - - - - - - - (E)266 (T) (T) (N) (N) 1 R5001 PLASMA FREEZER HELMER FREEZER W/ WALL-MOUNT MONITOR - + - + - + - - - - + - - - (E)258 (T) (T) (N) (N) 1 R5004 ICE MACHINE EXISTING ICE MACHINE - + - + - + - - + - + - - - (E)266 (T) (T) (N) (N) 1 R6010 INCUBATOR THERMO JEWITT INCUBATOR W/ WALL-MOUNT MONITOR - + - + - + - - - - - - - - (E)266 (T) (T) (N) (N) 1 R6282 REFRIGERATOR - 2 DOOR THERMO REVCO - + - + - + - - - - - - - -

SCALE: 1/2" = 1'-0"

1 RDS - Plan - 267 - Blood Bank

Revision: Date:

VV - VA-FURNISHED, VA-INSTALLED

R - RELOCATED

ALL MANUFACTURER/MODELS BASIS OF DESIGN UNLESS

OTHERWISE NOTED.

FURNISHING & INSTALLATION KEY CODES

MICROBIOLOGY

L2106

MICROSCAN

L2108

CEPHIED

L2107

MALDI

L1700

BIOSAFETY

HOOD

L2700

ANAEROBIC

CH.

M1830

LABEL

PRINTER

M1844

DESKTOP

MFD

M1801

NETWORK

COMPUTER

M1015

VOIP

PHONE

F0240

TASK

CHAIR

L2207

CENTRIFUGE

R6283

REF. 3

DOOR

L1300

INC. NON

CO2

L0001

MICROSCOPE

L2111

BD

AFFIRM

M1830

LABEL

PRINTER

M1842

HAND

SCANNER

M1801

NETWORK

COMPUTER

L1801

COMPUTER

INSTR.

L2109

BACTEC

L1801

COMPUTER

INSTR.

L1801

COMPUTER

INSTR.

L1801

COMPUTER

INSTR.

M1801

NETWORK

COMPUTER

F0240

TASK

CHAIR

L2304

INC.

CAMPY

L2302

INC.

FUNGAL

L2303

INC. CO2

- UC

L2301

INC.

QUINCY

M1825

DESKTOP

PRINTER

M1825

DESKTOP

PRINTER

M1825

DESKTOP

PRINTER

M1825

DESKTOP

PRINTER

M1825

DESKTOP

PRINTER

'-6

1/ 2"

L2301

INC.

QUINCY

M1015

VOIP

PHONE

M1842

HAND

SCANNER

M1015

VOIP

PHONE

EDCB

L2109

BACTEC

L2109

BACTEC

E0721A

LAB TBL

B269B

E0721CH

LAB TBL

HYD

B269B

E0721CH

LAB TBL

HYD

B269C

E0722E

LAB TBL

W/SHLV

B269D

E0722E

LAB TBL

W/SHLV

B269E

28'-3 1/8"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

ISSUED FOR

CONSTRUCTION

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E PhaseARCHITECT STAMPCONSULTANTS 402-18-620

VA MAINE HEALTHCARE SYSTEM - TOGUS

PATHOLOGY & LABORATORY

MEDICINE RENOVATION

William Pevear Architects, Inc.

872 Massachusetts Ave. Suite 2-9 Cambridge, MA 02139

T: 617.335.5186

Andre Gill Engineering, LLC

40 Overlea Road North Smithfield, RI 02896

T: 401.441.3414

MECH/PLUMB ENGINEER:

Architectural Engineers, Inc.

63 Franklin Street Boston, MA 02110

T: 617.542.0810

ELEC/FP ENGINEER:

Drawing Scale

RSE Associates, Inc.

63 Pleasant Street, Suite 300 Watertown, MA 02472

T: 617.926.9300

STRUCTURAL ENGINEER:

321 4 5 6 7 8

A

B

C

D

E

321 4 5 6 7 8

1 VA CENTER AUGUSTA, ME 04330

02/13/2020

C :\U se rs

\a do rn .W

PA

\D oc um en ts

\V A

To gu s Pa th ol og y an d

La bo ra to ry M ed ic in e

R en ov at io n_ ad or n@ w illi am pe ve a r .c om . rv t 2/

/2

5:

:4

PM

As indicated

AS606

269 MICROBIOLOGY ROOM

DATA SHEET

SCALE:

1A RDS Axon - 269 - Microbiology

BUILDING 200 - LEVEL 1 BUILDING 200 - LEVEL 2

269 - Microbiology - Furniture & Equipment Schedule

EXIST.

LOC.

LOCATION BY PHASE

# TAG CODE DESCRIPTION MANUFACTURER (B.O.D./EXISTING) MODEL (B.O.D./EXISTING)

FURN/INSTALL POWER & IT WATER OTHER

PH1 PH2 PH3

CONST.

COMPL. VC VV CC R RE

G.

EM

ER

G.

UP

S

DA

TA

CO

LD

HO

T

DR

AI

N

PU

R.

EX

H.

GA

S

Furniture -- -- -- (N) (N) 1 E0721A LAB TBL MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X48" TABLE - + - - - - - - - - - - - - -- -- -- (N) (N) 2 E0721CH LAB TBL HYD MOTT MANUFACTURING OPTIMA 2100-SQ, 30"X60" TABLE, HYD. ADJ. - + - - + - - - - - - - - - -- -- -- (N) (N) 2 E0722E LAB TBL W/SHLV MOTT MANUFACTURING OPTIMA 2100-SQ, 36"X72" TABLE W/ SHELVING - + - - - + + + - - - - - - -- -- -- (N) (N) 2 E0724C SUSP. CAB. 4-DRAWER/WRITING TABLET MOTT MANUFACTURING 1150066 - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0726B SUSP. CAB. OPEN SHELF/WRITING TABLET MOTT MANUFACTURING 1950000 - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0726E SUSP. CAB. OPEN SHELF/WRITING TABLET MOTT MANUFACTURING 1250000 - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0726G SUSP. CAB. OPEN SHELF/WRITING TABLET MOTT MANUFACTURING 1350000 - + - - - - - - - - - - - - -- -- -- (N) (N) 1 E0726J SUSP. CAB. OPEN SHELF/WRITING TABLET MOTT MANUFACTURING 1450000 - + - - - - - - - - - - - - -- -- -- (N) (N) 3 E0727 SUSP. CPU HOLDER MOTT MANUFACTURING CPU1010 - + - - - - - - - - - - - - -- -- -- (N) (N) 2 F0240 TASK CHAIR ALLSEATING - FOSTER GROUP 18025-WA-FA-F-OCDAN TASK CHAIR - + - - - - - - - - - - - - Specialty Equipment

-- -- -- (N) (N) 1 A5075 SOAP BOBRICK B-26607 - - + - - - - - - - - - - -

-- -- -- (N) (N) 1 A5080 PAPER TWL KIMBERLY CLARK VA TOGUS STANDARD SURFACE MOUNT MANUAL PT - - + - - - - - - - - - - - (E)270B (E) (E) (N) (N) 1 L0001 MICROSCOPE NIKON MICROSCOPE - + - + - + - - - - - - - - (E)270B (E) (E) (N) (N) 1 L1300 INC. NON CO2 THERMO SCIENTIFIC STERI-CYCLE - + - + - + - - - - - - - - (E)270B (E) (E) (N) (N) 1 L1700 BIOSAFETY HOOD EXISTING BIOSAFETY HOOD - + - + - + - - - - - + - (E)270B (E) (E) (N) (N) 4 L1801 COMPUTER INSTR. VARIES COMPUTER, DED. TO INST. - + - + - + + + - - - - - - (E)270A (E) (E) (N) (N) 1 L2106 MICROSCAN SIEMENS MICROSCAN WALKAWAY 40 PLUS - + - + - + + + - - - - - - (E)270B (E) (E) (N) (N) 1 L2107 MALDI BRUKER MALDI-TOF - + - + - + + + - - - - - - (E)270B (E) (E) (N) (N) 1 L2108 CEPHIED CEPHIED GENEXPERT - + - + - + + + - - - - - - (E)270B (E) (E) (N) (N) 3 L2109 BACTEC BD BACTEC FX40 - + - + - + + + - - - - - -

(E)270B (E) (E) (N) (N) 1 L2111 BD AFFIRM BD AFFIRM - + - + - + + + - - - - - -

(E)270A (E) (E) (N) (N) 1 L2207 CENTRIFUGE CYTOSPIN 4 THERMO SCIENTIFIC - + - + - + - - - - - - - - (E)270B (E) (E) (N) (N) 2 L2301 INC. QUINCY QUINCY INCUBATOR - + - + - + - - - - - - - - (E)270B (E) (E) (N) (N) 1 L2302 INC. FUNGAL PRECISION INCUBATOR-REFRIGERATED - + - + - + - - - - - - - - (E)270E (E) (E) (N) (N) 1 L2303 INC. CO2 - UC THERMO SCIENTIFIC STERI-CYCLE - + - + - + - - - - - - - + (E)270B (E) (E) (N) (N) 1 L2304 INC. CAMPY BOEKEL SCIENTIFIC INCUBATOR - + - + - + - - - - - - - - (E)270B (E) (E) (N) (N) 1 L2700 ANAEROBIC CH. ANAEROBE SYSTEMS AS-580 - + - + - + + - - - - - - + -- -- -- (N) (N) 3 M1015 VOIP PHONE VARIES VOIP TELEPHONE, DESKTOP - + - - - - - + - - - - - - -- -- -- (N) (N) 3 M1801 NETWORK COMPUTER VARIES DESKTOP COMPUTER - + - - - + + + - - - - - - -- -- -- (N) (N) 5 M1825 DESKTOP PRINTER VARIES DESKTOP PRINTER - + - - - + + + - - - - - - (E)270B (E) (E) (N) (N) 2 M1830 LABEL PRINTER EXISTING EXISTING - + - + - + + + - - - - - - (E)270B (E) (E) (N) (N) 2 M1842 HAND SCANNER EXISTING HAND SCANNER - + - + - - - - - - - - - - (E)270B (E) (E) (N) (N) 1 M1844 DESKTOP MFD TBD PRINT/FAX/SCAN - + - - - + + + - - - - - - (E)270E (E) (E) (N) (N) 1 R6283 REF. 3 DOOR THERMO SCIENTIFIC SIM TO MR72PAGAEE - + - + - + - - - - - - - -

SCALE: 1/2" = 1'-0"

1 RDS - Plan - 269 - Microbiology

Revision: Date:

File details come from the government source that posted it. Updated .