La_Habra_Library_SD_Set.pdf

PDF 9 MB Posted

Attached to
CONSTRUCTION MANAGER AT RISK (CMAR) FOR THE GARDEN GROVE MAIN LIBRARY & LA HABRA LIBRARY REMODEL PROJECT
Solicitation number
CMAR-RFP-080-2603601-JM
Issued by
Orange County, San Francisco City, California

About this file

This is a Schematic Design (SD) set of architectural drawings for the La Habra Library Refresh project, a tenant improvement and modernization effort overseen by the County of Orange, OC Public Works. The project involves comprehensive renovations to the existing library facility located at 221 E La Habra Boulevard, La Habra, California, to maintain continued and improved public use. The scope of work includes interior tenant improvements, ADA compliance upgrades, mechanical and electrical system updates, roof replacement, exterior repairs, and plumbing fixture installations. The building is classified as occupancy type A-3 (assembly), construction type III-N, single-story with approximately 13,994 square feet of existing building area. The design accommodates an occupant load of 265 people across multiple functional zones including reading areas, study rooms, children's areas, teen areas, community room, staff facilities, and mechanical spaces. The project includes five emergency exits to exceed code requirements (two required), maximum travel distance to exits of 85 feet (200 feet allowed), new LED lighting fixtures, acoustic ceiling replacement, new carpet tile flooring with various finishes throughout, restroom upgrades with new tile and fixtures, new interior partitions and doors, and ADA-compliant handrails and accessibility features. The design team includes architect John Silber (AIA), structural engineer Said Hilmy (PhD, SE), mechanical engineer Darren Smith, electrical engineer Steven Collins, and project manager Shelley Sivak, all from IDS Group Inc. Deferred submittals include fire alarm systems, fire sprinkler design, and OCFA approvals.

The project follows 2022 California Building Code, California Fire Code, California Energy Code, and 2010 ADA Standards. Key site improvements include reconstruction of the primary library entrance path and parking lot to ADA compliance standards, accessible parking spaces with proper dimensions and signage, exterior handrails and stairs meeting code requirements, a new code-compliant roof access hatch and ladder, landscaping modifications to accommodate new mechanical equipment with decorative screening, and courtyard surface repairs to eliminate hazardous variations. Interior improvements feature new plumbing fixtures meeting occupancy requirements (two water closets, four urinals, two male lavatories, two female lavatories, one drinking fountain), new break room cabinetry with refrigerator and microwave, staff lounge upgrades, new IT room created from converted storage, and a new custom millwork locker system. The design incorporates fire-rated separations and doors where required, with particular attention to electrical switchgear separation compliance. The schematic design submittal was completed on March 8, 2024, and prepared under IDS Group project number 22X085.06 with file location S:\PROJECTS\2022\SHARED\22X085.06 OCPW LA HABRA LIBRARY REFRESH. The County Project Manager is Matthew DeHart, OC Facilities Design & Construction, located at 601 N. Ross Street, 4th Floor, Santa Ana, California 92701.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET # SHEET NAME

PROJECT INFORMATION & DRAWING INDEX

GENERAL NOTES

G-001

G-002

CAL GREEN GENERAL NOTES

G-003

CAL GREEN GENERAL NOTES

G-004

CAL GREEN GENERAL NOTES

G-006

GENERAL

ACCESSIBILITY COMPLIANCE NOTES & DETAILS

G-006

G-007

NUMBER OF SHEETS

X

G E

N E

R A

L

N

O T

E S

D

R A

W I N

G

I N

D E

X

G-001

601 N. ROSS STREET, SANTA ANA, CA 92701

OC PUBLIC WORKS / OC FACILITIES DESIGN & CONSTRUCTION

A&E PROJECT MANAGEMENT SECTION

VICINITY MAP

SITE MAP / FACILITY MAP

BOARD OF SUPERVISORS

C O

U N

YT

OF O RA

N G

E

C

A L I F O RN

IA

COUNTY APPROVAL STAMP

JAMES TREADAWAY, PE, SE, DIRECTOR

SANTA ANA, CALIFORNIA

PublicWorks

OC FACILITIES DESIGN &

CONSTRUCTION

OC PUBLIC WORKS

Approve in Concept

Date:

Section Manager:

Project Manager:

Plan No.

Sheet

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

O

R ev is io ns

S ym

D es cr ip

B y

D at e

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n A

-E S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

County Project Manager:

Name Title Date

Client Staff & Representatives:

CLIENT NAME

CLIENT DEPARTMENT

Address

Title:

Name:

Address:

Title:

Name:

Address:

Phone:

Title:

Name:

Address:

Phone:

Title:

Name:

Address:

Phone:

Client Approvals:

Name Title Date Name Title Date

Name: Matthew DeHart

Address: 601 N. Ross Street, 4th Floor, Santa Ana,CA 92701

Phone: 714-667-4972

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

F

A X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

I D

S

G

R O

U P

I L E

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

H

B

I B

R A

Y

F

R E

S H

C

A D

A

R C

H X

G

P

R O

J E

C T

N

F O

R M

A T

I O

D

A

W I N

G

I N

D

X

O

T

D

A T

E

M

S E

R

M

A H

S A

J A

V A

H E

R I A

N

LA HABRA LIBRARY REFRESH

DRAWING INDEX

Matthew DeHart 601 N. Ross Street, 4th Floor, Santa Ana,CA 92701

Senior Project Manager, OC Public Works

ANDREW DO, VICE-CHAIRMAN

CHAIRMAN

DOUG CHAFFEE,

VICENTE SARMIENTO

DONALD P. WAGNER,

SECOND DISTRICT

FIRST DISTRICT

FIFTH DISTRICTKATRINA FOLEY,

FOURTH DISTRICT

B

M I T

T A

L

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

OC

PW

9-

2-

9-

PL

-1

221 E LA HABRA BLVD, LA HABRA, CA 90631

M

J S

S

CODE REFERENCES

PROJECT INFORMATION

DESIGN TEAM

DEFERRED SUBMITTALS

1.FIRE ALARM

2.FIRE SPRINKLER

3.OCFA APPROVALS

2022 CALIFORNIA ADMINISTRATIVE CODE (CAC)

2022 CALIFORNIA BUILDING CODE (CBC)

2022 CALIFORNIA ELECTRICAL CODE (CEC)

2022 CALIFORNIA MECHANICAL CODE (CMC)

2022 CALIFORNIA PLUMBING CODE (CPC)

2022 CALIFORNIA FIRE CODE (CFC)

2022 CALIFORNIA ENERGY CODE

2010 ADA STANDARDS

CONTRACTOR'S NATIONAL ASSOCIATION (SMACNA)

AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)

AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME)

PROJECT MANAGER:

SHELLEY SIVAK

IDS GROUP INC.

1 PETERS CANYON ROAD, SUITE 130

IRVINE, CALIFORNIA 92606

PHONE: 949-387-8500 EXT 188

EMAIL: SHELLEY.SIVAK@IDSGI.COM

STRUCTURAL ENGINEER:

SAID HILMY, PhD, SE

IDS GROUP INC.

1 PETERS CANYON ROAD, SUITE 130

IRVINE, CALIFORNIA 92606 PHONE:

949-387-8500 EXT 116

ELECTRICAL ENGINEER:

STEVEN COLLINS

IDS GROUP INC.

1 PETERS CANYON ROAD, SUITE 130

IRVINE, CALIFORNIA 92606 PHONE:

949-387-8500 EXT 325

ARCHITECT OF RECORD:

JOHN SILBER, AIA

IDS GROUP INC.

1 PETERS CANYON ROAD, SUITE 130

IRVINE, CALIFORNIA 92606

PHONE: 949-387-8500 EXT 157

MECHANICAL ENGINEER:

DARREN SMITH

IDS GROUP INC.

1 PETERS CANYON ROAD, SUITE 130

IRVINE, CALIFORNIA 92606

PHONE: 949-387-8500 EXT 454

PLUMBING ENGINEER:

DARREN SMITH

IDS GROUP INC.

1 PETERS CANYON ROAD, SUITE 130

IRVINE, CALIFORNIA 92606

PHONE: 949-387-8500 EXT 454

SCOPE OF WORK:

THE TENANT IMPROVEMENT OF THE EXISTING LIBRARY FOR A CONTINUED

AND IMPROVED USE OF THE PUBLIC FACILITY. THE BUILDING IS LOCATED

ON THE LA HABRA BLVD IN CITY OF LA HABRA, COUNTY OF ORANGE,

STATE OF CALIFORNIA.

OCCUPANCY TYPE: A-3

CONSTRUCTION TYPE: III-N

FIRE SPRINKLERS: NO

NUMBER OF STORIES: NO CHANGE - 1 STORY

BUILDING AREA: NO CHANGE - EXISTING

PROJECT

LOCATION

PROJECT

LOCATION

a.

b.

c.

d.

e.

f.

g.

GENERAL

THESE PLANS ARE THE PROPERTY OF IDS GROUP INC., AND ARE NOT TO BE USED FOR ANY OTHER THAN THE LOCATION

SHOWN HEREON.

1. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE AND CONSENT OF THE ARCHITECT OR

ENGINEER WHOSE SIGNATURE APPEARS HEREON.

2. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF CONCRETE MASONRY UNITS, CENTERLINE OF COLUMNS AND BEAMS, OR FACE OF STUDS, UNLESS OTHERWISE NOTED. FINISH FLOOR ELEVATIONS

ARE TO TOP OF CONCRETE SLAB OR TOP OF INTERIOR PAVING UNLESS OTHERWISE NOTED.

3. ALL LEVELS REFERENCE POINTS ARE TAKEN FROM TOP OF SHEATHING OR TOP OF CONC. SLAB/COMBO DECKING.

DIMENSIONS ON ELEVATIONS, SECTIONS AND WALL SECTIONS ARE REFERENCED TO THESE POINTS, UNLESS NOTED.

4. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL. REQUEST FOR SUBSTITUTIONS SHALL

BE IN ACCORDANCE WITH THE SPECIFICATIONS OF SHEETS G-901,902 , 903 AND ETC.

THESE DRAWINGS DO NOT CONTAIN THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY.

ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE STATE CONSTRUCTION SAFETY ORDERS

ENFORCED BY THE STATE DIVISION OF INDUSTRIAL SAFETY.

CODES

CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA BUILDING CODE, ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS GOVERNING THE

WORK. IN CASE OF CONFLICTS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN.

PERMIT

1. THE CONSTRUCTION OR DEMOLITION OF ANY BUILDING, STRUCTURE,USING SCAFFOLDING OR FALSEWORK MORE THAN 3 STORIES OR 36'-0" IN HEIGHT, REQUIRES A PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL

SAFETY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ( 1PC.B.9 )

2. A PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS IS REQUIRED FOR A PROTECTION FENCE OR CANOPY ON OR OVER ANY STREET OR PUBLIC SPACE. PROTECTION OF PEDESTRIANS DURING CONSTRUCTION SHALL BE PROVIDED PER

C.B.C. SECTION 3303.

3. ALL ROOMS ARE REQUIRED TO BE MARKED WITH APPROVED SIGNAGE.

4. OBTAIN PERMIT FROM CITY ENGINEER PRIOR TO DOING ANY SIDEWALK AND CURB WORK.

5. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. REFER TO SHEET G-001 FOR LIST OF DEFERRED SUBMITTALS.

METAL WORK

1. ALL METAL FRAMING MEMBERS SHALL BE ARRANGED AND SPACED AS TO PERMIT INSTALLATION OF PIPE CONDUITS AND DUCTWORK WITH A MINIMUM OF CUTTING. SHAFT WALLS SHALL BE PROVIDED WITH NECESSARY FRAMES, BRACING, AND SEALANT AROUND THE OPENING.

2. CONTACT BETWEEN DISSIMILAR METAL SHALL BE PROTECTED.

WOOD WORK INCLUDING METAL STUDS

1. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE FLUSH. IF STRUCTURAL PANELS ARE REQUIRED ON A WALL PLANE, THE ENTIRE WALL PLANE SHALL BE FURRED OR FINISHED FLUSH.

2. INSTALL METAL CORNER BEADS AT ALL EXPOSED WALLBOARD EDGES. INSTALL CASING BEADS WHEREVER WALLBOARD, PLASTER, ETC. ABUTS A DISSIMILAR FINISH MATERIAL AND PROVIDE SEALANT AS REQUIRED.

3. GYPSUM BOARD SHALL EXTEND TO UNDERSIDE OF STRUCTURE ABOVE AT ALL EXTERIOR PERIMETER WALLS

DOORS

1. DOORS IN RATED WALLS SHALL CONSIST OF SELF-CLOSING, SELF-LATCHING ASSEMBLIES WITH SMOKE AND DRAFT SEALS AT HEAD AND JAMBS. DOOR ASSEMBLY RATINGS SHALL BE AS INDICATED ON DOOR SCHEDULE. HOLD OPEN DEVICES ON RATED ASSEMBLIES SHALL BE MAGNETICALLY OPERATED AND ACTIVIATED BY SMOKE DETECTORS.

2. DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR THRESHOLDS, ECT., SHALL BE TAKEN OFF THE DOOR. DOORS AND FRAMES SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS, AND

HARDWARE.

3. AIR LEAKAGE AT EXTERIOR DOORS SHALL BE LIMITED BY THE FOLLOWING:

ALL DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE AT THE HEAD AND SILL.

DOORS MOUNTED ON EITHER THE INSIDE OR OUTSIDE OF AN EXTERIOR WALL SHALL HAVE A MINIMUM 1/2" LAP AT

EACH JAMB.

DOORS REQUIRING VERTICAL TRACK OR GUIDES SHALL USE A CONTINUOUS MOUNTING ANGLE, SEALED IN

ACCORDANCE WITH "G" LISTED HERE.

DOORS MOUNTED BETWEEN THE JAMBS SHALL HAVE A CONTINUOUS SEAL OR BAFFLE AT EACH JAMB.

MEETING RAILS OR SECTION DOORS AND MEETING STILES OR RAILS OR BI-PARTING DOORS SHALL BE PROVIDED

WITH A SEAL, ASTRAGAL, OR BAFFLE.

SWINGING DOORS SHALL BE WEATHERSTRIPPED AT THE HEAD, SILL AND JAMBS.

OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALL AND FOUNDATIONS, BETWEEN WALL AND ROOF, BETWEEN WALL PANELS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND ROOFS AND ALL OTHER OPENINGS IN THE EXTERIOR ENVELOPE SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO CREATE AN AIRTIGHT ASSEMBLY.

ACCESSIBILE FIXTURES & SIGNAGE

N

N

G-008

EGRESS FLOOR PLAN

A-111

DEMOLITION FLOOR PLAN

A-211

FLOOR PLAN

-0

1-

BUSINESS - OFFICE

ASSEMBLY-UNCONCENTRADED- CHAIRS

& TABLES

STORAGE-MECHANICAL ROOM

READING ROOMS

STACKS

NO OCCUPANTS

M

A

X

V

E

R

A

A

G

O

N

A

L

INFORMATION

CORRIDOR

FRIENDS

OF

LIBRARY

FRIENDS

OF

LIBRARY

MEN

CONMUNITY ROOM

COURTYARD

STAFF

BATHROOM

IT

ROOM

MECH

WOMEN

LOBBY

STORAGE

JANITOR

STUDY

ROOM

LIBRARIAN

STAFF

LOUNGE

STUDY

ROOM

STUDY

ROOM

WORK

ROOM

D

F

CHILDREN READING AREA

PRINTER

SELF CHECK-OUT

COMMON AREA

ADULT READING AREA

TEEN READING AREA

LAPTOPS

TEEN READING AREA

PC RES OPAC

B O

O K

D R

O P

T V

L O

W

S

H E

L V

I N

G

CHILDREN SEATING AREA &

MOBILE SHELVING

STORAGE

M W

RAISED GARDEN

DN.

A/C

TRASH

ENCLOSURE

BLR

BLR

H

R

R

E F

U G

E

A

R E

A

EXIT / TRAVEL DISTANCE =85'

EXIT 1

EXIT 2

EXIT 3

EXIT 4

EXIT 5

LIFE & SAFETY BUILDING CODE SUMMARY CODE ANALYSIS

INTERIOR TENANT IMPROVEMENTS FOR AN OFFICE FACILITY

WHICH IS SUBMITTED AS A "B" OCCUPANCY, PER 2022 CBC -

CHAPTER 3, SECTION 304.1

2022 CBC - CHAPTER 10:

THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE

ILLUMINATED AT ALL TIMES THAT THE ROOM OR SPACE IS

OCCUPIED. (CBC-1008.2)

THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT

LESS THAN 1-FOOT CANDLE (11 LUX) AT THE WALKING SURFACE

LEVEL.

THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION

SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL

SUPPLY (CBC 1008.3).

THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR

THE DURATION OF NOT LESS THAN 90 MINUTES AND SHALL

CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN

ON-SITE GENERATOR. (CBC 1008.3.4)

PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN

LOCATIONS NOTED ON CFC 906.1.

EGRESS ANALYSIS:

-EXITS REQUIRED:

OCCUPANT LOAD: 265 OCC

OCCUPANCY: A-3

EXITS REQUIRED (CBC TABLE 1006.3.3): 2

EXITS PROVIDED: 5

-EXITS SEPARATION (WITOHUT SPRINKLER SYSTEM):

-NUMBER OF EXITS PROVIDED: 5

-LONGEST DIAGONAL OF OCCUPIED SPACE: 229'-0"

-REQUIRED SEPARATION OF EXITS: 229'/2=114.5'

-EGRESS COMPONENT WIDTH REQUIRED (CBC 1005.3.2)

DOORWAYS:265 OCC/ 5 EXITS = 53 OCC PER EXIT (0.2)= 10.6"

PROVIDED: (PROVIDED: 36" MIN)

EXIT 1 = 3'-9" OCC. DISCHARGE = 53

EXIT 2 = 3'-9" OCC. DISCHARGE = 53

EXIT 3 = 3'-0" OCC. DISCHARGE = 53

EXIT 4 = 3'-0" OCC. DISCHARGE = 53

EXIT 5 = 6'-0" OCC. DISCHARGE = 53

-MAXIMUM TRAVEL DISTANCE TO EXITS (WITHOUT AUTOMATIC SPRINKLER SYSTEM THROUGHOUT

(CBC TABLE 1017.2):

ALLOWED 200' PROVIDED : MAX 85'

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

-E S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

G

E

G R

E S

S

F

L O

O

T

D

A T

E

E

R

M

A H

S A

J A

V A

H E

R I A

N

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

EGRESS FLOOR PLAN

C O

A

L Y

S I S

G-008

N

OCCUPANCY LEGEND

(TABLE1004.5 CBC)

OFFICE (BUSINESS) 3,152 SF/150 = 22 OCC.

READING 4,589 SF/50 = 92 OCC.

ASSEMBLY-UNCONC. CHAIRS & TABLES 1,731 SF/15 = 116 OCC.

STORAGE 157 SF/300 = 1 OCC.

STACKS 3,396 SF/100 = 34 OCC.

TOTAL 265 OCC.

ASSEMBLY GROUP A-3 (LIBRARY)

PLUMBING FIXTURES CALCULATIONS

PLUMBING FIXTURE REQUIRED

WATER CLOSET URINALS LAVATORIES

MALE FEMALE MALE FEMALEMALE

2 4 2 1 2

PROVIDED 2 4 2 2 2

DRINKING FOUNTAINS

ALLOWABLE AREA DETERMINATION: (TABLE 506.2)

TYPE OF CONSTRUCTION: III-B

TYPE OF OCCUPANCY: A-3

EXISTING BUILDING AREA: 13,994 SQ.FT.

BASIC ALLOWABLE FLOOR AREA: 9,500 SQ.FT.

= 9,500 + (9500 X 0.50) =

= 14,250 SQ.FT. (ALLOWABLE AREA) > 13,994 SQ.FT.

375' / 655' = 0.57 X 100 = 57 %

TABLE 506.3.3, OPEN SPACE 30' OR GREATER = 0.50

-0

1-

S T

L

A

H

A B

B

U

L E

V A

R D

NORTH ORANGE STREET

ZUTANO LN

NO PARKING

EXISTING PARKING

E X

I S

T I N

G

P

A R

K I N

G

INFORMATION

CORRIDOR

FRIENDS

OF

LIBRARY

FRIENDS

OF

LIBRARY

MEN

CONMUNITY ROOM

COURTYARD

STAFF

BATHROOM

IT

ROOM

MECH

WOMEN

LOBBY

STORAGE

JANITOR

STUDY

ROOM

LIBRARIAN

STAFF

LOUNGE

STUDY

ROOM

STUDY

ROOM

WORK

ROOM

D

F

CHILDREN READING AREA

PRINTER

SELF CHECK-OUT

COMMON AREA

ADULT READING AREA

TEEN READING AREA

LAPTOPS

TEEN READING AREA

PC RES OPAC

B O

O K

D R

O P

T V

L O

W

S

H E

L V

I N

G

CHILDREN SEATING AREA &

MOBILE SHELVING

STORAGE

M W

RAISED GARDEN

DN.

A/C

TRASH

ENCLOSURE

BLR

H

R

R

E F

U G

E

A

R E

A

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

S

I T

E

P

L

O

T

D

A T

E

E

R

S

H E

L L E

Y S

I V

A K

A E

D L

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/16" = 1'-0"

SITE PLAN

S I T

E

P

L A

N

A-011

N

PROVIDE CODE COMPLIANT PATH OF TRAVEL FROM PUBLIC SIDEWALK TO BUILDING ENTRANCE.

PLACE NECESSARY UNAUTHORIZED VEHICLES SIGN AT EACH ENTRANCE.

ACCESSIBLE PARKING SPACES ASPHALT SURFACE TO BE RECONSTRUCTED WITH GRADES NOT TO EXCEED 2% IN ANY DIRECTION PER ADA REQUIREMENTS.

THE ACCESS AISLE FOR VAN ACCESSIBLE PARKING TO BE REVISED TO 8'-0" WIDTH.

RESTRIPE ACCESS AISLE WITH WORDS “NO PARKING” WITH WHITE LETTERS MINIMUM 12” IN HEIGHT TO BE VISIBLE FROM ADJACENT VEHICULAR WAY.

DEMOLISH CONCRETE PATH, GRADE SURFACE TO LEVEL WITH ADJACENT GROUND USING CLEAN FILL SOIL AND REPLACE WITH NEW COMPLIANT PATH.

THE PRIMARY LIBRARY ENTRANCE PATH TO BE RECONSTRUCTED TO BE ADA COMPLIANT.

THE EXTERIOR BOOK DROP BOX SHALL COMPLY WITH 2022 CBC CODE FOR REACH RANGES.

COURTYARD CONTAINS ABRUPT EDGES AND/OR VARIATIONS OVER 1/4" THROUGHOUT, TO BE RECONSTRUCTED TO COMPLY WITH 2022 CBC.

EXTERIOR STAIRWAY & HANDRAIL SHALL COMPLY WITH 2022 CBC CODE.

RELOCATE AND REPLACE ROOF HATCH TO PROVIDE CODE COMPLIANT ACCESS.

ARBORIST TO EVALUATE TREE TO DETERMINE IF IT CAN BE SAVED WHEN CONCRETE SLAB IS REPLACED.

REMOVE EXISTING LANDSCAPE AND PREPARE THE AREA FOR INSTALLING THE BOILER AND DECORATIVE SCREEN ENCLOSURE ON A CONCRETE PAD.

NOT USED

(E) BUILDING

MAIN ENTRANCE

(E) PUBLIC SIDEWALK

PATH OF TRAVEL

FROM PUBLIC WAY

-0

1-

CORRIDOR

STORAGE

AV

ROOMKITCHEN

FRIENDS

OF

LIBRARY

FRIENDS

OF

LIBRARY

MEN

CONMUNITY ROOM

COURTYARD

STAFF

BATHROOM

IT

ROOM

MECH

WOMEN

STORAGE

JANITOR

STAFF

LOUNGE

D

F

INFORMATION

DESK AREA

RAISED GARDEN

DN.

A/C

TRASH

ENCLOSURE

BLR

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

D

E M

O L I T

I O

N

F

L O

O

T

D

A T

E

E

R

S

H E

L L

E Y

S

I V

A K

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

DEMOLITION FLOOR PLAN

D E

M O

L I T

I O

N

F

L O

A

N

A-111

N

LEGEND

EXISTING CONSTRUCTION TO BE DEMOLISHED

EXISTING CONSTRUCTION TO REMAIN

EXISTING INTERIOR NON-STRUCTURAL PARTITION WALL TO BE REMOVED.

EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED.

REMOVE EXISTING FLOOR FINISH AND BASE.REMOVE ALL ADHESIVES, PREPARE SURFACE TO

RECEIVE NEW FINISH.

EXISTING MILLWORK TO BE DEMOLISHED. CAP EXISTING WIRE AND PATCH & REPAIR THE SLAB AS

NECESSARY.

EXISTING FURNITURE TO BE REMOVED AND RETURNED TO OWNER.

EXISTING BOOK SHELVES TO BE REMOVED AND RETURNED TO OWNER.

EXISTING NON-COMPLIANT ROOF ACCESS CLOSET, LADDER AND HATCH TO BE REMOVED.

REMOVE EXISTING COUNTERTOP/MILLWORK AND BASE CABINET AND SINK.

FIRE ALARM PANEL TO REMAIN.

EXISTING STORAGE ROOM TO BE CONVERTED TO IT CLOSET.

EXISTING MECHANICAL ROOM TO REMAIN.

EXISTING PLUMBING FIXTURE TO BE REMOVED.

EXISTING HVAC CONTROL BOX TO BE RELOCATED.

EXISTING TOILET PARTITIONS TO BE REMOVED.

EXISTING COLUMN TO REMAIN. PROTECT IN PLACE.

EXISTING WALL MOUNT SHELVES TO BE REMOVED.

REPLACE THE ACCESS CONTROL WITH NEW SYSTEM PER CLIENT REQUIREMENTS.

EXISTING DISPLAY TO BE REMOVED.

EXISTING DRINKING FOUNTAIN TO BE REMOVED.

THE DOOR CLOSER NEED TO BE ADJUSTED TO COMPLY WITH MAXIMUM ALLOWABLE OPENING FORCE, TYP. WHERE (E) DOORS REMAIN.

ALL HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS & GATES SHALL COMPLY WITH 2022 CBC STANDARDS.

ALL RECEPTACLES AND SWITCHES SHALL POSITIONED CORRECTLY TO COMPLY WITH 2022 CBC STANDARDS.

THE GEOMETRIC SYMBOL FOR THE WOMEN'S ROOM SHOULD BE RELOCATED TO COMPLY WITHIN ALLOWABLE HEIGHT RANGE.

ALL THE ROOM DESIGNATION SIGNS TO BE REMOVED AND TO BE REPLACE WITH RAISED CHARACTERS.

EXISTING DOOR TO BE REMOVED, FRAME TO REMAIN.

EXISTING GLAZING (BOOK DROP ) TO BE REMOVED.

REMOVE ALL VINYL WALL COVERING, SKIM COAT AND PAINT WALLS.

EXISTING MASONRY WALL

EXISTING DATA CABINET TO BE RELOCATED TO IT ROOM (#10).

EXISTING GATE TO BE REMOVED AND THE EXISTING WALL PATCH & REPAIR.

EXISTING HANDRAILS TO BE REMOVED AND REPLACE WITH ADA COMPLIANT

HANDRAIL.

EXISTING ELECTRICAL PANEL TO REMAIN.

EXISTING ELECTRICAL SWITCHGEAR TO BE REPLACED.

EXISTING BOILER TO BE RELOCATED.

EXISTING STOREFRONT SYSTEM TO BE REMOVED.

REMOVE WOOD SIDING ON COLUMNS, TYPICAL.

-0

1-

DN.

BLR

BLR

S

S S S

S S

S

S S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

VARIES

9'-11"

VARIES

8'-0"

8'-0"

10'-0"

10'-0"

10'-0" 10'-0" 10'-0"

9'-11"

10'-0"

8'-0"

8'-0" 9'-11"

8'-0" 8'-0"

10'-0"

11'-0"

11'-0"

11'-0" 11'-0" 11'-0" 11'-0"

SD

SD

SD

SD

H

SD

SD

SD

SD

S

S

S

S

S

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

D

E M

O L I T

I O

N

R

E F

L E

C T

I L I N

G

P

L

O

T

D

A T

E

E

R

S

H E

L L E

Y S

I V

A K

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

DEMOLITION REFLECTED CEILING PLAN

D E

F

L E

C T

I L I N

G

P

L A

N

A-112

N

LEGENDGENERAL NOTES

ADD ½” DRYWALL OVER EXISTING GLUE ON ACOUSTICAL CEILING TILES. ADD ALTERNATE TO

REMOVE/ABATE TILES FIRST IF THEY CONTAIN ASBESTOS.

REMOVE ALL INTERIOR LIGHTING AND EXIT SIGNS.

REMOVE ALL WALL MOUNTED LIGHT FIXTURES.

REMOVE THE T-BAR GRID AND TILES AND FALLEN BATT INSULATION THAT IS NOT ABLE TO BE

REATTACHED THROUGHOUT THE LIBRARY, COMMUNITY ROOM AND FRIENDS OF LIBRARY AREA.

EXISTING GLU. LAM. BEAMS TO REMAIN.

PROTECT EXTERIOR SOFFIT IN PLACE AND PREPARE TO RECEIVE PAINT & EXTERIOR SURFACE

MOUNTED LIGHT FIXTURE TO BE REPLACED WITH LED LIGHT.

SUPPLY AND RETURN DIFFUSERS AND EXISTING DUCTWORK THROUGHOUT THE LIBRARY WILL

COORDINATE WITH MECHANICAL DESIGN. ALL DIFFUSERS WILL BE REPLACED WITH TITUS OMNI

STYLE U.N.O.

REMOVE T&G WOOD CEILING TREATMENT

TYP. CEILING GRID AND A.C.T. TO BE REMOVED

1. FIELD VERIFY ALL EXISTING CONDITIONS & IDENTIFY EXACT SCOPE OF WORK PRIOR

REMOVAL STARTS. CONTACT ARCHITECT & CLIENT IF THERE ARE ANY DISCREPANCIES.

2. THE GENERAL CONTRACTOR SHALL COORDINATE ANY DEMOLITION OF HVAC/MECHANICAL,

AND ELECTRICAL SCOPE OF WORK WITH ENGINEERS DRAWINGS.

3. THE GENERAL CONTRACTOR MUST ALLOW FOR ADDITIONAL DEMOLITION THAT MAY NOT BE

SHOWN, BUT MAY BE REQUIRED TO ACHIEVE THE FINISHED RESULT, AS SHOWN ON THE

DRAWINGS.

4. PRIOR TO START OF DEMOLITION WORK, GENERAL CONTRACTOR SHALL PROVIDE A

PROTECTIVE BARRIER PER CLIENT AND LOCAL CITY REQUIREMENTS.

5. ALL EXISTING WORK TO REMAIN, UNLESS OTHERWISE NOTED.ALL DEMOLITION WORK SHALL

BE IN ACCORDANCE WITH THE CALIFORNIA FIRE CODE 2019 EDITION, SECTION 33.

6. ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE,

2019 EDITION, CHAPTER 33.

7. THE CONTRACTOR SHALL RESTORE TO ITS ORIGINAL CONDITION ANY EXISTING WORK

DAMAGED DURING DEMOLITION BUT INDICATED TO REMAIN.

8. ALL DIFFUSERS & RETURN GRILLES SHALL BE COVERED PRIOR TO ANY WORK. COORDINATE

WITH BUILDING ENGINEER & CLIENT.

9. REMOVE ALL DEBRIS. NO DEBRIS SHALL BE LEFT OR REMAIN DURING CONSTRUCTION.

TRASH REMOVAL IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.

TYP.

TYP.

TYP.

TYP.

TYP.

3 3

2'X4' LED FIXTURE

EXISTING GYPSUM BOARD CEILING

EXISTING WOOD PANEL CEILING

1 1

-0

1-

INFORMATION

FRIENDS

OF

LIBRARY

FRIENDS

OF

LIBRARY

MEN

CONMUNITY ROOM

COURTYARD

STAFF

BATHROOM

IT

ROOM

MECH

WOMEN

LOBBY

STORAGE

JANITOR

STUDY

ROOM

LIBRARIAN

STAFF

LOUNGE

STUDY

ROOM

STUDY

ROOM

WORK

ROOM

D

F

CHILDREN READING AREA

PRINTER

SELF CHECK-OUT

COMMON AREA

ADULT READING AREA

TEEN READING AREA

LAPTOPS

TEEN READING AREA

PC RES OPAC

B O

O K

D R

O P

T V

L O

W

S

H E

L V

I N

G

CHILDREN SEATING AREA &

MOBILE SHELVING

STORAGE

M W

RAISED GARDEN

DN.

A/C

TRASH

ENCLOSURE

BLR

H

R

R

E F

U G

E

A

R E

A

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

F

L O

O

T

D

A T

E

E

R

S

H E

L L E

Y S

I V

A K

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

FLOOR PLAN

F L O

A

N

A-211

N

LEGENDGENERAL NOTES

NEW INTERIOR PARTITION.

NEW GLAZING.

NEW INTERIOR DOOR, SOLID WOOD, HM FRAME, PRIME/PAINT AND NEW HARDWARE.

EXISTING EXTERIOR GLAZING SYSTEM TO REMAIN.

PROVIDE BACKING FOR CONNECTION OF CASEWORK, FURNITURE, TV, WALL MOUNTED SHELVES.

NEW HI-LOW' DRINKING FOUNTAIN WITH BOTTLE FILLER.

NEW CARPET TILE THROUGHOUT, SEE FINISH PLAN.

CANTILEVERED SOLID SURFACE COUNTERS.

RELOCATE FLOOR OUTLETS WITH FLUSH TYPE DEEP BOXES AS REQUIRED.

ALL EXISTING COLUMNS AND INTERIOR WALLS TO RECEIVE NEW PAINT.

NEW TACTILE EXIT SIGNAGE PER CBC SECTION 1011.4.

NEW MAXIMUM OCCUPANCY SIGN.

NEW RECEPTION DESK. (USE EXISTING ELECTRICAL CONNECTIONS IF POSSIBLE)

NEW BOOK SHELVES.

1. SEE ACCESSIBILITY SHEETS FOR ADDITIONAL NOTES AND DIMENSIONS, TYP.

2. ALL DIMENSIONS ARE FROM FACE OF FINISH U.N.O

3. ALL EXISTING CONDITIONS SHALL BE VERIFIED IN FIELD PRIOR TO STARTING THE PROJECT.

4. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, ELECTRICAL OR

5. MECHANICAL DRAWINGS AND OBTAIN CLARIFICATION BEFORE COMMENCING WITH WORK.

6. WHERE ELECTRICAL WORK IS SPECIFIED IN CONJUNCTION WITH CABINET WORK, LAMPS AND

FIXTURES SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. CUT-OUTS FOR SWITCHES,

OUTLETS AS REQUIRED BY THE CABINET CONTRACTOR, SHALL BE COORDINATED WITH THE

ELECTRICAL CONTRACTOR, U.N.O.

7. GANG SWITCHES UNDER ONE COVER PLATE WHENEVER POSSIBLE.

8. LOCATION AND CLASSIFICATION OF FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE W/ CCR TITLE

19. A MINIMUM OF ONE 2A-10BC SHALL BE PROVIDED, APPROVED BY THE FIRE INSPECTOR.

31 31 31

NEW PLUMBING FIXTURES AND ACCESSORIES.

NEW RESTROOM PARTITIONS.

NEW RESTROOM DOOR SIGN.

NEW CABINETS, COUNTERTOP, SINK.

NEW FULL SIZE REFRIGERATOR.

NEW BUILT-IN MICROWAVE.

NEW CUSTOM MILLWORK LOCKERS 2 ROWS HIGH @42" A.F.F.

NEW BOILER LOCATION, WITH NEW SCREEN FENCE.

NEW PORCELAIN WALL AND FLOOR TILE IN RESTROOMS.

NEW ADA COMPLIANT HANDRAIL.

NEW DOOR WITH ADA COMPLIANT VISION LITE IN EXISTING FRAME .

EXISTING DOOR & FRAME TO RECEIVE PAINT AND HARDWARE.

UPGRADE EXISTING ADJACENT WALLS TO COMPLY WITH REQUIRED

FIRE RATING CODE FOR SEPARATION OF ELECTRICAL SWITCHGEAR.

NEW 2 HR FIRE RATED STOREFRONT/ WALL UP TO STRUCTURE.

DENOTES DOOR NUMBER. REFER TO DOOR SCHEDULE/

DOOR TYPES, SHEET A-602.

A

WALL TYPE, REFER

TO WALL LEGEND

DENOTES WINDOW NUMBER. REFER TO WINDOW

SCHEDULE, SHEET A-603.

FIRE EXTINGUISHER BY OVAL OR EQUAL LOW PROFILE

ALIGN FINISHES.

FE

EXISTING INTERIOR WALL

NEW WALL

NEW LOW SLUMP STONE WALL

FLOOR OUTLET, REFER TO ELECTRICAL DRAWINGS

EXISTING DOOR

NEW DOOR

EXISTING MASONRY WALL

EXISTING GLAZED AUTOMATIC DOORS TO REMAIN.

WRAP COLUMNS IN GYP. BOARD REPLACE FURRING AS NECESSARY.TYP.

NEW INTERIOR STOREFRONT WALL AND DOOR

NEW CLOSET WITH CODE COMPLIANT ROOF ACCESS LADDER AND HATCH.

-0

1-

DN.

BLR

BLR

S

VARIES

9'-11"

VARIES

8'-0"

8'-0"

10'-0"

10'-0"

10'-0" 10'-0" 10'-0"

9'-11"

10'-0"

8'-0"

8'-0" 9'-11"

8'-0" 8'-0"

10'-0"

11'-0"

11'-0"

11'-0" 11'-0" 11'-0" 11'-0"

S

S

S

S

S

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

P

R O

P O

S E

D

R

E F

L E

C T

I L I N

G

P

L

O

T

D

A T

E

E

R

S

H E

L L E

Y S

I V

A K

A E

D L

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

REFLECTED CEILING PLAN

R E

F L E

C T

I L I N

G

P

L A

N

A-212

N

LEGENDGENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS & IDENTIFY EXACT SCOPE OF WORK PRIOR

REMOVAL STARTS. CONTACT ARCHITECT & CLIENT IF THERE ARE ANY DISCREPANCIES.

2. THE GENERAL CONTRACTOR SHALL COORDINATE ANY DEMOLITION OF HVAC/MECHANICAL,

AND ELECTRICAL SCOPE OF WORK WITH ENGINEERS DRAWINGS.

3. THE GENERAL CONTRACTOR MUST ALLOW FOR ADDITIONAL DEMOLITION THAT MAY NOT BE

SHOWN, BUT MAY BE REQUIRED TO ACHIEVE THE FINISHED RESULT, AS SHOWN ON THE

DRAWINGS.

4. PRIOR TO START OF DEMOLITION WORK, GENERAL CONTRACTOR SHALL PROVIDE A

PROTECTIVE BARRIER PER CLIENT AND LOCAL CITY REQUIREMENTS.

5. ALL EXISTING WORK TO REMAIN, UNLESS OTHERWISE NOTED.ALL DEMOLITION WORK SHALL

BE IN ACCORDANCE WITH THE CALIFORNIA FIRE CODE 2019 EDITION, SECTION 33.

6. ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE,

2019 EDITION, CHAPTER 33.

7. THE CONTRACTOR SHALL RESTORE TO ITS ORIGINAL CONDITION ANY EXISTING WORK

DAMAGED DURING DEMOLITION BUT INDICATED TO REMAIN.

8. ALL DIFFUSERS & RETURN GRILLES SHALL BE COVERED PRIOR TO ANY WORK. COORDINATE

WITH BUILDING ENGINEER & CLIENT.

9. REMOVE ALL DEBRIS. NO DEBRIS SHALL BE LEFT OR REMAIN DURING CONSTRUCTION.

TRASH REMOVAL IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.

2'X4' ACOUSTICAL T-BAR

REPLACE THE T-BAR GRID AND TILES THROUGHOUT THE LIBRARY, COMMUNITY ROOM AND FRIENDS

OF LIBRARY AREA.INSTALL NEW R-30 BATT INSULATION BETWEEN RAFTERS THROUGHOUT.

FURR OUT FOR NEW DRYWALL AT THE UNDERSIDE OF THE MECHANICAL MEZZANINE AND

INCORPORATE DECORATIVE LIGHTING.

ADD ½” DRYWALL OVER EXISTING GLUE ON ACOUSTICAL CEILING TILES. ADD ALTERNATE TO

REMOVE/ABATE TILES FIRST IF THEY CONTAIN ASBESTOS.

NEW GYPSUM BOARD CEILING, PAINT.

ADD NEW LED LINEAR PENDANT FIXTURES ABOVE STACKS AND OTHER SELECTED AREAS.

NEW TITUS OMNI HVAC DIFFUSERS THROUGHOUT.

NEW 2X4 LED LIGHT FIXTURE.

EXISTING ACCESS PANEL TO REMAIN.

NEW EXTERIOR SURFACE MOUNTED LED LIGHT FIXTURE.

NEW DECORATIVE SURFACE MOUNTED LIGHT FIXTURE

N

2'X4' LED FIXTURE

EXISTING GYP. CEILING

NEW GYP. CEILING

2 2

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

6" LED CAN LIGHT

24" CAMMAN LED LIGHTING

18" CAMMAN LED LIGHTING

LINEAR LED LIGHTING

SPI LIGHTING ZYNN 2" LINES

SURFACE MOUNTED LIGHT FIXTURE

LIGHT FIXTURE SCHEDULE

-0

1-

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

R

O O

F

P

L

O

T

D

A T

E

E

R

M

A H

S A

J A

V A

H E

R I A

N

A E

D L

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

ROOF PLAN

R O

A

N

A-213

N

REMOVE CLAY ROOF TILES AND REPLACE WITH CRRC CODE APPROVED ASPHALT SHINGLES AND WEATHER

BARRIER. INCLUDE CONTINUOUS INSULATION ABOVE THE ROOF AND NEW BATT INSULATION BELOW. ALLOW FOR

REPLACEMENT OF 20% OF THE ROOF SHEATHING AND BATT INSULATION.

REPLACE ROOF SEALANT THROUGHOUT.

REPAIR MECHANICAL WELL ROOFING AS REQUIRED.

REPLACE GUTTER, FLASHING AND DOWNSPOUTS AT ROOF PERIMETER, FACTORY FINISH, COLOR PER OWNER.

ANCHOR ROOF TOP MECHANICAL UNITS AS REQUIRED, TYPICAL.

CODE COMPLIANT ROOF ACCESS HATCH AND LADDER

PATCH AND REPAIR AREA OF OLD ACCESS HATCH.

-0

1-

KEY NOTES

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

E

X T

E R

I O

R

E

L E

V A

T I O

O

T

D

A T

E

E

R

S

H E

L L E

Y S

I V

A K

A E

D L

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

EAST ELEVATION

E X

T E

R I O

R

E

L E

V A

T I O

N S

A-114

REPAIR ALL EXTERIOR WALL STUCCO CRACKS & FINISH TO MATCH EXISTING.

NEW GLAZING.

REMOVE CLAY ROOF TILES AND REPLACE WITH CRRC CODE APPROVED ASPHALT

SHINGLES AND WEATHER BARRIER. INCLUDE CONTINUOUS INSULATION ABOVE THE

ROOF AND NEW BATT INSULATION BELOW. ALLOW FOR REPLACEMENT OF 20% OF

THE ROOF SHEATHING AND BATT INSULATION.

REPLACE SHEET METAL GUTTERS AND DOWNSPOUTS, FACTORY FINISH COLOR TBD.

NEW 2-HOUR FIRE RATED DOORS, STOREFRONT AND GLAZING

1/8" = 1'-0"

WEST ELEVATION

1/8" = 1'-0"

NORTH ELEVATION

1/8" = 1'-0"

SOUTH ELEVATION

-0

1-

INFORMATION

FRIENDS

OF

LIBRARY

FRIENDS

OF

LIBRARY

MEN

CONMUNITY ROOM

COURTYARD

STAFF

BATHROOM

IT

ROOM

MECH

WOMEN

LOBBY

STORAGE

JANITOR

STUDY

ROOM

LIBRARIAN

STAFF

LOUNGE

STUDY

ROOM

STUDY

ROOM

WORK

ROOM

D

F

CHILDREN READING AREA

PRINTER

SELF CHECK-OUT

COMMON AREA

ADULT READING AREA

TEEN READING AREA

LAPTOPS

TEEN READING AREA

PC RES OPAC

B O

O K

D R

O P

T V

L O

W

S

H E

L V

I N

G

CHILDREN SEATING AREA &

MOBILE SHELVING

STORAGE

M W

RAISED GARDEN

DN.

A/C

TRASH

ENCLOSURE

BLR

BLR

H

R

R

E F

U G

E

A

R E

A

COUNTY APPROVAL STAMP

Sheet

C o un ty o f

O ra ng e

O C

F ac ili tie s D es ig n

C o ns tr uc tio n

PU

B

LI

C

W O R K S

S h t Ti tle

P ro je ct

A

-E

D es ig n

C h kd

D at e P

R O

J.

N

S ea l

C o ns ul ta nt s

D ra w n

C h kd

D at e

R ev is io ns

D es cr ip

B y D at e

S ym

Plan No.

P

E T

E R

S

C

A N

Y O

N

R

O A

D

S

U I T

E

I R

V I N

E

C

A

T E

L

X

I D

S

P r o j e c t

X

I D

S

I D

S

G

R O

U P

LA

H

AB

RA

LI

BR

AR

Y

RE

FR

ES

H

OC

PW

9-

2-

9-

PL

-1

I D

S

G

R O

I

C A

T I O

N

S

P

R O

J E

C T

S S

H A

R E

D X

O

C P

W

B

B

R A

F

R E

S H

C

A D

A

R C

H X

A

F

I N

I S

H

F

L O

O

T

D

A T

E

E

R

S

H E

L L

E Y

S

I V

A K

M

J S

S

S

D

S

B

M I T

T A

L

1 E

LA

H

AB

RA

B

LV

D, LA

H

AB

RA

, C

A

1/8" = 1'-0"

FINISH FLOOR PLAN

F I N

I S

H

F

L O

A

N

A-221

N

LEGEND

C4

VENDOR: KINETEX

ITEM: MAJOR METRO

COLOR: 3405 URBANE

C5

VENDOR: KINETEX

ITEM: MAJOR METRO

COLOR: T.B.D.

PT1 FLOOR TILE

VENDOR: DALTILE

ITEM: VOLUME 1.0

COLOR: VL71 DEGREES SILVER

SIZE: 12"X24"

GROUT: T.B.D.

C1 GRAY COMBO

SHAW CONTRACT

LIVING SYSTEMS

TRANSFORM TILE

5T308-56760

CALL FOR AVAILABILITY!

C2 MULTI-COLOR CARPET

SHAW CONTRACT

LIVING SYSTEMS

TRANSFORM COLOR TILE

5T311-05865

C3 SOLID

SHAW CONTRACT

LIVING SYSTEMS

ENDLESS TILE

5T305-05868

PT2 RESTROOM WALL TILE AND COVED BASE

VENDOR: DALTILE

ITEM: HARMONIST

COLOR: AMITY HM32

SIZE: 12"X24" BULLNOSE TOP & CORNERS

FINISH: MATTE

GROUT: T.B.D.

CT1 BREAK ROOM WALL TILE

VENDOR: DALTILE

ITEM: COLOR WHEEL CLASSIC

COLOR: 0190 ARCTIC WHITE

SIZE: 3"X6"

FINISH: MATTE

GROUT; CUSTOM 381 BRIGHT WHITE,

B1 TOELESS WALL BASE

VENDOR: TARKETT/JOHNSONITE

ITEM: VINYL 080"

COLOR: 63 BURNED UMBER

SIZE: 4" TOELESS AT CARPET TILE

LENGTH: COIL/CONTINUOUS ROLL

B2 TOE WALL BASE

VENDOR: TARKETT/JOHNSONITE

ITEM: VINYL 080"

COLOR: 63 BURNED UMBER

SIZE: 4" TOE AT KINETEX

LENGTH: COIL/CONTINUOUS ROLL

-0

1-

Sheets and Views
22X085-06_G-001 PROJECT INFORMATION & DRAWING INDEX-G-001
22X085-06_G-008- EGRESS FLOOR PLAN-G-008
22X085-06_A-011- SITE PLAN-A-011
22X085-06_A-111-DEMOLITION FLOOR PLAN-A-211
22X085-06_A-112- DEMOLITION REFLECTED CEILING PLAN-A-112
22X085-06_A-211- FLOOR PLAN-A-211
22X085-06_A-212- PROPOSED REFLECTED CEILING PLAN-A-212
22X085-06_A-213- ROOF PLAN-A-213
22X085-06_A-114- EXTERIOR ELEVATIONS-A-114
22X085-06_A-221- FINISH FLOOR PLAN-A-221

File details come from the government source that posted it. Updated .