La_Habra_Library_SD_Set.pdf
PDF 9 MB Posted
- Attached to
- CONSTRUCTION MANAGER AT RISK (CMAR) FOR THE GARDEN GROVE MAIN LIBRARY & LA HABRA LIBRARY REMODEL PROJECT
- Solicitation number
- CMAR-RFP-080-2603601-JM
- Issued by
- Orange County, San Francisco City, California
About this file
The document is a Schematic Design (SD) Set for the La Habra Library Refresh project, prepared by IDS Group for OC Public Works in Orange County, California. The project involves a tenant improvement of the existing library located at 221 E La Habra Blvd, with the goal of continuing and improving the public facility's use. The library is a single-story, Type III-N construction, with no change to the existing building area or number of stories. The design sets include comprehensive floor plans, demolition plans, reflected ceiling plans, roof plans, and exterior elevations, detailing proposed renovations such as new flooring, lighting, wall treatments, and strategic space reconfigurations. The project will involve removing and replacing existing elements like roof tiles, ceiling tiles, electrical fixtures, and updating various interior spaces including reading areas, staff spaces, and mechanical rooms.
The design documents indicate a detailed approach to modernizing the library while maintaining its current footprint, with careful attention to California Building Code (2022 edition) compliance. The total occupant load is calculated at 265 people, with spaces designated for various functions including office, reading, assembly, and storage areas. The project includes specific finish selections like Kinetex carpet tiles, Daltile floor and wall tiles, and Shaw Contract carpet tiles, suggesting a comprehensive aesthetic and functional upgrade. The design also addresses accessibility requirements, with plans for ADA-compliant features such as handrails, door hardware, and signage. While the documents do not specify exact budget or funding sources, they represent a thorough schematic design phase for a significant public facility renovation project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET # SHEET NAME
PROJECT INFORMATION & DRAWING INDEX
GENERAL NOTES
G-001
G-002
CAL GREEN GENERAL NOTES
G-003
CAL GREEN GENERAL NOTES
G-004
CAL GREEN GENERAL NOTES
G-006
GENERAL
ACCESSIBILITY COMPLIANCE NOTES & DETAILS
G-006
G-007
NUMBER OF SHEETS
X
G E
N E
R A
L
N
O T
E S
D
R A
W I N
G
I N
D E
X
G-001
601 N. ROSS STREET, SANTA ANA, CA 92701
OC PUBLIC WORKS / OC FACILITIES DESIGN & CONSTRUCTION
A&E PROJECT MANAGEMENT SECTION
VICINITY MAP
SITE MAP / FACILITY MAP
BOARD OF SUPERVISORS
C O
U N
YT
OF O RA
N G
E
C
A L I F O RN
IA
COUNTY APPROVAL STAMP
JAMES TREADAWAY, PE, SE, DIRECTOR
SANTA ANA, CALIFORNIA
PublicWorks
OC FACILITIES DESIGN &
CONSTRUCTION
OC PUBLIC WORKS
Approve in Concept
Date:
Section Manager:
Project Manager:
Plan No.
Sheet
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
O
R ev is io ns
S ym
D es cr ip
B y
D at e
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n A
-E S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
County Project Manager:
Name Title Date
Client Staff & Representatives:
CLIENT NAME
CLIENT DEPARTMENT
Address
Title:
Name:
Address:
Title:
Name:
Address:
Phone:
Title:
Name:
Address:
Phone:
Title:
Name:
Address:
Phone:
Client Approvals:
Name Title Date Name Title Date
Name: Matthew DeHart
Address: 601 N. Ross Street, 4th Floor, Santa Ana,CA 92701
Phone: 714-667-4972
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
F
A X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
I D
S
G
R O
U P
I L E
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
H
B
I B
R A
Y
F
R E
S H
C
A D
A
R C
H X
G
P
R O
J E
C T
N
F O
R M
A T
I O
D
A
W I N
G
I N
D
X
O
T
D
A T
E
M
S E
R
M
A H
S A
J A
V A
H E
R I A
N
LA HABRA LIBRARY REFRESH
DRAWING INDEX
Matthew DeHart 601 N. Ross Street, 4th Floor, Santa Ana,CA 92701
Senior Project Manager, OC Public Works
ANDREW DO, VICE-CHAIRMAN
CHAIRMAN
DOUG CHAFFEE,
VICENTE SARMIENTO
DONALD P. WAGNER,
SECOND DISTRICT
FIRST DISTRICT
FIFTH DISTRICTKATRINA FOLEY,
FOURTH DISTRICT
B
M I T
T A
L
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
OC
PW
9-
2-
9-
PL
-1
221 E LA HABRA BLVD, LA HABRA, CA 90631
M
J S
S
CODE REFERENCES
PROJECT INFORMATION
DESIGN TEAM
DEFERRED SUBMITTALS
1.FIRE ALARM
2.FIRE SPRINKLER
3.OCFA APPROVALS
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC)
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA ELECTRICAL CODE (CEC)
2022 CALIFORNIA MECHANICAL CODE (CMC)
2022 CALIFORNIA PLUMBING CODE (CPC)
2022 CALIFORNIA FIRE CODE (CFC)
2022 CALIFORNIA ENERGY CODE
2010 ADA STANDARDS
CONTRACTOR'S NATIONAL ASSOCIATION (SMACNA)
AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)
AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME)
PROJECT MANAGER:
SHELLEY SIVAK
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606
PHONE: 949-387-8500 EXT 188
EMAIL: SHELLEY.SIVAK@IDSGI.COM
STRUCTURAL ENGINEER:
SAID HILMY, PhD, SE
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606 PHONE:
949-387-8500 EXT 116
ELECTRICAL ENGINEER:
STEVEN COLLINS
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606 PHONE:
949-387-8500 EXT 325
ARCHITECT OF RECORD:
JOHN SILBER, AIA
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606
PHONE: 949-387-8500 EXT 157
MECHANICAL ENGINEER:
DARREN SMITH
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606
PHONE: 949-387-8500 EXT 454
PLUMBING ENGINEER:
DARREN SMITH
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606
PHONE: 949-387-8500 EXT 454
SCOPE OF WORK:
THE TENANT IMPROVEMENT OF THE EXISTING LIBRARY FOR A CONTINUED
AND IMPROVED USE OF THE PUBLIC FACILITY. THE BUILDING IS LOCATED
ON THE LA HABRA BLVD IN CITY OF LA HABRA, COUNTY OF ORANGE,
STATE OF CALIFORNIA.
OCCUPANCY TYPE: A-3
CONSTRUCTION TYPE: III-N
FIRE SPRINKLERS: NO
NUMBER OF STORIES: NO CHANGE - 1 STORY
BUILDING AREA: NO CHANGE - EXISTING
PROJECT
LOCATION
PROJECT
LOCATION
a.
b.
c.
d.
e.
f.
g.
GENERAL
THESE PLANS ARE THE PROPERTY OF IDS GROUP INC., AND ARE NOT TO BE USED FOR ANY OTHER THAN THE LOCATION
SHOWN HEREON.
1. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE AND CONSENT OF THE ARCHITECT OR
ENGINEER WHOSE SIGNATURE APPEARS HEREON.
2. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF CONCRETE MASONRY UNITS, CENTERLINE OF COLUMNS AND BEAMS, OR FACE OF STUDS, UNLESS OTHERWISE NOTED. FINISH FLOOR ELEVATIONS
ARE TO TOP OF CONCRETE SLAB OR TOP OF INTERIOR PAVING UNLESS OTHERWISE NOTED.
3. ALL LEVELS REFERENCE POINTS ARE TAKEN FROM TOP OF SHEATHING OR TOP OF CONC. SLAB/COMBO DECKING.
DIMENSIONS ON ELEVATIONS, SECTIONS AND WALL SECTIONS ARE REFERENCED TO THESE POINTS, UNLESS NOTED.
4. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL. REQUEST FOR SUBSTITUTIONS SHALL
BE IN ACCORDANCE WITH THE SPECIFICATIONS OF SHEETS G-901,902 , 903 AND ETC.
THESE DRAWINGS DO NOT CONTAIN THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY.
ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE STATE CONSTRUCTION SAFETY ORDERS
ENFORCED BY THE STATE DIVISION OF INDUSTRIAL SAFETY.
CODES
CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA BUILDING CODE, ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS GOVERNING THE
WORK. IN CASE OF CONFLICTS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN.
PERMIT
1. THE CONSTRUCTION OR DEMOLITION OF ANY BUILDING, STRUCTURE,USING SCAFFOLDING OR FALSEWORK MORE THAN 3 STORIES OR 36'-0" IN HEIGHT, REQUIRES A PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL
SAFETY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ( 1PC.B.9 )
2. A PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS IS REQUIRED FOR A PROTECTION FENCE OR CANOPY ON OR OVER ANY STREET OR PUBLIC SPACE. PROTECTION OF PEDESTRIANS DURING CONSTRUCTION SHALL BE PROVIDED PER
C.B.C. SECTION 3303.
3. ALL ROOMS ARE REQUIRED TO BE MARKED WITH APPROVED SIGNAGE.
4. OBTAIN PERMIT FROM CITY ENGINEER PRIOR TO DOING ANY SIDEWALK AND CURB WORK.
5. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. REFER TO SHEET G-001 FOR LIST OF DEFERRED SUBMITTALS.
METAL WORK
1. ALL METAL FRAMING MEMBERS SHALL BE ARRANGED AND SPACED AS TO PERMIT INSTALLATION OF PIPE CONDUITS AND DUCTWORK WITH A MINIMUM OF CUTTING. SHAFT WALLS SHALL BE PROVIDED WITH NECESSARY FRAMES, BRACING, AND SEALANT AROUND THE OPENING.
2. CONTACT BETWEEN DISSIMILAR METAL SHALL BE PROTECTED.
WOOD WORK INCLUDING METAL STUDS
1. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE FLUSH. IF STRUCTURAL PANELS ARE REQUIRED ON A WALL PLANE, THE ENTIRE WALL PLANE SHALL BE FURRED OR FINISHED FLUSH.
2. INSTALL METAL CORNER BEADS AT ALL EXPOSED WALLBOARD EDGES. INSTALL CASING BEADS WHEREVER WALLBOARD, PLASTER, ETC. ABUTS A DISSIMILAR FINISH MATERIAL AND PROVIDE SEALANT AS REQUIRED.
3. GYPSUM BOARD SHALL EXTEND TO UNDERSIDE OF STRUCTURE ABOVE AT ALL EXTERIOR PERIMETER WALLS
DOORS
1. DOORS IN RATED WALLS SHALL CONSIST OF SELF-CLOSING, SELF-LATCHING ASSEMBLIES WITH SMOKE AND DRAFT SEALS AT HEAD AND JAMBS. DOOR ASSEMBLY RATINGS SHALL BE AS INDICATED ON DOOR SCHEDULE. HOLD OPEN DEVICES ON RATED ASSEMBLIES SHALL BE MAGNETICALLY OPERATED AND ACTIVIATED BY SMOKE DETECTORS.
2. DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR THRESHOLDS, ECT., SHALL BE TAKEN OFF THE DOOR. DOORS AND FRAMES SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS, AND
HARDWARE.
3. AIR LEAKAGE AT EXTERIOR DOORS SHALL BE LIMITED BY THE FOLLOWING:
ALL DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE AT THE HEAD AND SILL.
DOORS MOUNTED ON EITHER THE INSIDE OR OUTSIDE OF AN EXTERIOR WALL SHALL HAVE A MINIMUM 1/2" LAP AT
EACH JAMB.
DOORS REQUIRING VERTICAL TRACK OR GUIDES SHALL USE A CONTINUOUS MOUNTING ANGLE, SEALED IN
ACCORDANCE WITH "G" LISTED HERE.
DOORS MOUNTED BETWEEN THE JAMBS SHALL HAVE A CONTINUOUS SEAL OR BAFFLE AT EACH JAMB.
MEETING RAILS OR SECTION DOORS AND MEETING STILES OR RAILS OR BI-PARTING DOORS SHALL BE PROVIDED
WITH A SEAL, ASTRAGAL, OR BAFFLE.
SWINGING DOORS SHALL BE WEATHERSTRIPPED AT THE HEAD, SILL AND JAMBS.
OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALL AND FOUNDATIONS, BETWEEN WALL AND ROOF, BETWEEN WALL PANELS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND ROOFS AND ALL OTHER OPENINGS IN THE EXTERIOR ENVELOPE SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO CREATE AN AIRTIGHT ASSEMBLY.
ACCESSIBILE FIXTURES & SIGNAGE
N
N
G-008
EGRESS FLOOR PLAN
A-111
DEMOLITION FLOOR PLAN
A-211
FLOOR PLAN
-0
1-
BUSINESS - OFFICE
ASSEMBLY-UNCONCENTRADED- CHAIRS
& TABLES
STORAGE-MECHANICAL ROOM
READING ROOMS
STACKS
NO OCCUPANTS
M
A
X
V
E
R
A
A
G
O
N
A
L
INFORMATION
CORRIDOR
FRIENDS
OF
LIBRARY
FRIENDS
OF
LIBRARY
MEN
CONMUNITY ROOM
COURTYARD
STAFF
BATHROOM
IT
ROOM
MECH
WOMEN
LOBBY
STORAGE
JANITOR
STUDY
ROOM
LIBRARIAN
STAFF
LOUNGE
STUDY
ROOM
STUDY
ROOM
WORK
ROOM
D
F
CHILDREN READING AREA
PRINTER
SELF CHECK-OUT
COMMON AREA
ADULT READING AREA
TEEN READING AREA
LAPTOPS
TEEN READING AREA
PC RES OPAC
B O
O K
D R
O P
T V
L O
W
S
H E
L V
I N
G
CHILDREN SEATING AREA &
MOBILE SHELVING
STORAGE
M W
RAISED GARDEN
DN.
A/C
TRASH
ENCLOSURE
BLR
BLR
H
R
R
E F
U G
E
A
R E
A
EXIT / TRAVEL DISTANCE =85'
EXIT 1
EXIT 2
EXIT 3
EXIT 4
EXIT 5
LIFE & SAFETY BUILDING CODE SUMMARY CODE ANALYSIS
INTERIOR TENANT IMPROVEMENTS FOR AN OFFICE FACILITY
WHICH IS SUBMITTED AS A "B" OCCUPANCY, PER 2022 CBC -
CHAPTER 3, SECTION 304.1
2022 CBC - CHAPTER 10:
THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE
ILLUMINATED AT ALL TIMES THAT THE ROOM OR SPACE IS
OCCUPIED. (CBC-1008.2)
THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT
LESS THAN 1-FOOT CANDLE (11 LUX) AT THE WALKING SURFACE
LEVEL.
THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION
SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL
SUPPLY (CBC 1008.3).
THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR
THE DURATION OF NOT LESS THAN 90 MINUTES AND SHALL
CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN
ON-SITE GENERATOR. (CBC 1008.3.4)
PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN
LOCATIONS NOTED ON CFC 906.1.
EGRESS ANALYSIS:
-EXITS REQUIRED:
OCCUPANT LOAD: 265 OCC
OCCUPANCY: A-3
EXITS REQUIRED (CBC TABLE 1006.3.3): 2
EXITS PROVIDED: 5
-EXITS SEPARATION (WITOHUT SPRINKLER SYSTEM):
-NUMBER OF EXITS PROVIDED: 5
-LONGEST DIAGONAL OF OCCUPIED SPACE: 229'-0"
-REQUIRED SEPARATION OF EXITS: 229'/2=114.5'
-EGRESS COMPONENT WIDTH REQUIRED (CBC 1005.3.2)
DOORWAYS:265 OCC/ 5 EXITS = 53 OCC PER EXIT (0.2)= 10.6"
PROVIDED: (PROVIDED: 36" MIN)
EXIT 1 = 3'-9" OCC. DISCHARGE = 53
EXIT 2 = 3'-9" OCC. DISCHARGE = 53
EXIT 3 = 3'-0" OCC. DISCHARGE = 53
EXIT 4 = 3'-0" OCC. DISCHARGE = 53
EXIT 5 = 6'-0" OCC. DISCHARGE = 53
-MAXIMUM TRAVEL DISTANCE TO EXITS (WITHOUT AUTOMATIC SPRINKLER SYSTEM THROUGHOUT
(CBC TABLE 1017.2):
ALLOWED 200' PROVIDED : MAX 85'
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
-E S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
G
E
G R
E S
S
F
L O
O
T
D
A T
E
E
R
M
A H
S A
J A
V A
H E
R I A
N
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
EGRESS FLOOR PLAN
C O
A
L Y
S I S
G-008
N
OCCUPANCY LEGEND
(TABLE1004.5 CBC)
OFFICE (BUSINESS) 3,152 SF/150 = 22 OCC.
READING 4,589 SF/50 = 92 OCC.
ASSEMBLY-UNCONC. CHAIRS & TABLES 1,731 SF/15 = 116 OCC.
STORAGE 157 SF/300 = 1 OCC.
STACKS 3,396 SF/100 = 34 OCC.
TOTAL 265 OCC.
ASSEMBLY GROUP A-3 (LIBRARY)
PLUMBING FIXTURES CALCULATIONS
PLUMBING FIXTURE REQUIRED
WATER CLOSET URINALS LAVATORIES
MALE FEMALE MALE FEMALEMALE
2 4 2 1 2
PROVIDED 2 4 2 2 2
DRINKING FOUNTAINS
ALLOWABLE AREA DETERMINATION: (TABLE 506.2)
TYPE OF CONSTRUCTION: III-B
TYPE OF OCCUPANCY: A-3
EXISTING BUILDING AREA: 13,994 SQ.FT.
BASIC ALLOWABLE FLOOR AREA: 9,500 SQ.FT.
= 9,500 + (9500 X 0.50) =
= 14,250 SQ.FT. (ALLOWABLE AREA) > 13,994 SQ.FT.
375' / 655' = 0.57 X 100 = 57 %
TABLE 506.3.3, OPEN SPACE 30' OR GREATER = 0.50
-0
1-
S T
L
A
H
A B
B
U
L E
V A
R D
NORTH ORANGE STREET
ZUTANO LN
NO PARKING
EXISTING PARKING
E X
I S
T I N
G
P
A R
K I N
G
INFORMATION
CORRIDOR
FRIENDS
OF
LIBRARY
FRIENDS
OF
LIBRARY
MEN
CONMUNITY ROOM
COURTYARD
STAFF
BATHROOM
IT
ROOM
MECH
WOMEN
LOBBY
STORAGE
JANITOR
STUDY
ROOM
LIBRARIAN
STAFF
LOUNGE
STUDY
ROOM
STUDY
ROOM
WORK
ROOM
D
F
CHILDREN READING AREA
PRINTER
SELF CHECK-OUT
COMMON AREA
ADULT READING AREA
TEEN READING AREA
LAPTOPS
TEEN READING AREA
PC RES OPAC
B O
O K
D R
O P
T V
L O
W
S
H E
L V
I N
G
CHILDREN SEATING AREA &
MOBILE SHELVING
STORAGE
M W
RAISED GARDEN
DN.
A/C
TRASH
ENCLOSURE
BLR
H
R
R
E F
U G
E
A
R E
A
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
S
I T
E
P
L
O
T
D
A T
E
E
R
S
H E
L L E
Y S
I V
A K
A E
D L
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/16" = 1'-0"
SITE PLAN
S I T
E
P
L A
N
A-011
N
PROVIDE CODE COMPLIANT PATH OF TRAVEL FROM PUBLIC SIDEWALK TO BUILDING ENTRANCE.
PLACE NECESSARY UNAUTHORIZED VEHICLES SIGN AT EACH ENTRANCE.
ACCESSIBLE PARKING SPACES ASPHALT SURFACE TO BE RECONSTRUCTED WITH GRADES NOT TO EXCEED 2% IN ANY DIRECTION PER ADA REQUIREMENTS.
THE ACCESS AISLE FOR VAN ACCESSIBLE PARKING TO BE REVISED TO 8'-0" WIDTH.
RESTRIPE ACCESS AISLE WITH WORDS “NO PARKING” WITH WHITE LETTERS MINIMUM 12” IN HEIGHT TO BE VISIBLE FROM ADJACENT VEHICULAR WAY.
DEMOLISH CONCRETE PATH, GRADE SURFACE TO LEVEL WITH ADJACENT GROUND USING CLEAN FILL SOIL AND REPLACE WITH NEW COMPLIANT PATH.
THE PRIMARY LIBRARY ENTRANCE PATH TO BE RECONSTRUCTED TO BE ADA COMPLIANT.
THE EXTERIOR BOOK DROP BOX SHALL COMPLY WITH 2022 CBC CODE FOR REACH RANGES.
COURTYARD CONTAINS ABRUPT EDGES AND/OR VARIATIONS OVER 1/4" THROUGHOUT, TO BE RECONSTRUCTED TO COMPLY WITH 2022 CBC.
EXTERIOR STAIRWAY & HANDRAIL SHALL COMPLY WITH 2022 CBC CODE.
RELOCATE AND REPLACE ROOF HATCH TO PROVIDE CODE COMPLIANT ACCESS.
ARBORIST TO EVALUATE TREE TO DETERMINE IF IT CAN BE SAVED WHEN CONCRETE SLAB IS REPLACED.
REMOVE EXISTING LANDSCAPE AND PREPARE THE AREA FOR INSTALLING THE BOILER AND DECORATIVE SCREEN ENCLOSURE ON A CONCRETE PAD.
NOT USED
(E) BUILDING
MAIN ENTRANCE
(E) PUBLIC SIDEWALK
PATH OF TRAVEL
FROM PUBLIC WAY
-0
1-
CORRIDOR
STORAGE
AV
ROOMKITCHEN
FRIENDS
OF
LIBRARY
FRIENDS
OF
LIBRARY
MEN
CONMUNITY ROOM
COURTYARD
STAFF
BATHROOM
IT
ROOM
MECH
WOMEN
STORAGE
JANITOR
STAFF
LOUNGE
D
F
INFORMATION
DESK AREA
RAISED GARDEN
DN.
A/C
TRASH
ENCLOSURE
BLR
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
D
E M
O L I T
I O
N
F
L O
O
T
D
A T
E
E
R
S
H E
L L
E Y
S
I V
A K
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
DEMOLITION FLOOR PLAN
D E
M O
L I T
I O
N
F
L O
A
N
A-111
N
LEGEND
EXISTING CONSTRUCTION TO BE DEMOLISHED
EXISTING CONSTRUCTION TO REMAIN
EXISTING INTERIOR NON-STRUCTURAL PARTITION WALL TO BE REMOVED.
EXISTING INTERIOR DOOR AND FRAME TO BE REMOVED.
REMOVE EXISTING FLOOR FINISH AND BASE.REMOVE ALL ADHESIVES, PREPARE SURFACE TO
RECEIVE NEW FINISH.
EXISTING MILLWORK TO BE DEMOLISHED. CAP EXISTING WIRE AND PATCH & REPAIR THE SLAB AS
NECESSARY.
EXISTING FURNITURE TO BE REMOVED AND RETURNED TO OWNER.
EXISTING BOOK SHELVES TO BE REMOVED AND RETURNED TO OWNER.
EXISTING NON-COMPLIANT ROOF ACCESS CLOSET, LADDER AND HATCH TO BE REMOVED.
REMOVE EXISTING COUNTERTOP/MILLWORK AND BASE CABINET AND SINK.
FIRE ALARM PANEL TO REMAIN.
EXISTING STORAGE ROOM TO BE CONVERTED TO IT CLOSET.
EXISTING MECHANICAL ROOM TO REMAIN.
EXISTING PLUMBING FIXTURE TO BE REMOVED.
EXISTING HVAC CONTROL BOX TO BE RELOCATED.
EXISTING TOILET PARTITIONS TO BE REMOVED.
EXISTING COLUMN TO REMAIN. PROTECT IN PLACE.
EXISTING WALL MOUNT SHELVES TO BE REMOVED.
REPLACE THE ACCESS CONTROL WITH NEW SYSTEM PER CLIENT REQUIREMENTS.
EXISTING DISPLAY TO BE REMOVED.
EXISTING DRINKING FOUNTAIN TO BE REMOVED.
THE DOOR CLOSER NEED TO BE ADJUSTED TO COMPLY WITH MAXIMUM ALLOWABLE OPENING FORCE, TYP. WHERE (E) DOORS REMAIN.
ALL HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS & GATES SHALL COMPLY WITH 2022 CBC STANDARDS.
ALL RECEPTACLES AND SWITCHES SHALL POSITIONED CORRECTLY TO COMPLY WITH 2022 CBC STANDARDS.
THE GEOMETRIC SYMBOL FOR THE WOMEN'S ROOM SHOULD BE RELOCATED TO COMPLY WITHIN ALLOWABLE HEIGHT RANGE.
ALL THE ROOM DESIGNATION SIGNS TO BE REMOVED AND TO BE REPLACE WITH RAISED CHARACTERS.
EXISTING DOOR TO BE REMOVED, FRAME TO REMAIN.
EXISTING GLAZING (BOOK DROP ) TO BE REMOVED.
REMOVE ALL VINYL WALL COVERING, SKIM COAT AND PAINT WALLS.
EXISTING MASONRY WALL
EXISTING DATA CABINET TO BE RELOCATED TO IT ROOM (#10).
EXISTING GATE TO BE REMOVED AND THE EXISTING WALL PATCH & REPAIR.
EXISTING HANDRAILS TO BE REMOVED AND REPLACE WITH ADA COMPLIANT
HANDRAIL.
EXISTING ELECTRICAL PANEL TO REMAIN.
EXISTING ELECTRICAL SWITCHGEAR TO BE REPLACED.
EXISTING BOILER TO BE RELOCATED.
EXISTING STOREFRONT SYSTEM TO BE REMOVED.
REMOVE WOOD SIDING ON COLUMNS, TYPICAL.
-0
1-
DN.
BLR
BLR
S
S S S
S S
S
S S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
VARIES
9'-11"
VARIES
8'-0"
8'-0"
10'-0"
10'-0"
10'-0" 10'-0" 10'-0"
9'-11"
10'-0"
8'-0"
8'-0" 9'-11"
8'-0" 8'-0"
10'-0"
11'-0"
11'-0"
11'-0" 11'-0" 11'-0" 11'-0"
SD
SD
SD
SD
H
SD
SD
SD
SD
S
S
S
S
S
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
D
E M
O L I T
I O
N
R
E F
L E
C T
I L I N
G
P
L
O
T
D
A T
E
E
R
S
H E
L L E
Y S
I V
A K
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
DEMOLITION REFLECTED CEILING PLAN
D E
F
L E
C T
I L I N
G
P
L A
N
A-112
N
LEGENDGENERAL NOTES
ADD ½” DRYWALL OVER EXISTING GLUE ON ACOUSTICAL CEILING TILES. ADD ALTERNATE TO
REMOVE/ABATE TILES FIRST IF THEY CONTAIN ASBESTOS.
REMOVE ALL INTERIOR LIGHTING AND EXIT SIGNS.
REMOVE ALL WALL MOUNTED LIGHT FIXTURES.
REMOVE THE T-BAR GRID AND TILES AND FALLEN BATT INSULATION THAT IS NOT ABLE TO BE
REATTACHED THROUGHOUT THE LIBRARY, COMMUNITY ROOM AND FRIENDS OF LIBRARY AREA.
EXISTING GLU. LAM. BEAMS TO REMAIN.
PROTECT EXTERIOR SOFFIT IN PLACE AND PREPARE TO RECEIVE PAINT & EXTERIOR SURFACE
MOUNTED LIGHT FIXTURE TO BE REPLACED WITH LED LIGHT.
SUPPLY AND RETURN DIFFUSERS AND EXISTING DUCTWORK THROUGHOUT THE LIBRARY WILL
COORDINATE WITH MECHANICAL DESIGN. ALL DIFFUSERS WILL BE REPLACED WITH TITUS OMNI
STYLE U.N.O.
REMOVE T&G WOOD CEILING TREATMENT
TYP. CEILING GRID AND A.C.T. TO BE REMOVED
1. FIELD VERIFY ALL EXISTING CONDITIONS & IDENTIFY EXACT SCOPE OF WORK PRIOR
REMOVAL STARTS. CONTACT ARCHITECT & CLIENT IF THERE ARE ANY DISCREPANCIES.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ANY DEMOLITION OF HVAC/MECHANICAL,
AND ELECTRICAL SCOPE OF WORK WITH ENGINEERS DRAWINGS.
3. THE GENERAL CONTRACTOR MUST ALLOW FOR ADDITIONAL DEMOLITION THAT MAY NOT BE
SHOWN, BUT MAY BE REQUIRED TO ACHIEVE THE FINISHED RESULT, AS SHOWN ON THE
DRAWINGS.
4. PRIOR TO START OF DEMOLITION WORK, GENERAL CONTRACTOR SHALL PROVIDE A
PROTECTIVE BARRIER PER CLIENT AND LOCAL CITY REQUIREMENTS.
5. ALL EXISTING WORK TO REMAIN, UNLESS OTHERWISE NOTED.ALL DEMOLITION WORK SHALL
BE IN ACCORDANCE WITH THE CALIFORNIA FIRE CODE 2019 EDITION, SECTION 33.
6. ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE,
2019 EDITION, CHAPTER 33.
7. THE CONTRACTOR SHALL RESTORE TO ITS ORIGINAL CONDITION ANY EXISTING WORK
DAMAGED DURING DEMOLITION BUT INDICATED TO REMAIN.
8. ALL DIFFUSERS & RETURN GRILLES SHALL BE COVERED PRIOR TO ANY WORK. COORDINATE
WITH BUILDING ENGINEER & CLIENT.
9. REMOVE ALL DEBRIS. NO DEBRIS SHALL BE LEFT OR REMAIN DURING CONSTRUCTION.
TRASH REMOVAL IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
TYP.
TYP.
TYP.
TYP.
TYP.
3 3
2'X4' LED FIXTURE
EXISTING GYPSUM BOARD CEILING
EXISTING WOOD PANEL CEILING
1 1
-0
1-
INFORMATION
FRIENDS
OF
LIBRARY
FRIENDS
OF
LIBRARY
MEN
CONMUNITY ROOM
COURTYARD
STAFF
BATHROOM
IT
ROOM
MECH
WOMEN
LOBBY
STORAGE
JANITOR
STUDY
ROOM
LIBRARIAN
STAFF
LOUNGE
STUDY
ROOM
STUDY
ROOM
WORK
ROOM
D
F
CHILDREN READING AREA
PRINTER
SELF CHECK-OUT
COMMON AREA
ADULT READING AREA
TEEN READING AREA
LAPTOPS
TEEN READING AREA
PC RES OPAC
B O
O K
D R
O P
T V
L O
W
S
H E
L V
I N
G
CHILDREN SEATING AREA &
MOBILE SHELVING
STORAGE
M W
RAISED GARDEN
DN.
A/C
TRASH
ENCLOSURE
BLR
H
R
R
E F
U G
E
A
R E
A
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
F
L O
O
T
D
A T
E
E
R
S
H E
L L E
Y S
I V
A K
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
FLOOR PLAN
F L O
A
N
A-211
N
LEGENDGENERAL NOTES
NEW INTERIOR PARTITION.
NEW GLAZING.
NEW INTERIOR DOOR, SOLID WOOD, HM FRAME, PRIME/PAINT AND NEW HARDWARE.
EXISTING EXTERIOR GLAZING SYSTEM TO REMAIN.
PROVIDE BACKING FOR CONNECTION OF CASEWORK, FURNITURE, TV, WALL MOUNTED SHELVES.
NEW HI-LOW' DRINKING FOUNTAIN WITH BOTTLE FILLER.
NEW CARPET TILE THROUGHOUT, SEE FINISH PLAN.
CANTILEVERED SOLID SURFACE COUNTERS.
RELOCATE FLOOR OUTLETS WITH FLUSH TYPE DEEP BOXES AS REQUIRED.
ALL EXISTING COLUMNS AND INTERIOR WALLS TO RECEIVE NEW PAINT.
NEW TACTILE EXIT SIGNAGE PER CBC SECTION 1011.4.
NEW MAXIMUM OCCUPANCY SIGN.
NEW RECEPTION DESK. (USE EXISTING ELECTRICAL CONNECTIONS IF POSSIBLE)
NEW BOOK SHELVES.
1. SEE ACCESSIBILITY SHEETS FOR ADDITIONAL NOTES AND DIMENSIONS, TYP.
2. ALL DIMENSIONS ARE FROM FACE OF FINISH U.N.O
3. ALL EXISTING CONDITIONS SHALL BE VERIFIED IN FIELD PRIOR TO STARTING THE PROJECT.
4. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, ELECTRICAL OR
5. MECHANICAL DRAWINGS AND OBTAIN CLARIFICATION BEFORE COMMENCING WITH WORK.
6. WHERE ELECTRICAL WORK IS SPECIFIED IN CONJUNCTION WITH CABINET WORK, LAMPS AND
FIXTURES SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. CUT-OUTS FOR SWITCHES,
OUTLETS AS REQUIRED BY THE CABINET CONTRACTOR, SHALL BE COORDINATED WITH THE
ELECTRICAL CONTRACTOR, U.N.O.
7. GANG SWITCHES UNDER ONE COVER PLATE WHENEVER POSSIBLE.
8. LOCATION AND CLASSIFICATION OF FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE W/ CCR TITLE
19. A MINIMUM OF ONE 2A-10BC SHALL BE PROVIDED, APPROVED BY THE FIRE INSPECTOR.
31 31 31
NEW PLUMBING FIXTURES AND ACCESSORIES.
NEW RESTROOM PARTITIONS.
NEW RESTROOM DOOR SIGN.
NEW CABINETS, COUNTERTOP, SINK.
NEW FULL SIZE REFRIGERATOR.
NEW BUILT-IN MICROWAVE.
NEW CUSTOM MILLWORK LOCKERS 2 ROWS HIGH @42" A.F.F.
NEW BOILER LOCATION, WITH NEW SCREEN FENCE.
NEW PORCELAIN WALL AND FLOOR TILE IN RESTROOMS.
NEW ADA COMPLIANT HANDRAIL.
NEW DOOR WITH ADA COMPLIANT VISION LITE IN EXISTING FRAME .
EXISTING DOOR & FRAME TO RECEIVE PAINT AND HARDWARE.
UPGRADE EXISTING ADJACENT WALLS TO COMPLY WITH REQUIRED
FIRE RATING CODE FOR SEPARATION OF ELECTRICAL SWITCHGEAR.
NEW 2 HR FIRE RATED STOREFRONT/ WALL UP TO STRUCTURE.
DENOTES DOOR NUMBER. REFER TO DOOR SCHEDULE/
DOOR TYPES, SHEET A-602.
A
WALL TYPE, REFER
TO WALL LEGEND
DENOTES WINDOW NUMBER. REFER TO WINDOW
SCHEDULE, SHEET A-603.
FIRE EXTINGUISHER BY OVAL OR EQUAL LOW PROFILE
ALIGN FINISHES.
FE
EXISTING INTERIOR WALL
NEW WALL
NEW LOW SLUMP STONE WALL
FLOOR OUTLET, REFER TO ELECTRICAL DRAWINGS
EXISTING DOOR
NEW DOOR
EXISTING MASONRY WALL
EXISTING GLAZED AUTOMATIC DOORS TO REMAIN.
WRAP COLUMNS IN GYP. BOARD REPLACE FURRING AS NECESSARY.TYP.
NEW INTERIOR STOREFRONT WALL AND DOOR
NEW CLOSET WITH CODE COMPLIANT ROOF ACCESS LADDER AND HATCH.
-0
1-
DN.
BLR
BLR
S
VARIES
9'-11"
VARIES
8'-0"
8'-0"
10'-0"
10'-0"
10'-0" 10'-0" 10'-0"
9'-11"
10'-0"
8'-0"
8'-0" 9'-11"
8'-0" 8'-0"
10'-0"
11'-0"
11'-0"
11'-0" 11'-0" 11'-0" 11'-0"
S
S
S
S
S
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
P
R O
P O
S E
D
R
E F
L E
C T
I L I N
G
P
L
O
T
D
A T
E
E
R
S
H E
L L E
Y S
I V
A K
A E
D L
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
REFLECTED CEILING PLAN
R E
F L E
C T
I L I N
G
P
L A
N
A-212
N
LEGENDGENERAL NOTES
1. FIELD VERIFY ALL EXISTING CONDITIONS & IDENTIFY EXACT SCOPE OF WORK PRIOR
REMOVAL STARTS. CONTACT ARCHITECT & CLIENT IF THERE ARE ANY DISCREPANCIES.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ANY DEMOLITION OF HVAC/MECHANICAL,
AND ELECTRICAL SCOPE OF WORK WITH ENGINEERS DRAWINGS.
3. THE GENERAL CONTRACTOR MUST ALLOW FOR ADDITIONAL DEMOLITION THAT MAY NOT BE
SHOWN, BUT MAY BE REQUIRED TO ACHIEVE THE FINISHED RESULT, AS SHOWN ON THE
DRAWINGS.
4. PRIOR TO START OF DEMOLITION WORK, GENERAL CONTRACTOR SHALL PROVIDE A
PROTECTIVE BARRIER PER CLIENT AND LOCAL CITY REQUIREMENTS.
5. ALL EXISTING WORK TO REMAIN, UNLESS OTHERWISE NOTED.ALL DEMOLITION WORK SHALL
BE IN ACCORDANCE WITH THE CALIFORNIA FIRE CODE 2019 EDITION, SECTION 33.
6. ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE,
2019 EDITION, CHAPTER 33.
7. THE CONTRACTOR SHALL RESTORE TO ITS ORIGINAL CONDITION ANY EXISTING WORK
DAMAGED DURING DEMOLITION BUT INDICATED TO REMAIN.
8. ALL DIFFUSERS & RETURN GRILLES SHALL BE COVERED PRIOR TO ANY WORK. COORDINATE
WITH BUILDING ENGINEER & CLIENT.
9. REMOVE ALL DEBRIS. NO DEBRIS SHALL BE LEFT OR REMAIN DURING CONSTRUCTION.
TRASH REMOVAL IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
2'X4' ACOUSTICAL T-BAR
REPLACE THE T-BAR GRID AND TILES THROUGHOUT THE LIBRARY, COMMUNITY ROOM AND FRIENDS
OF LIBRARY AREA.INSTALL NEW R-30 BATT INSULATION BETWEEN RAFTERS THROUGHOUT.
FURR OUT FOR NEW DRYWALL AT THE UNDERSIDE OF THE MECHANICAL MEZZANINE AND
INCORPORATE DECORATIVE LIGHTING.
ADD ½” DRYWALL OVER EXISTING GLUE ON ACOUSTICAL CEILING TILES. ADD ALTERNATE TO
REMOVE/ABATE TILES FIRST IF THEY CONTAIN ASBESTOS.
NEW GYPSUM BOARD CEILING, PAINT.
ADD NEW LED LINEAR PENDANT FIXTURES ABOVE STACKS AND OTHER SELECTED AREAS.
NEW TITUS OMNI HVAC DIFFUSERS THROUGHOUT.
NEW 2X4 LED LIGHT FIXTURE.
EXISTING ACCESS PANEL TO REMAIN.
NEW EXTERIOR SURFACE MOUNTED LED LIGHT FIXTURE.
NEW DECORATIVE SURFACE MOUNTED LIGHT FIXTURE
N
2'X4' LED FIXTURE
EXISTING GYP. CEILING
NEW GYP. CEILING
2 2
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
6" LED CAN LIGHT
24" CAMMAN LED LIGHTING
18" CAMMAN LED LIGHTING
LINEAR LED LIGHTING
SPI LIGHTING ZYNN 2" LINES
SURFACE MOUNTED LIGHT FIXTURE
LIGHT FIXTURE SCHEDULE
-0
1-
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
R
O O
F
P
L
O
T
D
A T
E
E
R
M
A H
S A
J A
V A
H E
R I A
N
A E
D L
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
ROOF PLAN
R O
A
N
A-213
N
REMOVE CLAY ROOF TILES AND REPLACE WITH CRRC CODE APPROVED ASPHALT SHINGLES AND WEATHER
BARRIER. INCLUDE CONTINUOUS INSULATION ABOVE THE ROOF AND NEW BATT INSULATION BELOW. ALLOW FOR
REPLACEMENT OF 20% OF THE ROOF SHEATHING AND BATT INSULATION.
REPLACE ROOF SEALANT THROUGHOUT.
REPAIR MECHANICAL WELL ROOFING AS REQUIRED.
REPLACE GUTTER, FLASHING AND DOWNSPOUTS AT ROOF PERIMETER, FACTORY FINISH, COLOR PER OWNER.
ANCHOR ROOF TOP MECHANICAL UNITS AS REQUIRED, TYPICAL.
CODE COMPLIANT ROOF ACCESS HATCH AND LADDER
PATCH AND REPAIR AREA OF OLD ACCESS HATCH.
-0
1-
KEY NOTES
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
E
X T
E R
I O
R
E
L E
V A
T I O
O
T
D
A T
E
E
R
S
H E
L L E
Y S
I V
A K
A E
D L
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
EAST ELEVATION
E X
T E
R I O
R
E
L E
V A
T I O
N S
A-114
REPAIR ALL EXTERIOR WALL STUCCO CRACKS & FINISH TO MATCH EXISTING.
NEW GLAZING.
REMOVE CLAY ROOF TILES AND REPLACE WITH CRRC CODE APPROVED ASPHALT
SHINGLES AND WEATHER BARRIER. INCLUDE CONTINUOUS INSULATION ABOVE THE
ROOF AND NEW BATT INSULATION BELOW. ALLOW FOR REPLACEMENT OF 20% OF
THE ROOF SHEATHING AND BATT INSULATION.
REPLACE SHEET METAL GUTTERS AND DOWNSPOUTS, FACTORY FINISH COLOR TBD.
NEW 2-HOUR FIRE RATED DOORS, STOREFRONT AND GLAZING
1/8" = 1'-0"
WEST ELEVATION
1/8" = 1'-0"
NORTH ELEVATION
1/8" = 1'-0"
SOUTH ELEVATION
-0
1-
INFORMATION
FRIENDS
OF
LIBRARY
FRIENDS
OF
LIBRARY
MEN
CONMUNITY ROOM
COURTYARD
STAFF
BATHROOM
IT
ROOM
MECH
WOMEN
LOBBY
STORAGE
JANITOR
STUDY
ROOM
LIBRARIAN
STAFF
LOUNGE
STUDY
ROOM
STUDY
ROOM
WORK
ROOM
D
F
CHILDREN READING AREA
PRINTER
SELF CHECK-OUT
COMMON AREA
ADULT READING AREA
TEEN READING AREA
LAPTOPS
TEEN READING AREA
PC RES OPAC
B O
O K
D R
O P
T V
L O
W
S
H E
L V
I N
G
CHILDREN SEATING AREA &
MOBILE SHELVING
STORAGE
M W
RAISED GARDEN
DN.
A/C
TRASH
ENCLOSURE
BLR
BLR
H
R
R
E F
U G
E
A
R E
A
COUNTY APPROVAL STAMP
Sheet
C o un ty o f
O ra ng e
O C
F ac ili tie s D es ig n
C o ns tr uc tio n
PU
B
LI
C
W O R K S
S h t Ti tle
P ro je ct
A
-E
D es ig n
C h kd
D at e P
R O
J.
N
S ea l
C o ns ul ta nt s
D ra w n
C h kd
D at e
R ev is io ns
D es cr ip
B y D at e
S ym
Plan No.
P
E T
E R
S
C
A N
Y O
N
R
O A
D
S
U I T
E
I R
V I N
E
C
A
T E
L
X
I D
S
P r o j e c t
X
I D
S
I D
S
G
R O
U P
LA
H
AB
RA
LI
BR
AR
Y
RE
FR
ES
H
OC
PW
9-
2-
9-
PL
-1
I D
S
G
R O
I
C A
T I O
N
S
P
R O
J E
C T
S S
H A
R E
D X
O
C P
W
B
B
R A
F
R E
S H
C
A D
A
R C
H X
A
F
I N
I S
H
F
L O
O
T
D
A T
E
E
R
S
H E
L L
E Y
S
I V
A K
M
J S
S
S
D
S
B
M I T
T A
L
1 E
LA
H
AB
RA
B
LV
D, LA
H
AB
RA
, C
A
1/8" = 1'-0"
FINISH FLOOR PLAN
F I N
I S
H
F
L O
A
N
A-221
N
LEGEND
C4
VENDOR: KINETEX
ITEM: MAJOR METRO
COLOR: 3405 URBANE
C5
VENDOR: KINETEX
ITEM: MAJOR METRO
COLOR: T.B.D.
PT1 FLOOR TILE
VENDOR: DALTILE
ITEM: VOLUME 1.0
COLOR: VL71 DEGREES SILVER
SIZE: 12"X24"
GROUT: T.B.D.
C1 GRAY COMBO
SHAW CONTRACT
LIVING SYSTEMS
TRANSFORM TILE
5T308-56760
CALL FOR AVAILABILITY!
C2 MULTI-COLOR CARPET
SHAW CONTRACT
LIVING SYSTEMS
TRANSFORM COLOR TILE
5T311-05865
C3 SOLID
SHAW CONTRACT
LIVING SYSTEMS
ENDLESS TILE
5T305-05868
PT2 RESTROOM WALL TILE AND COVED BASE
VENDOR: DALTILE
ITEM: HARMONIST
COLOR: AMITY HM32
SIZE: 12"X24" BULLNOSE TOP & CORNERS
FINISH: MATTE
GROUT: T.B.D.
CT1 BREAK ROOM WALL TILE
VENDOR: DALTILE
ITEM: COLOR WHEEL CLASSIC
COLOR: 0190 ARCTIC WHITE
SIZE: 3"X6"
FINISH: MATTE
GROUT; CUSTOM 381 BRIGHT WHITE,
B1 TOELESS WALL BASE
VENDOR: TARKETT/JOHNSONITE
ITEM: VINYL 080"
COLOR: 63 BURNED UMBER
SIZE: 4" TOELESS AT CARPET TILE
LENGTH: COIL/CONTINUOUS ROLL
B2 TOE WALL BASE
VENDOR: TARKETT/JOHNSONITE
ITEM: VINYL 080"
COLOR: 63 BURNED UMBER
SIZE: 4" TOE AT KINETEX
LENGTH: COIL/CONTINUOUS ROLL
-0
1-
| Sheets and Views |
| 22X085-06_G-001 PROJECT INFORMATION & DRAWING INDEX-G-001 |
| 22X085-06_G-008- EGRESS FLOOR PLAN-G-008 |
| 22X085-06_A-011- SITE PLAN-A-011 |
| 22X085-06_A-111-DEMOLITION FLOOR PLAN-A-211 |
| 22X085-06_A-112- DEMOLITION REFLECTED CEILING PLAN-A-112 |
| 22X085-06_A-211- FLOOR PLAN-A-211 |
| 22X085-06_A-212- PROPOSED REFLECTED CEILING PLAN-A-212 |
| 22X085-06_A-213- ROOF PLAN-A-213 |
| 22X085-06_A-114- EXTERIOR ELEVATIONS-A-114 |
| 22X085-06_A-221- FINISH FLOOR PLAN-A-221 |
File details come from the government source that posted it. Updated .