Kongsberg124786 Rev -_Gondola Installation Drawing Outline.pdf
PDF 94 KB Posted
- Solicitation number
- 1305M223QNMAN0122
About this file
This drawing package is for a gondola installation on NOAA's Ship Thomas Jefferson. The solicitation requests pricing and past performance information for the ship's drydocking in fiscal year 2024. Offerors must submit pricing on the provided schedule by the solicitation closing date. The work includes installation of equipment such as navigation transducers, hatches, sensors, and piping. The Department of Commerce National Oceanic and Atmospheric Administration will evaluate proposals and past performance questionnaires from potential contractors. The solicitation references include drawings, manuals, and specifications to detail the technical requirements for the drydocking and modernization of systems on the research vessel.
View the file
Other files
Show 40 more
Latest 50 of 226 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
~ 5.375
2.0 MIN TYP
255.1
195.4
~ 10.625
~ 235.1
10.75
CL
3D VIEW
A-ASECTION
CL
(TRIM LINE)
EXCESS MATERIAL
(CASING)
NOTES: UNLESS OTHERWISE SPECIFIED.
FORWARD
BOTTOM SURFACE
VIEW SHOWN LOOKING "UP" IN VESSEL COORDINATES
DIMENSIONS ARE SHOWN AS DESIGNED AND SHALL BE DETERMINED
BY SHIPYARD/WORKSHOP PRIOR TO FABRICATION OF THE
FAIRING PANELS, PIPES AND THE HATCH PLATE.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONTROLLED
P. PHUNG 18APR2016
P. PHUNG 4/18/2016
KONGSBERG Underwater Technology, Inc
GODOLA
124786
124786
124786
0.5 X1 EM 710/0.7X0.7 EM 2040
FILE NAME: 2
1 OFUNIT WT
D
PROJECT NAME
CONTRACT NO.
.XXX ±.010
.XX ±.03
±2°
SURFACE ROUGHNESS
FILLETS
BROKEN EDGES
DO NOT SCALE DRAWING
PART SHALL BE FREE OF BURRS
3 PLACE DECIMAL
2 PLACE DECIMAL
ANGLES
TOLERANCES
8 3
D
C
B
A
DWG NO.
ZONE REV DESCRIPTION
REVISION HISTORY
DWG NO. SHT
SHEET
CAGE CODESIZE
SCALE
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
7 6 5 4 3
7 6 5 4
A
B
C
D
.020 MAX
MAX
P. PHUNG
APPROVED
DRAWN
DES ENGR
7APR2016
327E2 -
THIRD ANGLE PROJECTION
1:16
INSTALLATION DRAWING OUTLINE,
19210 33rd Avenue West, Suite A, Lynnwood, WA 98036
1 PLACE DECIMAL .X ±.1
SolidWorks GENERATED DRAWING
REV.
TJ GONDOLA
KONGSBERG CORPORATION.
INITIAL RELEASE
PROPRIETARY INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
KONGSBERG CORPORATION. COPYRIGHT
© KONGSBERG CORPORATION 2000-2014
(OR YEAR OF DOCUMENT REVISION
RECORDED HEREIN), UNPUBLISHED
RIGHTS RESERVED UNDER THE
COPYRIGHT LAWS OF THE UNITED
STATES. ALL INFORMATION, DATA,
DESIGNS, AND DRAWINGS CONTAINED
HEREIN ARE THE PROPERTY OF
KONGSBERG CORPORATION AND MAY
NOT BE REPRODUCED, COPIED,
APPROPRIATED OR DISCLOSED TO THIRD
PARTIES DIRECTLY OR INDIRECTLY, IN
WHOLE OR IN PART, WITHOUT THE
EXPRESS WRITTEN CONSENT OF
X
(124789)
(FURUNO 50kHz NAV XDCR)
TX EM 2040
R X
E M
TX EM 710 TX EM 710
(124788)
(HATCH)
R X
E M
(HATCH)
(FURUNO 200kHz NAV XDCR)
(SSSVS INLET)
(BUBBLE DRAFT SENSOR)
(CABLE PIPE)
CL
(FRAME 36)
(FRAME 35)
(124787)
(124589)
(HATCH PLATE)
64.9
R11.44
A
A
(AFTER TRIMMED)
(TRIM TO FIT THE HULL)
(FAIRING PANEL)
(PIPE)
15°
65°
.59
CL
(10" NPS CABLE PIPE)
3035 26272829
(BUBBLE DRAFT SENSOR)
3137 34 33 32
(SSSVS INLET)