Kennel Specification.pdf

PDF 2 MB Posted

Attached to
Adoption Room Renovation
Solicitation number
82071
Issued by
Hanover County, Arlington CDP, Virginia

About this file

This file contains detailed kennel specifications and drawings from Midmark for the Hanover County Animal Control facility in Virginia. The documents show architectural plans and specifications for kennel installations including floor plans, room layouts, and 3D views of a kennel room renovation project. The specifications detail multiple kennel configurations with dimensions of 350" x 73" x 75", 290.5" x 73" x 75", and 245.75" x 61" x 75", featuring stainless steel construction with Sky-245 finish panels and multiple accessories including rest benches, top covers, and support posts.

The technical specifications include details for Sani-Kennel systems with specific requirements for floor slopes not exceeding 2" maximum panel allowance, wall/floor coving options (cant, radial, and vinyl easycove), and FRP panel installations. The kennels include gates measuring 30.25" and utilize Midmark's Sani-T or Sani-L systems. Major components specified include 8 rest benches (RBXX00000-XXX), 8 top covers (TCXX-XX00000-XXX), and multiple support posts (GPSK-8164000-XXX), all finished in 245-Sky and 929-Stainless Steel materials.

View the file

Other files

File Type Posted
Adoption Room Renovation.pdf PDF
Kennel Specification.pdf PDF
Adoption Room Renovation.pdf PDF
Kennel Specification.pdf PDF
Adoption Room Renovation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

4/16Drawing Template: - Revision: - Change Order: -

Signed Drawings Required To Process Order

(Signature) (Date)

WALL TO WALL 378" [31'-6"]

W

AL

L

TO

W

AL

L

[2 9'

-2

40"

38"

150"

PLAN

DIRECTIONS

W E N

S

WALL TO GUTTER 15'-6" WALL TO GUTTER 15'-6"

GUTTER 6"

VERIFY SLOPEVERIFY SLOPE

Version: 1

Field Measurements Approved

Floor Plan View

Kennel Room

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

5/16Drawing Template: - Revision: - Change Order: -www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Signed Drawings Required To Process Order

(Signature) (Date)

72.25"

60.25"73.00" 72.25"

Version: 1

Room Plan View

RBXX00000-XXX | Rest Bench QTY: 8

TCXX-XX00000-XXX | Top Cover QTY: 8

6/16Drawing Template: - Revision: - Change Order: -www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Kennel Room

Signed Drawings Required To Process Order

(Signature) (Date)

FRP

SG37-RNNDNYW-245

FRP

SG37-RNNDNYP-245

FRP

SG37-RNNDNYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYW-245

34.75"

36.50"

34.75"

37.00"

34.75"

37.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

47.50"

76.38"

350.00"

Version: 1

Accessories:

245-Sky, 929-Stainless Steel

350" x 73" x 75"

Finish:

Dimensions:

Threshold:

Note: Field Measurement Approved

Not Included www.midmark.com

Phone: 1-800-MIDMARK

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

Kennel Room 7/16Drawing Template: - Revision: - Change Order: -

Signed Drawings Required To Process Order

(Signature) (Date)

Kennel 3D View

Signed Drawings Required To Process Order

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Kennel Room

GPSK-8164000-XXX | Support Post QTY: 1

RBXX00000-XXX | Rest Bench QTY: 6

TCXX-XX00000-XXX | Top Cover QTY: 6

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

8/16Drawing Template: - Revision: - Change Order: -

FRP FRP

SF48-LRNDSYW-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

45.75" [30.25" Gate]

47.63"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

50.88"

76.38"

290.50"

Threshold: Not Included

290.5" x 73" x 75"

Version: 1

Dimensions:

Finish:

Field Measurement ApprovedNote:

245-Sky, 929-Stainless Steel

Accessories:

GPSK-8164000-XXX | Support Post QTY: 1

RBXX00000-XXX | Rest Bench QTY: 6

TCXX-XX00000-XXX | Top Cover QTY: 6

Kennel Room

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

9/16Drawing Template: - Revision: - Change Order: -

Signed Drawings Required To Process Order

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

FRPFRP

SF48-RLNDSYW-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

45.75" [30.25" Gate]

47.63"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

50.88"

76.38"

290.50"

Finish:

Not Included

Field Measurement Approved

Dimensions:

245-Sky, 929-Stainless Steel

Threshold:

Version: 1

Note:

Accessories:290.5" x 72.25" x 75"

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

10/16Drawing Template: - Revision: - Change Order: -

Kennel Room

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

11/16Drawing Template: - Revision: - Change Order: -

GPSK-8164000-XXX | Support Post QTY: 2

RBXX00000-XXX | Rest Bench QTY: 5

TCXX-XX00000-XXX | Top Cover QTY: 5

Kennel Room

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

45.75" [30.25" Gate]

50.88"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

50.88"

76.38"

245.75"

Dimensions:

Not Included

Version: 1

Finish:

Field Measurement Approved

245.75" x 61" x 75"

Note:

Accessories:

Threshold:

245-Sky, 929-Stainless Steel

Kennel Room www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Signed Drawings Required To Process Order

(Signature) (Date)

12/16Drawing Template: - Revision: - Change Order: -

14/16Drawing Template: - Revision: - Change Order: -

Sani-Kennel Details

* The slope information is for kennel systems using Midmark Sani-T or Sani-L systems only.

* Customization will be required if the flooring exceeds the 2” slope maximum panel allowance.

* Midmark is not responsbile for replacing products modified in the field.

Disclaimers www.midmark.com design@midmark.com

Phone: 1-800-MIDMARK

Floor Slope Wall/Floor Coving

15/16Drawing Template: - Revision: - Change Order: -

Stainless Steel

Stainless Steel

Back Panel

Stainless Steel

Side Panel

75.00"

47.25"

75.00"

60.00"

Version: 1

CAUTION! THIS PAPER REGENERATES ON EACH UPDATE. ANY MARKUPS WILL BE LOST.

Sani-Kennel Panel Views www.midmark.com

16/16Drawing Template: - Revision: - Change Order: -

Stainless Steel

Side Panel

75.00"

72.00"

Version: 1

CAUTION! THIS PAPER REGENERATES ON EACH UPDATE. ANY MARKUPS WILL BE LOST.

www.midmark.com design@midmark.com

Sani-Kennel Panel Views

File details come from the government source that posted it. Updated .